MAURY USCG vessel records Sign in
← All vessels

CLIFFS MARQUETTE

CLIFFS MARQUETTE is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 49 inspections since 1982, most recently in January 1996, along with 167 deficiencies.

Records from 1982 to 1996. Most recent: inspection, 16 January 1996.

Built
1982
Last inspected
16 January 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WRB 3155
Flag
UNITED STATES
—
Maury page id
psix-53974

Inspections, by type

…with no type recorded15
Years with a record 15 calendar years (1982–1996)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3678 - Regulatory (Subpart C or D), Gross Ton
3678 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 49

16 January 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1182474
27 October 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 877493
26 September 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1188241
24 July 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 880889
19 June 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1188090
27 April 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427048
6 March 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1167372
6 December 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1138354
18 November 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1179449
21 October 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1461613
18 August 1994 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458185
21 March 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1165609
17 February 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 853036
7 January 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 851515
18 October 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465764
22 April 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1143551
30 January 1993 Deficiency Check · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1354305
20 December 1992 Examination of Repairs · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1140174
25 October 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1471080
16 August 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 951325
13 May 1992 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 947801
7 March 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 946813
14 November 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1259364
19 October 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944144
29 April 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1306976
13 February 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219205
5 December 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215086
27 September 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1217123
12 January 1990 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 902584
6 September 1989 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936657
6 September 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1034280
22 June 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035052
6 January 1989 Deficiency Check · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195019
5 November 1988 Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 894101
10 December 1987 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1004331
30 April 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1017694
3 February 1987 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1314756
10 November 1986 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1015388
5 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 979485
5 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1298765
12 September 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 974325
29 August 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1282244
17 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973956
11 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281708
23 March 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281353
15 March 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280010
30 December 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278513
23 August 1982 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 964834
23 August 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969669

Deficiency record · 167

Construction/Loadline
Issued 19 June 1995 Resolved
MAKE REPAIRS TO FRACTURES AT LEG-TO-CHORD CONNECTIONS AS PROPOSED IN CLIFFSDRILLING LETTER DATED 25MAY95.
Condition: Unknown
Due 30 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 27 April 1995 Resolved
Submit proposal for repairs to [name withheld] for the repairs to chord and spud can connections. Proposal to include copy of ABS reccomendations,NDE report, video film of NDE, operational schedule, and any other pertinent data that may influence the OCMI's decision.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Lifesaving
Issued 21 October 1994 Resolved
PROVE PROPER OPERATION OF #3 S/S GENERATOR OVERSPEED TRIP ALARM.
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Construction/Loadline
Issued 18 August 1994 Resolved
Renew 6" check valves in overboard drain lines located in #9 P/S drill water tanks.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Unknown
Issued 18 August 1994 Resolved
Make permanant repairs to raw water line in #9 port drill water tank. (Currently there are three soft patches on pipe).
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Construction/Loadline
Issued 18 August 1994 Resolved
Renew all missing or damaged bolts/studs on all tank/void hatch covers and secure same.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Construction/Loadline
Issued 18 August 1994 Resolved
Complete underwater portion (Leg/Can connection) of SEILODD.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Construction/Loadline
Issued 18 August 1994 Resolved
Make available for CG inspection the mud pit thru-hull dump valve and the sea water sea chect valve.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Electrical
Issued 18 October 1993 Resolved
RENEW BATTERIES FOR EMERGENCY GENERATOR STARTING/CONTROL SYSTEMS.
Condition: Unknown
Due 18 October 1993
Resolved 18 October 1993
Electrical
Issued 18 October 1993 Resolved
PROVE PROPER OPERATION OF ABT FOR AUTO START AND OVERSPEED TRIP FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 18 October 1993
Resolved 18 October 1993
Engineering
Issued 18 October 1993 Resolved
RENEW FUELING HOSE.
Condition: Unknown
Due 7 January 1994
Resolved 7 January 1994
Engineering
Issued 25 October 1992 Resolved
REPLACE FLEX-SPOOL PIECES FROM WATER TOWER TO RAW WATER PIPING.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992 Resolved
MAKE REPAIRS TO #1 (STBD) LIFEBOAT DIESEL ENGINE AND PROVE PROPER OPERATIONOF SPRINKLER SYSTEM. THIS IS TO BE WITNESSED BY THE MASTER, LOGGED IN OFFICIAL LOG BOOK, AND A COPY TO BE PROVIDED TO THIS OFFICE. UNTIL THIS ISCLEARED, VSL MUST MAINTAN A STANDBY BOAT OR PROVIDE THROWOVER INFL RAFTS.
