Records from 1982 to 2022. Most recent: inspection, 17 May 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 74
17 May 2022
Type not recorded
No type recorded · USCGC RIDLEY (WPB 87328) · USCG Southeast District (CGD-SE) · Activity 7454211
15 November 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7100836
23 March 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6930370
10 January 2020
Internal Structural Exam · Hull Examination · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6887288
18 September 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814678
11 February 2019
Deficiency Check · Administrative Inspection · Annual Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6624031
11 April 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6390451
15 March 2018
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6372262
26 February 2018
Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6345864
28 June 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6191840
4 April 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6117575
22 February 2017
Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6092975
8 June 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5907179
22 March 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5838590
16 February 2016
Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5815855
12 January 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5796117
28 May 2014
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4830705
10 March 2014
Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4803304
8 December 2010
Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3893151
1 February 2010
COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3651402
5 May 2009
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3468007
17 March 2009
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3434961
8 January 2009
Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3390672
14 October 2008
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3344644
17 April 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3176883
17 March 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3163190
26 April 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2907517
12 April 2007
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2902217
7 March 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2883482
17 March 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2603872
2 March 2006
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2565877
23 February 2005
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2297553
30 August 2004
Annual Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2170777
18 November 2003
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1943283
24 April 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1770150
26 June 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1659069
20 June 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1635429
3 April 2002
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1484187
19 April 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1062657
3 April 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1061517
17 April 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1048490
18 January 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1403035
25 May 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421721
12 May 1998
Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1402671
14 August 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1119289
1 July 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1114915
15 May 1997
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1439878
30 July 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 643658
11 July 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1091035
23 May 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1398460
21 March 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 212689
21 March 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1411285
25 April 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1443581
17 May 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1321634
5 May 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 826446
1 April 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1137214
20 May 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 955841
18 March 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1318201
17 September 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 938834
27 June 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1246860
25 June 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1222353
9 May 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 909653
12 March 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 909651
17 May 1990
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 908678
17 April 1990
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1239832
14 April 1989
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1030567
12 April 1988
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1340611
11 June 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1336306
29 April 1987
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1025046
30 April 1986
Re-Inspection · Credit Drydock
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1306508
17 April 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 979388
31 May 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280336
28 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277337
3 June 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278086
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2020
Resolved
MDE's excessive leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: gaskets replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 March 2020
Resolved
Valves not working. All need to be checked.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: serviced
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 5 March 2020
Resolved
fix oil leaks and clean e/r
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: cleaned
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2020
Resolved
Broken hand rail support and loose hardware.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: Fixed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2020
Resolved
Genset has excessive oil and dirt buildup on windings.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: cleaned
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 10 January 2020
Resolved
provide permanent means for overnight accommodation egress.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: Provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2019
Resolved
found 02 receptacles with no ground.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 10 October 2019
Resolution: ground wires connected.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 2 April 2019
Resolved
FCC Marine Radio Operator Permit not onboard, provide valid permit.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2019
Resolution: Provided evidence of FCC Marine Radio Operator permit
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 April 2019
Resolved
Updated US Coast Pilot, CG Light List, and Tide Tables not onboard. Provide updated publications.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2019
Resolution: Provided picture evidence of updated publications
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 April 2019
Resolved
Retroreflective tape on life float not serviceable. Replace retro tape with type II.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 April 2019
Resolution: Provided picture of replaced retroreflective tape on life float.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 February 2019
Resolved
Flares on skiffs are expired. Provide new flares for each skiff.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2019
Resolution: Provided picture evidence of new flares for skiffs
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 March 2018
Resolved
Need DAPI Policy onboard vessel.
Action required: 10 - Deficiency Rectified
Due 11 April 2018
Resolved 11 April 2018
Resolution: Verified that DAPI policy was onboard.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 March 2018
Resolved
Need alcohol test strips aboard.
