← All vessels
GSF MAIN PASS I
GSF MAIN PASS I is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 92 inspections since 1982, most recently in January 2007, along with 117 deficiencies and 1 casualty investigation in 2003.
Records from 1982 to 2007. Most recent: inspection, 22 January 2007.
- Built
- 1982
- Last inspected
- 22 January 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 117 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2003
Identity
647709
8751485 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
YJUF2
54018
Flag
VANUATU
—
Maury page id
psix-54018
Inspections, by type
…with no type recorded18
Years with a record
24 calendar years (1982–2007)
The 92 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it4580 - Regulatory (Subpart C or D), Gross Ton
4976 - Convention (Subpart B), Gross Ton
4580 - Regulatory (Subpart C or D), Net Ton
1244 - Convention (Subpart B), Net Ton
4976 - Convention (Subpart B), Gross Ton
4580 - Regulatory (Subpart C or D), Net Ton
1244 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
KVXWMMSI not assigned · expired · compulsorily equipped · granted 28 May 1997, cancelled 20 October 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 92
22 January 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2859953
24 October 2005
COC-MODU Annual
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2521831
13 August 2004
COC-MODU Renew
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2164939
22 March 2004
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2029123
20 October 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1947180
18 June 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1822250
27 April 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1788338
24 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1762293
25 June 2002
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1655944
22 April 2002
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1607512
11 April 2002
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1603533
19 April 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415589
19 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1056639
18 January 2001
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463633
6 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1056813
2 October 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 128058
15 August 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361674
1 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1052469
20 March 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464266
6 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815790
25 October 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1127279
22 July 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1103710
22 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192227
14 June 1999
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 810388
27 April 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444135
14 April 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 788285
1 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797420
29 September 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 801997
22 June 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1126092
23 March 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1122299
20 March 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408072
18 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1113136
15 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774276
21 November 1997
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1408035
22 September 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779312
17 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111024
10 June 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 774862
21 April 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1105846
10 April 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421300
27 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093541
3 June 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1090566
9 April 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392443
8 March 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 885185
8 February 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454295
21 September 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437015
19 June 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 47442
24 May 1995
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 872526
12 April 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1155486
11 April 1995
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1414427
15 December 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843355
8 November 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171477
1 August 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177339
5 July 1994
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 870315
30 June 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175619
13 April 1994
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1444857
5 April 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 856940
31 January 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161980
8 November 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1134731
23 September 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1141136
8 August 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 70451
8 June 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 831785
5 May 1993
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1359659
10 April 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1142949
22 March 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1147135
12 March 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842141
21 January 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 832849
21 December 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829357
9 September 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1262773
8 April 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955237
3 April 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258832
8 May 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249230
2 April 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 923665
5 August 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 923606
18 July 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226977
13 June 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914322
8 May 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 906938
25 April 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230616
19 April 1990
Drydock Extension · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236623
15 June 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 924085
9 August 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1343001
12 June 1988
Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891401
17 April 1988
COI Inspection · Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342652
2 December 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335492
27 March 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327026
7 December 1986
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332776
29 May 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986287
18 May 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986926
22 November 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294348
22 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979463
28 March 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1286513
23 May 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1284895
28 May 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1271363
Deficiency record · 117
Lifesaving › Launching Appliances › Release Mechanism
Issued 24 October 2005
Resolved
Provide proof of life boat release gear on load test prior to 24 NOV 05
Fire Fighting › Fixed Fire Detection System
Issued 18 June 2003
Resolved
Repair / replace and prove operation of fire detection system. Alarm center currently shows 5 zones in FAULT Mode, 4 zones in ALARM Mode and Battery Trouble. LEGACY COMPONENT DESC: Control Panel
Fire Fighting › Firemans Outfit
Issued 22 April 2002
Resolved
PROVIDE TWO SPARE BOTTLES FOR FIREMANS OUTFITS. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Documentation › Logs/Records
Issued 22 April 2002
Resolved
DESIGNATE "SECOND IN COMMAND" FOR EACH LIFEBOAT. UPDATE MUSTER LIST. LEGACY COMPONENT DESC: Logbook (official)
Operations/Management › Equipment Service/Testing
Issued 22 April 2002
Resolved
PROVE PURGE ALARM ON PETRON BOX AND DRILLERS CONSOLE.
