MAURY USCG vessel records Sign in
← All vessels

SOUTHERN STAR I

SOUTHERN STAR I is a 1978 offshore supply vessel. The Coast Guard has recorded 63 inspections since 1982, most recently in July 2019, along with 45 deficiencies.

Records from 1982 to 2019. Most recent: inspection, 10 July 2019.

Built
1978
Last inspected
10 July 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7634305 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE6165
Flag
UNITED STATES
367004310, 367376750 (licence lapsed)
Maury page id
psix-53987

Inspections, by type

…with no type recorded8
Years with a record 31 calendar years (1982–2019)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it297 - Regulatory (Subpart C or D), Gross Ton
202 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE6165MMSI 367376750 · expired · compulsorily equipped · granted 12 September 2008, cancelled 17 November 2018
WBZ4686MMSI 367004310 · expired · compulsorily equipped · granted 2 June 1998, cancelled 8 November 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 63

10 July 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6759511
16 July 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6549543
27 May 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6142508
9 May 2012 Damage Survey · Administrative Inspection · MTSA Verification · Examination of Repairs · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4308589
15 April 2009 MTSA Verification · Ballast Water Examination · Administrative Inspection · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3458031
10 April 2008 Examination of Repairs · MTSA Verification · Administrative Inspection · Ballast Water Examination · Periodic Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3181346
18 May 2007 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2976476
2 March 2007 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2880566
10 January 2007 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2853677
11 June 2006 Re-Inspection · MTSA Verification · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2793487
19 April 2006 Drydock Extension
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2628488
7 June 2005 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2382304
11 May 2005 COI Inspection · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2354862
1 July 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2117967
13 April 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2035370
17 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978088
15 May 2003 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1793928
24 April 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1778585
29 April 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1610615
11 May 2001 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422056
28 April 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457788
22 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815393
30 November 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812657
1 November 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 796247
1 October 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041549
27 August 1999 Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369325
27 May 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801777
27 May 1999 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423154
1 May 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471148
26 June 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407920
14 June 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1190803
8 May 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454327
13 November 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 760469
11 November 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 26703
11 November 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 198796
27 June 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367351
5 May 1994 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469430
8 September 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1139815
10 August 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1155933
12 July 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415859
5 May 1992 COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422166
30 January 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1266926
24 September 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1248106
19 August 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939206
9 August 1991 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 935323
26 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 999390
19 April 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237815
2 August 1990 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 908390
25 June 1990 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1242104
12 June 1990 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 918813
7 March 1990 Hull Examination · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225371
24 October 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1241930
17 August 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 896344
1 August 1988 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1034799
21 June 1988 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 895787
7 August 1987 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1338768
8 May 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336336
27 January 1987 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1317395
16 July 1986 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1295039
20 June 1986 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 985391
2 October 1985 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 993848
9 June 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281447
10 June 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969532

