02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 May 2025
No resolution recorded
Submit repair proposal for permanent repairs to both fractured longitudinal frames and hatch structure in way of the lazarette space. Repairs to be completed by next credit dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2025
Resolved
Vessel's watchman device could not be tested for satisfactory operation. Vessel is restricted to not more than 06 overnight passengers until system operation can be verified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 May 2025
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 April 2024
Resolved
Make permanent repairs to wasted/worn structural members in lazarette space by next DD/ISE.
1) Submit repair proposal.
2) Remove aluminum bracing on transverse beam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 25 March 2025
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 March 2024
Resolved
Submit repair proposal to correct missing/damaged structural members in lazarette compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 10 April 2024
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 March 2024
Resolved
Separate and ensure proper labeling of child size PFDs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 10 April 2024
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 March 2024
Resolved
Properly mark/stencil life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 10 April 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 March 2023
Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46 CFR 181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 April 2023
Resolution: Interconnected fire detection was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 March 2023
Resolved
Inspect machinery. Excessive oil leaks were noted in vicinity of port and stbd engine turbos.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 11 April 2023
Resolution: Oil leaks repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 March 2023
Resolved
Inspect machinery. Port engine r/w hose was loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2023
Resolved 11 April 2023
Resolution: Hose tightened.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 March 2023
Resolved
Inspect radios. VHF DSC radio function was not programmed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2023
Resolved 11 April 2023
Resolution: VHF radio function programmed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2022
Resolved
Propulsion machinery must be of suitable type for intended service in accordance with 46 CFR 182.200. Exhaust cooling water pipes that run above bmde valve covers are made of PVC. Replace by March 2023 drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 11 April 2023
Resolution: PVC components replaced with metallic and acceptable hose.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 March 2022
Resolved
Inspect electrical systems in accordance with 46 CFR 176.806.
Egress lighting was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Egress lighting was satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 29 March 2022
Resolved
Inspect lifesaving appliances in accordance with 46 CFR 176.808. Life float light was inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Life float light was satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 29 March 2022
Resolved
Inspect lifesaving appliances in accordance with 46 CFR 176.808. Life float light was secured to mounting bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Life float light was correctly mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 29 March 2022
Resolved
Inspect lifesaving appliances in accordance with 46 CFR 176.808. Top life float was not secured via float free arrangement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Top life float was properly mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 29 March 2022
Resolved
Inspect lifesaving appliances in accordance with 46 CFR 176.808. Ring buoy light was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Ring buoy light was inoperative.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 March 2022
Resolved
Inspect navigation lights in accordance with 46 CFR 176.816. Mast light was not set properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Mast light was not set properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 March 2022
Resolved
Inspect electrical systems in accordance with 46 CFR 176.806. Unsatisfactory electrical splices were present at operating station receptacle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Splices at operating station were satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 March 2022
Resolved
Inspect electrical systems in accordance with 46 CFR 176.806. House battery connections contained spring clips.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: House battery connections were satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2022
Resolved
Inspect machinery in accordance with 46 CFR 176.804. Excessive oil leaks were present on both engines in the vicinity of outboard turbos.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Excessive oil leaks were corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 March 2022
Resolved
Inspect through hull fittings in accordance with 46 CFR 176.802. Stbd rudder post was leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Stbd rudder was satisfactory.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 March 2022
Resolved
Inspect equipment in accordance with 46 CFR 176.816. First aid kit items were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Satisfactory first aid kit was provided.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 29 March 2022
Resolved
Inspect deck in accordance with 46 CFR 176.802. Fwd deck contained multiple delaminations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Fwd deck delaminations were repaired.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 March 2022
Resolved
Inspect lifesaving in accordance with 46 CFR 176.808. Epirb registration was not provided.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Epirb registration was provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2022
Resolved
Provide emergency instructions in accordance with 46 CFR 185. 510. Emergency instructions were not provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Emergency instructions were provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2022
Resolved
Provide nautical publications in accordance with 46 CFR 184.420. Light List/Coast Pilot were not provided.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Light List/ Coast Pilot were provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 March 2022
Resolved
Comply with requirements of FCC in accordance with 46 CFR 184.502. VHF DSC Radio was not programmed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 12 April 2022
