CHANCES R 2 is a 1974 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 1982, most recently in March 2026, along with 191 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1982 to 2026. Most recent: inspection, 31 March 2026.

Built
1974
Last inspected
31 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI5918
Flag
UNITED STATES
367713350 (licence lapsed)
Maury page id
psix-54034

Inspections, by type

…with no type recorded10
Years with a record 41 calendar years (1982–2026)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)49.9 ft × 15.5 ft × 7.1 ft
Registered tonnagegross 41 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRANSTAR, INC. · NEWPORT, FL, UNITED STATES · built 1974
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
35 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI5918MMSI 367713350 · expired · compulsorily equipped · granted 3 February 2016, cancelled 11 April 2026 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 80

31 March 2026 Annual Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8338896
3 September 2025 Administrative Inspection · Special Consideration
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226054
27 May 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8145544
13 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8135110
3 March 2025 Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8087568
17 December 2024 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8049528
29 May 2024 Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7922529
10 April 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7892927
19 March 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7881773
12 April 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7667063
16 March 2023 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7652007
22 July 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7513695
12 April 2022 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7429681
29 March 2022 COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7415491
28 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7270235
5 April 2021 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7171911
24 March 2021 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7161855
18 May 2020 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6938950
4 December 2019 Type not recorded
No type recorded · USCGC ALBACORE (WPB 87309) · USCG Northeast District (CGD-NE) · Activity 6871047
9 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6839070
18 March 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6645076
13 March 2019 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6642369
23 April 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6395528
3 April 2017 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6112948
1 February 2017 Deficiency Check · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6078685
28 September 2016 Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 6011938
5 August 2016 DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5963351
27 July 2015 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5198115
11 July 2012 Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 4376188
14 May 2012 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4308332
1 August 2011 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4098271
14 February 2011 Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3943714
4 May 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3465085
11 February 2009 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3413614
8 February 2009 Type not recorded
No type recorded · USCGC COHO (WPB 87321) · USCG Southeast District (CGD-SE) · Activity 3421289
28 April 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3191078
23 May 2007 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2953142
27 April 2006 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2634559
8 November 2005 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2530980
11 May 2005 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2355857
29 March 2005 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2322853
7 December 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2255016
9 July 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2127509
21 June 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2102928
2 June 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1813392
12 December 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1718080
29 May 2002 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1625725
8 August 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 772374
15 June 2001 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1443207
10 May 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1053969
19 April 1999 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1402855
19 October 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1471372
4 March 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1368603
21 February 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1363977
9 July 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1435793
23 February 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1355666
30 March 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1405691
8 June 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 868172
28 April 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 864059
6 May 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1132425
9 March 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151510
3 March 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 834715
10 June 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 945193
10 June 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 945938
28 April 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1265247
14 May 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1245556
11 December 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 921843
5 March 1990 COI Inspection · Drydock Extension
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1216956
7 March 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 891363
29 November 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 896555
5 August 1988 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039719
8 April 1988 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1345382
4 February 1988 Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1345379
11 March 1987 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1017815
18 March 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1306119
23 August 1985 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 988837
2 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1285620
12 March 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973947
9 March 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973946
29 June 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967247

Deficiency record · 191

02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 May 2025 No resolution recorded
Submit repair proposal for permanent repairs to both fractured longitudinal frames and hatch structure in way of the lazarette space. Repairs to be completed by next credit dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2025 Resolved
Vessel's watchman device could not be tested for satisfactory operation. Vessel is restricted to not more than 06 overnight passengers until system operation can be verified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 May 2025