Deficiency record · 45

Electrical › Electric Supply System (service) › Battery Charger
Issued 9 May 2012 Resolved
Make repairs to non-working battery charger in engine room
Due 11 June 2012
Resolved 7 May 2013
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2012 Resolved
Complete permanent repairs to tempory patch of main deck stbd side over stbd engine. Repairs are to be completed prior to or during next scheduled drydocking in 2013.
Action required: 705 - Other - as specified
Resolved 7 May 2013
Navigation › Piloting/Steering › Marine Charts
Issued 10 January 2007 Resolved
Provide navigation chart for area of operation.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 2 March 2007
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 10 January 2007 Resolved
Provide Ballast Water Management plan for vessel.
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 2 March 2007
Construction/Loadline › Hull › Bottom Plating
Issued 19 April 2006 Resolved
Vessel has been granted a drydock extension to expire 11JUN06.
Due 11 June 2006
Resolved 12 June 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 June 2005 Resolved
Vessel found in overloaded condition, Master to verify compliance with stability letter dated 6JUN78 prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2005
Resolved 7 June 2005
Fire Fighting › Fire Pumps
Issued 24 April 2003 Resolved
As per NVIC 1-78, vessel is required to have the ability to energize and monitor the firepump pressure from the pilot house. Vessel does not currently have this ability and is required to install a start/stop switch and pressure gage. LEGACY COMPONENT DESC: Power Source
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2003
Resolved 24 April 2003
Resolution: Installed necessary equipment as per NVIC 1-78. All equipment tested sat
Pollution Prevention/Response › Prevention Equipment
Issued 29 April 2002 Resolved
PROVIDE APPROVED OPERATIONAL TYPE II OR III MSD DEVICE ON BOARD. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Unknown
Due 30 July 2002
Resolved 14 April 2004
Fire Fighting › Miscellaneous Items
Issued 29 April 2002 Resolved
PROVIDE UPDATED FIRE SAFETY PLAN THAT REFLECTS EQUIPMENT ON BOARD VESSEL.
Condition: Unknown
Due 30 May 2002
Resolved 14 April 2004
Documentation
Issued 27 August 1999 Resolved
OBTAIN MSC APPROVAL OF DEADWEIGHT SURVEY/UPDATED STABILITY INFORMATION.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Documentation
Issued 27 August 1999 Resolved
OBTAIN MSC APPROVAL OF NEW LIQUID MUD PIPING PLANS.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Lifesaving
Issued 26 June 1997 Resolved
PROVIDE A LIFERAFT LAUNCHING ARRANGEMENT SO THAT THE RAFT MAY BE DEPLOYED FROM 01 LEVEL AND CLEAR THE MAIN DECK AND BULWARK.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Engineering
Issued 8 May 1996 Resolved
02. INSTALL APPROVED TYPE SIGHT GLASS IN ENGINE ROOM FUEL OIL DAY TANKS.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Engineering
Issued 8 May 1996 Resolved
01. REPAIR PILOTHOUSE CONSOLE MAIN ENGINE REMOTE STOPS.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Deck/Cargo
Issued 12 July 1993 Resolved
PROVIDE APPROVED PLANS FOR LIQUID MUD TANKS MODS.
Condition: Unknown
Due 12 September 1993
Resolved 8 September 1993
Construction/Loadline
Issued 5 May 1992 Resolved
BALLAST DISCHARGE PIPING ON DECK TO RE REMAIN BLANKED OFF UNTIL SUCH TIME_x001C_ VESSEL IS REMOVED FROM FREIGHT SHIP SERVICE.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Documentation
Issued 5 May 1992 Resolved
SUBMIT CALCULATIONS FOR STABILITY ANALYSIS TO MSC FOR CRANE INSTALLATION_x001C_ AND USAGE FOR ISSUANCE OF NEW STABILITY LETTER IF REQUIRED.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Deck/Cargo
Issued 5 May 1992 Resolved
LIQUID MUD TANK ARE TO REMAIN OUT OF SERVICE UNTIL THE CONDITIONS OF MSC-1_x001C_LTR DTD 06JUN92 ARE MET.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Navigation
Issued 9 August 1991 Resolved
MAKE REPAIRS TO PORT AND STBD RUNNING LIGHTS AND INSTALL APPROPRIATE BULBS.
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Documentation
Issued 9 August 1991 Resolved
PLACE ONBOARD WASTE MANAGEMENT PLAN FOR VESSEL.
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Fire Fighting
Issued 9 August 1991 Resolved
REMOVE ALL PAINT OR INSTALL FIXED FIREFIGHTING SYSTEM FOR PAINT LOCKER.
