Records from 1984 to 1999. Most recent: inspection, 15 June 1999.
Inspection history · 36
15 June 1999
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1418549
27 October 1998
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1390857
24 July 1998
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1129321
15 June 1998
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1364769
8 April 1997
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1406089
25 March 1997
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1400527
1 August 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 133531
27 March 1996
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1465860
13 April 1995
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1159183
13 March 1995
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1409249
7 March 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 221013
9 February 1995
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1370993
9 May 1994
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1422369
24 February 1994
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1450827
10 August 1993
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 845811
29 March 1993
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1420715
19 October 1992
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1391791
16 September 1992
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1432621
9 July 1992
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1255075
15 June 1992
Re-Inspection · Drydock Extension
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 955821
26 March 1992
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 946321
27 February 1992
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 954432
12 February 1992
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1268396
7 February 1992
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 63033
29 March 1991
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1220711
30 January 1991
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 928494
10 April 1990
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 917269
23 August 1989
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1206511
2 August 1989
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1201436
12 July 1989
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1041390
13 June 1988
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1200923
27 May 1987
COI Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1339065
18 March 1986
Re-Inspection · Credit Drydock
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 993813
12 August 1985
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1302468
12 April 1985
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1289042
23 April 1984
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 981412
Electrical
Issued 15 June 1998
Resolved
Properly wire bilge pump in accomodation space. Remove wire nuts.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Unknown
Issued 15 June 1998
Resolved
Install metal cable supports in E/R on horizontal cable runs.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Engineering
Issued 15 June 1998
Resolved
Repair main engine fuel solinoid. Engine will not shut off at main console. Repair prior to sailing.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Lifesaving
Issued 15 June 1998
Resolved
Provide light on ring buoy prior to sailing.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Fire Fighting
Issued 15 June 1998
Resolved
Replace extinguisher bracket on port side
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Navigation
Issued 15 June 1998
Resolved
Provide ship's bell prior to sailing
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Navigation
Issued 15 June 1998
Resolved
Repair port and stb running lights prior to sailing
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Unknown
Issued 15 June 1998
Resolved
Provide evidence of drug testing program. Correct prior to sailing
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Lifesaving
Issued 15 June 1998
Resolved
Conduct man overboard drill
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Unknown
Issued 15 June 1998
Resolved
Provide emergency broadcast plaque
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Electrical
Issued 15 June 1998
Resolved
Properly stow batteries in the E/R
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Lifesaving
Issued 15 June 1998
Resolved
Label flare container box
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Engineering
Issued 15 June 1998
Resolved
Clearly mark fuel shut off valve. Old plaque was painted over. Correct prior to sailing.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Unknown
Issued 15 June 1998
Resolved
Provide radio station license, radio telephone cert, operator permit, priorto sailing.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Unknown
Issued 15 June 1998
Resolved
Provide evidence of first aid training
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Lifesaving
Issued 15 June 1998
Resolved
Replace retro reflective tape on PFDs
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Construction/Loadline
Issued 15 June 1998
Resolved
Reinstall bilge pump in accomodation space. Pump mount was broken.
Condition: Unknown
Due 15 June 1998
Resolved 15 June 1998
Construction/Loadline
Issued 13 March 1995
Resolved
Replace three sections of cracked windshield glass in pilothouse.
Condition: Unknown
Due 13 March 1995
Resolved 13 March 1995
Navigation
Issued 15 June 1992
Resolved
REPAIR OR REPLACE MASTHEAD LIGHT AND SHOW PROPER OPERATION.
Condition: Unknown
Due 15 June 1992
Resolved 15 June 1992
Navigation
Issued 15 June 1992
Resolved
PROVIDE ONE (1) SIGNAL BALL DAY SHAPE FOR "VESSEL AT ANCHOR" IN ACCORDANCE WITH NAVIGATION RULE 30.
Condition: Unknown
Due 15 June 1992
Resolved 15 June 1992
Navigation
Issued 15 June 1992
Resolved
REPAIR OR REPLACE ANCHOR LIGHT AND SHOW PROPER OPERATION.
Condition: Unknown
Due 15 June 1992
Resolved 15 June 1992
Accommodation/Occupational Safety
Issued 15 June 1992
Resolved
DEMONSTRATE PROPER OPERATION OF THE TOILET AND THE MARINE SANITATION DEVICETYPE III.
Condition: Unknown
Due 15 June 1992
Resolved 15 June 1992
Lifesaving
Issued 15 June 1992
Resolved
MARK VESSEL NAME ON RING BUOY IN ACCORDANCE WITH 46 CFR 185.30-5.