Condition: Unknown
Due 25 November 1992
Resolved 10 November 1992
Fire Fighting
Issued 25 October 1992 Resolved
PROVIDE PROPER OPERATION OF MUD PIT ROOM LOSS OF VENTILATION.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992 Resolved
PROVE PROPER OPERATION OF AUTOMATIC BUS TIE (ABT) ON EMERGENCY GENERATOR.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992 Resolved
PROVIDE PLACARD OR STENCIL GENERAL ALARM ON STBD JACK HOUSE TO READ "GENERAL ALARM, WHEN THIS BELL RINGS GO TO YOUR STATION". IN ENGLISH AND INSPANISH.
Condition: Unknown
Due 25 November 1992
Resolved 10 November 1992
Documentation
Issued 25 October 1992 Resolved
PROVIDE ONBOARD PERSONNEL TO MEET REQUIRED MANNING AS SHOWN ON CERTIFICATE OF INSPECTION; (2 ABs, 1 ORDINARY, 1 OFFSHORE INSTALLATION MANAGER, WHICH MUST INCLUDE 4 LIFEBOATMEN.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992 Resolved
INSTALL LADDER PROTECTIVE CAGING ON PORT JACKHOUSE.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992 Resolved
RENEW AIR PURGE WARNING INDICATORS ON MUD VOLUME TOTALIZER AND INSTALL INDICATOR ON GAS DETECTION BOX.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992 Resolved
REPLACE MISSING NITROGEN CYLINDERS ON BOTH HELO DECK B-V SYSTEMS. UNTIL THIS ITEM IS COMPLETE, NO HELO OPERATIONS MAY BE CONDUCTED.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992 Resolved
PROVIDE PERMANENT STENCIL OR PLACARD FOR GENERAL ALARM CONTACT MAKER AND GENERATOR SHUTDOWN ON DRILL FLOOR.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992 Resolved
INSTALL PROPERLY RATED RELIEF VALVES (NOT OVER 100 PSI AND 210F) FOR WATER HEATERS.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992 Resolved
PROVIDE ADEQUATE MEANS OF CLOSURE FOR DOOR OF PAINT LOCKER FOR FIXED FIRE- FIGHTING SYSTEM. (PROVIDE NEW DOOR FOR PAINT LOCKER)
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #2: TWO (2) BC1 FIRE EXTINGUISHERS; RENEW AIR CYLINDER HOSE (LOWER CYL); ONE (1) JACKNIFE; RENEW ALL HATCH GASKETS; HYDRO ALL AIR CYLINDERS; TWELVE (12) HAND-HELD FLARES; MAKE PERMANENT REPAIRS TO DIESEL EXHAUST.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992 Resolved
REMOVE OR LOCK HOSE CRIMPER UNIT, LOCATED UNDER DRILL PIPE RACK. IF LOCKED, STENCIL "USE REQUIRES HOT WORK PERMIT".
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Construction/Loadline
Issued 25 October 1992 Resolved
REPAIR DOOR AND SILL TO MAKE WEATHER TIGHT INTO CONTROL ROOM.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992 Resolved
PROVIDE FOLLOWING FOR FIREMAN'S OUTFIT ON CONTROL DECK: LIFELINE (46CFR96.35); FIRE SUIT PANTS AND EXPLOSIVE METER/O2 METER. AND SAME FOR FIREMAN'S OUTFIT IN MCHINERY SPACE.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Navigation
Issued 25 October 1992 Resolved
MAKE OPERATIONAL AND FOCUS PORT OBSTRUCTION LIGHT.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Engineering
Issued 25 October 1992 Resolved
REPAIR COOLING WATER LEAK ON #4 GENERATOR DIESEL ENGINE. PROVIDE DOCUMENTATION FROM CATERPILLAR MECHANICS SHOWING OVERSPEED, LOW LUBE OIL, AND HIGH WATER TEMPERATURE ALARMS/SHUTDOWNS ARE OPERATING PROPERLY AFTER OVERHAUL/MAINTENANCE.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Construction/Loadline
Issued 25 October 1992 Resolved
PAINT VESSEL NAME ON HELO DECK IAW 46 CFR 108.241.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Documentation
Issued 25 October 1992 Resolved
PROVIDE COPY OF CURRENT (VALID) LOADLINE CERTIFICATE.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Documentation
Issued 25 October 1992 Resolved
SUBMIT HAZARDOUS LOCATION PLAN TO MARINE SAFETY OFFICE NEW ORLEANS FOR APPROVAL.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992 Resolved
PROVIDE BODY STRAPS AND HOISTING SLING FOR STOKES LITTER.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #1: TWO (2) BC1 FIRE EXTINGUISHERS; ONE (1) HATCHET; ONE (1) JACKNIFE; RENEW GASKETS ON ALL HATCHES; HYDRO TEST ALL AIR BOTTLES; TWELVE (12) HAND-HELD FLARES; MAKE PERMANENT REPAIRS TO DIESEL EXHAUST.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992 Resolved
REPAIR HOLE IN BOTTOM OF BATTERY BOX ON BULKHEAD ADJACENT TO LIFEBOAT #1.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Construction/Loadline
Issued 16 August 1992 Resolved
MAKE MUD DUMP VALVE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 16 August 1992
Resolved 16 August 1992
Construction/Loadline
Issued 13 May 1992 Resolved
PROVIDE GAUGING AND UT REPORTS COONDUCTED 13MAY92
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Construction/Loadline
Issued 13 May 1992 Resolved
MAKE AVAILABLE FOR INSPECTION THE SEA CHEST VALVE AND MUD DUMP VALVE.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Construction/Loadline
Issued 13 May 1992 Resolved
PROVIDE REPAIR PROPOSAL AND MAKE PERMANENT REPAIRS TO PORT LEG ("B" AND "C"CORDS).
