MAURY USCG vessel records Sign in
← All vessels

I'M ALONE

I'M ALONE is a 1978 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1982, most recently in April 2026, along with 210 deficiencies and 2 casualty investigations between 2009 and 2024.

Records from 1982 to 2026. Most recent: inspection, 3 April 2026.

Built
1978
Last inspected
3 April 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG5758
Flag
UNITED STATES
367549960
Maury page id
psix-53943

Inspections, by type

…with no type recorded9
Years with a record 40 calendar years (1982–2026)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)68.7 ft × 21.4 ft × 9.0 ft
Registered tonnagegross 89 / net 61
ITC dimensions (L × B × D)68.7 ft × 21.4 ft × 9.0 ft
ITC tonnagegross 97 / net 29
BuilderGRAHAM BOATS INC · PASCAGOULA, MS, UNITED STATES · built 1978
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPASCAGOULA, MS
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Convention (Subpart B), Gross Ton
89 - Regulatory (Subpart C or D), Gross Ton
29 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG5758MMSI 367549960 · active · compulsorily equipped · granted 30 September 2022, expires 16 October 2032
WDA9310MMSI 366863780 · expired · voluntarily equipped · granted 31 July 2002, cancelled 6 October 2012
WUR7223MMSI not assigned · expired · compulsorily equipped · granted 2 May 1996, cancelled 17 June 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 88

3 April 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8341583
3 December 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8268296
1 August 2024 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7972288
31 July 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7975169
30 July 2024 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7989398
1 November 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7824006
27 October 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7815397
9 March 2023 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648494
28 October 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7585505
28 July 2022 Hull Examination · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7523950
3 June 2022 Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 7472143
1 December 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7379211
27 October 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7340915
4 November 2020 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7089839
23 July 2020 Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7018454
17 September 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814281
26 July 2019 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6763344
2 August 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6499169
15 June 2018 Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6445276
10 July 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6205238
14 June 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6176109
30 March 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6114669
10 January 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6068911
11 August 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5969800
8 August 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5966259
26 July 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5954647
1 July 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5925664
4 April 2016 Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5853554
6 May 2014 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4843908
30 July 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3568409
19 March 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3433012
25 February 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3423472
24 June 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3228352
12 March 2008 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3163206
5 July 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2992719
22 February 2007 COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2875624
19 June 2006 Damage Survey · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2726843
20 March 2006 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2605673
24 February 2006 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2608985
3 November 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2538587
14 April 2005 Annual Inspection · Deficiency Check
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2333128
23 June 2004 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2108153
23 June 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2108610
5 April 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2049443
12 March 2004 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2014448
1 March 2004 Administrative Inspection · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2015679
24 February 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1742791
8 August 2002 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1636035
17 May 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1617879
26 March 2002 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1493051
5 April 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1061552
29 March 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1061525
10 October 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1055210
1 September 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1405042
15 April 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1053260
15 March 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1047033
10 May 1999 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 795888
31 March 1999 COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1442804
2 September 1998 Deficiency Check · Hull Examination · Re-Inspection · Drydock Extension
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1462704
24 April 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1099205
28 March 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421296
15 April 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1080404
11 March 1996 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392421
10 July 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1185126
4 April 1995 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1396290
13 April 1994 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 858729
15 March 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 833623
26 March 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1265474
23 March 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1265592
7 May 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1212927
25 April 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 899400
14 March 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1223836
26 February 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 912270
29 March 1990 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1233641
28 September 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1313172
16 August 1989 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 890955
31 March 1989 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1040241
28 March 1988 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 992532
26 March 1987 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1020563
26 March 1987 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1327550
14 January 1987 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1009262
31 March 1986 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1307802
27 August 1985 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 988678
18 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 978019
6 November 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1283577
23 April 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973476
22 April 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277963
6 May 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274878

Deficiency record · 210

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 April 2026 Resolved
Except as provided by § 15.725, no vessel may be navigated unless it has in its service and onboard the crew complement required by the COI. Vessel has insufficient manning in accordance with COI. Prior to operating, vessel must prove adequate manning and conduct satisfactory drills in the presence of a Marine Inspector. 46 CFR 15.515(a)
Action required: 705 - Other - as specified
Resolved 3 April 2026
Resolution: Mate was medically cleared and returned on board vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 December 2025 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Hydrostatic release for EPIRB was expired. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2026
Resolution: New hydrostatic release installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 December 2025 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. 02 smoke detectors in the overnight accommodation space were giving error codes and were being replaced. 46 CFR 181.405
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2026
Resolution: New smoke detctors installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 December 2025 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. 02 water light batteries were expired. 46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2025
Resolution: Received satisfactory evidence of new life float light batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2025 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter. 02 life jacket lights inop 46 CFR 185.75
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2025
Resolution: Received satisfactory evidence of new life jacket lights
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 December 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List; Tide tables. Vessel publications were not up to date. 46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 6 January 2026
Resolution: Owner obtained new publications.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 December 2025 Resolved
Fire fighting and abandon ship drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel had not logged any drills in over a year. Provided vessel with log booklet. 46 CFR 185.524(d)(1)(2) 46 CFR 185.520(f)(1)(2)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2025
Resolution: Provided vessel with booklet to log drills
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 December 2025 Resolved
The master of the vessel shall ensure that the EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel did not have a log of monthly EPIRB tests. Conducted satisfactory test of EPIRB and provided vessel with log booklet. 46 CFR 185.728(c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2025
Resolution: Conducted satisfactory test of EPIRB and provided vessel with booklet to log maintenance
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 August 2024 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Upon inspection, MI determined vessel was not ready for inspection. Ensure vessel is in compliance and reschedule inspection at a later date.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2024
