MAURY USCG vessel records
← All vessels

LIBERTY

LIBERTY is a passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in April 2025, along with 10 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 14 April 2025.

Built
Not recorded
Last inspected
14 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 April 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-53933

Documentation record

Tonnage as PSIX records it1 - Simplified, Gross Ton
1 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

14 April 2025 In-Service Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8095074
15 November 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8037613
29 March 2024 COI Inspection · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7902182
6 January 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7617454
8 February 2022 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7387457
25 October 2021 Drydock Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7329160
22 September 2020 Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7071747
16 November 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6850203
10 September 2019 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6814114
26 December 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6602811
8 January 2018 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6323215
16 December 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6045512
6 September 2016 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5989871

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 April 2025 Resolved
- A flammable vapor detection system must be operational for 30 seconds prior to engine startup and continue sensing the entire time the engine is running. - must meet UL 1110 - A flammable vapor detection system must provide a visual and audible alarm at the operating station. - An operation and maintenance manual for the flammable vapor detection system must be kept onboard.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2025
Resolution: Vapor detection test witnessed, system is fully functional and manual is on board.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 April 2025 Resolved
A fixed gas fire extinguishing system must automatically shut down all powered exhaust blowers for the space. Test in presence of marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2025
Resolution: Vapor detetion system witnessed full operational.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 April 2025 Resolved
A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2025
Resolution: placard in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2025 Resolved
a visual and audible alarm must be provided at the operating station to indicate a high water level.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2025
Resolution: system witnessed to be fully functional.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2025 Resolved
Three 9.5 liter (2.5 gallon) Fire buckets, lanyard, "FIRE BUCKET", NOT Colorado kings fire buckets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2025
Resolution: Buckets purchased and on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 December 2018 Resolved
Annaul inspection lapsed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2024
Navigation › Piloting/Steering › Marine Charts
Issued 8 January 2018 Resolved
Provide charts for area of operation
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 January 2018 Resolved
Provide serviceable first aid kits
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 December 2016 Resolved
Renew water light battery. Restricted to daylight operation.
Due 15 January 2017
Resolved 7 February 2017
Lifesaving › Visual Distress Signals (General) › Expired
Issued 16 December 2016 Resolved
Provide required 01 hand flare; Orange smoke or red hand flare.
Due 15 June 2017
Resolved 7 February 2017

Ownership record