01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 April 2026
Resolved
Except as provided by § 15.725, no vessel may be navigated unless it has in its service and onboard the crew complement required by the COI. Vessel has insufficient manning in accordance with COI. Prior to operating, vessel must prove adequate manning and conduct satisfactory drills in the presence of a Marine Inspector.
46 CFR 15.515(a)
Action required: 705 - Other - as specified
Resolved 3 April 2026
Resolution: Mate was medically cleared and returned on board vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 December 2025
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Hydrostatic release for EPIRB was expired.
46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2026
Resolution: New hydrostatic release installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 December 2025
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. 02 smoke detectors in the overnight accommodation space were giving error codes and were being replaced.
46 CFR 181.405
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2026
Resolution: New smoke detctors installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 December 2025
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. 02 water light batteries were expired.
46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2025
Resolution: Received satisfactory evidence of new life float light batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2025
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter. 02 life jacket lights inop
46 CFR 185.75
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2025
Resolution: Received satisfactory evidence of new life jacket lights
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 December 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List; Tide tables. Vessel publications were not up to date.
46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 6 January 2026
Resolution: Owner obtained new publications.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 December 2025
Resolved
Fire fighting and abandon ship drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel had not logged any drills in over a year. Provided vessel with log booklet.
46 CFR 185.524(d)(1)(2)
46 CFR 185.520(f)(1)(2)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2025
Resolution: Provided vessel with booklet to log drills
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 December 2025
Resolved
The master of the vessel shall ensure that the EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel did not have a log of monthly EPIRB tests. Conducted satisfactory test of EPIRB and provided vessel with log booklet.
46 CFR 185.728(c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2025
Resolution: Conducted satisfactory test of EPIRB and provided vessel with booklet to log maintenance
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 August 2024
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Upon inspection, MI determined vessel was not ready for inspection. Ensure vessel is in compliance and reschedule inspection at a later date.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2024
Resolution: Vessel had succesful COI inspection conducted by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Inspection found blank spot where breaker was removed from electrical panel in the engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 23 September 2024
Resolution: Replacedf blank in breaker panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Inspection found degraded reflective tape on life rings and life floats.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 25 September 2024
Resolution: O/O Submitted photographic evidenc of SOLAS tape replacement, ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply line and... shall be operable from outside the tank compartment. Fuel valve servicing the port fuel tank has wire buckle that is catching on the deck plate not allowing the valve to actuate closed. Make repairs to enable the valve to be fully operable.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 7 November 2023
Resolution: Received documentary evidence of proper operation of fuel shut off valves.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 November 2023
Resolved
Each vessel on an Oceans service must have an approved EPIRB, that is stowed in a manner that makes it capable of being float free if the vessel sinks. The hydrostatic release for the EPIRB is expired. Install a unexpired hydrostatic release and mark expiration date upon installation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 7 November 2023
Resolution: Received documentary evidence of properly marked and installed hydrostatic release.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 November 2023
Resolved
Vessel does not have an interconnected smoke detection and alarm system. Vessels on a Coast wise or Oceans route must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces.
§ 181.450: An interconnected detection and alarm system must:
(1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217.
(2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) to be protected by the interconnected detection and alarm system;
(3) Contain an independent power source; and
(4) Alarm on low power.
Provide evidence to the local OCMI that an interconnected detection system meeting the above requirements has been installed and is functional.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 11 January 2024
Resolution: Vessel installed interconnected fire detecition system. Inspected and tested intercnooected fire detection system, all SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 1 November 2023
Resolved
Except as otherwise provided, each space accessible to passengers or used by the crew on a regular basis, must have two means of escape... and must be capable of being opened by one person from either side. Vessel's forward escape hatch is only capable of being opened from inside the cabin. Make hatch capable of opening from both sides prior to 27DEC23.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 November 2023
Resolved 11 January 2024
Resolution: Vessel installed nre escape hatch, the hatch was opened from both the inside and outside, SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 November 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. 01 smoke detectors were expired. No overnight passengers until detector is replaced.
46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 December 2022
Resolution: New smoke detector was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 November 2022
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. 02 batteries from each life float were expired.
46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2023
Resolution: Received photographic evidence of replaced batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 November 2022
Resolved
Each floating water light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant. 02 batteries from ring life buoy water lights were expired.
46 CFR 180.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2023
Resolution: Received photographic evidence of replaced batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 8 November 2022
Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free. Lines for rescue boats obstructed ability for life floats to float free.
