RED EAGLE is a 1982 offshore supply vessel. The Coast Guard has recorded 36 inspections since 1982, most recently in November 2008, along with 105 deficiencies.

Records from 1982 to 2008. Most recent: inspection, 24 November 2008.

Built
1982
Last inspected
24 November 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5432
Flag
UNITED STATES
367041020 (licence lapsed)
Maury page id
psix-53990

Inspections, by type

…with no type recorded9
Years with a record 24 calendar years (1982–2008)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC5432MMSI 367041020 · expired · compulsorily equipped · granted 11 May 2005, cancelled 11 July 2015
WAL4638MMSI not assigned · expired · compulsorily equipped · granted 17 June 1998, cancelled 20 August 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 36

24 November 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3368498
17 October 2006 Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2802570
18 September 2006 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2781021
30 September 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2504614
10 May 2005 Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2354378
9 August 2004 Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2160755
12 December 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1963316
31 July 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1862553
18 March 2003 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1759207
7 August 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1657993
5 July 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443213
5 May 2000 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408500
9 November 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804251
20 May 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434878
23 March 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372204
18 March 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442675
30 August 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 183835
16 June 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371867
11 April 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387975
24 May 1995 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414458
13 April 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362956
3 August 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 672961
28 July 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 137638
16 March 1993 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373808
20 April 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265000
12 June 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231932
8 May 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240489
21 October 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323586
29 January 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012005
20 March 1986 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306923
29 November 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996082
5 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289350
5 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290498
7 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973368
2 December 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971703
14 June 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966247

Deficiency record · 105

Construction/Loadline › Structures › Deck Plating
Issued 17 October 2006 Resolved
Crop and Renew hole in overhead of engine room in way of the emergency exit in accordance with NVIC 07-68. Insert shall be at least 18" by 18".
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2006
Resolution: The plate in the area of the hole was cropped out and inserted.
Stability › Weathertight Integrity › General
Issued 17 October 2006 Resolved
Prove proper operation of the hatch for the emergency exit from the engine as required by 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 18 November 2006
Resolved 8 December 2006
Resolution: The entire hatched was removed and renewed.
Engineering › Compressed Air System (control) › Valve
Issued 17 October 2006 Resolved
Remove the unapproved regulator on the air receiver or replace with an approved regulator in accordance with 46 CFR 54.
Action required: 705 - Other - as specified
Due 18 November 2006
Resolved 8 December 2006
Resolution: The regulation was removed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 October 2006 Resolved
Provide deck railing around the bow of the vessel as required by 46 CFR 177.900
Action required: 705 - Other - as specified
Due 18 November 2006
Resolved 8 December 2006
Resolution: This requirement was withdrawn because the rails would interfere with the dive operations.
Documentation › Markings/Placards › Garbage Placard
Issued 18 September 2006 Resolved
Provide a waste management plan in accordance with 33 CFR 151.57.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Provided a waste management plan
Stability › Watertight Integrity › Deadlight Cover
Issued 18 September 2006 Resolved
Repair or replace broken port light in the pilothouse on the aft starboard side in accordance with 46 CFR 177.1010.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Removed port light and covered with steel plate
Stability › Watertight Integrity › Deadlight Cover
Issued 18 September 2006 Resolved
Provide a galley port light cover in accordance with 46 CFR 171.117.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 8 December 2006
Resolution: A port light cover was properly installed.