Lifesaving › Launching Appliances
Issued 22 April 2002
Resolved
PROVE PROPER OPERATION OF LIMIT SWITCHES AND CONTROLLER ON #2 LIFEBOAT.
Engineering › Pressure Vessel
Issued 22 April 2002
Resolved
MAKE ALL AIR RECEIVERS AND PRESSURE VESSELS READY FOR 5 YEAR INTERNAL INSPECTION BY THE ATTENDING US COAST GUARD MARINE INSPECTOR. LEGACY COMPONENT DESC: Relief Valve
Engineering › Generator (propulsion/auxiliary-electric)
Issued 22 April 2002
Resolved
PROVE PROPER OPERATION OF AUTO START/AUTO TRANSFER FOR THE EMERGENCY GENERATOR. LEGACY COMPONENT DESC: Auto Transformer Circuitry
Engineering › Generator (propulsion/auxiliary-electric)
Issued 22 April 2002
Resolved
UTILIZE AUTO START ADN AUTO TRANSFER DURING MONTHLY TEST OF EMERGENCY GENERATOR AND LOG SAME. LEGACY COMPONENT DESC: Auto Transformer Circuitry
Unknown
Issued 19 April 2001
Resolved
RENEW DRILL FLOOR AIR RECEIVER, OR MAKE DATA PLATE LEDGIBLE WITHOUT ALTERATIONS, OR HAVE NEW DATA PLATE PROVIDED / ATTACHED WITH / DURING INSPECTION BY ASME CERTIFIED SHOP. NEW INSTALLATION MUST BE INSPECTED AND STAMPED BY A COAST GUARD MARINE INSPECTOR.
Unknown
Issued 19 April 2001
Resolved
RENEW THE FOLLOWING ITEMS ON THE STARBOARD CRANE: ALL ENGINE FUEL AND OIL FLEX LINES, FORWARD LOWER WINDOW, AND FUEL PRESSURE GAUGE ON ENGINE FUEL PRIMER PUMP.
Unknown
Issued 19 April 2001
Resolved
PROVIDE 100 PSI OR LESS SAFETY RELIEF VALVE FOR DOMESTIC HOT WATER HEATERS.
Lifesaving
Issued 19 April 2001
Resolved
REPAIR AFTER STARBOARD ENTRY STEP ON #2 LIOFEBOAT.
Lifesaving
Issued 19 April 2001
Resolved
HOOK UP AND TEST GENERAL ALARM BELL IN SMOKER'S SHACK.
Lifesaving
Issued 19 April 2001
Resolved
PROVIDE ONE ADDITIONAL MEANS OF ESCAPE FROM MAIN DECK TO WATER'S EDGE.
Unknown
Issued 19 April 2001
Resolved
ROUTE ALL ASSOCIATED OIL BASED HOSES IN A MANNER THAT DOES NOT INTERFERE WITH OPERATION OF OR PASSES THROUGH WATER OR GAS TIGHT DOORS OR BREAKS THE GAS TIGHT INTEGRITY OF THE MUD PIT ROOM.
Construction/Loadline
Issued 18 January 2001
Resolved
OPEN DRILLWATER TANK 4-P AND MAKE READY FOR USCG INSPECTION IN RELATION TO SIDESHELL DAMAGE. ANY REPAIRS SHALL BE MADE TO THE SATISFACTION OF [name withheld].
Construction/Loadline
Issued 18 January 2001
Resolved
MAKE ACCESS HOLE THROUGH SWASH BULKHEAD OR INSTALL LADDER ON EACH SIDE OF SWASH BULKHEAD IN DRILLWATER TANK 4-P.
Deck/Cargo
Issued 18 January 2001
Resolved
REPAIR PORT CRANE TO SATISFACTION OF ABS CLASS SURVEYOR AND PROOF TEST. SUBMIT ABS REPORT TO [name withheld].