Resolution: Vessel had succesful COI inspection conducted by MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Inspection found blank spot where breaker was removed from electrical panel in the engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 23 September 2024
Resolution: Replacedf blank in breaker panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Inspection found degraded reflective tape on life rings and life floats.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 25 September 2024
Resolution: O/O Submitted photographic evidenc of SOLAS tape replacement, ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply line and... shall be operable from outside the tank compartment. Fuel valve servicing the port fuel tank has wire buckle that is catching on the deck plate not allowing the valve to actuate closed. Make repairs to enable the valve to be fully operable.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 7 November 2023
Resolution: Received documentary evidence of proper operation of fuel shut off valves.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 November 2023 Resolved
Each vessel on an Oceans service must have an approved EPIRB, that is stowed in a manner that makes it capable of being float free if the vessel sinks. The hydrostatic release for the EPIRB is expired. Install a unexpired hydrostatic release and mark expiration date upon installation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 7 November 2023
Resolution: Received documentary evidence of properly marked and installed hydrostatic release.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 November 2023 Resolved
Vessel does not have an interconnected smoke detection and alarm system. Vessels on a Coast wise or Oceans route must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. § 181.450: An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217. (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) to be protected by the interconnected detection and alarm system; (3) Contain an independent power source; and (4) Alarm on low power. Provide evidence to the local OCMI that an interconnected detection system meeting the above requirements has been installed and is functional.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 11 January 2024
Resolution: Vessel installed interconnected fire detecition system. Inspected and tested intercnooected fire detection system, all SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 1 November 2023 Resolved
Except as otherwise provided, each space accessible to passengers or used by the crew on a regular basis, must have two means of escape... and must be capable of being opened by one person from either side. Vessel's forward escape hatch is only capable of being opened from inside the cabin. Make hatch capable of opening from both sides prior to 27DEC23.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 November 2023
Resolved 11 January 2024
Resolution: Vessel installed nre escape hatch, the hatch was opened from both the inside and outside, SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 November 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. 01 smoke detectors were expired. No overnight passengers until detector is replaced. 46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 December 2022
Resolution: New smoke detector was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 November 2022 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. 02 batteries from each life float were expired. 46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2023
Resolution: Received photographic evidence of replaced batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 November 2022 Resolved
Each floating water light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant. 02 batteries from ring life buoy water lights were expired. 46 CFR 180.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 February 2023
Resolution: Received photographic evidence of replaced batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 8 November 2022 Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free. Lines for rescue boats obstructed ability for life floats to float free. 46 CFR 180.130(a)(2)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2022
Resolved 9 December 2022
Resolution: Lines that secure the John boats were rerouted to allow for the life floats to float free.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 8 November 2022 Resolved
The float-free link required by § 180.130(a)(1) must be: Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant. Float-free link for each life float was missing tag certifying approval. 46 CFR 180.137(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2022
Resolution: 02 new Jim-Buoy weak links were installed on life float lines. Tags were removed and placed in zip lock bag for future inspection without the possibility of deterioration from the environment and loss.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 November 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2022
Resolution: New license was onboard and current.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 November 2022 Resolved
The equipment required for life floats and buoyant apparatus must meet the following specifications: Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Paddles were not lashed to each life float. 46 CFR 180.175(f)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2022
Resolution: Paddles were serviced and re-attached to the float.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 8 November 2022 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Vessel had excess engine oil stored in engine room. Remove excess oil or fill storage tank on vessel. 46 CFR 176.830(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Oil was removed from the deckplates and added to the storage tank.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 8 November 2022 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel could not provide satisfactory proof of random drug test program for all crewmembers. 46 CFR 16.230(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Documentary evidence was reviewed with crewmembers names.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 November 2022 Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. EPRIB registration with NOAA was expired. Vessel is limited to operation up to 3nm offshore. 47 CFR 80.1061(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 December 2022
Resolution: NOAA registration was presented for inspection and sticker were installed on their EPIRB.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 November 2022 Resolved
The master of the vessel shall ensure that: Each EPIRB, other than an EPIRB in an inflatable life raft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Monthly tests of EPIRB were not conducted or logged. Provide documentary evidence of updated log inspections to Marine Inspector. 46 CFR 185.728(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Master of vessel has presented a new logbook to record maintenance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 November 2022 Resolved
Portable extinguishers must be inspected monthly as required by NFPA 10 conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly inspections of portable fire extinguishers were not conducted. Provide documentary evidence of updated log inspections to Marine Inspector. 46 CFR 176.810(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Master of vessel has presented a new logbook to record maintenance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 November 2022 Resolved
Abandon ship and man overboard drills and training, firefighting drills and training, and inspection and maintenance of survival craft shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel log was missing abandon ship and man overboard drills and training, firefighting drills and training, and inspection and maintenance of survival craft. Provide documentary evidence of updated logs to the Marine Inspector. 46 CFR 185.520(f) 46 CFR 185.524(d) 46 CFR 185.702(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Master of vessel has presented a new logbook to record drills. Conducted man overboard, fire and abandon ship drill.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 November 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First kit onboard had expired contents. Replace aspirin and eye wash in first aid kit. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: New first aid kit was made available.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 November 2022 Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these Rules. Vessel was missing Inland Navigation Rules. 33 CFR 83.01(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 7 December 2022
Resolution: Inland navigation rules were provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 November 2021 Resolved
The EPIRB test required by 46 CFR 180.64 shall be logged or otherwise documented, as applicable. The EPIRB registration document from NOAA was missing. Replace current registration documentation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 1 December 2021
Resolution: Upadted EPIRB registration form submitted. Picture attached.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 November 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. No up to date publications were found onboard. Replace required publications with current editions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 1 December 2021
Resolution: New publications received. Picture uploaded.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 November 2021 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 02 life-rings found with deteriorated markings and 01 found with deteriorated retroreflective material. Repair deteriorated markings and type II retroreflective material. 46 CFR 176.808
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 1 December 2021
Resolution: Lettering and retroreflective material repaired. Picture attached.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 November 2020 Resolved
Inspection and maintenance of lifesaving equipment shall be logged. Found no record of inspection or maintenance. Perform required maintenance and inspections and update/create log.
Action required: 10 - Deficiency Rectified
Due 9 November 2020
Resolved 9 November 2020
Resolution: Created log IAW applicable regulations.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 November 2020 Resolved
The owner or managing operator must provide evidence of required servicing and inspection of firefighting equipment. Found no record of monthly inspection of portables IAW NFPA 10. Perform inspection and update/create log.
Action required: 10 - Deficiency Rectified
Due 9 November 2020
Resolved 9 November 2020
Resolution: Created a log IAW applicable regulations.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 November 2020 Resolved
Type 1 EPIRB battery must be replaced after use or prior to battery expiration. Found battery expired. Replace battery. Vessel restricted to not more than 3 miles from shore until rectified.
