Records from 1985 to 1992. Most recent: inspection, 6 July 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
6 July 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943264
20 April 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1266396
15 October 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249490
25 May 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223744
11 May 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223779
26 May 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1279849
14 April 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900508
3 April 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 896903
29 April 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 898996
2 December 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335491
28 July 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1333696
2 May 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018103
24 April 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1012321
18 April 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1295300
17 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 980236
27 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287739
Fire Fighting
Issued 11 May 1990
Resolved
MUST HYDROSTATICALLY TEST AND RECHARGE 3 B-II DRY CHEMICAL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Lifesaving
Issued 11 May 1990
Resolved
PROVIDE 10 ADULT PFD'S. VESSEL IS RESTRICTED TO 41 TOTAL PERSONS ON BOARD UNTIL REQUIREMENT IS MET.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Fire Fighting
Issued 14 April 1989
Resolved
HYDROTEST CO2 BOTTLES IN FIXED SYSTEM OR REMOVE FIXED SYSTEM AND INSTALL TWO B.II PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH 46CFR 181.30-1(A). IF FIXED SYSTEM IS RETAINED POST SIGN IN ENGINE ROOM READING "IF SIREN SOUNDS EVACUATE SPACE."
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Engineering
Issued 3 April 1989
Resolved
INSTALL STRAINER ON BILGE SUCTION IN BOYS' QUARTERS.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Construction/Loadline
Issued 3 April 1989
Resolved
ATTACH RETAINING CHAINS ON THE FOREPEAK, BOYS' QUARTERS AND GIRLS QUARTERS CIRCULAR HATCHES.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Engineering
Issued 24 April 1987
Resolved
PROVE PROPER OPERATION OF BOILER SAFETY VALVE.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Engineering
Issued 17 May 1985
Resolved
INSTALL VENTILATION DUCT IN THE ENGINE ROOM EXTENDING TO THE BILGE LEVEL.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Engineering
Issued 17 May 1985
Resolved
BENCH TEST THE PRESSURE RELIEF VALVE FOR THE HEATING BOILER OR REPLACE WITH COAST GUARD APPROVED VALVE.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Engineering
Issued 17 May 1985
Resolved
DEMONSTRATE PROPER OPERATION OF HEATING BOILER FLAME FAILURE SHUTOFF OF THESATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Fire Fighting
Issued 17 May 1985
Resolved
PRESSURE TEST THE FLEXIBLE HOSES FOR THE FIXED CO2 SYSTEM T0 1000 PSI.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Accommodation/Occupational Safety
Issued 27 April 1985
Resolved
PROVIDE WTD PORTSIDE MAIN DECK LEADING DOWN TO CREW ACCOMODATIONS.
Condition: Unknown
Due 27 April 1985
Resolved 27 April 1985
Accommodation/Occupational Safety
Issued 27 April 1985
Resolved
CROP AND INSTALL INSERT 2'X2' AT B STRAKE IN WAY OF BOW.
Condition: Unknown
Due 27 April 1985
Resolved 27 April 1985