Operations/Management › Vessel Safety Management › Designated Person(s)
Issued 18 September 2006 Resolved
Provide a crew only sign for restricted area at forward peak in accordance with 46 CFR 185.602.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Fire Fighting › Fire Pumps › Arrangement
Issued 18 September 2006 Resolved
Prove operation of fire pump guages in accordance with 46 CFR 181.300.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Replace the fire pump gauge and proved its operation
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 18 September 2006 Resolved
Prove operation of bilge high level alarms in accordance with 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 8 December 2006
Resolution: The bilge high level was tested with satisfactory results.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 September 2006 Resolved
Provide guard for bulb in the engine room in accordance with 46 CFR 183.410.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Provided guard for bulb
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 September 2006 Resolved
Clean bilges and make ready for inspection in accordance with 46 CFR 176.830.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 8 December 2006
Resolution: The bilge was professionally cleaned.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 18 September 2006 Resolved
Replace air receiver relief and make operational in accordance with 46 CFR 176.812.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Replaced air receiver relief valve and made operational
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 18 September 2006 Resolved
Make all lights in the engine room operational in accordance with 46 CFR 183.410.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Made all lights operational
Electrical › Electric Generation Source (service) › Generator
Issued 18 September 2006 Resolved
Clean both generator windings in accordance with 46 CFR 183.322.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 8 December 2006
Resolution: Both generator windings were removed and professionally clean.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2006 Resolved
Secure electrical wiring in the pilothouse in according with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Secured all electrical wiring
Electrical › Electric Generation Source (service) › Generator
Issued 18 September 2006 Resolved
Replace BX connector on generator two.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 8 December 2006
Resolution: The BX connectors were removed.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 18 September 2006 Resolved
Provide electrical grade rubber mat for under the switchboard in accordance with 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Provided eletrical grade rubber mat
Engineering › Fuel Oil Service System › Valve
Issued 18 September 2006 Resolved
Replace valve handle for main engine fuel supply in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Replaced valve handle
Engineering › Fuel Oil Service System › Filter
Issued 18 September 2006 Resolved
Provide plug for racor fuel filter drain in accordance with 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Provided plugs
Electrical › Electric Generation Source (service) › Generator Cable
Issued 18 September 2006 Resolved
Remove or install wire to #1 generator freshwater day tank.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Installed the wire
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 September 2006 Resolved
Remove wire nuts from bilge pump.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 8 December 2006
Resolution: The bilge pump was properly wired.
Engineering › Bilge Water Management System › Piping
Issued 18 September 2006 Resolved
Support freshwater pipe in way of bilge pump.
Action required: 705 - Other - as specified
Due 18 October 2006
Resolved 18 October 2006
Resolution: Welded a support for the pipe
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 20 June 2005 Resolved
Provide for review, transfer procedures in accordance with 33 CFR 155.750 as required by 33 CFR 155.720 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 21 July 2005
Resolved 18 October 2006
Resolution: Not required
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 May 2005 Resolved
Paint draft marks IAW 46 CFR 185.602.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 3 June 2005
Resolution: Draft marks were painted an opposing color as required.
Construction/Loadline › Hull › Bracket
Issued 11 May 2005 Resolved
Repair/renew 4 tripping brackets in lazarett IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: Tripping brackets cropped and renewed IAW NVIC 7-68.
Construction/Loadline › Hull › Weld
Issued 11 May 2005 Resolved
Weld 3 areas in weather deck where not welded from below IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 3 June 2005
Resolution: All areas were welded from above and below IAW NVIC 7-68.
Construction/Loadline › Hull › Side Shell
Issued 11 May 2005 Resolved
Insert 2 areas in aft void where excessively inset IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 3 June 2005
Resolution: Inserts were installed IAW NVIC 7-68 and hose tested satisfactorily.
Construction/Loadline › Hull › Bottom Plating
Issued 11 May 2005 Resolved
Provide ultrasonic testing at 6 marked areas on stern wrap IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: Ultrasonic testing was provided and the plate thickness was satisfactory.
Stability › Watertight Integrity › General
Issued 11 May 2005 Resolved
Restore watertight integrity breached by pipe transiting aft watertight bulkhead IAW 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 3 June 2005
Resolution: Pipe transiting bulkhead was capped on both sides IAW 46 CFR 179.360.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 11 May 2005 Resolved
Renew/repair 2 doubler plates and epoxy patch found in aft bulkhead on potable water tank IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 3 June 2005
Resolution: Area were cut out and 2 inserts were installed IAW NVIC 7-68.
Construction/Loadline › Hull › Weld
Issued 11 May 2005 Resolved
Insert in main deck above steering gear compartment not welded from below. Weld from below IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: Insert was welded from above and below IAW NVIC 7-68.
