MAURY USCG vessel records
← All vessels

SOUTHERN BELLE

Built
1981
Last inspected
17 May 2022
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 May 2022
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC9331
Flag
UNITED STATES
Maury page id
psix-54029

Documentation record

Registered dimensions (L × B × D)58.9 ft × 16.5 ft × 6.5 ft
Registered tonnagegross 58 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRICHARD J DESPORTE · BILOXI MS, UNITED STATES · built 1981
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGULFPORT, MS
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 5 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 40 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

17 May 2022 Type not recorded
No type recorded · USCGC RIDLEY (WPB 87328) · USCG Southeast District (CGD-SE) · Activity 7454211
15 November 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7100836
23 March 2020 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6930370
10 January 2020 Internal Structural Exam · Hull Examination · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6887288
18 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814678
11 February 2019 Deficiency Check · Administrative Inspection · Annual Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6624031
11 April 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6390451
15 March 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6372262
26 February 2018 Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6345864
28 June 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6191840
4 April 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6117575
22 February 2017 Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6092975
8 June 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5907179
22 March 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5838590
16 February 2016 Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5815855
12 January 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5796117

Deficiency record · 40

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2020 Resolved
MDE's excessive leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: gaskets replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 March 2020 Resolved
Valves not working. All need to be checked.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: serviced
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 5 March 2020 Resolved
fix oil leaks and clean e/r
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: cleaned
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2020 Resolved
Broken hand rail support and loose hardware.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: Fixed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2020 Resolved
Genset has excessive oil and dirt buildup on windings.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: cleaned
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 10 January 2020 Resolved
provide permanent means for overnight accommodation egress.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 19 March 2020
Resolution: Provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2019 Resolved
found 02 receptacles with no ground.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 10 October 2019
Resolution: ground wires connected.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 2 April 2019 Resolved
FCC Marine Radio Operator Permit not onboard, provide valid permit.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2019
Resolution: Provided evidence of FCC Marine Radio Operator permit
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 April 2019 Resolved
Updated US Coast Pilot, CG Light List, and Tide Tables not onboard. Provide updated publications.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2019
Resolution: Provided picture evidence of updated publications
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 April 2019 Resolved
Retroreflective tape on life float not serviceable. Replace retro tape with type II.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 April 2019
Resolution: Provided picture of replaced retroreflective tape on life float.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 February 2019 Resolved
Flares on skiffs are expired. Provide new flares for each skiff.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2019
Resolution: Provided picture evidence of new flares for skiffs
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 March 2018 Resolved
Need DAPI Policy onboard vessel.
Action required: 10 - Deficiency Rectified
Due 11 April 2018
Resolved 11 April 2018
Resolution: Verified that DAPI policy was onboard.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 March 2018 Resolved
Need alcohol test strips aboard.
Action required: 10 - Deficiency Rectified
Due 27 April 2018
Resolved 11 April 2018
Resolution: Verified that alcohol test strips are on board.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 March 2018 Resolved
Need current US Coast Pilot and Light List.
Action required: 10 - Deficiency Rectified
Due 27 April 2018
Resolved 11 April 2018
Resolution: Verified current copies of US Coast Pilot and Light List are on board.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 March 2018 Resolved
Replace forward berthing, below deck, emergency lighting.
Action required: 10 - Deficiency Rectified
Due 27 April 2018
Resolved 11 April 2018
Resolution: Verified that forward berthing, below deck, emergency lighting was replaced.
Navigation › Piloting/Steering › Marine Charts
Issued 27 March 2018 Resolved
Need one new chart #11363
Action required: 10 - Deficiency Rectified
Due 27 April 2018
Resolved 11 April 2018
Resolution: Verified new chart was on board.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 May 2017 Resolved
Need Consortium Enrollment letter and proof of Supervisor training. IAW 46 CFR 16