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Construction/Loadline
Issued 13 May 1992 Resolved
CLEAN OR REPLACE WTD GASKETS THROUGHOUT VESSEL.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Construction/Loadline
Issued 13 May 1992 Resolved
MAKE SPUD CANS AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Engineering
Issued 19 October 1991 Resolved
PROVIDE HEAT RESISTANT SIGHT GLASS FOR THE GENERATOR ROOM DAY TANK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Electrical
Issued 19 October 1991 Resolved
PROVE PROPER OPERATION OF THE LOSS OF VENTILATION ALARM FOR THE MUDPITS ANDREMOTE VENTILATION SHUTDOWN FOR THE ENGINEROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991 Resolved
PROVIDE PROPER SUPPORT FOR FIREMAIN AT INTERNATIONAL SHORE CONNECTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Accommodation/Occupational Safety
Issued 19 October 1991 Resolved
PROVE PROPER OPERATION OF THE MANUAL ENGINE ROOM VENTILATION CLOSURES AND REPAIR OR REPLACE WASTED VENT TRUNK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991 Resolved
PROVIDE COMPLETE PORTABLE FIRE EXTINGUISHER SERVICING REPORT TO THE COAST GUARD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1991
Resolved 30 October 1991
Documentation
Issued 19 October 1991 Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED CONSTRUCTION PORTFOLIO WITH THE APPROVAL LETTER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991 Resolved
REPAIR/REPLACE WASTED HELO DECK NETTING SUPPORT STBD SIDE AFT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Electrical
Issued 19 October 1991 Resolved
PROVIDE BATTERY BOX FOR THE RADIO BATTERY LOCATED 03 DECK PORTSIDE OF THE PILOTHOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991 Resolved
SERVICE DRY CHEMICAL WHEEL UNITS LOCATED ON HELO DECK. RUST BUILT UP ON DRYCHEMICAL STORAGE CYLINDER BETWEEN N2 AND DRY CHEMICAL CYLINDERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991 Resolved
PROVIDE SAFETY CHAINS ON AFT CENTER OF PIPE DECK AND AT AFT PORT CATWALK ONPIPE DECK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Electrical
Issued 19 October 1991 Resolved
REMOVE NON-APPROVED ELECTRICAL CABLE (YELLOW) LOCATED MAIN DECK IN VACINITYOF FIRE STATION NO. 13 OR PROVIDE SERVICE/USAGE STATEMENT INCLUDING THE VOLTAGE._x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Accommodation/Occupational Safety
Issued 19 October 1991 Resolved
PROVIDE ASME APPROVED RELIEF VALVES ON FOLLOWING PRESSURE VESSELS: COLD START AIR, RIG FLOOR AIR, BOTH SHIP SERVICE AIR, AND BULK AIR DRYER. PROVIDE RELIEF VALVE ON HOT WATER HEATER 100 PSI/210 DEGREES F. OR OPEN FORINTERNAL INSPECTION. PROVIDE RELIEF OF 100 PSI OR LESS ON POT. WATER TANK._x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991 Resolved
INSTALL FLOAT SMOKE SIGNALS AT QUICK RELEASE RING BOUY STATIONS (BOTH MISSING)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Deck/Cargo
Issued 19 October 1991 Resolved
PORT AND STBD CRANES- PROVIDE PROPER FUEL HOSE WITH AUTO SHUTOFF NOZZLES. REPLACE BROKEN CAB GLASS IN STBD CRANE. PROVIDE PROPER FUEL HOSE WITH AUTO SHUTOFF NOZZLE ON LOGGING UNIT. PROVIDE SELF MOUSING HOOKS FOR BOTH CRANES. _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991 Resolved
PROVIDE ON BOARD AUXILIARY LINE FOR IMPULSE PROJECTED LINE THROWING APPLIANCE OF AT LEAST 1500 FEET IN LENGTH (MANILA OF 3" OR MORE IN CIRCUMFERENCE OR SYNTHETIC HAVING A BREAKING STRENGTH OF AT LEAST 9,000 POUNDS AND ULTRA VIOLET RESISTANT)._x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991 Resolved
REPAIR ALL LEAKING NAVY ALL PURPOSE NOZZLES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991 Resolved