Action required: 10 - Deficiency Rectified
Due 27 April 2018
Resolved 11 April 2018
Resolution: Verified that alcohol test strips are on board.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 March 2018
Resolved
Need current US Coast Pilot and Light List.
Action required: 10 - Deficiency Rectified
Due 27 April 2018
Resolved 11 April 2018
Resolution: Verified current copies of US Coast Pilot and Light List are on board.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 March 2018
Resolved
Replace forward berthing, below deck, emergency lighting.
Action required: 10 - Deficiency Rectified
Due 27 April 2018
Resolved 11 April 2018
Resolution: Verified that forward berthing, below deck, emergency lighting was replaced.
Navigation › Piloting/Steering › Marine Charts
Issued 27 March 2018
Resolved
Need one new chart #11363
Action required: 10 - Deficiency Rectified
Due 27 April 2018
Resolved 11 April 2018
Resolution: Verified new chart was on board.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 May 2017
Resolved
Need Consortium Enrollment letter and proof of Supervisor training. IAW 46 CFR 16
Action required: 10 - Deficiency Rectified
Due 30 June 2017
Resolved 11 April 2018
Resolution: Verifired Consortium enrollment letter and proof of supervisor training.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 May 2017
Resolved
Enter MMSI into VHF-DSC. IAW 46 CFR 184.502
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 31 May 2017
Resolution: Vessel operator properly entered MMSI in to VHF-DSC radio.
Navigation › Piloting/Steering › Marine Charts
Issued 31 May 2017
Resolved
Update charts. IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that charts were updated.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 31 May 2017
Resolved
Emergency instructions need to be posted at the operating station. IAW 46 CFR 185.510
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that emergency instructions were posted at the operating station.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 May 2017
Resolved
Need emergency lighting in FWD berthing and STBD berthing. IAW 46 CFR 184.30-5
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that emergency lighting in FWD berthing and STBD berthing were in place.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2017
Resolved
Wires on port and starboard side of engine room need zip ties replaced with proper supports. IAW 46 CFR 183.10-20
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that wires on port and starboard side of engine room were properly supported.
Lifesaving › Lifebuoys › Serviceable
Issued 31 May 2017
Resolved
Replace life ring and properly label and install retroreflective tape. IAW 46 CFR 180.70
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that life ring was replaced and properly marked and retroreflective tape was installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2017
Resolved
Replace life ring water light tether. Tether needs to be at least 3’ – 6’ long and attached around the body of the ring. 46 CFR 180.70
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that life ring water light tether was replaced, atleast 3' - 6' long and attached around the body of the ring.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 31 May 2017
Resolved
Life float water light tether needs to be secured around the body of the life float. IAW 46 CFR 180.137
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that life float water light tether was secured around the body of the life float.
Engineering › Bilge Water Management System › Piping
Issued 31 May 2017
Resolved
Replace PVC pipe on submersible pumps with rigid flexible hose in engine room and FWD compartment. IAW 46 CFR 182.530
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 5 March 2020
Resolution: Renewed.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 31 May 2017
Resolved
Label fuel shut off valves. 46 CFR 185.608
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that fuel shut off valves were properly labeled.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 31 May 2017
Resolved
Repair/replace hose fitting at end of exhaust, on both sides, in lazerette. IAW 46 CFR 182.425
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that hose fittings at end of exhaust, on both sides, had new hose clamps.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 14 April 2016
Resolved
Water tight hatches need adjusted, to tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 14 April 2016
Resolution: Adjusted and works properly.
Construction/Loadline › Penetrations › Gasket
Issued 14 April 2016
Resolved
Laz fwd bulkhead needs more sealant where light shows thru.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Issue resolved
Documentation › Logs/Records › Drug Test Records
Issued 14 April 2016
Resolved
DAPI training and letter for all crew members not available.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Records provided
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 April 2016
Resolved
Smoke detectors not UL217.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Smoke detectors working
Fire Fighting › Means of Escape › Emergency Lighting
Issued 14 April 2016
Resolved
Emergency lighting not bright enough.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Emergency lighting operational
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 14 April 2016
Resolved
Water light for life ring not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 14 April 2016
Resolution: Water light works, new battery installed.