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 April 2024 Resolved
Make permanent repairs to wasted/worn structural members in lazarette space by next DD/ISE. 1) Submit repair proposal. 2) Remove aluminum bracing on transverse beam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 25 March 2025
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 March 2024 Resolved
Submit repair proposal to correct missing/damaged structural members in lazarette compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 10 April 2024
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 March 2024 Resolved
Separate and ensure proper labeling of child size PFDs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 10 April 2024
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 March 2024 Resolved
Properly mark/stencil life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 10 April 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 March 2023 Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46 CFR 181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 April 2023
Resolution: Interconnected fire detection was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 March 2023 Resolved
Inspect machinery. Excessive oil leaks were noted in vicinity of port and stbd engine turbos.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 11 April 2023
Resolution: Oil leaks repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 March 2023 Resolved
Inspect machinery. Port engine r/w hose was loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 11 April 2023
Resolution: Hose tightened.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 March 2023 Resolved
Inspect radios. VHF DSC radio function was not programmed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2023
Resolved 11 April 2023
Resolution: VHF radio function programmed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2022 Resolved
Propulsion machinery must be of suitable type for intended service in accordance with 46 CFR 182.200. Exhaust cooling water pipes that run above bmde valve covers are made of PVC. Replace by March 2023 drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 11 April 2023
Resolution: PVC components replaced with metallic and acceptable hose.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 March 2022 Resolved
Inspect electrical systems in accordance with 46 CFR 176.806. Egress lighting was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Egress lighting was satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 29 March 2022 Resolved
Inspect lifesaving appliances in accordance with 46 CFR 176.808. Life float light was inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Life float light was satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 29 March 2022 Resolved
Inspect lifesaving appliances in accordance with 46 CFR 176.808. Life float light was secured to mounting bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Life float light was correctly mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 29 March 2022 Resolved
Inspect lifesaving appliances in accordance with 46 CFR 176.808. Top life float was not secured via float free arrangement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Top life float was properly mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 29 March 2022 Resolved
Inspect lifesaving appliances in accordance with 46 CFR 176.808. Ring buoy light was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Ring buoy light was inoperative.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 March 2022 Resolved
Inspect navigation lights in accordance with 46 CFR 176.816. Mast light was not set properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Mast light was not set properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 March 2022 Resolved
Inspect electrical systems in accordance with 46 CFR 176.806. Unsatisfactory electrical splices were present at operating station receptacle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Splices at operating station were satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 March 2022 Resolved
Inspect electrical systems in accordance with 46 CFR 176.806. House battery connections contained spring clips.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: House battery connections were satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2022 Resolved
Inspect machinery in accordance with 46 CFR 176.804. Excessive oil leaks were present on both engines in the vicinity of outboard turbos.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Excessive oil leaks were corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 March 2022 Resolved
Inspect through hull fittings in accordance with 46 CFR 176.802. Stbd rudder post was leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Stbd rudder was satisfactory.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 March 2022 Resolved
Inspect equipment in accordance with 46 CFR 176.816. First aid kit items were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Satisfactory first aid kit was provided.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 29 March 2022 Resolved
Inspect deck in accordance with 46 CFR 176.802. Fwd deck contained multiple delaminations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Fwd deck delaminations were repaired.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 March 2022 Resolved
Inspect lifesaving in accordance with 46 CFR 176.808. Epirb registration was not provided.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Epirb registration was provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2022 Resolved
Provide emergency instructions in accordance with 46 CFR 185. 510. Emergency instructions were not provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Emergency instructions were provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2022 Resolved
Provide nautical publications in accordance with 46 CFR 184.420. Light List/Coast Pilot were not provided.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Light List/ Coast Pilot were provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 March 2022 Resolved
Comply with requirements of FCC in accordance with 46 CFR 184.502. VHF DSC Radio was not programmed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 12 April 2022
Resolution: Radio programmed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 29 March 2022 Resolved
Provide means of escape in accordance with 46 CFR 177.500. Cabin escape hatch could not be opened from the main deck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Cabin escape hatch can be opened from the main deck.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 April 2021 Resolved
The inspected vessel does not currently maintain a Coast Pilot onboard. Vessel is required to have an updated Coast Pilot as appropriate for their intended voyage. Provide proof of updated documentation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: The vessel has updated all Nautical Publications.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 April 2021 Resolved
The inspected vessel currently maintains an expired Federal Communications Commission Safety Radiotelephony Certificate. The vessel is required to maintain a FCC Safety Radiotelephony Certificate onboard. Provide proof of updated document.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 8 April 2021
Resolution: The vessel owner has provided proof of the FCC Safety Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2021 Resolved