TEST FIRE THE ROCKET TYPE LINE THROWING APPLIANCE PER 46CFR109.207 & 433, TEST LIFEBOAT RADIO WEEKLY PER 46CFR109.217 & 431, INSPECT LIFEBOAT WINCH CONTROLLER QUARTERLY PER 46CFR109.221, AND TEST GENERAL ALARMS AND WHISTLE PER 46CFR109.201._x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991 Resolved
CORRECT HALON SYSTEM INSTALLATION FOR GENERATOR ROOM PER SOTEC'S SERVICING REPORT OR SUBMIT APPROVED PLANS REFLECTING THE INSTALLATION FOR REVIEW TO THE COAST GUARD.(REF. FIXED EXTINGUISHING NVIC)_x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991 Resolved
PROVIDE COAST GUARD APPROVED EMBARKATION LADDERS (JACOBS TYPE) PORT AND STBD LIFEBOAT DECKS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Documentation
Issued 19 October 1991 Resolved
PROVIDE EVIDENCE THAT THE LAST LOADLINE SURVEYS WERE COMPLETED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Electrical
Issued 19 October 1991 Resolved
MAKE EMERGENCY GENERATOR OPERATIONAL AND PROVE PROPER OPERATION OF OVERSPEED SHUTDOWN AND LOW L/O ALARM AND HIGH WATER JACKET TEMPERATURE ALARM._x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Deck/Cargo
Issued 19 October 1991 Resolved
PROVIDE DESIGNATED CRANE OPERATORS IN WRITING AND COMPLETE DAILY CHECK REQUIREMENTS PER API RP-2D._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991 Resolved
PROVIDE A MORE SECURE AND STURDY RAMP AT LIFEBOAT EMBARKATION STATIONS AND PROVIDE MEANS FOR PERMANENT OR REMOVEABLE CHAINS/RAILINGS ON EACH SIDE OF RAMPS._x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Documentation
Issued 5 December 1990 Resolved
PROVIDE PROOF OF CERTIFICATE OF DOCUMENTATION UPGRADE TO "REGISTRY."_x001C_ MAKE REPAIRS PRIOR TO 05JAN91._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990 Resolved
RELOCATE INTERNATIONAL SHORE CONNECTION TO ALLOW CLOSURE OF EMERGENCY GENERATOR SPACE VENT CLOSURE LOCATED ON PORT AFT OF HOUSE STRUCTURE. MAKE REPAIRS PRIOR TO 05JAN91.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990 Resolved
REPLACE TWO MISSING GLASS COVERS TO FIXED FIRE FIGHTING RELEASE PULLS LOCATED OUTSIDE OF EMERGENCY GENERATOR ROOM. MAKE REPAIRS PRIOR TO 05JAN91.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 5 December 1990 Resolved
PROVIDE ONBOARD AN IMPULSE PROJECTED ROCKET TYPE LINE THROWING APPLIANCE INACCORDANCE WITH 46 CFR 108.517. MAKE REPAIRS PRIOR TO 05JAN91._x001C_
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 5 December 1990 Resolved
PROVIDE ON BOARD A PORTABLE REDIO APPARATUS IN ACCORDANCE WITH 46 CFR 108.519. MAKE REPAIRS PRIOR TO 05JAN91.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Electrical
Issued 5 December 1990 Resolved
PROVIDE PROPER WIRE FOR PHONE BOX IN SHALE SHAKER AREA. MAKE REPAIRS PRIORTO 05JAN91.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Electrical
Issued 5 December 1990 Resolved
PROVIDE PURGE ALARM FOR EMERGENCY DRAWWORKS CONTROL PANEL LOCATED AFT OF DRILLER'S CONSOLE ON RIG FLOOR. MAKE REPAIRS PRIOR TO DRILLING OPERATIONS OR 05JAN91.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990 Resolved
MAKE REPAIRS TO MANUAL VENT CLOSURE FOR MAIN GENERATOR SPACE. SEVERAL CLOSURAL BLADES WERE INOPERATIVE. MAKE REPAIRS PRIOR TO 05JAN91.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Engineering
Issued 5 November 1988 Resolved
INSTALL REMOTE REACH RODS FOR FUEL SYSTEM SUPPLY TO SHUT DOWN THE MACHINERYAND MUST BE OPERABLE FROM OUTSIDE THE MACHINERY SPACE. THIS ALSO APPLIES TO THE EMERGENCY GENERATOR
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Fire Fighting
Issued 5 November 1988 Resolved
PROVIDE ONE (1) OXYGEN/EXPLOSIVE METER FOR FIREMAN'S OUTFIT.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Fire Fighting
Issued 5 November 1988 Resolved
REPAIR/RENEW BELL ALARM FOR ENGINE ROOM SELF-CONTAINED BREATHING APPARATUS (PART OF FIREMAN'S OUTFIT).