Engineering › Steering Gear System › Piping
Issued 14 April 2016
Resolved
Steering piping in laz needs proper clamps, hold downs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Steering gear clamps adequate
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2016
Resolved
Dead end wires in bridge need removed or placed in proper box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Dead end wires placed in box.
Electrical › Electric Supply System (service) › Cable
Issued 14 April 2016
Resolved
Missing proper wire support in engine room, bridge, and accomodation space.
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Wire supports added
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 14 April 2016
Resolved
Voltage regulator on aft bulkhead just behind generator needs repaired or removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Voltage regulator issue resolved
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 April 2016
Resolved
Exhaust water leak found on stbd main deisel engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Water leak issue resolved
Navigation › Piloting/Steering › Marine Charts
Issued 14 April 2016
Resolved
Updated charts and pubs need to be on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Updated charts and pubs provided.
Engineering › Pressure Vessel › Relief Valve
Issued 6 May 2014
Resolved
Replace water heater relief valve with on rated at 100 PSI or less IAW 46 CFR 182.320
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 26 June 2014
Communications › Alarms/Indicators › Fire Alarm
Issued 6 May 2014
Resolved
Smoke detector in forward bunk room was inoperable, replace batter or detector to prove proper operation.
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 26 June 2014
Resolution: O/O replaced battery and proved proper operation.
Lifesaving › Lifefloat › Painter
Issued 6 May 2014
Resolved
Replace painter and grab line on lifefloat IAW 46 CFR 180.200
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 26 June 2014
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2014
Resolved
Replace retro and repair life ring buoy IAW manufactures recommendations per 46 CFR 180.70
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 26 June 2014
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 6 May 2014
Resolved
Replace insulation on port engine exhaust IAW 46 CFR 177.970
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 26 June 2014
Electrical › Electrical Distribution System (emergency) › Cable
Issued 6 May 2014
Resolved
Place spliced electrical wire in amidships bunk room for bilge system in an enclosure or utilize a pressure connector per 46 CFR 183.340(i)(1)
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 26 June 2014
Electrical › Electrical Distribution System (service) › Switchboard
Issued 1 February 2010
Resolved
Provide and install a blank in the main distribution panel IAW 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Installed a blank in the main distribution panel.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 February 2010
Resolved
Provide updated publications IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Provided updated publications.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 1 February 2010
Resolved
Prove proper operation of the port main engine clutch IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Proved operation of port main engine.
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 1 February 2010
Resolved
Prove generator is derated IAW 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Proved generator is derated.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 February 2010
Resolved
Provide eyewash for first aid kit IAW 46 CFR 184.710
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Provided new eyewash fir first aid kit.
Engineering › Freshwater System (jacketwater cooling) › Suction Strainer
Issued 1 February 2010
Resolved
Replace wing nuts on raw water strainers for main engine cooling water IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Replaced wing nuts on raw water strainers to main engine cooling water.
Communications › Radio Communications › EPIRB
Issued 1 February 2010
Resolved
Provide and install hydrostatic release on EPIRB IAW 46 CFR 185.740.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Provided new hydrostatic release for EPIRB.
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 1 February 2010
Resolved
Secure leaks on fuel oil mainifold IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Fixed leaks on fuel oil mainifold.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 February 2010
Resolved
Provide guards over alternator and pulley on main engine IAW 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Provided guards over alternator and pulley on main engine.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 February 2010
Resolved
Replace waterlight bracket for lifefloat IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Replaced waterlight bracket for lifefloat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 February 2010
Resolved
Replace waterlight for life ring buoy and lifefloat IAW 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 2 March 2010
Resolution: Replaced waterlight for life ring buoy and lifefloat.
