TAHOE CRUZ

TAHOE CRUZ is a 1982 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in May 2025, along with 20 deficiencies and 2 casualty investigations between 2010 and 2016.

Records from 2010 to 2025. Most recent: inspection, 14 May 2025.

Built
1982
Last inspected
14 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WCB9227
Flag
UNITED STATES
Maury page id
psix-54000

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)48.5 ft × 12.0 ft × 5.2 ft
Registered tonnagegross 16 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBILL LEE YACHTS INC · SOQUEL, CA, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portTAHOE CITY, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 16

14 May 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8118784
26 April 2025 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8126334
14 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7920758
17 May 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681332
4 May 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7452363
28 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7189014
26 April 2021 Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7182343
9 December 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7109068
8 October 2020 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070341
10 June 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949467
30 April 2020 Drydock Extension · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6946535
16 May 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681525
8 May 2018 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6410554
5 June 2017 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6163792
22 July 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5963501
4 April 2016 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5863192

Deficiency record · 20

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2025 Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs... The vessel lacked documentation for drug amd alcohol program. 46 CFR 16.113(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2025
Resolved 22 May 2025
Resolution: Accepted paperwork for DAPI program.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2025 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Vessel drill logs were lacking. Conducted satisfactory drill during inspection. 46 CFR 185.524
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 15 May 2025
Resolution: Corrected on spot.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 14 May 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (4) Inspection of all railings and bulwarks and their attachment to the hull structure. The vessel was found with a crack on the insert on one of the stanchions located on the starboard quarter bow, inside the vessel. Vessel must grind back the crack to see if there is any further damage and delamination to the insert, submit proper plans and repairs to the satisfaction of the Marine Inspector. 46CFR176.802(a)(4)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 1 July 2024
Resolution: Vessel sumbitted photos of the repair all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024 Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation, in which case no floating water light is required. (1) Each floating water light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Vessel’s water light for the ring life buoy was found inoperable and meant for life jackets. Replace the water light to the satisfaction of the Marine Inspector. 46CFR180.70(d)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 28 September 2024
Resolution: Photo has been received of corrected light, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2024 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel was found with a life jacket without the vessel’s name marked on it. Clearly and legibly mark the life jacket with the vessel’s name. 46CFR185.604(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 1 July 2024
Resolution: Operator submitted photo of proper markings installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel’s ring life buoy was found without the vessel’s name marked on it. Clearly and legibly mark the vessel’s name on the ring life buoy. 46CFR185.604(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 1 July 2024
Resolution: Operator submitted photo of properly marked ring life buoy.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 April 2021 Resolved
The items contained in first aid kit shall be listed in table 160.041. Missing ammonia inhalants and aspirin is expired. Provide valid items. 46 CFR 160.041-4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 14 May 2021
Resolution: Operator sent pictures of newly purchased aspirin and ammonia inhalants.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 April 2021 Resolved
Each ring buoy must be must be marked in clearly legible block capitol letters with the vessels name. Each ring life buoy must be marked with type II retroreflective material approved in accordance with 46 CFR 164.08. Stencil vessel name and place retroreflective material on ring buoy 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 14 May 2021
Resolution: Operator sent picture of life ring buoy with retroreflective tape and vessel name stenciled.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 June 2020 Resolved
Vapor barriers must be provided where flammable and combustible liquids or vapors are present, such as machinery spaces. The engine compartment has a electrical wire penetration that is not vapor tight. Renew the vapor tight boundary for the engine room compartment to the satisfaction of the Marine Inspector. 46CFR177.410(e)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 30 June 2020
Resolution: Received picture of vapor tight boundary repaired.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 June 2020 Resolved
Escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: "EMERGENCY EXIT, KEEP CLEAR." The forward emergency escape hatch is currently labeled, but the label is fading and unreadable. Label the hatch IAW with 46CFR185.606. 46CFR185.606
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 30 June 2020
Resolution: Received picture of new label affixed to emergency escape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2020 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The flexible raw water intake hose servicing the sink did not have any hoseclamps at the through hull valve. Install proper hose clamps at the through hull valve. 46CFR182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 30 June 2020
Resolution: Received picture of raw water intake double hose clamped.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 May 2019 Resolved
A vessel on lakes, bays, and sounds or rivers route must carry three hand red flare distress signals approved in accordance with 160.021 in subchapter Q of this chapter and three hand orange smoke distress signals in accordance with 160.037 in subchapter Q of this chapter. Vessel does not have three hand red flare distress signals as required. 46CFR180.68(b) code 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 16 May 2019
Resolved 20 June 2019
Resolution: Received photo documentation of new flares.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 May 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit did not contain Aspirin or Ammonia inhalants. 46CFR184.710 code 16(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 20 June 2019
Resolution: Received photo documentation of new aspirin & ammonia inhalants.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 16 May 2019 Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. The employer may establish the EAP as a part of its internal personnel services or the employer may contract with an entity that will provide EAP services to a crewmember. Drug and alcohol program for vessel does not include company policy with EAP. 46CFR16.401 code 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 20 June 2019
Resolution: Received photo documentation of EAP.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 May 2019 Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be only weathertight: each hatch in a cabin top. Hatch in cabin top is not weathertight; add latching mechanism. 46CFR179.360(a)(2) code 16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 20 June 2019
Resolution: Received photo documentation, hatch has been secured.
Engineering › Bilge Water Management System › Pump
Issued 8 May 2018 Resolved
Install UL approved bilge pump & provide secondary means of pumping (additional UL approved pump or hand pump @ 5gpm). Any excess bilge pump which is not UL approved must not be placed in automatic operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 21 August 2018
Resolution: Witnessed sat operational test of new UL approved pump installation.
Sail Rigging › Running Rigging › Blocks
Issued 8 May 2018 Resolved
Create a vessel specific rigging maintenance plan IAW NVIC 02-16.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 29 May 2018
Resolution: Maintenance Plan created, added to vsl electronic file and documents tab.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2017 Resolved
Provide up to date first aid kit 46CFR184.710
Condition: Improper/Lack of Maintenance
Due 5 June 2017
Resolved 29 June 2017
Resolution: Observed up to date first aid kit.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 June 2017 Resolved
Service pre-engineered fixed gas fire extinguishing system. 46CFR181.420
Condition: Improper/Lack of Maintenance
Due 5 June 2017
Resolved 12 June 2017
Resolution: Observed up to date servicing of pre-engineered fixed gas fire extinguishing system.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 5 June 2017 Resolved
Label 7 adult PFDs with vessel name. 46CFR185.604
Condition: Placed in Improper Service
Due 5 June 2017
Resolved 12 June 2017
Resolution: All adult PFDs properly labeled with vessel name.

Casualty record · 2

21 August 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3851854
22 July 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5963501
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.