Action required: 705 - Other - as specified
Resolved 9 December 2020
Resolution: Replaced battery.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 November 2020 Resolved
Each survival craft must be in good working order. Found 02 bouyant apparatus in unrepairable condition. Replace with acceptable survival craft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2020
Resolution: Installed 2 new 12 person life floats with approval number 161.010.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 November 2020 Resolved
Crew drills must be performed and logged at least once every three months. Found log not updated with no drills logged in the last year. Perform required drills and update log.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2020
Resolution: Produced acceptable log to record required drills, maintenance, and inspections.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 September 2019 Resolved
W/T door has a soft (weather tight) gasket installed. 170.270(b)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2019
Resolution: owner installed new gasket and tested.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 17 September 2019 Resolved
E- lights had 34 V bulbs in a 24 V system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2019
Resolution: Correct bulbs installed
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 17 September 2019 Resolved
Aft deck speaker not working and no speakers provided for crew and passenger compartments.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2019
Resolution: O/O fixed FWD most speaker. Witnessed op test of speaker.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 September 2019 Resolved
Conduct and log drills correctly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2019
Resolution: Conducted drills with crew.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 September 2019 Resolved
No public address speaker in 4 person berthing aft. Space not to be used as accommodations until PA speaker is installed and tested .
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 26 September 2019
Resolution: O/O installed a PA speaker near the AFT berthing area. Witnessed op test of speaker.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2019 Resolved
No spanner wrench for fire hose
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 August 2019
Resolution: Owner purchased new spanner wrench
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 1 August 2019 Resolved
Alcohol test strips expired
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 August 2019
Resolution: Owner purchased new test strips
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2019 Resolved
Emergency escape hatch markings on bow are worn
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2019
Resolution: Verified Owner repainted markings
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 June 2017 Resolved
Relabel child and adult area storage IAW 46 CFR 180.78
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: VSL purchased an additional child size lifejacket rather than relabel the stowage to equal the 04.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 June 2017 Resolved
01 life float water light bulb looks broke but working needs repaired IAW 46 CFR 180.205
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: VSL replaced waterlight.
Lifesaving › Lifefloat › Markings
Issued 26 June 2017 Resolved
Apply SOLAS tape to life float and life ring buoy IAW 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: SOLAS tape was replaced with new.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 26 June 2017 Resolved
Input MMSI into radio IAW 47 CFR 80
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 26 June 2017 Resolved
Remove soiled rags from pilothouse console IAW 46 CFR 176.80
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: Soiled rags were removed and replaced with clean.
Communications › Public Address System › Broadcast Location
Issued 26 June 2017 Resolved
Add additional public address speaker to aft berthing area IAW 46 CFR 184.610
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 June 2017 Resolved
Provide light list, tide /current table, and navigation rules IAW 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: Current pubs were available for inspection.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 26 June 2017 Resolved
Provide proof of DAPI supervisor training IAW 46 CFR 16.401
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 June 2017 Resolved
Log EPIRB inspection, fire, man overboard, rough weather, and abandon ship drills IAW 46 CFR 185.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Fire Fighting › Fire Pumps › Impeller
Issued 26 June 2017 Resolved
Make fire pump not leak IAW 46 CFR 181.300
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 June 2017 Resolved
Secure wiring in engine room with metallic hangers or adel type clamps IAW 46 CFR183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 July 2017
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 26 June 2017 Resolved
Remove vent hose from hydraulic tank IAW 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: Hose was secured with a clamp.
Accommodation/Occupational Safety › Potable Water System › General
Issued 26 June 2017 Resolved
Provide adequate vent pipe covering for potable water pipes IAW 46 CFR 182.458
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: Vents were fitted with mesh screens.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 June 2017 Resolved
Replace hydro static release on EPIRB IAW 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 10 July 2017
Resolution: Hydrostatic release was replaced and marked accordingly.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 July 2016 Resolved
Vessel did not have alcohol testing devices. Provide approved alcohol testing devices. Vessel is restricted to voyages of no more than 2 hrs until provided with means to conduct alcohol testing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 26 July 2016
Resolution: Provided approved alcohol testing devices.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 July 2016 Resolved
Provide updated copies of publications light list and navigation rules.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 26 July 2016
Resolution: Provided updated pubs.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 July 2016 Resolved
The emergency lighting in crew accommodation space and ENG room was not operable make operable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 26 July 2016
Resolution: Proved proper operation of emergency lighting.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 July 2016 Resolved
Install emergency lighting in fwd accommodation space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 26 July 2016
Resolution: Installed new lighting fixture in stairwell that properly illuminates path of egress from berthing areas.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 13 July 2016 Resolved
Provide Employee Assistance Program training and certificate for crew and master.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 11 August 2016
Resolution: Provided documentation of completion of required EAP training for crew.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 February 2009 Resolved
Provide and install guard for fire pump motor as per 46 CFR 177.960
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 19 March 2009
Resolution: Adequate guards provided.
Fire Fighting › Fire Hoses › Condition
Issued 25 February 2009 Resolved
Provide and install hose gaskets in nozzles and fire hoses as per 46 CFR 176.800
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 19 March 2009
Resolution: Hose gaskets installed on both nozzles and hoses.
Fire Fighting › Nozzles › Condition
Issued 25 February 2009 Resolved
Prove proper operation of fire nozzle as per 46 CFR 181.320(d)
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 19 March 2009
Resolution: Proper nozzle provided.
Fire Fighting › Fire Pumps › Pressure
Issued 25 February 2009 Resolved
Prove fire pump meets requirements of 46 CFR 181.300(b)
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 19 March 2009
Resolution: Fire pump does meet said requirements.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 February 2009 Resolved
Perform maintainence on batteries.
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 19 March 2009
Resolution: Batteries were cleaned and proper maintence preformed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 February 2009 Resolved
Provide and install closure device for sonar junction box as per 46 CFR 183.330
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 19 March 2009
Resolution: Closure device added.
Electrical › Electrical Distribution System (service) › Cable
Issued 25 February 2009 Resolved
Properly support cables in lazarette as per 46 CFR 183.340(b)(4)
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 19 March 2009
Resolution: Cables supported with metal brackets.
Electrical › Electrical Distribution System (service) › Cable
Issued 25 February 2009 Resolved
Provide and install grommet at electrical connect for fresh water pump as per 46 CFR 183.340(g)
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 19 March 2009
Resolution: Grommet installed.
Operations/Management › Passenger Operations › Safety Orientation
Issued 25 February 2009 Resolved
Prove stowage and operation of skiffs.
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 19 March 2009
Resolution: Four skiffs were onboard; vessel rep states that the other three are towed to fishing grounds.
Lifesaving › Lifefloat › Netting
Issued 24 June 2008 Resolved
Replace the two deteriorated life floats. The vessel can not carry passenger until the life floats are replaced or repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2008
Resolved 27 June 2008
Resolution: Two new life floats were purchased and place onboard.