Lifesaving
Issued 18 January 2001
Resolved
RENEW LIFERAFT NO.4 AND CONDUCT 1.1 LOAD TEST ON PORT LIFERAFT DAVIT IN PRESENCE OF USCG MARINE INSPECTOR. ANY REPAIRS SHALL BE MADE TO SATISFACTION OF [name withheld].
Construction/Loadline
Issued 15 August 2000
Resolved
REPAIR LANDING AT STARBOARD LIFERAFT STATION WHERE CRACKED.
Construction/Loadline
Issued 15 August 2000
Resolved
CROP AND RENEW BULKHEAD STIFFENERS IN PRELOAD TANK #7 STARBOARD THAT ARE WASTED BEYOND 25%. ALSO RENEW / REPAIR THE ONE BAD LADDER.
Construction/Loadline
Issued 15 August 2000
Resolved
CROP AND RENEW WASTED STIFFENERS AND GUSSETS THROUGHOUT PRELOAD TANK #6 STARBOARD THAT ARE WASTED BEYOND 25%.
Construction/Loadline
Issued 15 August 2000
Resolved
CROP AND RENEW THE FOLLOWING IN #6 PORT PRELOAD TANK: FORWARD TRANSVERSE BULKHEAD'S TOP STRINGER WHERE WASTED.
Construction/Loadline
Issued 15 August 2000
Resolved
CROP AND RENEW THE FOLLOWING IN #7 PORT PRELOAD TANK: INBOARD BAYS FRAME SPACES 19-20, ALL OVERHEAD ANGLES AND FORWARD/AFT TRANSVERSE BULKHEAD STIFFENERS WHEREWASTED.
Lifesaving
Issued 15 August 2000
Resolved
CROP AND RENEW WASTED AND HOLED HANDRAILS THROUGHOUT RIG AS NECESSARY.
Construction/Loadline
Issued 15 August 2000
Resolved
COMPLETE UNDERWATER SURVEY OF LEG TO CAN CONNECTIONS TO SATISFACTION OF ATTENDING CLASS SURVEYOR OR MARINE INSPECTOR. SUBMIT DIVE REPORT AND VIDEO TO [name withheld].
Construction/Loadline
Issued 15 August 2000
Resolved
CROP AND RENEW THE FOLLOWING IN #2 PORT PRELOAD TANK: INBOARD AFT BAY BULKHEAD (FRAME 8) 4' X 6' INSERT ALONG WITH VERTICAL STIFFENERS AND SUPPORTING BRACKETS WHERE WASTED. REPAIRS TO BE MADE TO ATTENDING MARINE INSPECTOR OR CLASS SURVEYOR'S SATISFACTION.
Unknown
Issued 27 April 1999
Resolved
CONDUCT AND LOG SATISFACTORY TEST OF THE EMERGENCY TOTAL RIG SHUT-DOWN FROMALL STATIONS.
Unknown
Issued 27 April 1999
Resolved
REPLACE FUEL SUPPLY AND RETURN LINES ON NIS GENERATOR, NO SECTION OF APPROVED TYPE FLEX LINE MAY EXCEED 30 INCHES IN LENGTH.
Lifesaving
Issued 27 April 1999
Resolved
CONDUCT HYDROSTATIC TEST ON BREATHING AIR BOTTLES FOR BOTH LIFEBOATS.
Unknown
Issued 27 April 1999
Resolved
REPLACE SAFETY RELIEF VALVE ON AIR RECEIVER THAT SERVICES DRILL FLOOR. CONDUCT 1.5 HYDROSTATIC TEST, UT OR RENEW SAME RECEIVER TO THE SATISFACTIONOF ATTENDING CG MARINE INSPECTOR.
Unknown
Issued 27 April 1999
Resolved
REPAIR EMERGENCY VENTILATION SHUT-DOWN FOR VENTILATION IN MACHINERY SPACE.
Unknown
Issued 20 March 1998
Resolved
SUBMIT UPDATED FIRE CONTROL AND SAFETY EQUIPMENT PLAN AND HAZARDOUS LOCATION PLAN TO COGNIZANT OCMI FOR APPROVAL.