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 May 2005 Resolved
Renew/repair cracked weld on stbd. outboard longitudinal IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 3 June 2005
Resolution: Weld was ground out and rewelded IAW NVIC 7-68.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 11 May 2005 Resolved
Renew/repair 7 cracked welds located on stiffeners adjactent to potable water tank IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 3 June 2005
Resolution: All welds were ground and rewelded IAW NVIC 7-68.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 11 May 2005 Resolved
Renew/repair 2 cracked welds located on stiffeners adjacent to potable water tank in stbd. ballast tank IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: Both welds were ground out and rewelded IAW NVIC 7-68.
Stability › Watertight Integrity › General
Issued 11 May 2005 Resolved
Renew/repair reach rod in forepeak bilge piping IAW NVIC 46 CFR 182.510.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: Reach rod was repaired and operable IAW NVIC 46 CFR 182.510.
Stability › Watertight Integrity › General
Issued 11 May 2005 Resolved
Renew/repair hole in forward bulwark on port outboard side IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: Hole in bulwark was clad welded IAW NVIC 7-68.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 11 May 2005 Resolved
Remove excess oil from bilge.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: Oil was removed from bilge.
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 May 2005 Resolved
Renew/repair 8 cracked welds in overhead logitudinals of potable water tank IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: All 8 welds were ground and rewelded IAW NVIC 7-68.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 11 May 2005 Resolved
Renew/repair support column in potable water tank IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: Break in support column was ground out and rewelded IAW NVIC 7-68.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 May 2005 Resolved
Repair all electrical cables under the pilothouse console by installing proper wire connectors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: corrected
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 May 2005 Resolved
Provide a proper battery box under the pilothouse console
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: removed.
Electrical › Electric Supply System (service) › Battery Charger
Issued 10 May 2005 Resolved
Provide a proper marine type battery charger for the bridge radios.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: Removed.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 May 2005 Resolved
Provide an updated compass deviation card.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: provided.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 May 2005 Resolved
Install the emergency light in the pilothouse.
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: installed
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 May 2005 Resolved
Prove bilge alarm for the rudder compartment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: demonstrated.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 May 2005 Resolved
Install guards on all emergency lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: installed.
Engineering › Fuel Oil Service System › Hose
Issued 10 May 2005 Resolved
Provide and install chafing gear on the following hoses; starboard main engine reduction gear, starboard main engine fuel oil hoses, port main engine fuel oil hoses, and the port reduction gear hoses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: installed
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2005 Resolved
Properly secure all overhead wiring in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 10 May 2005 Resolved
Rewrap / reposition the exhaust blankets for the starboard main engine exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: moved.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 May 2005 Resolved
Repair or replace the motor controller box for the fire/ ballast pump electrical controller.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: replaced.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 May 2005 Resolved
Repair / replace the cable strain eze connector for the fire/ballast pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 May 2005 Resolved
Repair the overhead light in the engine room between the starboard main engine and the fuel oil pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: replaced.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 May 2005 Resolved
Install proper blanking devices at all open slots in the electrical panels in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: installed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 May 2005 Resolved
Provide and install proper circuit directory cards for all engine room electrical panels
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: provided
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 10 May 2005 Resolved
Properly secure the washing machine
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: secured
Electrical › Electrical Distribution System (emergency) › Cable
Issued 10 May 2005 Resolved
Secure the engine room battery charger power supply cable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: secured.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 10 May 2005 Resolved
Install flame resistant glass with guards on the engine room lube oil tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: installed
Electrical › Electrical Distribution System (service) › Cable
Issued 10 May 2005 Resolved
Repair the dryer electrical supply cable plug.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 May 2005 Resolved
Repair or replace all bunk lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: corrected
Electrical › Electrical Distribution System (service) › Switch
Issued 10 May 2005 Resolved
Provide a switch cover for the starboard aft berth light switch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: installed
Fire Fighting › Fire Main › Condition
Issued 10 May 2005 Resolved
Prior to sailing properly repair the fire main piping for the starboard main deck fire station.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2005
Resolved 20 June 2005
Resolution: corrected. Tested to dead head pressure of the fire pump.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 May 2005 Resolved
Repair or replace the port and starboard navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: replaced.