46 CFR 180.130(a)(2)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2022
Resolved 9 December 2022
Resolution: Lines that secure the John boats were rerouted to allow for the life floats to float free.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 8 November 2022
Resolved
The float-free link required by § 180.130(a)(1) must be: Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant. Float-free link for each life float was missing tag certifying approval.
46 CFR 180.137(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2022
Resolution: 02 new Jim-Buoy weak links were installed on life float lines. Tags were removed and placed in zip lock bag for future inspection without the possibility of deterioration from the environment and loss.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 November 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2022
Resolution: New license was onboard and current.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 November 2022
Resolved
The equipment required for life floats and buoyant apparatus must meet the following specifications: Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Paddles were not lashed to each life float.
46 CFR 180.175(f)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2022
Resolution: Paddles were serviced and re-attached to the float.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 8 November 2022
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Vessel had excess engine oil stored in engine room. Remove excess oil or fill storage tank on vessel.
46 CFR 176.830(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Oil was removed from the deckplates and added to the storage tank.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 8 November 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel could not provide satisfactory proof of random drug test program for all crewmembers.
46 CFR 16.230(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Documentary evidence was reviewed with crewmembers names.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 November 2022
Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. EPRIB registration with NOAA was expired. Vessel is limited to operation up to 3nm offshore.
47 CFR 80.1061(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 December 2022
Resolution: NOAA registration was presented for inspection and sticker were installed on their EPIRB.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 November 2022
Resolved
The master of the vessel shall ensure that: Each EPIRB, other than an EPIRB in an inflatable life raft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Monthly tests of EPIRB were not conducted or logged. Provide documentary evidence of updated log inspections to Marine Inspector.
46 CFR 185.728(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Master of vessel has presented a new logbook to record maintenance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 November 2022
Resolved
Portable extinguishers must be inspected monthly as required by NFPA 10 conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly inspections of portable fire extinguishers were not conducted. Provide documentary evidence of updated log inspections to Marine Inspector.
46 CFR 176.810(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Master of vessel has presented a new logbook to record maintenance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 November 2022
Resolved
Abandon ship and man overboard drills and training, firefighting drills and training, and inspection and maintenance of survival craft shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel log was missing abandon ship and man overboard drills and training, firefighting drills and training, and inspection and maintenance of survival craft. Provide documentary evidence of updated logs to the Marine Inspector.
46 CFR 185.520(f)
46 CFR 185.524(d)
46 CFR 185.702(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Master of vessel has presented a new logbook to record drills. Conducted man overboard, fire and abandon ship drill.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 November 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First kit onboard had expired contents. Replace aspirin and eye wash in first aid kit.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: New first aid kit was made available.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 November 2022
Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these Rules. Vessel was missing Inland Navigation Rules.
33 CFR 83.01(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Inland navigation rules were provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 November 2021
Resolved
The EPIRB test required by 46 CFR 180.64 shall be logged or otherwise documented, as applicable. The EPIRB registration document from NOAA was missing. Replace current registration documentation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 1 December 2021
Resolution: Upadted EPIRB registration form submitted. Picture attached.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 November 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. No up to date publications were found onboard. Replace required publications with current editions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 1 December 2021
Resolution: New publications received. Picture uploaded.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 November 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 02 life-rings found with deteriorated markings and 01 found with deteriorated retroreflective material. Repair deteriorated markings and type II retroreflective material.
46 CFR 176.808
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 1 December 2021
Resolution: Lettering and retroreflective material repaired. Picture attached.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 November 2020
Resolved
Inspection and maintenance of lifesaving equipment shall be logged. Found no record of inspection or maintenance. Perform required maintenance and inspections and update/create log.
Action required: 10 - Deficiency Rectified
Due 9 November 2020
Resolved 9 November 2020
Resolution: Created log IAW applicable regulations.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 November 2020
Resolved
The owner or managing operator must provide evidence of required servicing and inspection of firefighting equipment. Found no record of monthly inspection of portables IAW NFPA 10. Perform inspection and update/create log.
Action required: 10 - Deficiency Rectified
Due 9 November 2020
Resolved 9 November 2020
Resolution: Created a log IAW applicable regulations.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 November 2020
Resolved
Type 1 EPIRB battery must be replaced after use or prior to battery expiration. Found battery expired. Replace battery. Vessel restricted to not more than 3 miles from shore until rectified.
