Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named TAHOE CRUZ
TAHOE CRUZ is a 1982 passenger vessel (inspected). The Coast Guard has recorded 77 inspections since 1985, most recently in May 2025, along with 111 deficiencies and 2 casualty investigations between 2010 and 2016.
Records from 1985 to 2025. Most recent: inspection, 14 May 2025.
- Built
- 1982
- Last inspected
- 14 May 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 111 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2010–2016
Identity
645961
WCB9227
54000
Flag
UNITED STATES
—
Maury page id
psix-54000
Inspections, by type
…with no type recorded11
Years with a record
37 calendar years (1985–2025)
The 77 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)48.5 ft × 12.0 ft × 5.2 ft
Registered tonnagegross 16 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBILL LEE YACHTS INC · SOQUEL, CA, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTAHOE CITY, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 77
14 May 2025
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8118784
26 April 2025
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8126334
14 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7920758
17 May 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681332
4 May 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7452363
28 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7189014
26 April 2021
Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7182343
9 December 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7109068
8 October 2020
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070341
10 June 2020
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949467
30 April 2020
Drydock Extension · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6946535
16 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681525
8 May 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6410554
5 June 2017
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6163792
22 July 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5963501
4 April 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5863192
18 August 2014
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4979798
10 June 2014
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4877411
18 July 2012
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4404998
6 July 2012
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4370073
12 June 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4335198
6 February 2012
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4239529
15 August 2011
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4116458
30 November 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3901481
15 May 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3211038
19 June 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2968086
6 September 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2770892
24 July 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2709282
6 June 2005
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2376848
6 May 2005
Hull Examination · Construction Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2353038
21 April 2005
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2339731
3 November 2004
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2228917
11 March 2004
In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2022997
10 October 2003
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1925701
3 December 2002
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1713679
19 November 2002
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1708326
10 April 2001
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1399591
5 March 2001
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1060387
25 February 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 796378
16 September 1998
Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1449104
11 February 1998
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1456574
16 May 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396732
13 February 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377947
17 October 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 848291
18 September 1996
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377818
29 July 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 35727
1 May 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367725
6 March 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371322
6 September 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 382517
9 August 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 880106
13 July 1995
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387828
17 June 1995
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1469790
19 April 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358735
5 March 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 141343
3 March 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1405500
5 November 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1407226
3 September 1993
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358167
10 March 1993
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1146017
8 May 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1267328
16 March 1992
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1256923
26 September 1991
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1247724
7 March 1991
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1224791
12 June 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1220969
13 March 1990
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 923443
5 March 1990
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 905647
18 April 1989
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1037079
8 March 1989
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1032365
16 March 1988
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1340657
18 December 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1010083
7 December 1987
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1311593
7 April 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1021798
19 March 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1018564
5 June 1986
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1297517
29 April 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 986373
18 April 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1287734
18 March 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 980482
26 February 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 982448
Deficiency record · 111
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2025
Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs... The vessel lacked documentation for drug amd alcohol program.
46 CFR 16.113(a)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2025
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Vessel drill logs were lacking. Conducted satisfactory drill during inspection.
46 CFR 185.524
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 14 May 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (4) Inspection of all railings and bulwarks and their attachment to the hull structure. The vessel was found with a crack on the insert on one of the stanchions located on the starboard quarter bow, inside the vessel. Vessel must grind back the crack to see if there is any further damage and delamination to the insert, submit proper plans and repairs to the satisfaction of the Marine Inspector.
46CFR176.802(a)(4)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024
Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation, in which case no floating water light is required. (1) Each floating water light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Vessel’s water light for the ring life buoy was found inoperable and meant for life jackets. Replace the water light to the satisfaction of the Marine Inspector.
46CFR180.70(d)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2024
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel was found with a life jacket without the vessel’s name marked on it. Clearly and legibly mark the life jacket with the vessel’s name.
46CFR185.604(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel’s ring life buoy was found without the vessel’s name marked on it. Clearly and legibly mark the vessel’s name on the ring life buoy.