Lifesaving
Issued 20 March 1998
Resolved
CROP AND RENEW WASTED HANDRAILS THROUGHOUT RIG AS NECESSARY.
Lifesaving
Issued 20 March 1998
Resolved
RENEW LIFE RINGS AS NECESSARY. ENSURE EACH IS PROPERLY MARKED AND EQUIPPED WITH RETROREFLECTIVE TAPE. ENSURE EACH LIFE RING THAT IS EQUIPPED WITH SMOKE IS ALSO EQUIPPED WITH A WATERLIGHT. ENSURE THAT EACH WATERLIGHT OPERATES CORRECTLY AND HAS A PAINT FREE LENS.
Unknown
Issued 20 March 1998
Resolved
REPLACE NON-METALLIC EXPANSION JOINTS THAT ARE MORE THAN 10 YEARS OLD ON DRILL WATER PUMPS, FIRE PUMPS, AND GENERATORS.
Lifesaving
Issued 20 March 1998
Resolved
PROVIDE 4th ROCKET AND LINE TO SATISFY LINE THROWING APPLIANCE REQUIREMENT.
Lifesaving
Issued 20 March 1998
Resolved
REPAIR DAMAGED EXTERIOR COATING ON UPPER HULL OF BOTH LIFE BOATS. PROPERLY WRAP LIFE BOAT CABLES TO PREVENT CHAFFING ON STRUCTURAL MEMBERS. PLACE RETROREFLECTIVE TAPE ON LIFE BOAT NO 1.
Fire Fighting
Issued 20 March 1998
Resolved
REPAIR PORTABLE, SEMI-PORTABLE AND FIXED FIREFIGHTING SYSTEMS IN ACCORDANCEWITH GULF WIDE SAFETY REPORT, DATED 06-07MAR98. PLACE WARNING SIGNS ON EACHACCESS PROTECTED BY A FIXED FIREFIGHTING SYSTEM.
Lifesaving
Issued 20 March 1998
Resolved
OPERATIONALLY TEST RELEASE GEAR ON BOTH LIFEBOATS UNDER A LOAD OF 1.1_x001C_ TIMES THE TOTAL MASS OF THE LIFEBOAT WITH ITS FULL COMPLEMENT OF PERSONS AND EQUIPMENT.
Unknown
Issued 20 March 1998
Resolved
REMOVE FIBERGLASS GRATING FROM ENGINE ROOM OR OBTAIN APPROVAL FOR INSTALLATION FROM MARINE SAFETY CENTER.
Fire Fighting
Issued 20 March 1998
Resolved
CROP AND RENEW HOLED FIRE MAIN PIPING AT FIRE PUMP NO. 2 AND WASTED FIRE STATION PIPING ON DRILL FLOOR.
Electrical
Issued 20 March 1998
Resolved
REPAIR AND CONDUCT SATISFACTORY TEST OF EMERGENCY TOTAL RIG SHUT-DOWN.
Lifesaving
Issued 20 March 1998
Resolved
PLACE 4th LIFE RAFT ON BOARD (STATION #2); PROPERLY MARK LIFE RAFT_x001C_ CANISTERS WITH RAFT STATION NUMBER AND CAPACITY.
Lifesaving
Issued 20 March 1998
Resolved
IMPLEMENT POLICY TO INCLUDE THE OPERATION OF LIFERAFT DAVITS AT EACH_x001C_ DRILL.
Unknown
Issued 20 March 1998
Resolved
REPAIR OIL LEAK ON BULK AIR COMPRESSOR.
Unknown
Issued 20 March 1998
Resolved
REPLACE DRY ROTTED FUEL HOSE AT EMERGENCY GENERATOR STATION.
Electrical
Issued 20 March 1998
Resolved
ADJUST / SEAL MUD PIT DOOR AND SEAL ALL MUD PIT BULKHEAD PENETRATIONS.
Unknown
Issued 20 March 1998
Resolved
PLACE LIFTING HANDLES ON COMPRESSOR RELIEF VALVES, AS NECESSARY.
Electrical
Issued 20 March 1998
Resolved
CONDUCT AND LOG SEMI-ANNUAL TWO HOUR EMERGENCY BATTERY LOAD TEST IN ACCORDANCE WITH 46CFR109.211.