Engineering › Freshwater System (cylinder head cooling) › Valve
Issued 24 June 2008 Resolved
Make repairs to the expansion tank valve by providing a valve handle or replace the valve.
Action required: 705 - Other - as specified
Due 24 July 2008
Resolved 27 June 2008
Resolution: A valve handle was installed on the valve.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 June 2008 Resolved
Provide a blank cover for the opening in the front of the switchboard.
Action required: 705 - Other - as specified
Due 24 July 2008
Resolved 27 June 2008
Resolution: A cover was install over the opening.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 24 June 2008 Resolved
Prove proper operation of the lights on the life jackets and the proper number of life jackets.
Action required: 705 - Other - as specified
Due 24 July 2008
Resolved 27 June 2008
Resolution: New lights were purchased and installed on the life jackets and the correct number of lifejackets was verified.
Construction/Loadline › Penetrations › Valve Flange
Issued 12 March 2008 Resolved
Make all valves for the through hull penetrations ready for inspection
Due 7 April 2008
Resolved 25 March 2008
Resolution: The through hull penetration and valve was visually examined with satisfactory results.
Engineering › Bilge Water Management System › Piping
Issued 12 March 2008 Resolved
Make repairs to the deteriorated bilge suction piping for the forepeak located in the midbody void.
Due 7 April 2008
Resolved 25 March 2008
Resolution: The deteriorated bilge suction piping for the forepeak located in the midbody void was repaired
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 March 2008 Resolved
Crop and renew the deteriorated bulkhead between the two live well tanks.
Due 7 April 2008
Resolved 25 March 2008
Resolution: The deteriorated bulkhead between the two live well tanks was removed and a new structural member was added to reinforce the above decking. The tank is now a void tank this was all approved by the CID.
Construction/Loadline › Hull › Bottom Plating
Issued 12 March 2008 Resolved
Crop and renew the hull bottom plate in way of the 6" hole in the stern void.
Due 7 April 2008
Resolved 25 March 2008
Resolution: The hull plate in way of the 6" hole in the stern void port side was inserted with a 18" X 18" plate and satisfactorily tested with a vacbox..
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 March 2008 Resolved
Remove the oil from the engine bilge.
Due 7 April 2008
Resolved 25 March 2008
Resolution: The oil in the engine bilge was removed.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 12 March 2008 Resolved
Make repairs to the damaged port propeller.
Due 12 April 2008
Resolved 25 March 2008
Resolution: Repairs were made to the damaged port propeller.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 26 March 2007 Resolved
Prove the operating capacity of the main breaker at the switchboard in the engine room in accordance with 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 26 April 2007
Resolved 5 July 2007
Resolution: Proved the operating capacity of the main breaker at the switchboard in the engien room as per 46 CFR 183.330.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 22 February 2007 Resolved
Provide retro-reflective tape to the lifejackets where needed in accordance with 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 26 March 2007
Resolution: Provided retro-reflective tape to the lifejackets where needed in accordance with 46 CFR 185.604.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 February 2007 Resolved
Conduct man overboard, fire fighting and abandon ship drills in the presence of a Coast Guard Marine Inspector in accordance with 46 CFR 185.520 and 185.524.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 26 March 2007
Resolution: Conducted man overboard, fire fighting and abandon ship drills in the presence of a Coast Guard Marine Inspector in accordance with 46 CFR 185.520 and 185.524.
Electrical › Electric Generation Source (service) › Generator
Issued 22 February 2007 Resolved
Prove that generators have been de-rated in accordance with 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 26 March 2007
Resolution: Generator''s does not need to be de-rated as the ambient temperature in the engine room does not exceed 40 C.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 22 February 2007 Resolved
Provide a cap for the drain line coming off the lube oil tank in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 26 March 2007
Resolution: Provided a cap for the drain line coming off the lube oil tank in accordance with 46 CFR 176.800.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2007 Resolved
Remove dead end wires in the mid ship bilge in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 26 March 2007
Resolution: Removed dead end wires in the mid ship bilge in accordance with 46 CFR 183.340.
Electrical › Electric Generation Source (service) › Generator
Issued 20 March 2006 Resolved
Remove dirt and oil from the generator windings as required by 46 CFR 176.806.
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 10 August 2006
Resolution: Removed dirt and oil from the generator windings as required by 46 CFR 176.806.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 March 2006 Resolved
Provide cover for exposed moving parts on port generator as required by 46 CFR 177.960
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 10 August 2006
Resolution: Provided cover for exposed moving parts on port generator as required by 46 CFR 177.960.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 March 2006 Resolved
Provide a cover for the upper bank of batteries in the aft port side of the engine room as required by 46 CFR 183.354
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 10 May 2006
Resolution: Provided cover for battery for bank.
Documentation › Markings/Placards › Warning Signs
Issued 20 March 2006 Resolved
Mark emergency escape hatch for engine room as required by 46 CFR 185.606
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 10 May 2006
Resolution: Marked emergency escape hatch.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 20 March 2006 Resolved
Replace cracked port lights: One on starboard side and one on port side, as required by 46 CFR 176.802
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 10 May 2006
Resolution: Replaced port light glass.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 20 March 2006 Resolved
Prove proper operation of the electronic position fixing device as required by 46 CFR 184.410
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 10 May 2006
Resolution: Proved operation of electronic position fixing device.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 20 March 2006 Resolved
Provide a current copy of tide tables and tidal currents as required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 10 May 2006
Resolution: Provided a current copy of tide tables and tidal currents.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 20 March 2006 Resolved
Provide oil containment trays for under the engines to contain the oil leaks from engines to meet the requirements of 33 CFR 155.770
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 10 August 2006
Resolution: Provided oil containment trays for under the engines to contain the oil leaks from engines to meet the requirements of 33 CFR 155.70.
Electrical › Electric Supply System (service) › Cable
Issued 14 April 2005 Resolved
Properly install the electrical cables in the shore tie disconnect box (engine room)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2005
Resolved 16 May 2005
Resolution: Cables were rerouted and properly installed.
Fire Fighting › Fire Pumps › Arrangement
Issued 14 April 2005 Resolved
Fire pump local controller does not work (Remote operating switch does start the fire pump).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2005
Resolved 16 May 2005
Resolution: Local fire pump controller was replaced and tested to the satifaction of the attending Marine Inspector.