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Deck/Cargo
Issued 9 August 1991 Resolved
REPAIR OR RENEW RELIEF VALVES ON DRY BULK TANKS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Electrical
Issued 9 August 1991 Resolved
PROVE PROPER OPERATION OF GROUND DETECTION SYSTEM FOR MAIN SWICHTBOARD.
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Electrical
Issued 9 August 1991 Resolved
PROVIDE ADEQUATE E-LIGHTING FOR ENGINE ROOM AND ESCAPE HATCHES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Electrical
Issued 9 August 1991 Resolved
REPAIR E-LIGHT LOCATED IN THE PILOTHOUSE.
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Navigation
Issued 9 August 1991 Resolved
MAKE REPAIRS TO NAVIGATIONAL LIGHT PANEL AND TEST
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Engineering
Issued 9 August 1991 Resolved
PROVIDE AIR RECEIVERS WITH APPROPRIATE RELIEVING EQUIPMENT.
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Deck/Cargo
Issued 19 April 1991 Resolved
SUBMIT PLANS AND STRENGTH CALCULATIONS FOR LIQUID MUD TANK MODIFICATIONS_x001C_ TO THE USCG MARINE SAFETY CENTER FOR APPROVAL.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Engineering
Issued 12 June 1990 Resolved
INSTALL APPROVED FITTINGS ON DRY BULK COMPRESSOR DIESEL ENGINE FLEXIBLE FUEL RETURN LINE.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Electrical
Issued 12 June 1990 Resolved
INSTALL APPROVED BATTERY CABLE CLAMPS ON STBD GENERATOR STARTING BATTERY CABLES.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Fire Fighting
Issued 12 June 1990 Resolved
REPAIR/RENEW ONE ALL PURPOSE FIRE NOZZLE.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Deck/Cargo
Issued 12 June 1990 Resolved
HYDRO TEST CARGO HOSES TO 1.5 TIMES MANUFACTURER'S RATED WORKING PRESSURE AND PROVIDE DOCUMENTATION.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Engineering
Issued 12 June 1990 Resolved
PROVE PROPER OPERATION OF ENGINEERING AUTOMATED CONTROL/MONITORING SYSTEMS AND PROVIDE COPY OF SERVICE CERTIFICATE.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Fire Fighting
Issued 12 June 1990 Resolved
PROVIDE REMOTE STOP/START CONTROL IN PILOTHOUSE FOR FIRE PUMP. .
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Construction/Loadline
Issued 12 June 1990 Resolved
PROVIDE REMOTE SHUTDOWN FOR DIRTY OIL PUMP BY DECK DISCHARGE CONNECTION.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Deck/Cargo
Issued 12 June 1990 Resolved
REPAIR/RENEW TWO DRY BULK RELIEF VALVES AND PROVE PROPER OPERATION.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Engineering
Issued 12 June 1990 Resolved
PROVE PROPER OPERATION OF P&S MAIN PROPULSION DIESEL ENGINE OVERSPEED TRIPS
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Lifesaving
Issued 12 June 1990 Resolved
PROVIDE 1 HYDROSTATIC RELEASE FOR STBD RAFT. TOTAL PERSONS CARRIED RE- STRICTED TO 10 UNTIL CORRECTED.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Navigation
Issued 17 August 1989 Resolved
PORT RADAR NOT OPERATING.
Condition: Unknown
Due 17 August 1989
Resolved 17 August 1989
Electrical
Issued 17 August 1989 Resolved
PRIOR TO OPERATION OF #2 SHIP SERVICE GENERATOR MAKE REPAIRS TO OVERSPEED TRIP AND SHOW PROPER OPERATION IN PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 17 August 1989
Resolved 17 August 1989
Electrical
Issued 17 August 1989 Resolved
NUMEROUS GLOBES MISSING ON LIGHT FIXTURES IN MACHINERY SPACE AND STEERING GEAR SPACE.
Condition: Unknown
Due 17 August 1989
Resolved 17 August 1989
Electrical
Issued 17 August 1989 Resolved
MAKE REPAIRS TO CONTROL KNOB FOR #2 AIR COMPRESSOR MOTOR CONTROLLER IN MACHINERY SPACE.
Condition: Unknown
Due 17 August 1989
Resolved 17 August 1989
Fire Fighting
Issued 21 June 1988 Resolved
CONDUCT FIRE AND BOAT DRILL.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Fire Fighting
Issued 20 June 1986 Resolved
CONDUCT A FIRE DRILL WITHIN 24 HOURS PRIOR TO THE CREW REPORTING ONBOARD. NOTIFY [name withheld], IN WRITING WHEN COMPLETED.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Lifesaving
Issued 2 October 1985 Resolved
PROVIDE ONBOARD 12 APPROVED HANDHELD ROCKET PROPELLED PARACHUTE RED FLARE DISTRESS SIGNALS (160.036) PRIOR TO OPERATING THE VESSEL IN OCEANS OR UNDERWAY AFTER SUNRISE, BUT NO LATER THAN 31JAN86.
Condition: Unknown
Due 2 October 1985
Resolved 2 October 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.