Records from 1982 to 2010. Most recent: inspection, 6 November 2010.
Inspection history · 45
6 November 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3912540
14 April 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3464671
10 March 2008
Re-Inspection · Internal Structural Exam · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3161612
16 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2997475
6 April 2006
Examination of Repairs · Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2651720
20 April 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2338629
6 May 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2060691
8 April 2003
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1770124
8 April 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1602188
25 April 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452790
15 September 2000
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389191
31 March 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412077
16 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 769650
5 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210571
31 August 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046698
22 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1114316
21 April 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447934
1 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797651
2 February 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791087
19 August 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 216571
21 April 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470150
24 July 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383641
20 May 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445089
29 June 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431546
19 May 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450854
28 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 50107
19 April 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373833
12 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 642786
10 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 9256
8 October 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 642787
22 May 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1256003
17 May 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236836
13 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213582
8 April 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238889
13 March 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237715
31 May 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234063
1 June 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205798
30 January 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344516
1 June 1988
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204329
16 June 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328391
19 May 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337782
30 May 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988726
2 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980152
1 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281121
4 June 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969830
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 10 March 2008
Resolved
Demonstrate proper operation of both generator Over-speed devices.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2008
Resolution: Demonstrated.
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 10 March 2008
Resolved
Renew Safety Harness.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2008
Resolution: New harness provided.
Stability › Weathertight Integrity › General
Issued 10 March 2008
Resolved
Renew gaskets on Main Deck Door and Vent Closures.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2008
Resolution: New gaskets installed.
Engineering › Fuel Oil Service System › Filter
Issued 10 March 2008
Resolved
Install plugs and Heat Shields for Main Engine fuel filters.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2008
Resolution: Heat Shields fabricated and installed and plugs installed.
Fire Fighting › Nozzles › Condition
Issued 10 March 2008
Resolved
Renew (1) Fire Nozzle.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2008
Resolution: New all-purpose nozzle provided.
Engineering › Compressed Air System (start air) › Valve
Issued 10 March 2008
Resolved
Properly install Relief Valve in accordance with U1A.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2008
Resolution: Reducers removed and relief valve installed directly on tank.
Construction/Loadline › Structures › Deck Plating
Issued 10 March 2008
Resolved
Pipe washing machine drain into a tank and not the bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 14 April 2009
Communications › Public Address System › Announcing Station
Issued 16 July 2007
Resolved
Install a Public Address system on board vessel.
Due 13 August 2007
Resolved 17 July 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 16 July 2007
Resolved
All light fixtures in E/R and machinery room require stuffing tubes for wires going into fixture.
Due 13 August 2007
Resolved 20 August 2007
Resolution: Stuffing tubes installed where required.
Fire Fighting › Fire Hoses › Condition
Issued 6 April 2006
Resolved
Pinhole in stbd firehose. Replaced on the spot.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2006
Resolution: new hose readily available and installed.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 8 April 2002
Resolved
PROPERLY REPAIR STBD GENERATOR OVER SPEED PROTECTION DEVICE.
Condition: Improper/Lack of Maintenance
Due 8 April 2002
Resolved 8 April 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 April 2002
Resolved
PROVIDE UPDATED LIGHT LIST
Condition: Unknown
Due 8 April 2002
Resolved 8 April 2002
Lifesaving › Buoyant Apparatus
Issued 8 April 2002
Resolved
PROPERLY SECURE PADDLES FOR ALL LIFE FLOATS LEGACY COMPONENT DESC: PADDLES
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2002
Resolved 8 April 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 April 2002
Resolved
PROPERLY REWIRE AND SECURE WIRING FOR COMPASS LIGHT SWITCH
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2002
Resolved 8 April 2002
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 8 April 2002
Resolved
INSTALL PROPER FLAME RESISTANT SIGHT GLASSES ON ALL FUEL OIL AND LUBE OIL TANKS.
Condition: Improper Installation
Due 8 April 2002
Resolved 8 April 2002
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 April 2002
Resolved
REPAIR SMALL FUEL OIL LEAK IN THE PIPING FOR THE PORT FUEL OIL SERVICE TANK
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2002
Resolved 8 April 2002
Lifesaving
Issued 22 August 1999
Resolved
PROCEED DIRECTLY TO ALLIED SHIPYARD, LAROSE LA TO MAKE PERMANENT REPAIRS PRIOR TO OPERATING - CONTACT LOCAL OCMI FOR APPROVAL OF REPAIRS.
Condition: Unknown
Due 22 August 1999
Resolved 22 August 1999
Engineering
Issued 8 April 1991
Resolved
PROVIDE OVERSPEED DEVICES FOR BOTH MDE'S. PROVE OPERATION TO USCG MARINE _x001C_ INSPECTOR.
Condition: Unknown
Due 8 April 1991
Resolved 8 April 1991
Electrical
Issued 19 May 1987
Resolved
INSTALL GUARD AROUND PORT DIESEL GENERATOR PULLEY.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Deck/Cargo
Issued 19 May 1987
Resolved
PROVIDE ON BOARD OIL TRANSFER PROCEDURES, DESIGNATED PERSON IN CHARGE, AND CONDUCT REQUIRED TESTS OF OIL TRANSFER HOSE AS REQUIRED BY 33 CFR PARTS 154AND 155.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Navigation
Issued 19 May 1987
Resolved
PROVIDE APPROVED BULBS AND FIXTURE THAT MEET U.L. STANDARD 1104 FOR NAVLIGHTS, OR NAVLIGHTS THAT COMPLY WITH CURRENT NAVIGATION REGULATIONS.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Engineering
Issued 19 May 1987
Resolved
INSTALL FUEL OIL FILTERS APPROVED FOR MARINE USE, OR PROVIDE AFFADAVIT THATFILTERS HAVE BEEN TESTED TO MEET THE REQUIREMENTS OF NON-STANDARD FLUID CONDITIONOR FITTINGS, AS PER 46 CFR 56.07-5.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Unknown
Issued 2 July 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL [name withheld]647768
Condition: Unknown
Due 2 July 1985
Resolved 2 July 1985
Navigation
Issued 2 July 1985
Resolved
DEMONSTRATE PROPER OPERATION OF RUDDER ANGLE INDICATORS FROM BOTH STEERING POSITIONS TO THE SATISFACTION OF THE COGNIZANT OCMI PRIOR TO 02AUG85.
Condition: Unknown
Due 2 July 1985
Resolved 2 July 1985