Engineering › Lubricating Oil Service System › Pump
Issued 14 April 2005 Resolved
The hydraulic pump motor shaft guard is missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2005
Resolved 16 May 2005
Resolution: Guard was installed around the shaft.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2005 Resolved
The first kit has expired Meds.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 May 2005
Resolved 16 May 2005
Resolution: A new first kit was provided.
Electrical › Electric Supply System (service) › Cable
Issued 14 April 2005 Resolved
Properly install electrical conductors in the shore power electrical disconnection box (engine room).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2005
Resolved 16 May 2005
Resolution: Cable were re-routed and properly installed
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 1 April 2004 Resolved
Provide CPR and first aid cards for 50% of crew IAW NVIC 1-91.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2004
Resolution: Owner/operator provided current documentation of First Aid and CPR.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 April 2004 Resolved
Provide light list containing current correction IAW 46 CFR 184.420
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Current light list provided. Deficiency corrected.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 April 2004 Resolved
Replace conventional type light bulbs with proper navigational bulbs IAW UL 1104 and navigational rules.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Replaced conventional bulbs with proper navigational bulbs. Deficiency corrected.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 1 April 2004 Resolved
Log steering tests and crew drills on a monthly basis IAW 46 CFR 185.702, 46 CFR 185.520 and 46 CFR 185.524.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Provided logs for steering tests, and monthly crew drills. Deficiency corrected.
Lifesaving › Lifeboat Equipment › Oar
Issued 1 April 2004 Resolved
Stencil vessel's name onto paddles for lifefloat IAW 46 CFR 185.604 (g).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Name stenciled on life float oars. Deficiency corrected.
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 1 April 2004 Resolved
Replace delaminated retro-reflective tape on 3 PFDs IAW 46 CFR 185.604 (h).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Replaced retro-reflective tape on identified PFDs. Deficiency corrected.
Fire Fighting › Fire Hoses › Condition
Issued 1 April 2004 Resolved
Replace ruptured fire hose located in engine room IAW 46 CFR 181.320.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Replaced firehose. Deficiency corrected.
Engineering › Bilge Water Management System › Pump
Issued 1 April 2004 Resolved
Provide longer hose for portable bilge pump to reach any compartment for dewatering IAW 46 CFR 182.520 (b)(1).
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Longer hose provided. Deficiency corrected.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 April 2004 Resolved
Replace navigational light fixtures to meet UL standard 1104.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Navigational light replaced. Deficiency corrected.
Documentation › Logs/Records › Drug Test Records
Issued 1 April 2004 Resolved
Provide proof of enrollment for drug audit program IAW 46 CFR 16.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Proof of drug program provided. Deficiency corrected.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 1 April 2004 Resolved
Provide non-conductive mats or grating on deck in front of switchboard IAW 46 CFR 183.10-15 (b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2004
Resolution: Provided non-conductive mat on deck infront of switchboard. Deficiency corrected.
Documentation › Logs/Records
Issued 1 April 2004 Resolved
Commence logging voyage plan and show documentation of such upon request by coast guard marine inspector IAW 46 CFR 185.503-.504.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2004
Resolution: Provided voyange plan and documentation. Deficiency corrected.
Stability › Watertight Integrity › General
Issued 1 March 2004 Resolved
Replace existing door in way of aft accommodation space with a Class I, Quick-Acting Watertight Door as stipulated in the vessel's Stability Letter.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 14 April 2005
Resolution: The door was replaced with a Quick-Acting Watertight Door and tested, test sat.
Stability › Watertight Integrity › General
Issued 1 March 2004 Resolved
Install indicator lights at the operating station showing whether the door is open or closed as required by 46 CFR 179.330(a)(2)(b).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 28 July 2004
Resolution: Attended vsl and operationally tested indicator light. Sat.
Documentation › Certificates/Documents › FCC SSL
Issued 24 February 2003 Resolved
Provide and post FCC Safety Radiotelephony Certificate as required by 46 CFR 184.502 and 47 CFR Part 80.
Due 10 March 2003
Resolved 10 March 2003
Resolution: FCC safety certificate was provided and posted.
Communications › Radio Communications
Issued 24 February 2003 Resolved
Provide and post FCC Marine Operators Permit as required by 46 CFR 184.502 and 47 CFR Part 80. LEGACY COMPONENT DESC: FCC Operator permit
Due 10 March 2003
Resolved 10 March 2003
Resolution: FCC Marine Operators permit obtained.
Documentation › Certificates/Documents
Issued 24 February 2003 Resolved
Post Stability Letter as required by 46 CFR 176.306. LEGACY COMPONENT DESC: Stability Letter
Due 10 March 2003
Resolved 10 March 2003
Resolution: Stability letter was posted.
Documentation › Logs/Records › Logbook (official)
Issued 24 February 2003 Resolved
Provide up to date training entries in training book as required by 46 CFR 185.420.
Condition: Unknown
Due 10 March 2003
Resolved 10 March 2003
Resolution: Training book entries were up dated.
Navigation › Piloting/Steering
Issued 24 February 2003 Resolved
Provide updated Navigation Publications as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Navigation Publications
Due 10 March 2003
Resolved 10 March 2003
Resolution: Updated Navigation publications were obtained.
Navigation › Collision/Grounding Avoidance
Issued 24 February 2003 Resolved
Repair and prove operation of radar to the satisfaction of the attending marine inspector as required by 46 CFR 184.404. LEGACY COMPONENT DESC: Radar
Due 10 March 2003
Resolved 10 March 2003
Resolution: Radar was repaired.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 24 February 2003 Resolved
Provide and post Emergency Instructions as required by 46 CFR 185.510.
Condition: Unknown
Due 10 March 2003
Resolved 10 March 2003
Resolution: Emergency instruction list was posted.
Lifesaving › Hand Flares › Condition
Issued 24 February 2003 Resolved
Renew all outdated distress flaresand smoke signals as required by 46 CFR 180.68.
Due 10 March 2003
Resolved 10 March 2003
Resolution: Flares and Day Smoke Signals were replaced.
Communications › Radio Communications
Issued 24 February 2003 Resolved
Repair and prove operation of required single side band radio to the satisfaction of the attending marine inspector as required by 46 CFR 184.502. LEGACY COMPONENT DESC: Radiotelephone Transveiver (2-4 MHz)
Due 17 March 2003
Resolved 10 March 2003
Resolution: SSB radio was repaired.