The inspected vessel maintains 03 Life-jackets with inoperable lights. Each life-jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have an approved life jacket light approved IAW 46CFR161.012. Provide proof of corrected life jacket lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: Vessel owner has replaced all life-jacket lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021 Resolved
The inspected vessel currently maintains unlabeled breakers throughout multiple spaces. All breakers onboard the vessel are required to be adequately labeled. Provide proof of proper labeling of all breakers onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: Vessel owner replaced all labels for breakers throughout the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 April 2021 Resolved
The inspected vessel does not contain a Rail Guard for the installed stove in the Galley. The vessel is required to maintain a Rail Guard for the installed stove system. Provide proof of Rail Guard.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: The vessel owner properly installed a range grid within the galley.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 5 April 2021 Resolved
The inspected vessel does not have a labeled Escape Hatch on the forepeak. All escape hatches and other emergency exits used as means of escape, must be clearly marked on both sides. Provide proof of properly labeled means of escape throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: The vessel owner properly labeled the Escape Hatch on the forepeak of the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021 Resolved
Electric covers throughout the vessel are missing. The vessel is required to have electrical covers to secure exposed wiring. Provide proof of secured wiring to eliminate electrical hazards throughout the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: The vessel owner properly installed electrical covers throughout the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021 Resolved
The inspected vessel's reel power box shows melted wiring, demonstrating unsafe working conditions. Wiring is required to be installed and maintained to provide services necessary for safety under normal and emergency conditions. Provide evidence of corrected wiring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 8 April 2021
Resolution: Vessel owner replaced all melted wires on the console reel power box.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 April 2021 Resolved
The inspected vessel's forward accommodation space currently maintains an inoperable smoke detector. Maintained fire detection systems onboard shall be rated for maritime use as per 46 CFR part 76. Provide proof of newly acquired smoke detector rated for maritime use.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: The vessel owner replaced the smoke detector with a model rated for maritime use.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 5 April 2021 Resolved
The inspected vessel's sewage system does not contain a Marine Sanitation Device. The vessel shall restrict sewage access until MSD is properly installed or until appropriate action is implemented. Provide proof of correction/installation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 8 April 2021
Resolution: The vessel owner enacted proper repairs to the Marine Sanitation Device.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021 Resolved
The inspected vessel's electrical wires maintain "pigtails" and dead-end wires not in use. Remove all mismanaged wires and ensure that they're installed and maintained to provide services necessary for safety under normal and emergency conditions.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 8 April 2021
Resolution: The vessel owner made all repairs to all wiring onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2020 Resolved
Provide proof of all crew enrollment in a drug consortium.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 18 May 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 May 2020 Resolved
Provide proof of alcohol testing strips or ability to meet testing requirements.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 18 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2020 Resolved
Remove extension cord cable and properly wire washdown pump.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2020
Resolution: Removed extension cord cable and wired washdown pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2020 Resolved
Properly label shore tie/ships power switch controller.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 July 2020
Resolution: Labeled shore tie/ships power switch controller.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 May 2020 Resolved
Provide proof of vessel logs (lifesaving maint, radio, drills)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2020 Resolved
Double hose clamp through hull fittings throughout.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2020
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 October 2019 Resolved
Vessels steering gear ram pedestal plate has pulled away and unsecured. Properly mount ram plate and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2019
Resolution: Owner secured steering gear ram pedestal plate with new bolts, tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 October 2019 Resolved
Properly secure all life float attachments and provide proof of operational life float lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2019
Resolution: Owner secured all life float attachments and proved operation of life float light.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 October 2019 Resolved
Provide proof of valid EPIRB registration prior to operating beyond 3 nautical miles from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 October 2019
Resolution: Owner provided proof of valid EPIRB registration.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 October 2019 Resolved
Provide proof of required man overboard and fire drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2019
Resolution: Owner provided proof of drills, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019 Resolved
Multiple unprotected and dead ended circuits identified throughout pilothouse console and engine room. Pilot house AC power panel missing cover and exposed. Remove all dead ended cabling, provide circuit protection for electrical components, hardwire fixed equipment and install missing receptacle covers throughout.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 14 July 2020
Resolution: All electrical issues have been corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019 Resolved
Provide proof of crew and passenger list.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2019
Resolution: Owner provided proof of crew and passenger list.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019 Resolved
Provide proof of voyage plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2019
Resolution: Owner provided proof of voyage plan.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019 Resolved
Provide proof of emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2019
Resolution: Owner provides proof of emergency instructions.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019 Resolved
Provide outlined duties of watchmen when carrying overnight passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 July 2020