46CFR185.604(b)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 April 2021
Resolved
The items contained in first aid kit shall be listed in table 160.041. Missing ammonia inhalants and aspirin is expired. Provide valid items.
46 CFR 160.041-4
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 April 2021
Resolved
Each ring buoy must be must be marked in clearly legible block capitol letters with the vessels name. Each ring life buoy must be marked with type II retroreflective material approved in accordance with 46 CFR 164.08. Stencil vessel name and place retroreflective material on ring buoy
46 CFR 185.604
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 June 2020
Resolved
Vapor barriers must be provided where flammable and combustible liquids or vapors are present, such as machinery spaces. The engine compartment has a electrical wire penetration that is not vapor tight. Renew the vapor tight boundary for the engine room compartment to the satisfaction of the Marine Inspector.
46CFR177.410(e)
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 June 2020
Resolved
Escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: "EMERGENCY EXIT, KEEP CLEAR." The forward emergency escape hatch is currently labeled, but the label is fading and unreadable. Label the hatch IAW with 46CFR185.606.
46CFR185.606
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2020
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The flexible raw water intake hose servicing the sink did not have any hoseclamps at the through hull valve. Install proper hose clamps at the through hull valve.
46CFR182.100
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 May 2019
Resolved
A vessel on lakes, bays, and sounds or rivers route must carry three hand red flare distress signals approved in accordance with 160.021 in subchapter Q of this chapter and three hand orange smoke distress signals in accordance with 160.037 in subchapter Q of this chapter. Vessel does not have three hand red flare distress signals as required. 46CFR180.68(b) code 60c
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 May 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit did not contain Aspirin or Ammonia inhalants. 46CFR184.710 code 16(c)
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 16 May 2019
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. The employer may establish the EAP as a part of its internal personnel services or the employer may contract with an entity that will provide EAP services to a crewmember. Drug and alcohol program for vessel does not include company policy with EAP. 46CFR16.401 code 16c
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 May 2019
Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be only weathertight: each hatch in a cabin top. Hatch in cabin top is not weathertight; add latching mechanism. 46CFR179.360(a)(2) code 16c
Engineering › Bilge Water Management System › Pump
Issued 8 May 2018
Resolved
Install UL approved bilge pump & provide secondary means of pumping (additional UL approved pump or hand pump @ 5gpm). Any excess bilge pump which is not UL approved must not be placed in automatic operation.
Sail Rigging › Running Rigging › Blocks
Issued 8 May 2018
Resolved
Create a vessel specific rigging maintenance plan IAW NVIC 02-16.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2017
Resolved
Provide up to date first aid kit 46CFR184.710
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 June 2017
Resolved
Service pre-engineered fixed gas fire extinguishing system. 46CFR181.420
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 5 June 2017
Resolved
Label 7 adult PFDs with vessel name. 46CFR185.604
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 10 June 2014
Resolved
Provide DAPI documentation for random testing.
Documentation › Logs/Records › Logbook (official)
Issued 10 June 2014
Resolved
Provide log for life saving and drills.
Sail Rigging › Deck Hardware › Travellers and Blocks
Issued 10 June 2014
Resolved
Provide copy of recent rigging survey.
Construction/Loadline › Structures › End Bulkhead
Issued 10 June 2014
Resolved
Repair hand rail anchor on port side.
Engineering › Fuel Oil Service System › Valve
Issued 10 June 2014
Resolved
Properly label remote fuel valve shutoff.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 June 2014
Resolved
Provide emergency instructions at operating station.
Lifesaving › Hand Flares › Expired
Issued 12 June 2012
Resolved
Provide up to date flares onboard (3 orange smoke, 3 red flare)
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 12 June 2012
Resolved
Properly bond fuel fill line to tank body.
Lifesaving › Lifebuoys › Approval
Issued 12 June 2012
Resolved
Provide 24 inch coast guard approved life ring buoy with waterlight and 60 ft line onboard.
Fire Fighting › Fire Bucket › Quantity
Issued 12 June 2012
Resolved
Provide one additional fire bucket onboard.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 June 2012
Resolved
Seperate chaild and adult size lifejackets.
