MAURY USCG vessel records Sign in
← All vessels

SEA HAWK

SEA HAWK is a 1977 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 1985, most recently in June 1997, along with 25 deficiencies.

Records from 1985 to 1997. Most recent: inspection, 13 June 1997.

Built
1977
Last inspected
13 June 1997
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYC5913
Flag
UNITED STATES
—
Maury page id
psix-53963

Inspections, by type

…with no type recorded4
Years with a record 13 calendar years (1985–1997)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)33.1 ft × 12.0 ft × 5.9 ft
Registered tonnagegross 14 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWELDCRAFT STEEL & MARINE · BELLINGHAM WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portVALDEZ, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
9 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 31

13 June 1997 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 775563
6 May 1996 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1077697
22 May 1995 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 873530
9 May 1994 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1169443
13 July 1993 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 140981
4 June 1993 Drydock Extension · Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 841584
18 June 1992 Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 960347
18 June 1992 Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 960351
10 February 1992 Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 961489
2 August 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 915173
17 July 1991 Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 937005
12 June 1991 Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 904429
7 June 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 914334
19 April 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1224756
24 January 1991 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 911682
9 October 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 905465
4 September 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1236161
20 June 1990 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 928603
8 June 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1225579
7 September 1989 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 895469
29 June 1989 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1207367
7 June 1989 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 886768
21 July 1988 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1036616
7 June 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 888566
14 December 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1314317
23 November 1987 Hull Examination · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1334687
13 November 1987 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1332305
26 August 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1030850
3 July 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1304578
3 April 1986 Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1309225
16 July 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 989182

Deficiency record · 25

Engineering
Issued 6 May 1996 Resolved
PROVE PROPER OPERATION OF MAIN DIESEL ENGINES IN AHEAD AND ASTERN MODES.
Condition: Unknown
Due 6 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 May 1996 Resolved
PROVIDE AND INSTALL DOUBLE HOSE CLAMPS ON FOLLOWING SEA VALVES: STBD SEA SUCTION FOR MAIN ENGINE COOLING WATER AND 1 INCH GATE VALVE FOR SEA SUCTIONTO WASH DOWN PUMP.
Condition: Unknown
Due 6 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 6 May 1996 Resolved
PROVIDE RETROREFLECTIVE TAPE FOR BUOYANT APPARATUS AND MOUNT ON SAME ITEM IN ACCORDANCE WITH NVIC 1-87.
Condition: Unknown
Due 6 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 6 May 1996 Resolved
PROVIDE RETROREFLECTIVE TAPE ON LIFE RING AND AFFIX THE TAPE TO THE LIFE RING IN ACCORDANCE WITH NVIC 1-87.
Condition: Unknown
Due 6 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 12 June 1991 Resolved
CONDUCT STABILITY TEST USING 36 INCH RAIL HEIGHT ON WEATHER DECK FORWARD OFCABIN. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Accommodation/Occupational Safety
Issued 12 June 1991 Resolved
PROVIDE 36 INCH RAILS ON WEATHER DECK FORWARD OF CABIN. PROVIDE EVENLY SPACED RAIL COURSES BELOW TOP RAIL IN THIS AREA AND DOWN SIDES OF VESSEL FORWARD OF COCKPIT._x001C_ _x001C_
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Fire Fighting
Issued 8 June 1990 Resolved
SERVICE OR REMOVE SPARE B-I PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Documentation
Issued 8 June 1990 Resolved
PROVIDE COPY OF STABILITY LETTER.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Accommodation/Occupational Safety
Issued 8 June 1990 Resolved
SECURE LADDER TO FLYING BRIDGE.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Construction/Loadline
Issued 8 June 1990 Resolved
PROVIDE CAP ON THRU HULL FITTING IN STARBOARD SIDE OF TRANSOM.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Engineering
Issued 8 June 1990 Resolved
REPLACE FLEXIBLE FUEL SUPPLY AND FUEL RETURN LINES ON PORT AND STARBOARD MAIN ENGINES WITH ACCEPTABLE MARINE TYPE WIRE REINFORCED FLEXIBLE FUEL LINES.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Lifesaving
Issued 29 June 1989 Resolved
RE-NEW FLOAT LINE ON RING BUOY.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 29 June 1989 Resolved
SUPPLY ENCLOSURE FOR REQUIRED HAND FLARES.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Fire Fighting
Issued 29 June 1989 Resolved
SERVICE HAND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Documentation
Issued 7 June 1988 Resolved
PRIOR TO CARRIAGE OF MORE THAN 6 PASSENGERS, PROVIDE A COPY OF A VALID FCC CERTIFICATE TO THIS OFFICE TO THE STAISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Accommodation/Occupational Safety
Issued 7 June 1988 Resolved
LABEL AND WIRE SHUT OVERBOARD DISCHARGE VALVE FOR MSD. LABEL TO READ "KEEP VALVE SHUT IN U.S. WATERS". TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Lifesaving
Issued 7 June 1988 Resolved
MAKE MINOR REPAIRS TO LIFE FLOAT SKIN TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Fire Fighting
Issued 7 June 1988 Resolved
SERVICE OR REMOVE SPARE, OUT OF DATE, B-I FIRE EXTINGUISHER TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Engineering
Issued 7 June 1988 Resolved
INSTALL FLAME SCREEN ON STARBOARD FUEL TANK VENT TO THE SATISFACTION OF THECOGNIZANT OCMI.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Engineering
Issued 26 August 1987 Resolved
PROVIDE PROPER METAL CUPS UNDER RACOR FUEL FILTERS.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Lifesaving
Issued 26 August 1987 Resolved
PLACE VESSEL'S NAME ON RING BUOY AS REQUIRED BY 46CFR 185.30-5(C).
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Fire Fighting
Issued 26 August 1987 Resolved
PROVIDE A PORTABLE FIRE PUMP.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Engineering
Issued 26 August 1987 Resolved
GET REMOTE FUEL OIL SHUTDOWN VALVES TO OPERATE.
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Lifesaving
Issued 26 August 1987 Resolved
RENEW ALL OUTDATED DISTRESS SIGNALS (FLARES).
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987
Electrical
Issued 26 August 1987 Resolved
PROVIDE SUITABLE MATERIAL THAT RESISTS DETERIORATION BY ACTION OF ELECTROLYTE UNDER BATTERIES (46CFR 183.05-20(D)).
Condition: Unknown
Due 26 August 1987
Resolved 26 August 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.