Resolution: Provided watchman duties.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 October 2019 Resolved
Forward berthing hatch unable to be unsecured from the weather deck. Modify or replace to allow access from both above and below decks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 July 2020
Resolution: Corrected forward hatch, tested all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 October 2019 Resolved
Relocate or install additional emergency lighting in accommodation space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 July 2020
Resolution: Instatlled emergency lighting in space, tested all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 October 2019 Resolved
Remount EPIRB to a unhampered free float location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 10 October 2019
Resolution: Remountes EPIRB to a unhampered free float location.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 October 2019 Resolved
Provide updated navigation publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 July 2020
Resolution: Provided updated nav pubs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 October 2019 Resolved
Install additional smoke detector in port berthing area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 July 2020
Resolution: Installed smoke detecter, tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2019 Resolved
Replace 06 adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2019
Resolved 21 March 2019
Resolution: Owner replaced 06 new lifejackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 March 2019 Resolved
Replace romex cable in FWD and AFT engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Romex cable replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 March 2019 Resolved
Replace bilge pump discharge hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Discharge hose replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 March 2019 Resolved
Free seized discharge valves outboard engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Valve freed and tested operation, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 March 2019 Resolved
Install machinery guard on generator pulleys.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Machinery guard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2019 Resolved
Install overboard valves on all discharges within six inches or waterline.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Valves installed, tested operation, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2019 Resolved
Replace or free frozen valve forward of the ships service generator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Valve freed, tested operation, all sat.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 1 February 2017 Resolved
Replace port and stbd cutlass bearing
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2017
Resolved 6 February 2017
Resolution: Vessel replaced bearings
Engineering › Steering Gear System › Rudder
Issued 1 February 2017 Resolved
Repair crack in port rudder mounting assembly
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2017
Resolved 3 February 2017
Resolution: Vessel repaired crack
Engineering › Steering Gear System › Rudder
Issued 1 February 2017 Resolved
Replace bolt in stbd rudder mounting assembly
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2017
Resolved 3 February 2017
Resolution: Vessel replaced bolt
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 August 2016 Resolved
Conduct satisfactory emergency drills
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel completed sat drills
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 10 August 2016 Resolved
Repair/replace STBD engine and conduct operational test
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel replaced engine and performed sat testing
Engineering › Fuel Oil Service System › Valve
Issued 10 August 2016 Resolved
Prove satisfactory operation of emergency fuel shutoff valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel replaced fuel shutoff valves.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 August 2016 Resolved
Provide 3 adult lifejackets and 2 child. Vessel is reduced to 14 adult persons.
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel provided lifejackets
Lifesaving › Lifefloat › Paddle
Issued 10 August 2016 Resolved
Stencil lifefloat oars.
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel properly stencil oars
Lifesaving › Lifebuoys › Serviceable
Issued 10 August 2016 Resolved
Replace ring buoy
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel replaced ring buoy
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 10 August 2016 Resolved
Replace smoke detector
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel replaced detector
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 August 2016 Resolved
Provide updated navigation publications.
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel provided navigation pubs
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 August 2015 Resolved
COD on board is expired
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2015
Resolution: Master provided current DOC to inspector
Lifesaving › Lifefloat › Paddle
Issued 3 August 2015 Resolved
Oars are broken and unserviceable
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2015
Resolved 6 August 2015
Resolution: Vessel renewed oars
Lifesaving › Lifefloat › Painter
Issued 3 August 2015 Resolved
Weak link on vessel end of painter is too small for intended purpose
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2015
Resolution: weak link replaced with proper size
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 3 August 2015 Resolved
Air cleaner on turbo is soaked in oil
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2015
Resolution: air filter replaced with new
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 August 2015 Resolved
FCC Certificate is expired, vessel ops limited to 1000 ft from shore
Action required: 705 - Other - as specified
Resolved 6 August 2015
Resolution: Vessel provided valid certificate
Communications › Radio Communications › EPIRB
Issued 3 August 2015 Resolved
Battery in EPIRB is expired, vessel ops limited to 3nm from shore
Action required: 705 - Other - as specified
Resolved 3 August 2015
Resolution: battery replaced with new
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 August 2015 Resolved
Numerous items used for first aid are expired
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2015
Resolution: first aid kit replaced with new
Electrical › Electric Generation Source (service) › Generator
Issued 3 August 2015 Resolved
Vessel does not have installed amp gauge
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 21 August 2015
Resolution: Vessel installed and tested amp gauge
Lifesaving › Lifefloat › Lifeline
Issued 3 August 2015 Resolved
Fixed loops for attaching lifeline to float are worn and unserviceable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 21 August 2015
Resolution: Vessel renewed lifelines
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 3 August 2015 Resolved
2 adult and 1 child PFD are unserviceable, vessel passenger is reduced to 15 adult and 1 child
Action required: 705 - Other - as specified
Due 17 August 2015
Resolved 6 August 2015
Resolution: Vessel replaced lifejackets
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 3 August 2015 Resolved
Complete a satisfactory DAPI audit
Due 24 August 2015
Resolved 21 August 2015
Resolution: Vessel completed dapi audit.