Communications › Radio Communications
Issued 24 February 2003 Resolved
Renew expired hydrostatic release to EPIRB to as required 46 CFR 180.64. LEGACY COMPONENT DESC: EPIRB
Due 10 March 2003
Resolved 10 March 2003
Resolution: Hydro-static release was replaced on EPIRB.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 24 February 2003 Resolved
Repair and prove operation of emergency lighting in crew berthing area to the satisfaction of the attending marine inspector as required by 46 CFR 183.432. LEGACY COMPONENT DESC: Emergency lighting
Due 10 March 2003
Resolved 10 March 2003
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 February 2003 Resolved
Each connection to a conductor or terminal part of a conductor for the forward bilge high level alarm must be made within an enclosure in accordance with 46 CFR 183.340(g).
Due 10 March 2003
Resolved 10 March 2003
Electrical › Lighting (service)
Issued 24 February 2003 Resolved
Provide suitable guards for lighting fixtures in crew berthing as per 46 CFR 183.410. LEGACY COMPONENT DESC: Lighting Fixture
Due 10 March 2003
Resolved 10 March 2003
Resolution: Guards placed on lighting fixtures.
Fire Fighting › Fixed Fire Detection System
Issued 24 February 2003 Resolved
Renew and prove operation of smoke detector located in crew berthing area to the satisfaction of the attending marine inspector as required by 46 CFR 181.450. LEGACY COMPONENT DESC: Smoke Detectors
Due 10 March 2003
Resolved 10 March 2003
Resolution: Smoke alarm in crew berthing was replaced.
Fire Fighting › Fixed Fire Detection System
Issued 24 February 2003 Resolved
Install smoke/fire detector in Galley as required by 46 CFR 181.400. LEGACY COMPONENT DESC: Smoke Detectors
Due 10 March 2003
Resolved 10 March 2003
Resolution: Smoke Detector installed inGalley.
Fire Fighting › Fixed Fire Detection System
Issued 24 February 2003 Resolved
Repair or renew smoke detector in the Captains stateroom and prove operation to the satisfaction of the attending marine inspector as required by 46 CFR 181.450. LEGACY COMPONENT DESC: Smoke Detectors
Due 10 March 2003
Resolved 10 March 2003
Resolution: Smoke alarm in Captains state room was repaired.
Fire Fighting › Firemans Outfit
Issued 24 February 2003 Resolved
Mount fire axe near operating station and mark with vessel name in accordance with 46 CFR 181.600. LEGACY COMPONENT DESC: Axe
Due 10 March 2003
Resolved 10 March 2003
Resolution: Fire Axe was mounted.
Electrical › Electrical Distribution System (service)
Issued 24 February 2003 Resolved
Provide cover for electrical junction box in aft part of engine room overhead as per 46 CFR 183.340. LEGACY COMPONENT DESC: Junction Box
Due 10 March 2003
Resolved 10 March 2003
Resolution: Cover placed on Junction Box.
Engineering › Fuel Oil Service System
Issued 8 August 2002 Resolved
Plug fuel oil tank petcock lines on engine room tank. LEGACY COMPONENT DESC: Piping
Due 15 August 2002
Resolved 15 August 2002
Engineering › Fuel Oil Service System › Piping
Issued 8 August 2002 Resolved
Plug fuel oil petcock on drain lines aft of generator sets in bilges.
Due 15 August 2002
Resolved 15 August 2002
Construction/Loadline › Structures
Issued 8 August 2002 Resolved
Repair gasket on fore peak hatch. LEGACY COMPONENT DESC: Manhole
Due 15 August 2002
Resolved 15 August 2002
Accommodation/Occupational Safety › Washroom/Toilet
Issued 8 August 2002 Resolved
Replace hot water heater starboard side. LEGACY COMPONENT DESC: Hot and Cold Running Water
Due 15 August 2002
Resolved 15 August 2002
Electrical › Electrical Distribution System (service)
Issued 8 August 2002 Resolved
Repair wiring on control panel above port engine LEGACY COMPONENT DESC: Switchboard
Due 15 August 2002
Resolved 15 August 2002
Communications › Radio Communications
Issued 22 March 2002 Resolved
Provide FCC documentation as required by 47CFR part 180.
Due 22 April 2002
Resolved 16 May 2002
Resolution: CG 835 extension was requested for this item.
Navigation › Piloting/Steering
Issued 22 March 2002 Resolved
Provide current navigation pubs "light list" as required by 46CFR 184.470 and 46CFR parts 166-199. LEGACY COMPONENT DESC: Coast Guard Light List
Due 22 April 2002
Resolved 26 March 2002
Stability › Watertight Integrity
Issued 22 March 2002 Resolved
Replace gasket on emergency escape hatch.
Due 22 April 2002
Resolved 16 May 2002
Resolution: CG 835 was requested for this item.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 22 March 2002 Resolved
Have fire extinguisher in accomadation space annually serviced. Worklist item.
Condition: Improper/Lack of Maintenance
Due 22 April 2002
Resolved 26 March 2002
Fire Fighting › Fire Main
Issued 22 March 2002 Resolved
Repair firemain piping as required by 46CFR 181.310. (Work list item)
Due 22 April 2002
Resolved 26 March 2002
Stability › Watertight Integrity
Issued 22 March 2002 Resolved
Replace hatch to accomodation space. (Worklist item)
Condition: Improper/Lack of Maintenance
Due 22 May 2002
Resolved 26 March 2002
Construction/Loadline
Issued 22 March 2002 Resolved
Replace rotted plywood decking entrance into aft accomodation space. (Worklist item)
Due 22 April 2002
Resolved 26 March 2002
Electrical › Lighting (emergency)
Issued 22 March 2002 Resolved
Repair engine rm emergency light. (Worklist item)
Due 22 April 2002
Resolved 26 March 2002
Fire Fighting › Fire Hydrants
Issued 22 March 2002 Resolved
Attatch spanner wrenches to fire stations. (Worklist item)
Due 22 April 2002
Resolved 26 March 2002
Navigation
Issued 29 March 2001 Resolved
PROVIDE UPDATED CHARTS AND PUBLICATIONS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Accommodation/Occupational Safety
Issued 29 March 2001 Resolved
PROVIDE PROPER RAIL COURSES AT THE BOW PULPIT AS REQUIRED BY 46 CFR 177.900_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Electrical
Issued 29 March 2001 Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTS IN ACCOMODATION SPACES AS REQUIRED BY 46 CFR 183.432._x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Electrical
Issued 29 March 2001 Resolved
PROVIDE PROPER WIRING FOR FAN IN CREW BERTHING AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Electrical
Issued 29 March 2001 Resolved
REMOVE DROPLIGHT IN ENGINE ROOM (WIRED TO BATT CHARGER) AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Accommodation/Occupational Safety
Issued 29 March 2001 Resolved
PROVIDE MARKINGS FOR NO PASSENGERS ON UPPER DECKS AS REQUIRED BY 46 CFR 185.602.
