Records from 1982 to 1989. Most recent: inspection, 27 March 1989.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
27 March 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344375
22 March 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1344682
7 March 1989
Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 888596
11 November 1988
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205567
18 September 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1044979
24 August 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002142
18 August 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002730
19 September 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007476
8 November 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302088
25 October 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994087
11 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284008
17 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279380
1 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971374
Construction/Loadline
Issued 18 September 1988
Resolved
REPAINT ALL HULL MARKINGS.
Condition: Unknown
Due 18 September 1988
Resolved 18 September 1988
Accommodation/Occupational Safety
Issued 18 September 1988
Resolved
PROVIDE AIR DIFFUSERS FOR THE AIR CONDITIONING DUCT OUTLETS.
Condition: Unknown
Due 18 September 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 18 September 1988
Resolved
REPLACE LADDER TO AFT STOWAGE HOLD.
Condition: Unknown
Due 18 September 1988
Resolved 18 September 1988
Unknown
Issued 18 September 1988
Resolved
REMARK THE PRESSURE RELIEF VALVE ON THE AIR RECEIVER.
Condition: Unknown
Due 18 September 1988
Resolved 18 September 1988
Electrical
Issued 18 September 1988
Resolved
REMOVE ALL DEAD END WIRING.
Condition: Unknown
Due 18 September 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 18 September 1988
Resolved
PROPERLY SUPPORT ALL ELECTRICAL WIRING.
Condition: Unknown
Due 18 September 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 18 September 1988
Resolved
PROVIDE COVERS AND GUARDS FOR ALL ELECTRIC LIGHT FIXTURES.
Condition: Unknown
Due 18 September 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 18 September 1988
Resolved
SEAL OPEN STUFFING TUBES LOCATED IN CONTROL HOUSE.
Condition: Unknown
Due 18 September 1988
Resolved 18 September 1988
Navigation
Issued 18 August 1987
Resolved
INSTALL NAVIGATION LIGHTS THAT MEET U.S. STANDARD 1104 OR PROVIDE A CERTIFICATE OF ALTERNATIVE COMPLIANCE.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Accommodation/Occupational Safety
Issued 18 August 1987
Resolved
REMOVE EXCESS QUARTERS FROM VESSEL.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Engineering
Issued 18 August 1987
Resolved
INSTALL OILY WATER SEPERATOR IN BILGE SYSTEM WITH APPROPRIATE DISCHARGE ALARM OR MONITOR.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Fire Fighting
Issued 18 August 1987
Resolved
SECURE BV FIRE EXTINGUISHER TO BULKHEAD OR DECK.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Engineering
Issued 18 August 1987
Resolved
REMOVE PLASTIC SIGHT GLASS FROM FUEL OIL DAYTANK.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Navigation
Issued 18 August 1987
Resolved
SECURE STERN LIGHT SO IT IS VISIBLE AND FACING DIRECTLY AFT.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Electrical
Issued 18 August 1987
Resolved
REMOVE EXCESS DEAD HEAD WIRING, AND SECURE WIRING PROPERLY.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Electrical
Issued 18 August 1987
Resolved
BATTERIES FOR WINCH ENGINES ARE TO BE PLACED IN A LEAD LINED BOX, OR BOX CONSTRUCTED OF A SUITABLE CORROSIVE RESISTANT MATERIAL WITH COVER.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987