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 May 2012 Resolved
Provide current U.S. Coast Pilot, light list, and tidal & current tables.
Condition: Invalid
Due 29 May 2012
Resolved 30 May 2012
Resolution: Captain provided current sections of Coast Pilot, light list, and tidal & current tables.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 14 May 2012 Resolved
Provide current CPR cards for 50% of deckhands.
Condition: Invalid
Due 29 May 2012
Resolved 30 May 2012
Resolution: Provided proof of current CPR cards for 50% of deckhands.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2012 Resolved
Install wire support clips every 24" in engine room.
Condition: Invalid
Due 29 May 2012
Resolved 30 May 2012
Resolution: Wire clips were installed every 24" in engine room.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 May 2012 Resolved
Cover or remove outlet box under coffee mess.
Condition: Invalid
Due 29 May 2012
Resolved 30 May 2012
Resolution: Outlet box under coffee mess was installed with a cover.
Construction/Loadline › Hull › Side Shell
Issued 14 February 2011 Resolved
Remove bottom paint from waterline down to keel & contact Marine Inspector for further inspection on hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2011
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 4 May 2009 Resolved
Provide proof of enrollment in a drug consortium for deck hand.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 May 2009 Resolved
Replace starboard running light lens.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 May 2009 Resolved
Provide current coast pilot and light list.
Due 4 June 2009
Resolved 6 May 2009
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 4 May 2009 Resolved
Repair fresh water leak on starboard main diesel engine.
Due 4 June 2009
Resolved 6 May 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 May 2009 Resolved
Replace expired first aid equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 May 2009 Resolved
Replace 1 adult life jacket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2009
Construction/Loadline › Hull › Keel
Issued 11 February 2009 Resolved
Remove delaminated fiberglass on keel and repair affected area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2009
Construction/Loadline › Hull › Side Shell
Issued 11 February 2009 Resolved
Sand and fare area as marked on starboard bow.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2009
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 11 February 2009 Resolved
Replace port and starboard forward and aft cutlass bearings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2009
Engineering › Steering Gear System › Rudder
Issued 11 February 2009 Resolved
Repack port rudder packing and tighten starboard rudder packing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2009
Construction/Loadline › Penetrations › Valve Flange
Issued 11 February 2009 Resolved
Replace thru hull penetration for bait well.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 February 2009 Resolved
Remove debris from anchor locker, dry saturated wood on collision bulkhead, and reseal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 April 2008 Resolved
Fix forward mast running light.
Due 28 May 2008
Resolved 27 May 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 April 2008 Resolved
Affix life line to boat, and attach weak link.
Due 28 May 2008
Resolved 27 May 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 April 2008 Resolved
Provide 01 additional adult PFD.
Due 28 April 2008
Resolved 27 May 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 April 2008 Resolved
Replace life ring buoy battery for float light.
Due 28 April 2008
Resolved 27 May 2008
Engineering › Fuel Oil Service System › Hose
Issued 28 April 2008 Resolved
Clamp fuel line to engine mount port side.
Due 28 April 2008
Resolved 27 May 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 April 2008 Resolved
Install machinery guards for main diesel engines and generator.
Due 28 April 2008
Resolved 27 May 2008
Engineering › Generator (propulsion/auxiliary-electric) › Outlet Box
Issued 28 April 2008 Resolved
Remove excess oil from generator.
Due 28 April 2008
Resolved 27 May 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 28 April 2008 Resolved
Remove old sewage tank.
Due 28 April 2008
Resolved 27 May 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 April 2008 Resolved
Replace stove electrical box.
Due 28 April 2008
Resolved 27 May 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2008 Resolved
Remove unused wiring, behind referigerator and clean excessive debris (fire hazard).