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Lifesaving
Issued 5 November 1988 Resolved
REPAIR OR RENEW FORWARD UPPER SHEAVE BUSHING/BEARING ON PORT LIFEBOAT DAVITAND AFT MIDDLE SHEAVE BUSHING/BEARING JUST ABOVE CONTROLLER ON STARBOARD LIFEBOAT DAVIT.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Accommodation/Occupational Safety
Issued 5 November 1988 Resolved
REPAIR VENTILATION FLOW PROBLEM IN MUD PITS SO THAT AIR FLOWS INTO MUD PITS COMPARTMENT FROM ADJACENT SPACES. IF VENTILATION LOSS ALARMS CHANGED AS PART OF THE SOLUTION, DEMONSTRATE SATISFACTORY OPERATION.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Deck/Cargo
Issued 5 November 1988 Resolved
PROVIDE API HAND SIGNAL CHARTS FOR BOTH CRANES.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Electrical
Issued 5 November 1988 Resolved
MAKE EMERGENCY LIGHTING FOR BOTH LIFEBOATS DIRECTABLE.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Documentation
Issued 5 November 1988 Resolved
INCLUDE ALL REQUIRED LOG ENTRIES IN VESSEL LOG. SUBMIT A COPY SHOWING THE DATE OF THE LAST LIFEBOAT FUEL CHANGES, DATE LIFEBOATS WERE OPERATED IN THEWATER, DATE WINCHES WERE INSPECTED AND THE DATE THE FALLS WERE RENEWED.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Documentation
Issued 5 November 1988 Resolved
REVISE, TO INCLUDE ALL INFORMATION IN 46 CRF 109.121, IN THE OPERATIONS MANUAL. SUBMIT OPERATIONS MANUAL AND CONSTRUCTION PORTFOLIO TO COMMANDING OFFICER, MARINE SAFETY OFFICE FOR APPROVAL.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Documentation
Issued 5 November 1988 Resolved
REPAIR/RENEW PILOT WINDOWS IN BOTH LIFEBOATS.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Lifesaving
Issued 5 November 1988 Resolved
PROVIDE CABLE DATA FOR THE LIFEBOAT FALLS.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Lifesaving
Issued 5 November 1988 Resolved
DEMONSTRATE WATERSPRAY SYSTEM FOR BOTH LIFEBOATS.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Lifesaving
Issued 5 November 1988 Resolved
PROVIDE TWELVE (12) HAND HELD ROCKET PROPELLED PARACHUTE FLARES.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Documentation
Issued 5 November 1988 Resolved
SUBMIT A DRYDOCKING PROPOSAL.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Lifesaving
Issued 5 November 1988 Resolved
CONDUCT SATISFACTORY FIRE AND BOAT DRILL IN PRESENCE OF USCG MARINE INSPECTOR. DRILL TO INCLUDE EXAMINATION OF GENERAL ALARM SYSTEM.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Fire Fighting
Issued 5 November 1988 Resolved
EVALUATE FIRE MAIN PRESSURE TO DETERMINE IF A RELIEF VALVE IS REQUIRED, IN ACCORDANCE WITH 46 CFR 108.417(A), AT EACH FIRE PUMP. SUBMIT RESULTS TO MSO MORGAN CITY.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Fire Fighting
Issued 5 November 1988 Resolved
REPAIR PIPING TO HYDRANTS NO. 6 AND NO. 10. CONDUCT A HYDROSTATIC TEST AT 1.5 WORKING PRESSURE FOR THE REPAIRED PIPING IN THE PRESENCE OF A USCG INSPECTOR.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Electrical
Issued 5 November 1988 Resolved
DEMONSTRATE THAT THREE (3) LIGHTS UNDER DRILL FLOOR MEET REQUIREMENTS FOR CLASS I DIVISION I LOCATION OR THEY MUST BE REPLACED OR REMOVED.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Fire Fighting
Issued 5 November 1988 Resolved
MAKE REPAIRS TO THE NO. 2 FIRE PUMP TO PROVIDE SUFFICIENT PRESSURE.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Electrical
Issued 5 November 1988 Resolved
DEMONSTRATE OVERSPEED OPERATION, LOW LUBE OIL SHUTDOWN, AND LOW LUBE OIL AND HIGH TEMPERATURE ALARMS FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Electrical
Issued 5 November 1988 Resolved
REPAIR THE TACHOMETER ON NO. 4 CAT GENERATOR SET
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Fire Fighting
Issued 5 November 1988 Resolved
POST OPERATING INSTRUCTIONS FOR THE HALON SYSTEM CONTROLS OUTSIDE EMERGENCYGENERATOR SPACE ON THE MAIN DECK.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Electrical
Issued 5 November 1988 Resolved
PROVIDE DATA ON CABLE TYPE USED FOR MUD PIT LEVEL INDICATORS (MUST BE EITHER EXANE OR POLYRAD XT TYPE).