Documentation › Certificates/Documents › Stability Letter
Issued 24 July 2006
Resolved
Properly post original stability letter IAW 46 CFR 176.306
Documentation › Certificates/Documents › FCC SSL
Issued 24 July 2006
Resolved
Provide current copy of FCC Station License.
Documentation › Certificates/Documents › FCC SSL
Issued 24 July 2006
Resolved
Provide current copy of FCC Safety License.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 24 July 2006
Resolved
Properly label the life jacket storage boxes IAW 46 CFR 180.78.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 July 2006
Resolved
Provide a complete first aid kit with current dates IAW 46 CFR 184.710.
Lifesaving › Lifebuoys › Not on Board
Issued 6 June 2005
Resolved
Provide on board a USCG certified ring life bouy, meeting the requirrements of 46 CFR 180.70.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2005
Resolved
prove proper operation of bilge high water alarm prior to carrying passengers.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 May 2005
Resolved
Properly labe storage area's for adult and child sized life preservers.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 May 2005
Resolved
Provide proof of enrollment of company employee's in drug testing program.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 May 2005
Resolved
Prove operation of bilge alarms.
Documentation › Certificates/Documents › Stability Letter
Issued 6 May 2005
Resolved
Properly post Stability Letter, Certificate of Inspection, Certificate of Documentation, Pollution placard, Emergency broadcast placard.
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 6 May 2005
Resolved
Prove proper operation of fixed gas firefighting system equipment shut downs.
Fire Fighting › Fire Bucket › Quantity
Issued 6 May 2005
Resolved
Provide on board 3 fire buckets in accordance with 46 CFR 181.610.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 6 May 2005
Resolved
Provide on board in accordance with the Certificate of Inspection the required number of portable fire extinguishers.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 May 2005
Resolved
Post life jacket donning placard conspicuously visible to all persons on board.
Navigation › Piloting/Steering › Marine Charts
Issued 6 May 2005
Resolved
Provide on board applicable navigation charts, light list, applicable notices to mariners, and inland navigation rules.
Construction/Loadline
Issued 13 February 1997
Resolved
Provide watertight dead covers for the port and stbd portlights in the lazarette or permanently seal the portlights in the closed position.
Accommodation/Occupational Safety
Issued 13 February 1997
Resolved
Install rigid, fireproof ventilation ducting for the supply and exhaust to the engine room.
Documentation
Issued 13 February 1997
Resolved
Provide proof of Employees' Assistance Program and documentation of the supervisory 60 minute training in accordance with 46CFR16.
Deck/Cargo
Issued 13 February 1997
Resolved
Properly secure the forward retaining pin for the main sail spar(boom).
Deck/Cargo
Issued 13 February 1997
Resolved
Permanently repair the two fractures in the main sail spar (aluminum boom) located 1 foot aft of the retaining pin.
Engineering
Issued 13 February 1997
Resolved
In lieu of automotive hose, install CG approved type flexible fuel hose with double hose clamps at each connection for the main diesel engine fuel supply and return.
Construction/Loadline
Issued 13 February 1997
Resolved
Renew broken retaining dog on the port portlight in the lazarette.
Engineering
Issued 18 September 1996
Resolved
Conduct machinery inspection in Maui to the satisfaction of the attending marine inspector.
Lifesaving
Issued 18 September 1996
Resolved
Conduct underway emergency drills and tests of the sailing gear to the satisfaction of the attending marine inspector.
Documentation
Issued 6 March 1996
Resolved
Provide evidence of compliance with chemical testing regulations.
Lifesaving
Issued 6 March 1996
Resolved
Prove operation of the waterlight for the ring buoy.
Lifesaving
Issued 6 March 1996
Resolved
Renew PFD reflective tape as needed.
Lifesaving
Issued 6 March 1996
Resolved
Prior to carrying passengers for hire, provide 3 additional smoke flares.
Deck/Cargo
Issued 6 March 1996
Resolved
Properly mouse anchor chain.
Documentation
Issued 6 March 1996
Resolved
Provide a copy of subchapter "T".
Lifesaving
Issued 6 March 1996
Resolved
Provide pendants for buoyant apparatus.