Lifesaving › Lifefloat › Serviceable
Issued 10 May 2005 Resolved
Prior to sailing repair or replace the lifefloats as discussed. During reinstallation properly rig the lifefloats and the weak link to allow float free operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2005
Resolved 20 June 2005
Resolution: replaced floats and rigged properly.
Construction/Loadline › Structures › Door
Issued 10 May 2005 Resolved
Repair the hinges for the pilothouse port and starboard doors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: repaired.
Engineering › Bilge Water Management System › Valve
Issued 10 May 2005 Resolved
Repair and prove operation of the forepeak reach rod and main deck penetration pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: repaired.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 May 2005 Resolved
Provide updated Navigation publications to include Coast Pilots [name withheld], Tides and Currents and notice to mariners.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: provided
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 May 2005 Resolved
Provide 03 additional type I life jackets, with proper donning instructions.
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: Provided.
Accommodation/Occupational Safety › Potable Water System › General
Issued 10 May 2005 Resolved
Install correctly rated water heater relief valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: Installed.
Accommodation/Occupational Safety › Potable Water System › General
Issued 10 May 2005 Resolved
Secure the potable water pressure sets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: secured
Engineering › Fuel Oil Service System › Piping
Issued 10 May 2005 Resolved
Secure the fuel oil piping to the port and starboard generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: secured.
Engineering › Steering Gear System › Power Unit
Issued 10 May 2005 Resolved
Prove operation of the steering system.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2005
Resolved 10 June 2005
Resolution: demonstrated
Operations/Management › Drills/Instruction › Fire
Issued 10 May 2005 Resolved
Demonstrate proper crew drills: Fire, Abandon ship, and man-overboard
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: demonstrated.
Personnel › Training › First Aid/CPR
Issued 10 May 2005 Resolved
Provide first aid cards for 50% of the crew.
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: provided.
Personnel › Training › Watchkeeping
Issued 10 May 2005 Resolved
Provide FCC radio operators licenses for 2 persons.
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: provided.
Engineering › Steering Gear System › Ram
Issued 10 May 2005 Resolved
Add chafing gear on hoses for the steering system in the area of the tiller arm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 20 June 2005
Resolution: installed.
Stability › Watertight Integrity › General
Issued 10 May 2005 Resolved
Repair/renew crack in seam of port aft seam in bulwark IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: Crack was welded satisfactorily.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 10 May 2005 Resolved
Renew/repair fallen angel support in potable water tank IAW NVIC 7-68.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 June 2005
Resolution: Support was rewelded into place IAW NVIC 7-68.
Lifesaving › Lifebuoys
Issued 31 July 2003 Resolved
ARRANGE LIFE FLOATS FOR A FLOAT FREE DESIGN. LEGACY COMPONENT DESC: Stowage
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2003
Resolved 1 August 2003
Lifesaving › Lifebuoys
Issued 31 July 2003 Resolved
MARK VESSEL NAME AND CAPACITY ON ONE LIFE FLOAT. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2003
Resolved 1 August 2003
Lifesaving › Lifebuoys
Issued 31 July 2003 Resolved
ATTACH EACH LIFE FLOAT TO THE PAINTER OR PROVIDE A PAINTER FOR EACH WITH A WEAK LINK. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2003
Resolved 1 August 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 July 2003 Resolved
RESTOCK FIRST AID KIT.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2003
Resolved 1 August 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 31 July 2003 Resolved
PROVIDE CORRECT LIFE JACKET DONNING INSTRUCTIONS. LEGACY COMPONENT DESC: DONNING INSTRUCTIONS
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2003
Resolved 1 August 2003
Communications › Visual Communication
Issued 31 July 2003 Resolved
PROVIDE AND POST EMERGENCY INSTRUCTIONS. LEGACY COMPONENT DESC: EMERGENCY INSTRUCTIONS
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 August 2003
Resolved 1 August 2003
Engineering › Fuel Oil Service System
Issued 31 July 2003 Resolved
RENEW STARBOARD GENERATOR FUEL OIL RETURN LINE FLEXIBLE HOSE WITH HOSE MEETING J 1942. LEGACY COMPONENT DESC: Hose
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 August 2003
Resolved 1 August 2003
Engineering › Compressed Air System (start air)
Issued 31 July 2003 Resolved
PROVIDE AND INSTALL GUARD ON AIR COMPRESSOR MOTOR SHAFT AND PULLEY. LEGACY COMPONENT DESC: Compressor
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2003
Resolved 1 August 2003
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 31 July 2003 Resolved
PROVIDE AND INSTALL MISSING LAGGING FOR BOTH MAIN ENGINE EXHAUST PIPING.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2003
Resolved 1 August 2003
Electrical › Electrical Distribution System (service)
Issued 31 July 2003 Resolved
REMOVE EXTENSION CORD USED AS PERMANENT WIRING FOR FREEZER IN ENGINE ROOM. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 August 2003
Resolved 1 August 2003
Engineering › Diesel Engine (auxiliary)
Issued 31 July 2003 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH GENERATORS OVER SPEED PROTECTION DEVICES. LEGACY COMPONENT DESC: OVER CURRENT DEVICE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2003
Resolved 1 August 2003
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 7 August 2002 Resolved
Draft marks not painted.