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Electrical
Issued 5 November 1988 Resolved
RENEW BATTERIES FOR EMERGENCY LIGHTS IN THE HALLIBURTON ROOM, LADDER LEADING BELOW NEAR STARBOARD CRANE, SCR ROOM, SACK ROOM, AND MUD PUMP ROOM.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Accommodation/Occupational Safety
Issued 5 November 1988 Resolved
PROVIDE RAILS FOR THE GENERATOR CATWALKS AND STAIRS.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Electrical
Issued 5 November 1988 Resolved
DEMONSTRATE THAT GOVERNORS' SETTING FOR D399 CAT GENERATOR SETS ARE BELOW THAT OF THE OVERSPEED DEVICES.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Electrical
Issued 5 November 1988 Resolved
PROVIDE ELECTRICAL INSULATION MAT FOR THE EMERGENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Electrical
Issued 5 November 1988 Resolved
DEMONSTRATE BATTERIES INSTALLED FOR GENERAL ALARM ARE SUFFICIENT TO COMPLY WITH 46 CFR 113.25-6.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Electrical
Issued 5 November 1988 Resolved
PROVIDE DOCUMENTATION ON THE LIGHTING PANEL ON THE PORT SIDE OF THE DRILL FLOOR SHOWING UL, FM, OR CSA APPROVAL.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Engineering
Issued 5 November 1988 Resolved
PROVIDE STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Construction/Loadline
Issued 5 November 1988 Resolved
INSTALL OR RELOCATE ONE OF THE TWO BILGE PUMPS IN ANOTHER SPACE WATERTIGHT FROM THE MACHINERY SPACE. DRAWINGS FOR CHANGE TO BE SUBMITTED TO MSO MORGAN CITY, LA.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Lifesaving
Issued 10 December 1987 Resolved
PROVIDE 12 HAND HELD FLARES FOR EACH SURVIVAL CAPSULE WITH CURRENT DATES
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Lifesaving
Issued 10 December 1987 Resolved
PROVIDE 1 SERVICE PROJECTILE FOR LINE THROWING GUN
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Documentation
Issued 10 December 1987 Resolved
PROVIDE CURRENT DOCUMENT STICKER FOR MARINE DOCUMENT
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Electrical
Issued 10 November 1986 Resolved
CONNECT THE "IN WATER" SPOTLIGHT FOR THE NUMBER 2 LIFEBOAT TO THE EMERGENCYLIGHTING CIRCUIT.
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 10 November 1986 Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED DIAGONAL/HORIZONTAL TRUSS CONNECTIONSAT THE 45 FOOT LEVEL ON THE PORT LEG RACKLESS CHORD.
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 10 November 1986 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION THE RIG BARGE TANKS AND VOIDS, INCLUDING ALL SEA VALVES, UPON THE NEXT RIG MOVE.
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Fire Fighting
Issued 10 November 1986 Resolved
PROVIDE FOR THE SERVICING AND TESTING OF THE PAINT LOCKER CO2 FIXED FIRE EXTINGUISHING SYSTEM INCLUDING POSTING OF CORRECT OPERATING INSTRUCTIONS AND RENEWAL OF WINDOW AND EXHAUST FAN LOUVER DAMPERS.
Condition: Unknown
Due 10 November 1986
Resolved 10 November 1986
Construction/Loadline
Issued 5 April 1985 Resolved
COMPLETE THE UNDERWATER EXAMINATION IN LIEU OF DRYDOCKING UPON THE NEXT RIGMOVE AND PRIOR TO COMMENCEMENT OF DRILLING OPERATIONS.