Fire Fighting
Issued 6 March 1996
Resolved
Prior to carrying passengers, provide one additional portable extinguisher (B-II).
Documentation
Issued 6 September 1995
Resolved
ON 06SEP95, [name withheld], THE MASTER OF THE P/V SUNTAN SPECIAL, A MANNED OCEANGOING SHIP, MORE THAN 40FT IN LENGTH, ENGAGED IN COMMERCE, AND DOCUMENTED UNDER THE LAWS OF THE UNITED STATES, WAS NOT MAINTAINING ON THE SHIP, A WRITTEN RECORK OF ANY GARBAGE DISCHARGED OR DISPOSAL OPERATIONS.
Documentation
Issued 6 September 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline
Issued 13 July 1995
Resolved
Properly secure loose fixed hand bilge pump.
Fire Fighting
Issued 13 July 1995
Resolved
Service expired portable CO2 fire extinguishers, one B-I and one B-II.
Fire Fighting
Issued 13 July 1995
Resolved
Properly mnount with approved brackets all portable fire extinguishers.
Construction/Loadline
Issued 13 July 1995
Resolved
Install collision bulkhead access panel.
Accommodation/Occupational Safety
Issued 13 July 1995
Resolved
Post MARPOL V placard.
Navigation
Issued 13 July 1995
Resolved
Properly secure VHF-AM antennae cable.
Lifesaving
Issued 13 July 1995
Resolved
Provide CG approved weak link for buoyant apparatus.
Accommodation/Occupational Safety
Issued 13 July 1995
Resolved
Properly secure all loose lifelines, loose gear on main deck, and loose gear in below deck passenger accommodation area.
Accommodation/Occupational Safety
Issued 13 July 1995
Resolved
Properly install MSD system.
Documentation
Issued 13 July 1995
Resolved
Provide documentation for compliance with 50% random drug testing within the past 12 months.
Lifesaving
Issued 13 July 1995
Resolved
Properly renew or repair 9 adult and 2 child PFD's, vessel limited to the carraige of 16 adults and one child until PFD's corrected.
Documentation
Issued 3 September 1993
Resolved
PRODUCE DRUG TESTING PROGRAM IN ACCORDANCE WITH 46 CFR 16.230.
Documentation
Issued 3 September 1993
Resolved
PRODUCE EVIDENCE OF DRUG TESTING FOR 50% OF CREW IN ACCORDANCE WITH 46 CFR 16.230 (E).
Navigation
Issued 3 September 1993
Resolved
REPLACE AS ORIGINAL STEERING GEAR PULLEY TO RUDDER AS PER 46 CFR 182.30-1.
Deck/Cargo
Issued 3 September 1993
Resolved
REPLACE AS ORIGINAL MAIN SHEATH FOR MAIN SAIL.
Deck/Cargo
Issued 3 September 1993
Resolved
REPLACE AS ORIGINAL ROLLER FURLING LINE.
Documentation
Issued 3 September 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline
Issued 16 March 1992
Resolved
PROVIDE CLAMPS ON PIPING FOR ENGINE COOLING WATER DISCHARGE.
Engineering
Issued 16 March 1992
Resolved
PROVIDE A COVER FOR THE ENGINE SHUTDOWN SWITCH.
Construction/Loadline
Issued 16 March 1992
Resolved
PROVIDE PORTABLE HAND HELD BILGE PUMP. MUST BE A MINIMUM CAPACITY OF 5 GALLONS PER MINUTE.
Construction/Loadline
Issued 13 March 1990
Resolved
RENEW ALL SEA VALVES WITH ACCEPTABLE METALLIC VALVES PRIOR TO COMPLETION OF CREDIT DRYDOCK AND / OR CARRIAGE OF PASSENGERS.
Construction/Loadline
Issued 13 March 1990
Resolved
ALL CLOSURE OF THRU HULL OPENINGS TO BE IN ACCORDANCE WITH 46 CFR ON FRP.