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 8 August 2002
Construction/Loadline › Markings
Issued 7 August 2002 Resolved
Vessel name not painted on stern. LEGACY COMPONENT DESC: Vessel Name/Home Port
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 8 August 2002
Lifesaving › Hand Flares
Issued 7 August 2002 Resolved
One orange smoke flare missing. LEGACY COMPONENT DESC: Quantity
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2002
Resolved 8 August 2002
Navigation › Piloting/Steering
Issued 7 August 2002 Resolved
Compass light not working. LEGACY COMPONENT DESC: Magnetic Compass
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2002
Resolved 8 August 2002
Navigation › Collision/Grounding Avoidance
Issued 7 August 2002 Resolved
Vessel did not have approved bulbs in lights. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 8 August 2002
Communications › Radio Communications
Issued 7 August 2002 Resolved
The registration was not available at the time of the inspection, and the hydrostatic release was not marked with an expiration date. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 27 August 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 7 August 2002 Resolved
Kit needs to be restocked. LEGACY COMPONENT DESC: First Aid Kit
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 8 August 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 August 2002 Resolved
Numerous pieces of exhaust lagging missing. LEGACY COMPONENT DESC: Silencer (exhaust)
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 27 August 2002
Stability › Watertight Integrity
Issued 7 August 2002 Resolved
Emergency escape hatch from engine room needs to be adjusted. LEGACY COMPONENT DESC: Watertight Hatch
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2002
Resolved 8 August 2002
Fire Fighting › Means of Escape
Issued 7 August 2002 Resolved
The emergency escape from engine room was not stenciled. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 8 August 2002
Engineering › Fuel Oil Service System
Issued 7 August 2002 Resolved
Numerous ball checks not working and flame screens need to be replaced. LEGACY COMPONENT DESC: Vent Pipe
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2002
Resolved 27 August 2002
Engineering › Fuel Oil Service System
Issued 7 August 2002 Resolved
Petcocks on the raycor filters are not of an approved type. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 27 August 2002
Personnel › Certificates/Documents/Licenses
Issued 7 August 2002 Resolved
There was no licensed member of the crew that held a FCC radio operator permit. Provide a copy of FCC License for one licensed member of the crew. LEGACY COMPONENT DESC: License, Radio Operator
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 31 July 2003
Documentation › Certificates/Documents
Issued 7 August 2002 Resolved
Vessel did not have a stability letter onboard. LEGACY COMPONENT DESC: Stability Letter
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 27 August 2002
Electrical › Lighting (service)
Issued 7 August 2002 Resolved
A couple of lights in the engine room did not have covers. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 8 August 2002
Construction/Loadline
Issued 20 May 1999 Resolved
INSTALL HIGH LEVEL BILGE ALARM IN RUDDER ROOM AND PROVIDE A VISUAL AND AUDIBLE ALARM IN THE OPERATING STATION TO INDICATE HIGH WATER LEVEL FOR EACH SPACE IAW 46 CFR 182.115 (d) (APPLICABILITY TO EXISTING VESSELS) AND 46 CFR 182.530.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999

Ownership record