Communications › Radio Communications › EPIRB
Issued 8 April 2009
Resolved
Register EPIRB with NOAA per 46 CFR 180.64. Vessel shall not operate seaward of the territorial sea line of demarcation until cleared.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 12 January 2016
Resolution: EPIRB is properly registered.
Lifesaving › Lifefloat › Markings
Issued 8 April 2009
Resolved
Renew retroreflective tape and vessel name on lifefloat per 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 11 May 2009
Resolution: Retroreflective tape on lifefloat was replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 April 2009
Resolved
Replace expired items in first aid kit per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 11 May 2009
Resolution: All items in first aid kit are not expired.
Engineering › Fuel Oil Service System › Filter
Issued 8 April 2009
Resolved
Make repairs to secure fuel oil leaks on the fuel filters and on the fuel manifold per 46 CFR 182.01-5.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 11 May 2009
Resolution: Replaced the gasket in the manifold; leaks repaired.
Engineering › Lubricating Oil Service System › Valve
Issued 8 April 2009
Resolved
Secure lube oil leaks on port and stbd main engines in way of inspection covers, valve covers, heads, and RPM output mechanisms per 46 CFR 182.01-5.
Action required: 705 - Other - as specified
Due 8 May 2009
Resolved 11 May 2009
Resolution: Leaks were properly repaired.
Construction/Loadline › Hull › Keel
Issued 8 January 2009
Resolved
Replace aft end of worm shoe
Action required: 705 - Other - as specified
Due 13 February 2009
Resolved 17 February 2009
Resolution: Aft end of worm shoe replaced.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 8 January 2009
Resolved
Repair leaking freshwater tank in lazarette.
Action required: 705 - Other - as specified
Due 13 February 2009
Resolved 17 February 2009
Resolution: Replaced freshwater tanks and satisfactorily reattached deck that was cut out for tank installation.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 January 2009
Resolved
Install rail courses at aft entryway as per 46 CFR 177.900(a)
Action required: 705 - Other - as specified
Due 13 February 2009
Resolved 17 February 2009
Resolution: Rail courses installed at after entry.
Documentation › Certificates/Documents › FCC SSL
Issued 17 March 2008
Resolved
Provide a FCC radio telephoney certificate.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 17 April 2008
Resolution: A current FCC radio telephony certificate was onboard the vessel.
Communications › Radio Communications › EPIRB
Issued 17 March 2008
Resolved
Replace EPRIB hydrostatic release and mount the EPRIB in a float free arrangement.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2008
Resolved 17 April 2008
Resolution: The hydro release was renewed for the EPIRB and the EPIRB was relocated to a float free position.
Engineering › Bilge Water Management System › Valve
Issued 17 March 2008
Resolved
Install a check in each bilge pump suction line.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 17 April 2008
Resolution: Check valves were installed in the bilge suction lines at the manifold.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 April 2007
Resolved
Provide a current U.S. Coast Pilot [name withheld], Tidal Current Tables and Navigational Rules of the Road as per 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 26 April 2007
Resolution: Provided a current US Coast Pilot [name withheld], Tidal Current Tables, and Navigational Rules of the Road.
Communications › Radio Communications › EPIRB
Issued 12 April 2007
Resolved
Provide proof of servicing the EPIRB in way of the battery expiration date as per 46 CFR 180.64.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 26 April 2007
Resolution: Provided proof of battery expiration for the EPRIB
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 April 2007
Resolved
Repalce the lanyard for the waterlight on the lifefloat as per 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 26 April 2007
Resolution: Replaced the lanyard for the waterlight on the lifefloat
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 April 2007
Resolved
Replace the tending line for the ring lifebuoy as per 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 26 April 2007
Resolution: Replaced the tending line for the ring lifebuoy
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 April 2007
Resolved
Provide a Coast Guard approved first aid kit as per 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 26 April 2007
Resolution: Provide Coast Guard approved first aid kit.