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Construction/Loadline
Issued 29 March 2001 Resolved
PROVIDE ATTACHMENTS FOR TWO BAIT TANK HATCHES AFT MAIN DECK AS REQUIRED BY 46 CFR 171.124
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Construction/Loadline
Issued 29 March 2001 Resolved
PROVIDE AUDIBLE ALARMS FOR HIGH WATER BILGE SYSTEM FOR ALL SPACES AS REQUIRED BY 46 CFR 182.530_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Construction/Loadline
Issued 29 March 2001 Resolved
REMOVE OIL AND DEBRIS FROM ENGINE ROOM BILGE AS REQUIRED BY 46 CFR 176.830
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Lifesaving
Issued 29 March 2001 Resolved
PROVIDE FIXED PUBLIC ADDRESS SYSTEM AS REQUIRED BY 46 CFR 184.610_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Engineering
Issued 29 March 2001 Resolved
CORRECT EXCESSIVE LEAKAGE ON PORT SHAFT LOG AS REQUIRED BY 46 CFR 176.802_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 5 April 2001
Resolved 9 April 2001
Electrical
Issued 1 September 2000 Resolved
REPLACE GLASS COVER ON AFT PORT DECK LIGHT AS REQUIRED BY 46 CFR 183.10-20
Condition: Unknown
Due 1 October 2000
Resolved 18 October 2000
Construction/Loadline
Issued 1 September 2000 Resolved
REPLACE RUBBER GASKET ON BOMAR HATCH AS REQUIRED BY 46 CFR 176.802
Condition: Unknown
Due 1 October 2000
Resolved 18 October 2000
Construction/Loadline
Issued 1 September 2000 Resolved
PROPERLY WIRE RUDDER COMPARTMENT FLOAT SWITCH AND MOUNT FLOAT SWITCH AS REQUIRED BY 46 CFR 183. 10-20
Condition: Unknown
Due 1 October 2000
Resolved 18 October 2000
Construction/Loadline
Issued 1 September 2000 Resolved
GRIND AND REWELD EXCESSIVE POROSITY HOLES ON PORT AND STBD SIDE AS MARKED. AS REQUIRED BY ABS WELD REPAIR SECTION 5
Condition: Unknown
Due 1 October 2000
Resolved 18 October 2000
Accommodation/Occupational Safety
Issued 1 September 2000 Resolved
REPAIR CRACK ON PORT HAND RAIL OUTSIDE PILOT HOUSE AS REQUIRED BY 46 CFR 177.35
Condition: Unknown
Due 1 October 2000
Resolved 18 October 2000
Construction/Loadline
Issued 1 September 2000 Resolved
RELABLE ALL VALVES ON BILGE MANIFOLD AS REQUIRED BY 46 CFR 182.25-5
Condition: Unknown
Due 1 October 2000
Resolved 18 October 2000
Electrical
Issued 15 March 2000 Resolved
REWIRE LIGHT IN PASSAGEWAY OUTSIDE AFT ACCOMMODATION SPACE AS REQUIRED BY 46 CFR 183.10-20.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Electrical
Issued 15 March 2000 Resolved
REMOVE DEAD END WIRE IN AFT ACCOMMODATION SPACE CLOSET AS REQUIRED BY 46 CFR 183.10-20.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
REWIRE FRESH WATER PUMP IN LAZARETTE AS REQUIRED BY 46 CFR 183.10-20
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Construction/Loadline
Issued 15 March 2000 Resolved
PROVIDE DRAFT MARKINGS AS REQUIRED BY 46 CFR 185.602
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Accommodation/Occupational Safety
Issued 15 March 2000 Resolved
PROVIDE SUPPORT BRACKETS FOR ENGINE ROOM DECKPLATES AS REQUIRED BY 46 CFR 176.802
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Accommodation/Occupational Safety
Issued 15 March 2000 Resolved
PROVIDE PROPER PIPE PENETRATIONS IN NON-VITAL, NON-METALIC PIPING ON AFT LAZARETTE WATER TIGHT BULKHEAD AS REQUIRED BY 46 CFR 182.720
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Electrical
Issued 15 March 2000 Resolved
PROVIDE GLOBE ON LIGHT AT LADDER LEADING TO ACCOMODATION SPACE AS REQUIRED BY 46 CFR 183.10-20
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Accommodation/Occupational Safety
Issued 15 March 2000 Resolved
REPAIR OR RENEW GALLEY VENT FAN ABOVE STOVE AS REQUIRED BY 46 CFR 183.01-5
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Construction/Loadline
Issued 31 March 1999 Resolved
PROVIDE AND INSTALL A ALARM SWITCH FOR THE LAZARETT.
Condition: Unknown
Due 30 April 1999
Resolved 17 May 1999
Construction/Loadline
Issued 31 March 1999 Resolved
PROVIDE METALIC SHUT OFF VALVES IN THE WATER PIPING SYSTEM IN WAY OF THE BULKHEAD PENETRATIONS LEADING THROUGH THE AFT BULKHEAD OF THE LAZARETT._x001C_ 46CFR 182.720.(d).
Condition: Unknown
Due 30 April 1999
Resolved 17 May 1999
Construction/Loadline
Issued 2 September 1998 Resolved
PROVIDE AND INSTALL METALLIC THROUGH FITTING AND VALVES IN THE PVC LINE PENETRATING WATERTIGHT BULKHEADS. 46 CFR 182.40-1.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Deck/Cargo
Issued 2 September 1998 Resolved
RENEW LEAKING HYDRAULIC FITTING IN FORWARD COMPARTMENT. 46 CFR 176.804.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Documentation
Issued 2 September 1998 Resolved
VESSEL DID NOT HAVE CERTIFICATE OF DOCUMENTATION REFLECTING NEW REGISTERED LENGTH.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Lifesaving
Issued 2 September 1998 Resolved
RENEW BROKEN PADDLE FOR LIFE FLOAT. 46 CFR 180.175(e)(2).
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Accommodation/Occupational Safety
Issued 2 September 1998 Resolved
PROVIDE AND INSTALL 30X30 MESH FLAME SCREEN IN THE MSD VENT LINE. 33 CFR 159.95 (a)(2).