Electrical
Issued 20 March 1998
Resolved
INSTALL BATTERY POWERED EMERGENCY LIGHTING FOR STAIRTOWER BETWEEN 3rd DECK AND CONTROL HOUSE.
Lifesaving
Issued 20 March 1998
Resolved
REPLACE 27 LIFE PRESERVERS, ENSURE EACH IS PROPERLY MARKED WITH RIG'S NAME,RETROREFLECTIVE TAPE, AND EQUIPPED WITH WHISTLE AND LIGHT. ENSURE THAT LIFEPRESERVERS AND WORK VEST ARE STOWED IN SEPARATE; PROPERLY MARKED CONTAINERS.
Unknown
Issued 20 March 1998
Resolved
REPAIR MARINE SANITATION DEVICE PC BOARD / POWER MODULE.
Unknown
Issued 20 March 1998
Resolved
REPLACE STERN LIGHT LENS PRIOR TO RIG MOVE.
Unknown
Issued 20 March 1998
Resolved
CROP AND RENEW, AS ORIGINAL, WASTED OVERHEAD STIFFENERS IN SHAKER AREA.
Unknown
Issued 20 March 1998
Resolved
REPLACE MISSING DOGS ON VENT CLOSURES THROUGHOUT RIG AS NECESSARY.
Unknown
Issued 20 March 1998
Resolved
ADJUST WATERTIGHT DOORS AND REPLACE DRY ROTTED GASKETS PRIOR TO RIG MOVE.
Construction/Loadline
Issued 21 November 1997
Resolved
REPAIR ALL OUTSTANDING RECOMMENDATIONS NOTED IN ABS REPORT MC 7205.
Construction/Loadline
Issued 21 November 1997
Resolved
PROVIDE COPY OF ABS REPORT FOR UWILD SURVEY AND COPIES OF DIVERS VIDEO TO CG FOR REVIEW.
Lifesaving
Issued 10 April 1997
Resolved
PROVIDE PROPER AMOUNT OF SIGNAL MIRRORS (2) FOR EACH LIFEBOAT.
Deck/Cargo
Issued 10 April 1997
Resolved
PROVIDE FUEL OIL TRANSFER HOSE THAT IS WITHIN CURRENT HYDRO DATE. ENSURE HOSE IS MARKED IAW 33CFR155.
Fire Fighting
Issued 10 April 1997
Resolved
REPLACE FIRE NOZZLE CHAINS THROUGHOUT AS NECESSARY.
Lifesaving
Issued 10 April 1997
Resolved
MAKE AIR RECEIVER THAT SERVICES DRILL FLOOR AVAILABLE FOR INTERNAL EXAM ANDTESTING OF THE SAFETY RELIEF VALVE.
Lifesaving
Issued 10 April 1997
Resolved
COMPLY WITH THE REVISIONS TO 46CFR109.
Fire Fighting
Issued 10 April 1997
Resolved
CROP AND RENEW WASTED SECTIONS OF FIREMAIN PIPING AT HOSE STATIONS #8, #11 AND IN PUMP ROOM.
Navigation
Issued 10 April 1997
Resolved
OBTAIN, INSTALL AND ENSURE PROPER OPERATION OF ALL NAVIGATION LIGHTS PRIOR TO NEXT NIGHT TIME RIG MOVE.
Unknown
Issued 10 April 1997
Resolved
COMPLETE WORKLIST ISSUED BY ABS ON 10APR97.
Fire Fighting
Issued 10 April 1997
Resolved
OBTAIN AND INSTALL CLOSURE DEVICES FOR ALL STRUCTURAL FIRE PROTECTION DOORS.
Lifesaving
Issued 10 April 1997
Resolved
RENEW WASTED DECK PLATES IN PIT ROOM AS NECESSARY.
Lifesaving
Issued 9 April 1996
Resolved
RUN BOTH LIFEBOATS IN THE WATER AND TEST SPRINKLER SYSTEMS.