Documentation › Certificates/Documents › FCC SSL
Issued 17 March 2006
Resolved
Provide a current FCC station license as required by 46 CFR. 184.502
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 11 April 2006
Resolution: Provided proof of FCC station license.
Documentation › Manuals/Policy Documentation › Vessel Action Plan (SIP)
Issued 17 March 2006
Resolved
Provide a voyage plan as required by 46 CFR 185.504.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 11 April 2006
Resolution: Provided a voyage plan.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 17 March 2006
Resolved
Provide and post the emergency instructions list as required by 46 CFR 185.510.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 11 April 2006
Resolution: Provided and posted the emergency instructions list.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 March 2006
Resolved
Provide guards for lights in the lazarette as required by 46 CFR 183.410.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 11 April 2006
Resolution: Provided guards for lights.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 March 2006
Resolved
Replace lighting globe for light on the port side in the lazarette as required by 46 CFR 183.410
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 11 April 2006
Resolution: Replaced light globe.
Engineering › Bilge Water Management System › Pump
Issued 17 March 2006
Resolved
Prove proper operation of the bilge pump in the lazarette as required by 46 CFR 176.804.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 11 April 2006
Resolution: Proved operation of bilge pump.
Electrical › Electric Generation Source (service) › Generator
Issued 17 March 2006
Resolved
Clean the winding of the ships service generator as required by 46 CFR 176.830.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 11 April 2006
Resolution: Cleaned generator windings.
Lifesaving › Lifefloat › Serviceable
Issued 17 March 2006
Resolved
Service the life float or replace it as required by 46 CFR 176.808.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 11 April 2006
Resolution: Marine Safety Services, serviced the lifefloat.
Construction/Loadline › Hull › Keel
Issued 2 March 2006
Resolved
Replace the damaged section of the worm shoe.
Due 2 April 2006
Resolved 8 March 2006
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 2 March 2006
Resolved
Provide and install the propellers on both shafts.
Due 2 April 2006
Resolved 8 March 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 August 2004
Resolved
Provide coast pilot & rules of the road IAW 46CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 29 September 2004
Resolution: Coast pilot provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 August 2004
Resolved
Correct wiring to lazzarette bilge pump light IAW 46 CFR 182.530
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 29 September 2004
Resolution: Wiring corrected.
Stability › Weathertight Integrity › General
Issued 30 August 2004
Resolved
Renew glass aft port and starboard pilothouse IAW 177.102.
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 29 September 2004
Resolution: Glass renewed.
Electrical › Electric Supply System (service) › Cable
Issued 30 August 2004
Resolved
Repair shore tie plug IAW 46CFR 183.340
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 29 September 2004
Resolution: Plug repaired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 August 2004
Resolved
Provide bilge high level alarm forward of the collision bulkhead IAW 182.530
Action required: 705 - Other - as specified
Due 30 September 2004
Resolved 29 September 2004
Resolution: High level alarm installed and operational.
Lifesaving › Lifebuoys › Serviceable
Issued 30 August 2004
Resolved
Renew ring life bouy IAW 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2004
Resolved 30 August 2004
Resolution: Purchased new lifebouy.
Engineering › Steering Gear System
Issued 18 November 2003
Resolved
Replace plywood spacer in way of steering ram support. LEGACY COMPONENT DESC: Ram
Action required: 705 - Other - as specified
Due 18 December 2003
Resolved 8 March 2004
Resolution: Plywood spacer was replaced.
Stability › Watertight Integrity
Issued 18 November 2003
Resolved
Replace butt block in engine room at starboard main engine raw water valve.
Action required: 705 - Other - as specified
Due 18 December 2003
Resolved 8 March 2004
Resolution: The butt block was replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 April 2003
Resolved
Conduct annual servicing of all portable fire extinguishers and fixed fire suppression system as required by 46 CFR 176.810(b). LEGACY COMPONENT DESC: Condition
Due 30 May 2003
Resolved 24 April 2003
Resolution: Annual service performed on Extingushers and fixed fire system.