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Accommodation/Occupational Safety
Issued 2 September 1998 Resolved
VESSEL DOES NOT COMPLY WITH REQUIREMENT FOR 36" HANDRAIL HEIGHT ON NEW AFT EXTENSION.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Accommodation/Occupational Safety
Issued 2 September 1998 Resolved
PROVE PROPER OPERATION OF THE 3/4 VOLUME INDICATOR ON THE MSD TANK. 33 CFR159.83.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Navigation
Issued 2 September 1998 Resolved
PROVE PROPER OPERATION OF THE SINGLE SIDE BAND RADIO. 47 CFR 80.903(2).
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Fire Fighting
Issued 28 March 1997 Resolved
THE VESSEL'S UPPER DECK FIRE EXTINGUISHER MOUNT WAS BROKEN DUE TO WASTAGE. REMOUNT FIRE EXTINGUISHER.
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Electrical
Issued 28 March 1997 Resolved
THE VESSEL'S FORWARD ACCOMMODATION'S SPACE EMERGENCY LIGHT WAS INOPERABLE IN ACCORDANCE WITH 46 CFR 183.432.
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Navigation
Issued 28 March 1997 Resolved
VESSEL'S CHARTS AND NAVIGATION PUBLICATIONS WERE MISSING OR OUTDATED. PROVIDE REQUIRED CHARTS AND PUBLICATION IN ACCORDANCE WITH 46 CFR 184.420 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Electrical
Issued 28 March 1997 Resolved
THE GENERATORS DESIGNED FOR 40 DEGREES CELSIUS MAY BE USED IN A 50 DEGREES CELSIUS AMBIENT LOCATION PROVIDED THE MACHINE IS DERATED TO 80 PERCENT OF THE FULL LOAD RATING, AND THE RATING OR SETTING OF THE OVERCURRENT DEVICE IS REDUCED ACCORDINGLY. SEE 46 CFR 183.10-5(f)(2).
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Engineering
Issued 28 March 1997 Resolved
REMOVE PORTABLE PLASTIC GASOLINE CONTAINERS IN ACCORDANCE WITH CERTIFICATE OF INSPECTION PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Engineering
Issued 28 March 1997 Resolved
VESSEL DID NOT HAVE FUEL LINE STOP VALVES AT ENGINES. PROVIDE VALVES IN ACCORDANCE WITH 46 CFR 182.455(b)(4) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Deck/Cargo
Issued 28 March 1997 Resolved
SKIFFS WERE NOT ADEQUATELY SECURED WHEN STOWED. PROVIDE ADEQUATE MEANS OF SECURING SKIFFS PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Lifesaving
Issued 28 March 1997 Resolved
DAY AND NIGHT DISTRESS SIGNALS FOR SKIFFS WERE MISSING. PROVIDE APPROPRIATE SIGNALS IN ACCORDANCE WITH CERTIFICATE OF INSPECTION PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Accommodation/Occupational Safety
Issued 28 March 1997 Resolved
VESSEL'S WASTE RECEPTACLES WERE OF OPEN, PLASTIC TYPE. REMOVE RECEPTACLES AND REPLACE ONLY WITH THOSE IN ACCORDANCE WITH 46 CFR 177.30-7(d) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Lifesaving
Issued 28 March 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Deck/Cargo
Issued 28 March 1997 Resolved
SKIFF BOOM CABLE FRAYED EXCESSIVELY. REPLACE CABLE IN ACCORDANCE WITH _x001C_ 46 CFR 185.704 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Engineering
Issued 28 March 1997 Resolved
PORTABLE GASOLINE CONTAINERS NOT SECURED ADEQUATELY. PROVIDE ADEQUATE STORAGE IN ACCORDANCE WITH CERTIFICATE OF INSPECTION PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 23 July 1997
Resolved 23 July 1997
Documentation
Issued 11 March 1996 Resolved
PROVIDE ONE RADIO OPERATOR WITH MARINE RADIO OPERATORS PERMIT
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Fire Fighting
Issued 11 March 1996 Resolved
CONDUCT MAN OVERBOARD DRILL.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Fire Fighting
Issued 13 April 1994 Resolved
SHAFT GUARD_x001C_
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Engineering
Issued 14 March 1991 Resolved
INSTALL CG APP FUEL FILTERS ON BOTH MDE'S AND BOTH SSG'S
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Electrical
Issued 14 March 1991 Resolved
INSTALL EMERG. LIGHT FOR ESCAPE LADDER LEADING OUT FROM ENGINE ROOM AND AFTACCOM AREA, DEMONSTRATE OPERATION._x001C_
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Electrical
Issued 14 March 1991 Resolved
INSTALL BLANKS IN ENG RM DIST BOX
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Documentation
Issued 31 March 1989 Resolved
PROVIDE ON BOARD AND PROVIDE TO OFFICE IN MOBILE EVIDENCE OF CURRENT VESSELDOCUMENTATION.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Construction/Loadline
Issued 26 March 1987 Resolved
PROVIDE ON BOARD AN ALARM FOR OPERATION OF WATER TIGHT DOOR LOCATED IN FORWARD BERTHING AREA.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 26 March 1987 Resolved
MOUND DOGGING WRENCH AND ADJUST W.T.D.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Documentation
Issued 26 March 1987 Resolved
PROVIDE ON BOARD AT LEAST ONE PERSON HAVING AN FCC OPERATORS PERMIT.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Navigation
Issued 31 March 1986 Resolved
INSTALL COTTER KEYS IN PENS IN STERRING SYESTEM.
Condition: Unknown
Due 31 March 1986
Resolved 31 March 1986
Fire Fighting
Issued 31 March 1986 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 31 March 1986
Resolved 31 March 1986
Documentation
Issued 31 March 1986 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 31 March 1986
Resolved 31 March 1986
Construction/Loadline
Issued 6 November 1984 Resolved
REMOVE AND REPLACE THE TINTED PILOT HOUSE WINDOWS WITH CLEAR WINDOWS SUITABLE FOR USE ON THE VESSEL. THE VESSEL IS PERMITTED TO OPERATE DURING DAYLIGHT HOURS ONLY UNTIL CLEAR WINDOWS ARE INSTALLED.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984

Casualty record · 2

30 July 2009Routine · role: Involved in a Marine Casualty · activity 3568409
30 July 2024Routine · role: Involved in a Marine Casualty · activity 7989398
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.