Due 28 April 2008
Resolved 27 May 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 May 2007 Resolved
Deckhand to provide proof of enrollment in a Drug Consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2007
Resolved 24 May 2007
Navigation › Piloting/Steering › Marine Charts
Issued 23 May 2007 Resolved
Obtain current charts, tide/current tables, Coast Pilot and Inland Navigation Rules. COLREGS
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 20 June 2007
Communications › Audible Communications › Horn/Whistle
Issued 23 May 2007 Resolved
Repair ship whistle, noted to be barely audible. COLREGS
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 20 June 2007
Communications › Radio Communications › EPIRB
Issued 23 May 2007 Resolved
Re-registar expired EPIRB registration. 46CFR180.64
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 20 June 2007
Communications › Radio Communications › EPIRB
Issued 23 May 2007 Resolved
Replace expired EPIRB hydrostatic release. 46CFR180.64
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 20 June 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 May 2007 Resolved
Stow PFD's in a space accessible to passengers. PFD's are currrently stowed in the vessel's wheelhouse. 46CFR180
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 20 June 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 23 May 2007 Resolved
Re-route wiring bundles off of MDE fuel lines. 46CFR183
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 20 June 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 May 2007 Resolved
Replace worn raw water recirculating hose on starboard main engine.
Action required: 705 - Other - as specified
Due 23 June 2007
Resolved 20 June 2007
Communications › Radio Communications › EPIRB
Issued 27 April 2006 Resolved
Demonstrate operation of EPIRB as required by 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 April 2006 Resolved
Repair exhaust leak on port main engine as required by 46 CFR 182.425.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 May 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 May 2005 Resolved
Provide proof of enrollment in drug testing program. 46 CFR 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Documentation › Certificates/Documents › FCC SSL
Issued 11 May 2005 Resolved
Provide current FCC Radio Safety Certificate. 47 CFR 80.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Documentation › Logs/Records › Logbook (official)
Issued 11 May 2005 Resolved
Provide means of logging voyage plan and passenger count. 46 CFR 185.504.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 11 May 2005 Resolved
Demonstrate operation of single side band radio. 46 CFR 184.502.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Communications › Radio Communications › EPIRB
Issued 11 May 2005 Resolved
Replace wasted EPIRB antenna. 46 CFR 185.728.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Lifesaving › Lifefloat › Pendant
Issued 11 May 2005 Resolved
Replace life float water light batteries and install 18' foot pendant. 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Lifesaving › Lifefloat › Painter
Issued 11 May 2005 Resolved
Replace wasted life float painter line. 46 CFR 180.200
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 May 2005 Resolved
Replace lifejacket donning placard. 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 May 2005 Resolved
Make ring lifebuoy water light pendant 3'-6' in length and install corrosion resistant clip. 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2005 Resolved
Provide eyewash and replace expired meds in first aid kit. 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 11 May 2005 Resolved
Provide (1) size B-I and (3) size B-II portable fire extinguishers. 46 CFR 176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Fire Bucket › Quantity
Issued 11 May 2005 Resolved
Provide (3) fire buckets: 2.5 gallon, marked "FIRE BUCKET", with lanyard attached. 46 CFR 181.300.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Engineering › Sea-water System (primary cooling) › Valve
Issued 11 May 2005 Resolved
Install handle on port raw water intake. 46 CFR 182.710.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2005 Resolved
Permanently wire wash down pump. 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 11 May 2005 Resolved
Make cable run from engine space to pilothouse vapor tight. 46 CFR 182.465.
Action required: 705 - Other - as specified
Due 11 June 2005
Resolved 8 November 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 7 December 2004 Resolved
Remove port and starboard propulsion shafts for inspection. (46 CFR 176.630)
Action required: 705 - Other - as specified
Due 7 January 2005
Resolved 10 December 2004
Resolution: Shaft examined, found satisfactory and returned to service.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 7 December 2004 Resolved
Replace port and starboard strut and intermediate propulsion shaft bearings. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 7 January 2005
Resolved 10 December 2004
Resolution: All shaft bearings renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2004 Resolved
Repair delaminated hull material in way of port propulsion shaft stern tube.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2005
Resolved 10 December 2004
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2004 Resolved
Repair delaminated hull material in way of starboard propulsion shaft stern tube. (46 CFR 176.800)
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2005
Resolved 10 December 2004
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2004 Resolved
Repair delaminated hull material in way of starboard propulsion shaft - approximately one foot forward of strut. (46 CFR 176.800).
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2005
Resolved 10 December 2004
Construction/Loadline › Penetrations › Valve Flange
Issued 7 December 2004 Resolved
Renew through hull fitting (1/2" gate valve) for salon sink overboard, starboard side machinery space.