Lifesaving
Issued 9 April 1996
Resolved
MAKE ADJUSTMENTS TO BRAKE RELEASES ON BOTH DAVIT LAUNCHED LIFERAFT SYSTEMS AND TEST IN PRESENCE OF USCG MARINE INSPECTOR.
Lifesaving
Issued 9 April 1996
Resolved
REPLACE CABLES ON BOTH LIFEBOATS WITH PROPER LENGTH CABLES AND WEIGHT TEST BOTH LIFEBOATS.
Construction/Loadline
Issued 8 February 1996
Resolved
Complete leg-to-can connection NDT portion of SEILODD on stbd leg and submit copy of video tape, ABS surveyor's report, and dive company's reportto [name withheld].
Construction/Loadline
Issued 21 September 1995
Resolved
PROVIDE MASTER MUD PIT DUMP VALVE FOR INSPECTION.
Construction/Loadline
Issued 21 September 1995
Resolved
PERFORM NDT INSPECTION OF CRITICAL AREA LEG TO CAN CONNECTIONS DURING NEXT RIG MOVE.
Lifesaving
Issued 11 April 1995
Resolved
REPLACE TEN LIFE PRESERVERS AND ASSOCIATED EQUIPMENT.
Fire Fighting
Issued 11 April 1995
Resolved
REPLACE WATER APPLICATOR NOZZLES WITH USCG APPROVED UNITS TO FIT FIRE HOSE NOZZLES AT FIRE STATIONS #16, 18, 20, AND 21.
Electrical
Issued 11 April 1995
Resolved
PROVE PROPER START UP AND ON LINE OPERATION OF THE EMERGENCY DIESEL GENERATOR.
Fire Fighting
Issued 11 April 1995
Resolved
RAISE HALON BOTTLE FOR RADIO ROOM ABOVE DECK LEVEL.
Fire Fighting
Issued 11 April 1995
Resolved
REPLACE FIREMAN OUTFIT FACE PIECES IN LOCKERS ON TOP AND MAIN DECKS.
Lifesaving
Issued 11 April 1995
Resolved
SUPPLY BOTH LIFE CAPSULES WITH REQUIRED NUMBER OF SIGNALING DEVICES WITH VALID EXPIRATION DATES.
Fire Fighting
Issued 13 April 1994
Resolved
PROVIDE INSTRUCTIONS FOR FIXED FIRE FIGHTING SYSTEM FOR PAINT LOCKER.
Electrical
Issued 13 April 1994
Resolved
PROVE PROPER OPERATION OF #1 GENERATOR ALARMS AND SHUTDOWNS_x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 13 April 1994
Resolved
MAKE READY FOR INSPECTION ALL DRY BULK TANKS AND BOTH DRILL FLOOR AIR RECIEVERS AND TEST RELIEF VALVES FOR THE SAME.
Fire Fighting
Issued 13 April 1994
Resolved
CONDUCT FIRE DRILL IN THE PRESENCE OF COAST GUARD MARINE INSPECTOR
Fire Fighting
Issued 31 January 1994
Resolved
PROVIDE EVIDENCE FROM A USCG RECOGNIZED TESTING LAB THAT PROVES NON-COAST GUARD APPROVED B-15 BULKHEADS IN QUARTERS MEET REQUIREMENTS OF 46CFR164.008OR REPLACE B-15 BULKHEADS WITH CG APPROVED BULKHEADS. (THIS REQT ISSUED AS PER G-MV-3 LTR 16714/164.008/GEN DTD 14JAN94 ON FILE AT NYCMI.)
Documentation
Issued 9 September 1992
Resolved
THE OIM IS TO PROVIDE TO [name withheld] ALL INSPECTION REPORTS TO INCLUDE ABS, NOT SURVEYS, DIVERS SURVEYS (INCLUDING VIDEO RECORDINGS), HULL GAUGINGS, IN FULL PERTAINING TO THE SEILOD CONDUCTED DURING AUGUST AND SEPTEMBER 1992.