Condition: Unknown
Due 5 April 1985
Resolved 5 April 1985
Fire Fighting
Issued 5 April 1985 Resolved
SUBMIT A PROPOSAL FOR GENERAL ALARM SIGNAL INSTALLATION INCLUDING EQUIPMENTSPECIFICATIONS FOR THE SHELL SHAKER AREA TO THE COGNIZANT OFFICER IN CHARGE, MARINE INSPECTION.
Condition: Unknown
Due 5 April 1985
Resolved 5 April 1985
Unknown
Issued 5 April 1985 Resolved
COMPLETE THE UNDERWATER EXAMINATION IN LIEU OF DRYDOCKING UPON THE NEXT RIGMOVE.
Condition: Unknown
Due 5 April 1985
Resolved 5 April 1985
Construction/Loadline
Issued 29 August 1984 Resolved
REPLACE VALVE CONTROL WHEEL TO #1 VOID TANK VALVE STEM IN ENGINE ROOM W/I THIRTY (30) DAYS.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Fire Fighting
Issued 29 August 1984 Resolved
PROCURE ONE (1) LIFELINE AS REQUIRED BY REGULATIONS FOR EACH FIREMANS OUT- FIT (2 TOTAL) AND PLACE ON BOARD RIG W/I 7 DAYS.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Navigation
Issued 29 August 1984 Resolved
PROCURE REQUIRED DAY SHAPES(B-D-B) W/I THIRTY (30) DAYS BUT NO LATER THAN NEXT RIG MOVE.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Lifesaving
Issued 29 August 1984 Resolved
EQUIP SEVEN (7) LIFE JACKETS WITH LIGHTS, WHISTLES OR BOTH W/I 24 HOURS.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Lifesaving
Issued 29 August 1984 Resolved
PROVIDE AUXILIARY LINE (500") FOR LINE THROWING GUN W/I 7 DAYS.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Fire Fighting
Issued 29 August 1984 Resolved
REPAIR OR REPLACE PRESS EQUALIZER LINE ON HALON CYLINDERS PROTECTING GENERATOR ROOM W/I 7 DAYS.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Fire Fighting
Issued 29 August 1984 Resolved
PROVIDE EVIDENCE OF ANNUAL SERVICING OF FIRE FIGHTING EQUIPMENT W/I 7 DAYS.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Unknown
Issued 29 August 1984 Resolved
CONDUCT INTERNAL EXAM OR HYDROSTATICALLY TEST DRILL FLOOR A/R AT NEXT DRY- DOCK. BUT NO LATER THAN 23FEB85.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Unknown
Issued 29 August 1984 Resolved
MAKE #1 AND #2 BULK CEMENT TANKS AVAILABLE FOR INTERNAL INSPECITON AT NEXT DRYDOCK. BUT NOT LATER THAN 23FEB85.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Electrical
Issued 29 August 1984 Resolved
REPAIR "EXIT" LIGHT ON STARBOARD STAIRWAY OFF PUMP ROOM W/I 24 HOURS.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Lifesaving
Issued 29 August 1984 Resolved
PROVIDE LANTHERN AND OIL FOR EACH LIFEBOAT AND PLACE ABOARD W/I 7 DAYS.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Lifesaving
Issued 29 August 1984 Resolved
PROCURE TEN (10) HAND HELD FLARES FOR LIFEBOATDS W/I 7 DAYS AND PLACE ABOARD.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Unknown
Issued 29 August 1984 Resolved
SUBMIT A PROPOSAL FOR GENERAL ALARM SIGNAL INSTALLATIONS FOR SHALE SHAKER AREA W/I THIRTY (30) DAYS TO LOCAL OCMI.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Documentation
Issued 29 August 1984 Resolved
PROVIDE AN APPROVED COPY OF THE HAZARDOUS LOCATION PLAN AND PLACE ON BOARD THE RIG.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Lifesaving
Issued 29 August 1984 Resolved
REPLACE LIMIT SWITCH ON PORT BOAT DAVIT ASSEMBLY PRIOR TO MOVING RIG BUT NO LATER THAN 30SEP84.
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Electrical
Issued 29 August 1984 Resolved
REPAIR OR REPLACE ALARM WARNING LIGHT IN CEMENT(HALIBURTON) ROOM W/I 7 DAYS
Condition: Unknown
Due 29 August 1984
Resolved 29 August 1984
Lifesaving
Issued 17 April 1984 Resolved
PROVIDE LIFEBOAT PORTABLE RADIO FOR OCEANS ROUTE OR SUBMIT WRITTEN REQUEST TO OCMI TO HAVE ROUTE CHANGED TO OCEANS, NOT ON AN INTERNATIONAL VOYAGE.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Documentation
Issued 17 April 1984 Resolved
PROVIDE AN APPROVED COPY OF THE HAZARDOUS LOCATION PLAN AND PLACE ON BOARD THE RIG.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Documentation
Issued 17 April 1984 Resolved
PROVIDE EVIDENCE THAT THE MUD PIT AREA IS NOT A CLASS I, DIVISION 2 LOCA- TION OR INSTALL APPROVED EQUIPMENT FOR CLASS I, DIVISION 2 IN MUD PIT AREA.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Unknown
Issued 17 April 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE CLIFFS MARQUETTE, DN648999.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Documentation
Issued 11 April 1984 Resolved
PROVIDE AN APPROVED COPY OF THE HAZARDOUS LOCATION PLAN AND PLACE ON BOARD THE RIG.
