Records from 1982 to 2005. Most recent: inspection, 1 February 2005.
Inspection history · 49
1 February 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2284748
12 October 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2219038
23 April 2004
Administrative Inspection · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2050753
23 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972145
25 August 2003
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1887022
17 February 2001
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1471416
5 October 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1055065
20 March 2000
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372992
18 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770511
15 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210050
17 August 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1397223
2 July 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472802
5 March 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119667
5 February 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 28655
1 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783970
27 August 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383659
14 February 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 81344
17 September 1996
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 957528
1 July 1996
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1088638
28 June 1996
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 933988
29 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 656338
16 April 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1081116
22 November 1995
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411198
21 November 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 89404
15 November 1995
COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1421040
9 June 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 876244
11 April 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367022
7 January 1994
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 851356
30 September 1993
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1155237
26 September 1993
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1158644
5 April 1993
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 825834
15 April 1992
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 948229
8 May 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1211637
5 October 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 908648
25 September 1990
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1217213
29 June 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1214308
21 June 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1239382
15 May 1990
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 929601
29 June 1989
Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1028916
30 September 1988
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1196117
20 May 1988
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 891920
4 September 1987
Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1000182
22 April 1987
Deficiency Check · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1013302
28 October 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1011961
21 May 1986
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 987324
12 September 1985
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1297794
15 June 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 983025
10 March 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969960
16 June 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 964335
Electrical › Electric Generation Source (emergency)
Issued 25 August 2003
Resolved
Engineroom batteries are currently housed in a steel box without some form of non-conductive liner.(Lead) Vessel is purchasing (2) plastic, approved battery boxes. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 1 October 2003
Resolution: Battery boxes were procured and batteries were properly installed.
Pollution Prevention/Response › Prevention Equipment
Issued 25 August 2003
Resolved
Overboard valve on O.W.S does not completely stop the flow overboard when system senses oil content over 15 ppm. Current condition allows some oil to discharge overboard when it should be recirculating. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 1 October 2003
Resolution: New overboard valve and coil was installed on oily water seperator. Conducted test of system in overboard and recirc mode, all tests sat.
Engineering › Fuel Oil Service System
Issued 25 August 2003
Resolved
Fuel oil centrifuge has several unacceptable leaks and continuously pumps diesel out while in normal operation. Vessel must repair leaks prior to use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 1 October 2003
Resolution: Proper replacement parts were purchased and installed. Fuel oil centrifuge was tested and appeared leak free.
Engineering
Issued 17 February 2001
Resolved
During extensive replacement of portions of the keel cooler and hull duringdrydock, the cooling system piping for the Starboard MDE was improperly reinstalled causing the cooling water to escape out of the main deck vent.
Condition: Unknown
Due 17 February 2001
Resolved 27 February 2001
Engineering
Issued 17 August 1999
Resolved
"O" RING FOR FUEL NOZZLE LEAKING ON PORT MAIN ENGINE INBOARD, NO. 5 CYLINDER
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
WATERTIGHT DOOR FOR DECK HOUSE ACCESS TO AFT DECK FOUND WITH TWO DOGS FROZEN IN UN-DOGGED POSITION.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
WTD FWD BULKHEAD ENGINE ROOM NOT WATERTIGHT
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Construction/Loadline
Issued 17 August 1999
Resolved
WATERTIGHT DOOR AFT ENGINE ROOM NOT WATERTIGHT
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Engineering
Issued 17 August 1999
Resolved
FUEL OIL FLEX HOSE FROM RACOR TO PORT MAIN ENGINE LEAKING AT FITTING.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Lifesaving
Issued 15 November 1995
Resolved
CONDUCT FIRE, ABONDON SHIP, AND RESCUE DRILLS.
Condition: Unknown
Due 30 November 1995
Resolved 12 December 1995
Deck/Cargo
Issued 11 April 1994
Resolved
Make ready for internal inspection four (4) dry bulk tanks at the next scheduled drydock.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Accommodation/Occupational Safety
Issued 11 April 1994
Resolved
Install proper relief valve on vessel hot water heater.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Engineering
Issued 15 May 1990
Resolved
PERFORM ENGINE ALARM SYSTEM CHECK AND PROVIDE COPY OF SERVICE CERTIFICATE. REF. NVIC 1-69 & 1-78.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
INSTALL APPROVED CLAMPS ON BATTERY CABLE FOR GENERATOR STARTING BATTERIES.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
INSTALL STUFFING TUBES ON AFT DECK LIGHT WIRING ENTERING SWITCH BOX IN ENG ROOM ESCAPE PASSAGE STBD.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
REPAIR LOOSE STUFFING TUBES ON FWD AIR COMPRESSOR PRESSURE SWITCH AND SOLE-NOID SWITCH.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
MAKE PERMANENT REPAIRS TO STEERING ALARM AUDIBLE ALARM AND 3 EXTINGUISHED ALARM INDICATOR LIGHTS AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Fire Fighting
Issued 15 May 1990
Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS BY 30JUN90 AND PROVIDE COPY OF SERVICE CERTIFICATE.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
MAKE PERMANENT REPAIRS TO #1 STEERING PUMP AUTO/MANUAL SELECTOR SWITCH IN ENGINE ROOM.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Electrical
Issued 15 May 1990
Resolved
INSTALL STUFFING TUBE ON AFT EMERGENCY LIGHT WIRE ENTERING JUNCTION BOX IN PASSAGEWAY TO ENGINE ROOM IN VICINITY OF #5 TANK STBD.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Engineering
Issued 22 April 1987
Resolved
PRODUCE ON BOARD A COPY OF THE AUTOMATION TEST PROCEDURE APPROVED FOR THIS VESSEL. MAKE THE TEST PROCEDURE AVAILABEL FOR INSPECTION BY A COAST GUARD MARINE INSPECTOR BY 21MAY87.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Electrical
Issued 22 April 1987
Resolved
MAKE PERMANENT REPAIRS TO OVERSPEED PROTECTIVE DEVICE FOR STARBOARD SHIP SERVICE GENERATOR. REPAIRS TO BE MADE AND DEMONSTRATED TO THE SATISFACTION OF THE COGNIZANT [name withheld] 02MAY87.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Engineering
Issued 22 April 1987
Resolved
MAKE PERMANENT REPAIRS TO THE DIGITAL SHAFT TACHOMETER INDICATOR FOR THE PORT SHAFT, LOCATED IN THE ENGINE ROOM. REPAIRS TO BE MADE NO LATER THAN 21MAY87.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987