Action required: 705 - Other - as specified
Resolved 9 December 2020
Resolution: Replaced battery.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 November 2020
Resolved
Each survival craft must be in good working order. Found 02 bouyant apparatus in unrepairable condition. Replace with acceptable survival craft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2020
Resolution: Installed 2 new 12 person life floats with approval number 161.010.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 November 2020
Resolved
Crew drills must be performed and logged at least once every three months. Found log not updated with no drills logged in the last year. Perform required drills and update log.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2020
Resolution: Produced acceptable log to record required drills, maintenance, and inspections.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 September 2019
Resolved
W/T door has a soft (weather tight) gasket installed. 170.270(b)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2019
Resolution: owner installed new gasket and tested.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 17 September 2019
Resolved
E- lights had 34 V bulbs in a 24 V system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2019
Resolution: Correct bulbs installed
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 17 September 2019
Resolved
Aft deck speaker not working and no speakers provided for crew and passenger compartments.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2019
Resolution: O/O fixed FWD most speaker. Witnessed op test of speaker.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 September 2019
Resolved
Conduct and log drills correctly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2019
Resolution: Conducted drills with crew.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 September 2019
Resolved
No public address speaker in 4 person berthing aft. Space not to be used as accommodations until PA speaker is installed and tested .
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 26 September 2019
Resolution: O/O installed a PA speaker near the AFT berthing area. Witnessed op test of speaker.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2019
Resolved
No spanner wrench for fire hose
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 August 2019
Resolution: Owner purchased new spanner wrench
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 1 August 2019
Resolved
Alcohol test strips expired
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 August 2019
Resolution: Owner purchased new test strips
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2019
Resolved
Emergency escape hatch markings on bow are worn
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2019
Resolution: Verified Owner repainted markings
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 June 2017
Resolved
Relabel child and adult area storage IAW 46 CFR 180.78
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: VSL purchased an additional child size lifejacket rather than relabel the stowage to equal the 04.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 June 2017
Resolved
01 life float water light bulb looks broke but working needs repaired IAW 46 CFR 180.205
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: VSL replaced waterlight.
Lifesaving › Lifefloat › Markings
Issued 26 June 2017
Resolved
Apply SOLAS tape to life float and life ring buoy IAW 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: SOLAS tape was replaced with new.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 26 June 2017
Resolved
Input MMSI into radio IAW 47 CFR 80
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 26 June 2017
Resolved
Remove soiled rags from pilothouse console IAW 46 CFR 176.80
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: Soiled rags were removed and replaced with clean.
Communications › Public Address System › Broadcast Location
Issued 26 June 2017
Resolved
Add additional public address speaker to aft berthing area IAW 46 CFR 184.610
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 June 2017
Resolved
Provide light list, tide /current table, and navigation rules IAW 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: Current pubs were available for inspection.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 26 June 2017
Resolved
Provide proof of DAPI supervisor training IAW 46 CFR 16.401
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 June 2017
Resolved
Log EPIRB inspection, fire, man overboard, rough weather, and abandon ship drills IAW 46 CFR 185.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Fire Fighting › Fire Pumps › Impeller
Issued 26 June 2017
Resolved
Make fire pump not leak IAW 46 CFR 181.300
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 June 2017
Resolved
Secure wiring in engine room with metallic hangers or adel type clamps IAW 46 CFR183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 26 June 2017
Resolved
Remove vent hose from hydraulic tank IAW 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: Hose was secured with a clamp.
Accommodation/Occupational Safety › Potable Water System › General
Issued 26 June 2017
Resolved
Provide adequate vent pipe covering for potable water pipes IAW 46 CFR 182.458
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: Vents were fitted with mesh screens.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 June 2017
Resolved
Replace hydro static release on EPIRB IAW 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: Hydrostatic release was replaced and marked accordingly.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 July 2016
Resolved
Vessel did not have alcohol testing devices. Provide approved alcohol testing devices. Vessel is restricted to voyages of no more than 2 hrs until provided with means to conduct alcohol testing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 26 July 2016
Resolution: Provided approved alcohol testing devices.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 July 2016
Resolved
Provide updated copies of publications light list and navigation rules.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 26 July 2016
Resolution: Provided updated pubs.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 July 2016
Resolved
The emergency lighting in crew accommodation space and ENG room was not operable make operable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 26 July 2016
Resolution: Proved proper operation of emergency lighting.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 July 2016
Resolved
Install emergency lighting in fwd accommodation space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 26 July 2016
Resolution: Installed new lighting fixture in stairwell that properly illuminates path of egress from berthing areas.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 13 July 2016
Resolved
Provide Employee Assistance Program training and certificate for crew and master.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 11 August 2016
Resolution: Provided documentation of completion of required EAP training for crew.