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Unknown
Issued 11 April 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE CLIFFS MARQUETTE, DN648999.
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Documentation
Issued 11 April 1984 Resolved
PROVIDE EVIDENCE THAT THE MUD PIT AREA IS NOT A CLASS I, DIVISION 2 LOCA- TION OR INSTALL APPROVED EQUIPMENT FOR CLASS I, DIVISION 2 IN MUD PIT AREA.
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Lifesaving
Issued 11 April 1984 Resolved
PROVIDE PORTABLE RADIO AND EPIRB FOR OCEANS ROUTE OR SUBMIT WRITTEN REQUESTTO OCMI TO HAVE ROUTE CHANGED OT PERMIT DOMESTIC VOYAGES ONLY.
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Unknown
Issued 15 March 1984 Resolved
REPAIR THE WIRE HOLDER TO THE GENERAL ALARM BELL ON THE DECK HOUSE.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REPLACE THE RING LIFE BUOY ON THE PORT SIDE FORWARD.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REPLACE THE GENERAL ALARM BELL AND SIGN IN THE MUD PIT ROOM.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REPLACE THE MISSING SPANNER WRENCH AT FIRE STATIONS 12, 16, 17, 18, AND 20.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE CLIFFS MARQUETTE, DN648999.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REPLACE THE VALVE AT FIRE STATION 18.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REPAIR THE DOOR CLOSER ON THE PORT DOOR BY THE BOAT DOCK.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REPLACE THE GLASS IN THE EMERGENCY HALON RELEASE FOR THE ENGINE ROOM.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REPLACE THE GLASS IN THE GENERAL ALARM CONTACT MAKER IN THE SCR ROOM.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
INSTALL THE PLUG IN THE JUNCTION BOX ON THE PORT SIDE OF THE DECK HOUSE ON THE BOAT DECK.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
RESEAL ALL FIRE EXTINGUISHERS AS NEEDED.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
INSTALL A GENERAL ALARM SIGN IN THE ENGINE ROOM.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REMOVE THE SPARE PARTS FROM THE PANEL TOPS IN THE SCR ROOM.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
INSTALL A NEW DOOR ON THE PAINT LOCKER.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
DEMONSTRATE THAT THE EMERGENCY GENERATOR CAN ASSUME THE LOAD WITHIN THIRTY SECONDS.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
INSTALL A GASKET ON THE INBOARD WATER TIGHT DOOR IN THE EMERGENCY GENERATORROOM.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
TEST THE REVERSE POWER RELAYS ON THE FOUR S/S GENERATORS.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
PROPERLY TIE DOWN THE WIRES FOR THE DOG HOUSE MSA PANEL.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REMOUNT THE AUXILIARY DRUM PERFORMANCE CHART IN THE STARBOARD CRANE.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
OBTAIN A PORTABLE RADIO AND EPIRB FOR THE OCEANS ROUTE OR REQUEST A CHANGE OF ROUTE ON THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
CHANGE THE FUEL IN BOTH LIFEBOATS.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
CLEAN OUT BILGES IN BOTH LIFEBOATS.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REPLACE THE WIRE SEAL IN THE CLASS "A" BULKHEAD AFT OF HALIBURTON MACHINERYROOM.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
INSTALL THE MISSING BOLTS IN THE ELECTRICAL JUNCTION BOX IN MUD PIT.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REPLACE THE ELECTRICAL COVER ON THE SIDE OF THE EMERGENCY LIGHT IN THE SACKROOM.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
REPAIR THE PAINT LOCKER DOOR.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 15 March 1984 Resolved
MARK THE GENERAL ALARM BY FIRE STATION 12 AND ON THE DECK HOUSE.
Condition: Unknown
Due 15 March 1984
Resolved 15 March 1984
Unknown
Issued 23 August 1982 Resolved
SUBMIT STUCTURAL FIRE PROTECTION PLANS TO MMT FOR APPROVAL.
Condition: Unknown
Due 23 August 1982
Resolved 23 August 1982

Ownership record