Communications › Radio Communications
Issued 20 June 2002
Resolved
Provide battery for EPIRB as required by 46CFR180.15 no later than 30Jun02 to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: EPIRB
Due 30 June 2002
Resolved 26 June 2002
Communications › Internal Communications System
Issued 20 June 2002
Resolved
Provide speaker for Public Address system in lower forward berthing as required by 46CFR184.610 no later than 20Jul02.
Due 20 July 2002
Resolved 26 June 2002
Engineering › Bilge Water Management System
Issued 20 June 2002
Resolved
Replace bilge flex hose in steering lazerette with proper hose as required by 46CFR 182.710, to be completed no later than 20Jul02, to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Hose
Due 20 July 2002
Resolved 26 June 2002
Documentation › Certificates/Documents
Issued 20 June 2002
Resolved
Provide FCC safety certificate as required by 47CFR part 80. LEGACY COMPONENT DESC: FCC SSL
Due 20 July 2002
Resolved 26 June 2002
Construction/Loadline › Hull
Issued 5 February 2002
Resolved
Replace plank located 15ft. aft of stem stbd side at chine, where through hull rotted wood. LEGACY COMPONENT DESC: Side Shell
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2002
Resolved 3 April 2002
Resolution: Pland was replaced as original.
Construction/Loadline › Hull
Issued 5 February 2002
Resolved
Provide repair proposal for cracked deck shelf 4ft. forward of aft engine room bulkhead. LEGACY COMPONENT DESC: deck shelf
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2002
Resolved 3 April 2002
Resolution: The cracked shelf was reinforced in a similiar fashion as sistering. It was also reenforced with a pieced of angle iron.
Construction/Loadline › Penetrations
Issued 5 February 2002
Resolved
Replace gasket in most aft hatch. LEGACY COMPONENT DESC: Gasket
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2002
Resolved 3 April 2002
Resolution: A new gasket was put in the hatch.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 5 February 2002
Resolved
Repair fuel leak on fuel manifold in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2002
Resolved 3 April 2002
Resolution: Leak on fuel manifold was repaired by tightening packing.
Construction/Loadline › Hull
Issued 5 February 2002
Resolved
Remove angel hair throughout engine room and treat with wood preservative.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2002
Resolved 3 April 2002
Resolution: Angel hair was removed with a nylon brush and vacuumed up. Engine room was then treated with a
wood preservative.
Engineering › Bilge Water Management System
Issued 5 February 2002
Resolved
Remove oil from engine room bilges, make ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2002
Resolved 3 April 2002
Resolution: Oil removed from bilges.