Construction/Loadline
Issued 13 March 1990
Resolved
FRP REPAIR OF CABINET BASE DIRECTLY ABOVE AND AFT ( TRAILING EDGE ) OF KEELBOARD PRIOR TO COMPLETION OF CREDIT DRY DOCK.
Construction/Loadline
Issued 13 March 1990
Resolved
RENEW ALL THRU HULL FITTINGS 18" ABOVE AND BELOW WATERLINE OF VESSEL WITH ACCEPTABLE METALLIC FITTINGS.
Unknown
Issued 5 March 1990
Resolved
LABEL ENGINE START/STOP SWITCH (PORT SIDE) AND EMERGENCY FUEL SHUTOFF SOLENOID SWITCHES.
Navigation
Issued 5 March 1990
Resolved
PROVIDE THREE ADDITIONAL RED FLARES.
Lifesaving
Issued 5 March 1990
Resolved
RENEW RETRO-REFLECTIVE TAPE ON LIFE PRESERVERS AS NEEDED.
Unknown
Issued 5 March 1990
Resolved
PROVIDE AN OPERABLE FLASHLIGHT FOR EMERGENCY LIGHHTING.
Unknown
Issued 5 March 1990
Resolved
PROVIDE PROPER EMERGENCY CHECK-OFF LIST.
Lifesaving
Issued 8 March 1989
Resolved
REPAIR PEELING PORTIONS OF BUOYANT APPARATUS.
Navigation
Issued 8 March 1989
Resolved
MAKE ALL NAVIGATION LIGHTS OPERABLE PRIOR TO OPERATING AT NIGHT OR DURING PERIODS OF REDUCED VISIBLITY.
Documentation
Issued 8 March 1989
Resolved
CHANGE HAILING PORT MARKING ON STERN OF VESSEL TO A PORT WITHIN THE HONOLULU ZONE.
Fire Fighting
Issued 8 March 1989
Resolved
PROVIDE ONBOARD, ONE ADDITIONAL B:II PORTABLE FIRE EXTINGUISHER TO ACHIEVE A TOTAL OF TWO B:II'S AND ONE B:I.
Fire Fighting
Issued 7 December 1987
Resolved
PRIOR TO OPERATION, PROVIDE ONE ADDITIONAL B-II AND TWO B-I FIRE EXTIN- GUISHERS.
Fire Fighting
Issued 7 December 1987
Resolved
RECHARGE ONE B-II FIRE EXTINGUISHER.
Unknown
Issued 29 April 1986
Resolved
REPAIR SMALL HOLES IN RING BUOY.
Unknown
Issued 29 April 1986
Resolved
REPAIR SMALL HOLE IN BUOYANT APPARATUS.
Unknown
Issued 29 April 1986
Resolved
REPLACE BATTERIES FOR EXTYRA STROBE LIGHT ON BUOYANT APPARANTUS.
Unknown
Issued 29 April 1986
Resolved
PROVIDE 3 ADDITIONAL ORANGE SMOKE SIGNALS.
Unknown
Issued 29 April 1986
Resolved
OBTAIN FCC DOCUMENTS FOR RADIO INSTALLATION AND RADIO OPERATIONS PERMIT.
Lifesaving
Issued 18 March 1985
Resolved
LABEL BUOYANT APPARATUS AND PROVIDE FLOAT FREE LINK.
Electrical
Issued 18 March 1985
Resolved
INSTALL AUTOMATIC ENERGIZED EMERGENCY LIGHTING FOR ACCOMMODATIONS BELOW DECK.
Lifesaving
Issued 18 March 1985
Resolved
PROVIDE 6 ADULT APPROVED TYPE I PFD'S.
Navigation
Issued 18 March 1985
Resolved
PROVIDE ONE CLASS A CG APPROVED EPIRB.
Construction/Loadline
Issued 26 February 1985
Resolved
PROVIDE DOCUMENTED REPORTS, PICTURES, CORE SAMPLES, SURVEYOR'S REPORT, MANUFACTURER'S REPORT AND SPECS FOR REPAIR TO DAMAGE TO PORT SIDE.
Casualty record · 2
21 August 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3851854
22 July 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5963501
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.