Action required: 705 - Other - as specified
Due 7 January 2005
Resolved 10 December 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 December 2004 Resolved
Remove combustible supports from generator exhaust piping system and replace with non-combustible material. (46 CFR 182.20-15).
Action required: 705 - Other - as specified
Due 7 January 2005
Resolved 10 December 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 December 2004 Resolved
Replace wasted pipe nipple on starboard propulsion engine sea water strainer.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2005
Resolved 10 December 2004
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 December 2004 Resolved
Replace wasted hose clamp on generator exhaust flex hose assembly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2005
Resolved 10 December 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 7 December 2004 Resolved
Remove and replace port propulsion engine motor mounts and bed support flanges. Make engine stringers accessible for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2005
Resolved 29 March 2005
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Penetrations › Pipe Flange
Issued 7 December 2004 Resolved
Replace wasted auxiliary sea water through hull fitting under lower passenger accommodation deck
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 January 2005
Resolved 10 December 2004
Fire Fighting › Means of Escape › Doorways
Issued 21 June 2004 Resolved
Mark passenger accommodation escape hatch with "EMERGENCY EXIT - KEEP CLEAR". (46 CFR 185.606)
Action required: 705 - Other - as specified
Due 21 July 2004
Resolved 9 July 2004
Engineering › Bilge Water Management System › Hose
Issued 21 June 2004 Resolved
Provide suitable suction hose for hand operated bilge pump. (46 CFR 181.10-5)
Due 21 June 2004
Resolved 21 June 2004
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 June 2004 Resolved
Replace retro-reflective tape on one adult PFD. (46 CFR 185.604(h).
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 21 June 2004
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 June 2004 Resolved
Repair or replace one adult Type I PFD due to rotten threads on securing strap. Repairs must be made IAW 46 CFR 160.006.
Due 21 June 2004
Resolved 21 June 2004
Resolution: PFD was replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 21 June 2004 Resolved
Provide one Type B/C Size I portable fire extinguisher in the wheelhouse. (46 CFR 181.500(a).
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2004
Resolved 21 June 2004
Electrical › Electrical Distribution System (service) › Conductor
Issued 21 June 2004 Resolved
Remove or terminate to a junction box all exposed dead ended conductors in machinery space. (46 CFR 138.340)
Action required: 705 - Other - as specified
Due 21 July 2004
Resolved 9 July 2004
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 21 June 2004 Resolved
Prove proper operation of smoke detector required by 46 CFR 181.400.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2004
Resolved 21 June 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 June 2004 Resolved
Prove proper operation of pre-engineered fixed gas fire fighting system audible alarm required by 46 CFR 181.420(b)(2).
Action required: 705 - Other - as specified
Due 21 July 2004
Resolved 9 July 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 21 June 2004 Resolved
Repair or replace light fixture in aft passenger accommodation. Fixture must meet UL 1571 "Incandescent Lighting" in accordance with 46 CFR 183.410.
Action required: 705 - Other - as specified
Due 21 July 2004
Resolved 9 July 2004
Electrical › Electrical Distribution System (service) › Conductor
Issued 21 June 2004 Resolved
Mount electrical conductor for hydraulic trim tab motor IAW 46 CFR 183.400.
Action required: 705 - Other - as specified
Due 21 July 2004
Resolved 9 July 2004
Fire Fighting
Issued 15 June 2001 Resolved
HAVE FIXED AND PORTABLE FIRE EXTIGUISHER SERVICED BY AN APPROVED FACILITY OR RESERVICED IN THE PRESENCE ON A MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 July 2001
Resolved 3 July 2001
Navigation
Issued 15 June 2001 Resolved
PROVIDE NAVIGATION PUBLICATIONS (TIDE AND CURRENT TABLES, US COAST PILOT, CG LIGHT LIST) PRIOR TO 15 JULY 01.
Condition: Unknown
Due 15 June 2001
Resolved 15 June 2001
Engineering
Issued 15 June 2001 Resolved
INSTALL MACHINERY GUARDS IAW 46 CFR 177.960 PRIOR TO 15 JULY 01
Condition: Unknown
Due 15 June 2001
Resolved 15 June 2001
Electrical
Issued 15 June 2001 Resolved
REMOVE WIRE NUTS THROUGHOUT VESSEL IAW 46 CFR 183.340 PRIOR TO 15 JULY 01
Condition: Unknown
Due 15 June 2001
Resolved 15 June 2001
Lifesaving
Issued 15 June 2001 Resolved
PRIOR TO CARRYING PASSENGERS, RENEW EPIRB HYDOSTATIC RELEASE.