Resolution: Radio programmed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 29 March 2022
Resolved
Provide means of escape in accordance with 46 CFR 177.500. Cabin escape hatch could not be opened from the main deck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 7 April 2022
Resolution: Cabin escape hatch can be opened from the main deck.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 April 2021
Resolved
The inspected vessel does not currently maintain a Coast Pilot onboard. Vessel is required to have an updated Coast Pilot as appropriate for their intended voyage. Provide proof of updated documentation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: The vessel has updated all Nautical Publications.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 April 2021
Resolved
The inspected vessel currently maintains an expired Federal Communications Commission Safety Radiotelephony Certificate. The vessel is required to maintain a FCC Safety Radiotelephony Certificate onboard. Provide proof of updated document.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 8 April 2021
Resolution: The vessel owner has provided proof of the FCC Safety Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2021
Resolved
The inspected vessel maintains 03 Life-jackets with inoperable lights. Each life-jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have an approved life jacket light approved IAW 46CFR161.012. Provide proof of corrected life jacket lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: Vessel owner has replaced all life-jacket lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021
Resolved
The inspected vessel currently maintains unlabeled breakers throughout multiple spaces. All breakers onboard the vessel are required to be adequately labeled. Provide proof of proper labeling of all breakers onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: Vessel owner replaced all labels for breakers throughout the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 April 2021
Resolved
The inspected vessel does not contain a Rail Guard for the installed stove in the Galley. The vessel is required to maintain a Rail Guard for the installed stove system. Provide proof of Rail Guard.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: The vessel owner properly installed a range grid within the galley.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 5 April 2021
Resolved
The inspected vessel does not have a labeled Escape Hatch on the forepeak. All escape hatches and other emergency exits used as means of escape, must be clearly marked on both sides. Provide proof of properly labeled means of escape throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: The vessel owner properly labeled the Escape Hatch on the forepeak of the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021
Resolved
Electric covers throughout the vessel are missing. The vessel is required to have electrical covers to secure exposed wiring. Provide proof of secured wiring to eliminate electrical hazards throughout the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: The vessel owner properly installed electrical covers throughout the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021
Resolved
The inspected vessel's reel power box shows melted wiring, demonstrating unsafe working conditions. Wiring is required to be installed and maintained to provide services necessary for safety under normal and emergency conditions. Provide evidence of corrected wiring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 8 April 2021
Resolution: Vessel owner replaced all melted wires on the console reel power box.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 April 2021
Resolved
The inspected vessel's forward accommodation space currently maintains an inoperable smoke detector. Maintained fire detection systems onboard shall be rated for maritime use as per 46 CFR part 76. Provide proof of newly acquired smoke detector rated for maritime use.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 8 April 2021
Resolution: The vessel owner replaced the smoke detector with a model rated for maritime use.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 5 April 2021
Resolved
The inspected vessel's sewage system does not contain a Marine Sanitation Device. The vessel shall restrict sewage access until MSD is properly installed or until appropriate action is implemented. Provide proof of correction/installation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 8 April 2021
Resolution: The vessel owner enacted proper repairs to the Marine Sanitation Device.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021
Resolved
The inspected vessel's electrical wires maintain "pigtails" and dead-end wires not in use. Remove all mismanaged wires and ensure that they're installed and maintained to provide services necessary for safety under normal and emergency conditions.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 8 April 2021
Resolution: The vessel owner made all repairs to all wiring onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2020
Resolved
Provide proof of all crew enrollment in a drug consortium.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 18 May 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 May 2020
Resolved
Provide proof of alcohol testing strips or ability to meet testing requirements.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 18 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2020
Resolved
Remove extension cord cable and properly wire washdown pump.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2020
Resolution: Removed extension cord cable and wired washdown pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2020
Resolved
Properly label shore tie/ships power switch controller.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 July 2020
Resolution: Labeled shore tie/ships power switch controller.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 May 2020
Resolved
Provide proof of vessel logs (lifesaving maint, radio, drills)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2020
Resolved
Double hose clamp through hull fittings throughout.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2020
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 October 2019
Resolved
Vessels steering gear ram pedestal plate has pulled away and unsecured. Properly mount ram plate and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2019
Resolution: Owner secured steering gear ram pedestal plate with new bolts, tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 October 2019
Resolved
Properly secure all life float attachments and provide proof of operational life float lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2019
Resolution: Owner secured all life float attachments and proved operation of life float light.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 October 2019
