This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it292 - Regulatory (Subpart C or D), Gross Ton 216 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 20 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 20
30 March 2007PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2881084
29 April 2000Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 277425
12 July 1999Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 430572
30 April 1991Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938955
27 April 1990COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 918553
8 September 1989Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931016
17 May 1989Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900986
13 April 1989Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 887702
11 September 1988Drydock Extension · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 887619
7 June 1988Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1200558
3 May 1988COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1194349
3 May 1988MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1194355
22 September 1987Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318571
24 August 1987Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339238
10 July 1987Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322538
16 April 1987Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010851
15 September 1986Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005029
15 May 1986COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998574
6 November 1985Persons In Addition to Crew
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1299196
23 June 1984Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1284907
oil record book has not been signed by the master._x001C_ ---Marpol 73/78, annex I/20---
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Navigation
Issued 12 July 1999Resolved
CURRENT CHARTS NOT CORRECTED OR UPDATED._x001C_ ---33 CFR 164.33(a)(ii)---
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Deck/Cargo
Issued 12 July 1999Resolved
2 soft patches on the cooling water pipe for the winches._x001C_
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Electrical
Issued 12 July 1999Resolved
cover on an electrical connection box between the steering gear pumps is mising. _x001C_ ---SOLAS 74(unamended)II-1/27(a)---_x001C_ ---SOLAS 74(amended) II-1/45.1---_x001C_
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Accommodation/Occupational Safety
Issued 12 July 1999Resolved
overboard discharge valve for the MSD was opened in port._x001C_ ---33 CFR 159.7(b)---
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Lifesaving
Issued 3 May 1988Resolved
REPLACE EXISTING NON-APPROVED RING BUOYS WITH COAST GUARD APPROVED TYPE.
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988
Deck/Cargo
Issued 3 May 1988Resolved
REPLACE EXISTING SAFETY RELIEF DEVICE ON TOWING WINCH AIR RECEIVER WITH ASME APPROVED DEVICE.
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988
Deck/Cargo
Issued 3 May 1988Resolved
MAKE AIR RECEIVER LOCATED IN BOW THRUSTER ROOM READY FOR PROPER VISUAL INSPECTION OR HYDROSTATIC TEST AND CONDUCT THE SAME. UNTIL THIS REQUIREMENTIS SATISFIED, WORKING PRESSURE AND SAFETY SETTING ARE LIMITED TO 40 PSI. MUST BE COMPLETED PRIOR TO NEXT DD.
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988
Engineering
Issued 3 May 1988Resolved
DEMONSTRATE PROPER OPERATION OF THE PORTSIDE MAIN ENGINE HIGH TEMPERATURE SENSOR.
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988
Engineering
Issued 3 May 1988Resolved
INSTALL SAFETY RELIEF DEVICES ON PORT & STBD CONTROL AIR PRESSURE VSL IN ERUNTIL REQ IS COMPLETE THE IN-LINE BOOK PRESSURE VALVES BETWEEN THESE AIR RECEIVERS & MDE STARTING AIR RECEIVERS MUST BE REMOVED; EXISTING SAFETY ON THE STARTING AIR RECEIVERS MUST BE SET AT NO GREATER THAN 150 PSI.
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988
Fire Fighting
Issued 16 April 1987Resolved
REPLACE PRESENT NON APPROVED CO2 BOTTLE FOR THE PAINT LOCKER WITH A BOTTLE MEETING U.S. DOT REQUIREMENTS.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Electrical
Issued 16 April 1987Resolved
REPLACE THE LIGHT IN THE PAINT LOCKER WITH A UL OR FM LISTED LIGHT SUITABLE FOR CLASS I, DIVISION 1, GROUP D ATMOSPHERE.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Engineering
Issued 16 April 1987Resolved
PROVIDE A SUCTION LINE FOR WASTE OIL FROM THE E/R BILGE TO THE MAIN DECK.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Deck/Cargo
Issued 15 September 1986Resolved
PRIOR TO OPERATION OF DRY BULK TANKS, INSTALL AND PROVE PROPER OPERATION OFRELIEF VALVES (ASME APPROVED) WITH A SET PRESSURE OF 40 PSI ON EACH BULK TANK.
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Engineering
Issued 23 June 1984Resolved
PROVIDE NEW HOT WATER SUPPLY VESSEL WITH PRESSURE RELIEF DEVICE AS PER 46 CFR 54.15-5.
Condition: Unknown
Due 23 June 1984
Resolved 23 June 1984
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.