Lifesaving
Issued 3 April 1992
Resolved
CONDUCT WEIGHT TEST OF STARBOARD LIFERAFT DAVIT ONCE ITEM 8 HAS BEEN CORRECTED. TEST TO BE DONE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_
Accommodation/Occupational Safety
Issued 3 April 1992
Resolved
REPAIR STAIR TOWER DOORS SO THAT THEY CLOSE PROPERLY._x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 3 April 1992
Resolved
MAKE AVAILABLE FOR HYDRO OR INTERNAL INSPECTION BULK TANKS NUMBER 4,5 AND 6TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 3 April 1992
Resolved
REPLACE ALL EIGHT (8) FOAM FIRE EXTINGUISHERS WITH ONE THAT ARE UL OR USCG APPROVED._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 3 April 1992
Resolved
REPLACE, REPAIR, HYDRO AND/OR REFILL PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH REPORT FROM WOOD GROUP FIRE PROTECTION LTR DTD 30 MARCH 1992._x001C_
Lifesaving
Issued 3 April 1992
Resolved
HAVE LIFERAFT NUMBER 2 REPACKED SO THAT IT MAY BE CONNECTED TO DAVIT._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 3 April 1992
Resolved
REVISE FIRE CONTROL PLAN WITH AS IS CONDITION OF THE RIG. ITEM 4 MUST BE SHOWN ON THIS PLAN. OBTAIN APPROVAL OF REVISED PLAN FROM [name withheld]._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 3 April 1992
Resolved
RECHARGE BOTTLE NUMBER 7 OF THE CO2 FIXED SYSTEM FOR THE MUD PITS._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 3 April 1992
Resolved
PROVIDE TWO CHAIN LADDERS IN ACCORDANCE WITH 46 CFR 108.525.
Lifesaving
Issued 3 April 1992
Resolved
REPLACE OR REPAIR RELEASE HOOK ON STARBOARD LIFERAFT DAVIT._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 8 May 1991
Resolved
HAVE ANNUAL SERVICING OF THE NO.4 (PORT AFT) DAVIT LAUNCHED, INFLATABLE LIFERAFT CONDUCTED BY A USCG APPROVED SERVICING FACILITY BEFORE A USCG MARINE INSPECTOR AND SUBMIT COPY OF SERVICING CERTIFICATE TO [name withheld] (RAFT DUE 4/91).
Lifesaving
Issued 8 May 1991
Resolved
PROVIDE 12 HANDHELD RED FLARES; 12 RED PARACHUTE FLARES; AND 2 ORANGE SMOKESIGNALS (USCG APPROVED AND MANUFACTURED WITHIN THE PAST 3 YEARS) AND RENEW ALL WATER (3 QTS PER PERSON PER BOAT) ABOARD EACH LIFEBOAT CAPSULE, NOTIFY [name withheld] IN WRITING WHEN INSTALLED (WITH SUPPORTING DOCUMENTATION).
Lifesaving
Issued 8 May 1991
Resolved
PROVIDE 12 HAND RED, ROCKET PARACHUTE FLARES FOR VESSEL (USCG APPROVED AND MANUFACTURED WITHIN THE PAST 3 YEARS). NOTIFY [name withheld] IN WRITING WITH SUPPORTING DOCUMENTATION WHEN INSTALLED.
Lifesaving
Issued 19 April 1990
Resolved
TOTAL PERSONS ALLOWED LIMITED TO 75 UNTIL DAVIT LAUNCHED 25-MAN CAPACITY LIFERAFT REMOVED FROM SERVICING IS RETURNED OR REPLACED WITH USCG APPROVED LIFERAFT.
Fire Fighting
Issued 19 April 1990
Resolved
REPLACE OR HAVE SERVICED B-IV SERMI-PORTABLE FIRE EXTINGUISHER ON HELO DECK.
Documentation
Issued 19 April 1990
Resolved
PROVIDE [name withheld] WITH COPY OF CURRENT FOAM ANALYSIS REPORT.
Lifesaving
Issued 19 April 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering
Issued 19 April 1990
Resolved
CONDUCT 1.25 MAWP HYDRO OF AIR RECEIVERS 347008,735736,735738 LOCATED IN CRANES. UNITS MAY BE EXAMINED INTERNALLY IF ACESSIBLE.