Condition: Unknown
Due 15 June 1992
Resolved 15 June 1992
Lifesaving
Issued 10 April 1990
Resolved
STENCIL CORRECT LOCATION FOR CHILDS LIFE PRESERVERS
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Electrical
Issued 10 April 1990
Resolved
REMOVE DEAD WIRING IN OVERHEAD OF ENGINEROOM
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Navigation
Issued 2 August 1989
Resolved
REMOUNT MASTHEAD LIGHT 1 METER ABOVE SIDE LIGHTS. COLREGS
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Engineering
Issued 2 August 1989
Resolved
MAKE EMERGENCY FUEL SHUT OFF OPERABLE IAW 46 CFR 182.20-40(B)(3)
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Navigation
Issued 2 August 1989
Resolved
MAKE STEN LIGHT OPERABLE. COLREGS VESSEL IS RESTRICTED TO DAYLIGHT OPERATION UNTIL COMPLETED.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Engineering
Issued 2 August 1989
Resolved
PROVIDE QUICKER MEANS OF ACCESS TO THE FUEL SHUT OFF. 46 CFR 182.20-40(B)(3
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Navigation
Issued 13 June 1988
Resolved
PROVIDE 24 INCH BLACK DAY SHAPE FOR ANCHOR.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Engineering
Issued 13 June 1988
Resolved
PROVIDE 30X30 FLAME SCREENS ON ALL FUEL TANK VENTS.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Construction/Loadline
Issued 13 June 1988
Resolved
PROVIDE PROPER FREEING PORT AREA INWELL DECK AREA IAW 46CFR171.150.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Lifesaving
Issued 13 June 1988
Resolved
PROVIDE 5 ADULT LIFE PRESERVERS.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Electrical
Issued 13 June 1988
Resolved
REMOVE EXCESS UNUSED WIRING IN ENGINE ROOM.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Navigation
Issued 13 June 1988
Resolved
PROVIDE EMERGENCY TILLER
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Fire Fighting
Issued 13 June 1988
Resolved
PROVIDE EMERGENCY HAND HELD FIRE PUMP
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Navigation
Issued 13 June 1988
Resolved
PROVIDE 8 INCH BELL.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Engineering
Issued 13 June 1988
Resolved
PROVIDE FREE ACCESS TO EMERGENCY FUEL SHUT OFF AT FUEL TANK.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Navigation
Issued 27 May 1987
Resolved
TIGHTEN STEERING LINKAGE AS NECESSARY.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Accommodation/Occupational Safety
Issued 27 May 1987
Resolved
BLANK OFF THROUGH HULL FITTING WHERE MARINE SANITATION DEVICE HAS BEEN REMOVED FROM THE VESSEL.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Fire Fighting
Issued 27 May 1987
Resolved
PROVIDE FIRE HOSE NOZZLE MADE OF AN APPROVED MATERIAL.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Fire Fighting
Issued 27 May 1987
Resolved
PROVIDE VALVE HANDLE FOR FIRE HOSE HYDRANT.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Fire Fighting
Issued 27 May 1987
Resolved
PROVE PROPER OPERATION OF FIRE PUMP.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Construction/Loadline
Issued 27 May 1987
Resolved
TIGHTEN ENGINEROOM BILGE THROUGH HULL FITTING ON STARBOARD SIDE.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
PROVIDE 10 ADULT LIFE PRESERVERS.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Engineering
Issued 27 May 1987
Resolved
REATTACH REACH ROD TO EMERGENCY FUEL SHUT OFF VALVE.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Electrical
Issued 27 May 1987
Resolved
REMOVE DEAD END WIRING AND HOUSEHOLD TYPE WIRING AND REPLACE WITH AN APPROVE TYPE CABLE.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Engineering
Issued 27 May 1987
Resolved
REPAIR OR REPLACE AS NECESSARY THE ENGINE TACHOMETER.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Construction/Loadline
Issued 27 May 1987
Resolved
REMOVE WATER FROM BILGES.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
PROVIDE PADDLES AND WATERLIGHT WITH LINE FOR THE LIFEFLOAT AND MARK ALLOWEDCAPACITY IN PERSONS.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
PROVIDE PROPER STOWAGE FOR RING BUOY.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
PROVIDE AN APPROVED WATER LIGHT FOR THE RING BUOY.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Fire Fighting
Issued 27 May 1987
Resolved
PROVIDE TWO B-II PORTABLE FIRE EXTINQUISHERS FOR THE ENGINE ROOM AS REQUIRED BY THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987