Electrical
Issued 3 April 2001
Resolved
HARDWIRE IN LIGHT FIXTURE LOCATED IN LOWER FWD BERTHING AS REQUIRED BY 46 CFR 183.410
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Fire Fighting
Issued 3 April 2001
Resolved
PROVIDE ANNUAL SERVICING CERTIFICATE FOR FIXED FIRE EXTINGUISHING SYSTEM ASREQUIRE BY 46 CFR 176.810(B)(2)
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Electrical
Issued 3 April 2001
Resolved
PROVIDE EMERGENCY LIGHTING FOR SALON AREA AS REQUIRED BY 46 CFR 183.432
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Navigation
Issued 3 April 2001
Resolved
PROVIDE UPDATED CHARTS AND PUBLICATIONS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Construction/Loadline
Issued 3 April 2001
Resolved
PROVIDE NEW GASKET FOR FORE PEAK HATCH AS REQUIRED BY 46 CFR 176.802
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Lifesaving
Issued 3 April 2001
Resolved
PROPERLY MARK UPPER DECK FOR NUMBER OF PASSENGERS ALLOWED AS REQUIRED BY 46CFR 185.602(G)
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Lifesaving
Issued 3 April 2001
Resolved
RECONDITION LIFE FLOAT WHERE HOLED, PROVIDE PADDLES AND SPLICE WEAKLINK TO PAINTER AS REQUIRED BY 46 CFR 180.200(A)(2)_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Engineering
Issued 3 April 2001
Resolved
LABEL EMERGENCY FUEL SHUTOFF VALVES AS REQUIRED BY 46 CFR 185.608
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Accommodation/Occupational Safety
Issued 3 April 2001
Resolved
PROVIDE RAIL COURSES ON FANTAIL AND BOW PULPIT AS REQUIRED BY 46 CFR 177.900
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Fire Fighting
Issued 3 April 2001
Resolved
PROVIDE 3 (2 1/2 GALLON BUCKETS WITH ATTACHED LANYARD) AS REQUIRED BY 46 CFR 181.610
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Electrical
Issued 3 April 2001
Resolved
REMOVE DEAD ENDED CABLE FROM FOREPEAK AND HARD WIRE IN HUMIDIFIER LOCATED IN LOWER HEAD AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Construction/Loadline
Issued 12 May 1998
Resolved
PROPERLY REPAIR FRACTURED PLANK PORT SIDE NEAR THE TRANSOM NVIC 7-95.
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Lifesaving
Issued 15 May 1997
Resolved
LINES ON RING BUOY AND WATERLIGHT FOR RING BUOY WERE NOT OF AN APPROVED TYPE. REPLACE LINE IN ACCORDANCE WITH 46 CFR 180.70 (d) AND 180.70(c) PRIORTO COMPLIANCE DATE.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Electrical
Issued 15 May 1997
Resolved
THE VESSEL'S GENERATOR WAS NOT DERATED TO 80% OF AMPERAGE. DERATE GENERATOR IN ACCORDANCE WITH 46 CFR 183.320(b) AND LABEL GENERATOR AS DERATED IN ACCORDANCE WITH 46 CFR 183.320(e) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Engineering
Issued 15 May 1997
Resolved
VESSEL'S INTERNAL COMBUSTION ENGINE FUEL LINES DID NOT HAVE SHUT-OFF VALVESAT THE ENGINES. INSTALL THE VALVES IN ACCORDANCE WITH 46 CFR 182.455(b)(4)PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Construction/Loadline
Issued 15 May 1997
Resolved
WEATHERTIGHT DOOR TO MAIN DECK CABIN DID NOT HAVE A MINIMUM COAMING HEIGHT OF SIX (6) INCHES. ALTER COAMING IN ACCORDANCE WITH 46 CFR 179.360(d) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Engineering
Issued 15 May 1997
Resolved
THE VESSEL'S INDEPENDENT FUEL TANKS WERE NOT GROUNDED TO THE VESSEL'S MAIN GROUND. INSTALL GROUNDING IN ACCORDANCE WITH 46 CFR 182.440 (b)(4) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Lifesaving
Issued 15 May 1997
Resolved
VESSEL'S SKIFFS DID NOT HAVE TYPE I PFD'S. PROVIDE PFD'S IN ACCORDANCE WITH VESSEL'S COI PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Navigation
Issued 15 May 1997
Resolved