Resolved
Provide proof of valid EPIRB registration prior to operating beyond 3 nautical miles from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 October 2019
Resolution: Owner provided proof of valid EPIRB registration.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 October 2019
Resolved
Provide proof of required man overboard and fire drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2019
Resolution: Owner provided proof of drills, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Multiple unprotected and dead ended circuits identified throughout pilothouse console and engine room. Pilot house AC power panel missing cover and exposed. Remove all dead ended cabling, provide circuit protection for electrical components, hardwire fixed equipment and install missing receptacle covers throughout.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 14 July 2020
Resolution: All electrical issues have been corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019
Resolved
Provide proof of crew and passenger list.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2019
Resolution: Owner provided proof of crew and passenger list.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019
Resolved
Provide proof of voyage plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2019
Resolution: Owner provided proof of voyage plan.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019
Resolved
Provide proof of emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2019
Resolution: Owner provides proof of emergency instructions.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019
Resolved
Provide outlined duties of watchmen when carrying overnight passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 July 2020
Resolution: Provided watchman duties.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 October 2019
Resolved
Forward berthing hatch unable to be unsecured from the weather deck. Modify or replace to allow access from both above and below decks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 July 2020
Resolution: Corrected forward hatch, tested all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 October 2019
Resolved
Relocate or install additional emergency lighting in accommodation space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 July 2020
Resolution: Instatlled emergency lighting in space, tested all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 October 2019
Resolved
Remount EPIRB to a unhampered free float location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 10 October 2019
Resolution: Remountes EPIRB to a unhampered free float location.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 October 2019
Resolved
Provide updated navigation publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 July 2020
Resolution: Provided updated nav pubs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 October 2019
Resolved
Install additional smoke detector in port berthing area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 July 2020
Resolution: Installed smoke detecter, tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2019
Resolved
Replace 06 adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2019
Resolved 21 March 2019
Resolution: Owner replaced 06 new lifejackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 March 2019
Resolved
Replace romex cable in FWD and AFT engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Romex cable replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 March 2019
Resolved
Replace bilge pump discharge hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Discharge hose replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 March 2019
Resolved
Free seized discharge valves outboard engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Valve freed and tested operation, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 March 2019
Resolved
Install machinery guard on generator pulleys.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Machinery guard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2019
Resolved
Install overboard valves on all discharges within six inches or waterline.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Valves installed, tested operation, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2019
Resolved
Replace or free frozen valve forward of the ships service generator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2019
Resolved 18 March 2019
Resolution: Valve freed, tested operation, all sat.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 1 February 2017
Resolved
Replace port and stbd cutlass bearing
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2017
Resolved 6 February 2017
Resolution: Vessel replaced bearings
Engineering › Steering Gear System › Rudder
Issued 1 February 2017
Resolved
Repair crack in port rudder mounting assembly
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2017
Resolved 3 February 2017
Resolution: Vessel repaired crack
Engineering › Steering Gear System › Rudder
Issued 1 February 2017
Resolved
Replace bolt in stbd rudder mounting assembly
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2017
Resolved 3 February 2017
Resolution: Vessel replaced bolt
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 August 2016
Resolved
Conduct satisfactory emergency drills
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel completed sat drills
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 10 August 2016
Resolved
Repair/replace STBD engine and conduct operational test
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel replaced engine and performed sat testing
Engineering › Fuel Oil Service System › Valve
Issued 10 August 2016
Resolved
Prove satisfactory operation of emergency fuel shutoff valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel replaced fuel shutoff valves.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 August 2016
Resolved
Provide 3 adult lifejackets and 2 child. Vessel is reduced to 14 adult persons.
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel provided lifejackets
Lifesaving › Lifefloat › Paddle
Issued 10 August 2016
Resolved
Stencil lifefloat oars.
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel properly stencil oars
Lifesaving › Lifebuoys › Serviceable
Issued 10 August 2016
Resolved
Replace ring buoy
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel replaced ring buoy
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 10 August 2016
Resolved
Replace smoke detector
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel replaced detector
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 August 2016
Resolved
Provide updated navigation publications.
Action required: 705 - Other - as specified
Due 24 August 2016
Resolved 14 September 2016
Resolution: Vessel provided navigation pubs