Lifesaving
Issued 15 June 1989
Resolved
PROVIDE HYDROSTATIC TESTING OF ALL EIGHT (8) LIFEBOAT OXYGEN BOTTLES AND FORWARD SERVICING CERTIFICATES TO [name withheld].
Fire Fighting
Issued 15 June 1989
Resolved
COMPELTE SERVICING OF PORTABLE FIRE EXTINGUISHERS AS RECOMMENDED BY WOOD GROUP INITIAL REPORT DATED 06 JUNE 1989.
Unknown
Issued 15 June 1989
Resolved
PROVIDE CG WAIVER LETTER FOR ALL NON-D.O.T. HIGH PRESSURE CYLINDERS ON BOARD.
Accommodation/Occupational Safety
Issued 15 June 1989
Resolved
PROVIDE CG WAIVER LETTER OR APPROVAL LETTER OF HELO REFUELING TANK .
Construction/Loadline
Issued 12 June 1988
Resolved
PROVIDE [name withheld] WITH A COPY OF THE VIDEO TAPE (ADAPTED FOR U.S.) AND A COPY OF THE DIVERS REPORT CONCERNING THE UNDERWATER SURVEY CONDUCTED 8 TO13 JUNE 1988.
Unknown
Issued 17 April 1988
Resolved
PRIOR TO MOVING RIG CONDUCT AN UNDERWATER SURVEY & EXAMINATION ON ALL SPUD CANS AND COMPLETE WORK LIST FROM MIONY DATED 17 APRIL 1988. THIS REQ. WAS ISSUED DUE TO THE FACT THE RIG WAS WORKING DURING THE COI/DD EXAM CONDUCTEDBY MIONY ON 17 APR 88.
Fire Fighting
Issued 22 November 1985
Resolved
HAVE INSTALLED ON BOTH HALON SYSTEMS CORRECT ISOLATION VALVE FOR REMOTE ACTIVATION OF SYSTEMS. UNTIL SUCH TIME THAT THESE VALVES ARE INSTALLED THERE SHALL BE PLACED ON THE INSTRUCTIONS PLACARD OF THE HALON SYSTEM A NOTICE THAT THE HALON SYSTEM CAN ONLY BE LOCALLY ACTIVATED.
Engineering
Issued 22 November 1985
Resolved
BEFORE PLACING THE NEWLY INSTALLED THERMAL FLUID HEATER INTO OPERATION, A TEST AS OUTLINED IN FIELD TEST PROCEDURE SHALL BE CARRIEDOUT BY A USCG LIC. ENGINEER & THE RESULT OF THE TEST SHALL BE TELEXED TO [name withheld] WITH THE SAME & CG LIC. NUMBER OF THE PERSON WHO PERFORMED THE TESTING.
Unknown
Issued 22 November 1985
Resolved
STRUCTURAL FIRE PROTECTION ON AFT A-60 BLKHD TO BE SENT TO UL LAB. FOR TESTING & APPROVAL-COPIES OF UL RESPONSE TO BE SENT OT [name withheld]1) ROCK- WOOL INSULATION 2) INSULATION BOARD USED IN CONJUNCTION W/ROCKWOOL 3) FLAM-EMASTIC CAULKING USED ON ELETRICAL PENETRATIONS ON A-60 BLKHD.
Lifesaving
Issued 22 November 1985
Resolved
THERE SHALL BE PLACED ON BOTH LIFE CAPSULES A DOWNGRADING SLATE FROM 54-53 PERSONS. CONTACT "WHITTAKER" FOR PLATE. INSTALLATION OF FIXED LIFEBOAT RADIOS REDUCED CAPACITY IN EACH CAPSULE FROM 54-53.
Unknown
Issued 22 November 1985
Resolved
THE FOLLOWING PLANS SHALL BE SENT TO CGD3(MMT) IMMEDIATELY: 1) HALON SYSTEMS 2) FUEL TANK FOR EMERGENCY GENERATOR 3) CERTIFICATES FOR ALL CABLING INSTALLED ON RIG DURING MODIFICATIONS.
Casualty record · 1
27 April 2003Routine · role: Involved in a Marine Casualty · activity 1788338
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
GLOMAR MAIN PASS I (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.