Condition: Unknown
Due 22 June 2001
Resolved 25 June 2001
Documentation
Issued 15 June 2001 Resolved
PROVIDE FCC SAFETY CERTIFICATE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 June 2001
Resolved 25 June 2001
Engineering
Issued 9 March 1993 Resolved
RENEW WORN FLEXIBLE NON-METALLIC HOSE WHICH ATTACHES TO GENERATOR RAW WATERSUCTION THROUGH HULL FITTING.
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Lifesaving
Issued 9 March 1993 Resolved
RENWE RETRO REFLECTIVE MATERIAL TO LIFE FLOATS.
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Fire Fighting
Issued 9 March 1993 Resolved
REMOVE FROM VESSEL NON-APPROVED FIXED HALON FIRE SUPPRESSION SYSTEM IN ENGINE COMPARTMENT.
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Construction/Loadline
Issued 9 March 1993 Resolved
PROVE OPERATION OF BELT DRIVEN BILGE PUMP
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Electrical
Issued 9 March 1993 Resolved
PROVE OPERATION OF SHIP SERVICE GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Navigation
Issued 9 March 1993 Resolved
PROPERLY SUPPORT ALL HYDRAULIC TUBING TO STEERING SYSTEM.
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Construction/Loadline
Issued 9 March 1993 Resolved
DOUBLE HOSE CLAMP ALL FLEXIBLE HOSES ATTACHED TO THROUGH HULL FITTINGS.
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Navigation
Issued 9 March 1993 Resolved
RENEW LENS TO STARBOARD RUNNING LIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Accommodation/Occupational Safety
Issued 9 March 1993 Resolved
REPAIR AND PROVE OPERATION OF "Y" VALVE IN MARINE SANITATION SYSTEM PIPING.
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Engineering
Issued 9 March 1993 Resolved
REPAIR EXHAUST LEAK ON STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Accommodation/Occupational Safety
Issued 9 March 1993 Resolved
REPAIR PORT AND STARBOARD ENGINE ROOM VENT_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Navigation
Issued 28 April 1992 Resolved
PROVE OPERATION OF COMPASS LIGHT.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Fire Fighting
Issued 28 April 1992 Resolved
ENSURE ALL PORTABLE FIRE EXTINGUISHERS HAVE BEEN SERVICED WITHIN THE PAST 12 MONTHS.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Engineering
Issued 28 April 1992 Resolved
REPAIR EXHAUST LEAK ON STARBOARD EXHAUST PIPE FORWARD OF MUFFLER AT FLEX COUPLING.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Lifesaving
Issued 28 April 1992 Resolved
PROVIDE SIX ORANGE SMOKE DISTRESS SIGNAL.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Engineering
Issued 28 April 1992 Resolved
REMOVE EXISTING FUEL FILTER/STRAINER ASSEMBLIES AND INSTALL MARINE TYPE FILTERS FOR FUEL OIL SYSTEM.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Engineering
Issued 28 April 1992 Resolved
ENSURE ALL FLEXIBLE HOSES IN THE FUEL OIL SYSTEM ARE NO LONGER THAN THIRTY INCHES IN LENGTH.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Lifesaving
Issued 28 April 1992 Resolved
RENEW GRAB LINE TO RING BUOY.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Navigation
Issued 28 April 1992 Resolved
PROVE OPERATION OF RADAR.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Navigation
Issued 28 April 1992 Resolved
PROVE OPERATION OF SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Unknown
Issued 8 April 1988 Resolved
LABEL ALL CIRCUITS ON PANEL BOARD IN PILOT HOUSE.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988 Resolved
MARK LOCATION OF REMOTE F.O.S.O. VALVES IN COCKPIT AREA.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988 Resolved
POST AND SIGN IN LOWER AREA STATING:" 20 ADULT AND 2 CHILD PFD'S STOWED IN PILOT HOUSE".
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Documentation
Issued 11 March 1987 Resolved
PROVIDE EVIDENCE THAT STABILITY TEST HAS BEEN CONDUCTED OR UNDER GO SIMPLIFIED STABILITY TEST.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987

Ownership record