Action required: 10 - Deficiency Rectified
Due 30 June 2017
Resolved 11 April 2018
Resolution: Verifired Consortium enrollment letter and proof of supervisor training.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 May 2017 Resolved
Enter MMSI into VHF-DSC. IAW 46 CFR 184.502
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 31 May 2017
Resolution: Vessel operator properly entered MMSI in to VHF-DSC radio.
Navigation › Piloting/Steering › Marine Charts
Issued 31 May 2017 Resolved
Update charts. IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that charts were updated.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 31 May 2017 Resolved
Emergency instructions need to be posted at the operating station. IAW 46 CFR 185.510
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that emergency instructions were posted at the operating station.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 May 2017 Resolved
Need emergency lighting in FWD berthing and STBD berthing. IAW 46 CFR 184.30-5
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that emergency lighting in FWD berthing and STBD berthing were in place.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2017 Resolved
Wires on port and starboard side of engine room need zip ties replaced with proper supports. IAW 46 CFR 183.10-20
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that wires on port and starboard side of engine room were properly supported.
Lifesaving › Lifebuoys › Serviceable
Issued 31 May 2017 Resolved
Replace life ring and properly label and install retroreflective tape. IAW 46 CFR 180.70
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that life ring was replaced and properly marked and retroreflective tape was installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2017 Resolved
Replace life ring water light tether. Tether needs to be at least 3’ – 6’ long and attached around the body of the ring. 46 CFR 180.70
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that life ring water light tether was replaced, atleast 3' - 6' long and attached around the body of the ring.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 31 May 2017 Resolved
Life float water light tether needs to be secured around the body of the life float. IAW 46 CFR 180.137
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that life float water light tether was secured around the body of the life float.
Engineering › Bilge Water Management System › Piping
Issued 31 May 2017 Resolved
Replace PVC pipe on submersible pumps with rigid flexible hose in engine room and FWD compartment. IAW 46 CFR 182.530
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 5 March 2020
Resolution: Renewed.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 31 May 2017 Resolved
Label fuel shut off valves. 46 CFR 185.608
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that fuel shut off valves were properly labeled.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 31 May 2017 Resolved
Repair/replace hose fitting at end of exhaust, on both sides, in lazerette. IAW 46 CFR 182.425
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 29 June 2017
Resolution: Verified that hose fittings at end of exhaust, on both sides, had new hose clamps.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 14 April 2016 Resolved
Water tight hatches need adjusted, to tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 14 April 2016
Resolution: Adjusted and works properly.
Construction/Loadline › Penetrations › Gasket
Issued 14 April 2016 Resolved
Laz fwd bulkhead needs more sealant where light shows thru.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Issue resolved
Documentation › Logs/Records › Drug Test Records
Issued 14 April 2016 Resolved
DAPI training and letter for all crew members not available.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Records provided
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 April 2016 Resolved
Smoke detectors not UL217.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Smoke detectors working
Fire Fighting › Means of Escape › Emergency Lighting
Issued 14 April 2016 Resolved
Emergency lighting not bright enough.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Emergency lighting operational
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 14 April 2016 Resolved
Water light for life ring not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 14 April 2016
Resolution: Water light works, new battery installed.
Engineering › Steering Gear System › Piping
Issued 14 April 2016 Resolved
Steering piping in laz needs proper clamps, hold downs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Steering gear clamps adequate
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2016 Resolved
Dead end wires in bridge need removed or placed in proper box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Dead end wires placed in box.
Electrical › Electric Supply System (service) › Cable
Issued 14 April 2016 Resolved
Missing proper wire support in engine room, bridge, and accomodation space.
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Wire supports added
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 14 April 2016 Resolved
Voltage regulator on aft bulkhead just behind generator needs repaired or removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Voltage regulator issue resolved
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 April 2016 Resolved
Exhaust water leak found on stbd main deisel engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Water leak issue resolved
Navigation › Piloting/Steering › Marine Charts
Issued 14 April 2016 Resolved
Updated charts and pubs need to be on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 8 June 2016
Resolution: Updated charts and pubs provided.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.