OPERATOR DID NOT HAVE A VALID FCC OPERATOR'S LICENSE. PROVIDE A VALID LICENSE IN ACCORDANCE WITH 47 CFR 80.155 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Lifesaving
Issued 15 May 1997
Resolved
OPERATOR COULD NOT PROVIDE EVIDENCE OF 50% OF DECKHANDS HAVING CPR TRAINING. PROVIDE EVIDENCE OF TRAINING IN ACCORDANCE WITH NVIC 1-91 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Lifesaving
Issued 15 May 1997
Resolved
THE VESSEL'S SKIFFS DID NOT HAVE DAY/NIGHT FLARES. PROVIDE FLARES IN ACCORDANCE WITH VESSEL'S COI PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Electrical
Issued 15 May 1997
Resolved
THE VESSEL'S GENERATOR DID NOT HAVE AN AMPERAGE METER. PROVIDE A METER IN ACCORDANCE WITH 46 CFR 183.320(c) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Navigation
Issued 15 May 1997
Resolved
OPERATOR COULD NOT PROVIDE UP-TO-DATE NAVIGATIONAL CHARTS AND PUBLICATIONS.PROVIDE CHARTS AND PUBLICATIONS IN ACCORDANCE WITH 46 CFR 184.420 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Construction/Loadline
Issued 15 May 1997
Resolved
OVERHEAD DECK FRAMING AND GENERATOR MOUNTING FRAME IN ENGINEROOM WAS EXCESSIVELY DETRIORATED BY FUNGUS. CLEAN AND REPAIR IN ACCORDANCE WITH 46 CFR 176.670 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Unknown
Issued 23 May 1996
Resolved
RENEW DEFECTIVE GRAB LINES,NETTING AND PADDLES TO LIFE FLOAT.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Unknown
Issued 23 May 1996
Resolved
REPLACE DEFECTIVE BATTERY TO THE PORT SIDE RING BUOY WATERLIGHT.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Engineering
Issued 23 May 1996
Resolved
ROMOVE AND REPLACE ALL PUSH TYPE FUEL OIL HOSES AND FITTINGS. WITH SAE 1942APPROVED CG FUEL OIL HOSES AND FITTINGS. 46CFR56.50-75(A-3)(B)
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Unknown
Issued 23 May 1996
Resolved
PROVIDE AND POST WASTE MANAGEMENT PLAN
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Engineering
Issued 23 May 1996
Resolved
REMOVE DRAIN PLUGS ON A/C GEN. FUEL FILTER AND INSTALL A PLUG.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Engineering
Issued 23 May 1996
Resolved
INSTALL LARGER PULLEY GUARDS FOR ALL EXISTING GUARDS.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Engineering
Issued 27 June 1991
Resolved
REPLACE PLASTIC 6 GALLON PORTABLE GASOLINE TANKS WITH ABYS APPROVED STEEL TANKS AS STATED ON THE VESSELS COI.
Condition: Unknown
Due 27 June 1991
Resolved 27 June 1991
Construction/Loadline
Issued 9 May 1991
Resolved
PROVIDE RETAINER CABLES FOR ALL MAIN DECK FLUSH DECK HATCH COVERS
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991
Resolved
PROVIDE DUAL HOSE CLAMPS ON ALL VITAL SYSTEMS FLEX HOSE IN ENGINE ROOM.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 17 April 1990
Resolved
PROVIDE MACHINERY GUARDS FOR FRONT END OF PROPULSION ENGINES.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Lifesaving
Issued 17 April 1990
Resolved
MODIFY LIFERAFT HOLDING POST FOR EASIER DEPLOYMENT.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Documentation
Issued 11 June 1987
Resolved
AS REQUIRED BY 46CFR67.23-3(A)(10) THE M/V SOUTHERN BELLE'S CERTIFICATE OF DOCUMENTATION SHALL BE SURRENDERED FOR CORRECTION OF THE ENDORSEMENT WHICH SHOULD READ COASTWISE VICE FISHERIES
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Unknown
Issued 17 April 1985
Resolved
REMOVE GASOLINE FUEL TANKS FROM STERN OF VESSEL, GASOLINE TO BE CARRIED IN 6 GALLON TANK ONLY.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985
Unknown
Issued 17 April 1985
Resolved
REMOVE TINTED PILOT HOUSE WINDOWS. OPERATIONS RESTRICTED TO DAYLIGHT HOURS ONLY, UNTIL WINDOWS ARE CHANGED.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985