Records from 1982 to 2000. Most recent: inspection, 3 October 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
3 October 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1386915
11 December 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 812610
27 October 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402980
12 April 1999
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408291
19 October 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466564
3 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784294
4 November 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375174
17 December 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093475
22 October 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377850
1 October 1996
Hull Examination · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427290
6 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 157139
19 June 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387802
7 June 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353757
22 September 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 867736
6 September 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 689714
2 August 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1175259
26 May 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417655
10 May 1994
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1455160
23 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 70024
14 June 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1373877
30 November 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 828653
9 October 1992
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263715
16 June 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 962546
30 August 1991
Excursion Permit
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248230
5 June 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238972
14 March 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 902973
13 July 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241072
14 June 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929984
17 August 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1338719
23 June 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 893515
11 March 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 990513
26 June 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334640
11 August 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984791
3 July 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985382
4 October 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303161
24 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282860
28 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967473
2 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965537
Engineering
Issued 3 October 2000
No resolution recorded
PROVE AFT SHAFT TACHOMETERS 0N BRIDGE.
Condition: Unknown
Due 3 November 2000 — due date passed with no resolution recorded
Engineering
Issued 3 October 2000
No resolution recorded
PROVE PROPER OPERATION OF ENGINEROOM SHAFT TACHOMETERS.
Condition: Unknown
Due 3 November 2000 — due date passed with no resolution recorded
Lifesaving
Issued 3 October 2000
No resolution recorded
PROVIDE APPROVED FIRE AND SAFETY PLAN._x001C_
Condition: Unknown
Due 3 November 2000 — due date passed with no resolution recorded
Engineering
Issued 3 October 2000
No resolution recorded
PROVIDE AND PROVE PORT SHAFT TACHOMETER IN PILOTHOUSE.
Condition: Unknown
Due 3 November 2000 — due date passed with no resolution recorded
Documentation
Issued 27 October 1999
Resolved
PROVIDE CORRECTED FIRE AND SAFETY PLAN FOR USCG VERIFICATION AND APPROVAL. SCHEDULE CG VISIT TO VESSEL.
Condition: Unknown
Due 27 October 1999
Resolved 27 October 1999
Engineering
Issued 22 October 1996
Resolved
REPAIR OILY WATER SEPERATOR.
Condition: Unknown
Due 10 November 1996
Resolved 6 November 1996
Engineering
Issued 26 May 1994
Resolved
Repair fuel oil transfer pump remote emergency shutdown circuitry. Must also shutdown fuel oil purifier.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Deck/Cargo
Issued 26 May 1994
Resolved
Repair containment for port fueling station and vent. No tranfers shall beconducted from this station until such repairs are made.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Deck/Cargo
Issued 26 May 1994
Resolved
Enlarge port fueling containment area to include attachment extending beyond present containment.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Deck/Cargo
Issued 26 May 1994
Resolved
Make available for internal inspection all dry bulk P-tanks at next drydockbut NLT 16JUN95 (36 month maximum extension per MVI Policy 11-93). Tanks must be emptied, pressure-washed, and certified gas-free prior to entry by CG personnel.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Engineering
Issued 26 May 1994
Resolved
Replace unapproved fuel oil supply hose on #1 generator from fuel oil strainer to fuel oil filters. Must be wire reinforced flame retardant typewith factory type fittings. See 46 CFR 56.60-25(c).
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Engineering
Issued 26 May 1994
Resolved
Remove all brass petcocks in fuel strainers and/or filters on generators, main engines, bow thruster and liquid mud pump engines. Must be mild steelplugs or valves.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Fire Fighting
Issued 26 May 1994
Resolved
Fabricate and install new lables at locations for all remote emergency stops/shutdowns throughout vessel.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Engineering
Issued 26 May 1994
Resolved
Repair and prove proper operation of low lube oil pressure shutdown on forward generator.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Lifesaving
Issued 26 May 1994
Resolved
Make repairs to and prove proper operation of: port aft fuel oil pump shutdown station; stbd aft liquid mup pump shutdown station; bridge aft liquid mud pump shutdown station.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Engineering
Issued 26 May 1994
Resolved
Replace wasted pneumatically operated fuel oil supply valve (remote emergency shutdown) on #3 cargo fuel tank suction piping.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Construction/Loadline
Issued 26 May 1994
Resolved
Provide means to test operation of 15ppm oily water seperator and 15ppm alrm and valve solendoid operation. Consult mfgr of OWS/alarm for possibletest simulations.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Construction/Loadline
Issued 26 May 1994
Resolved
Reweld old cargo deck insert (approx 3'X5'). Insert perimeter weld must bebackgouged and rewelded and properly weld associated overhead longitudinalsin engine room (over stbd main engine).
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Engineering
Issued 26 May 1994
Resolved
Renew section of control air tubing in port engine room console.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Engineering
Issued 26 May 1994
Resolved
Renew or repair tachometer on forward generator.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Navigation
Issued 26 May 1994
Resolved
Install cotter pins or self-locking nuts on steering gear rudder linkages and rudder angle indicator and follow-up linkages.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Lifesaving
Issued 26 May 1994
Resolved
Provide four (4) additional cartridges for line throwing gun to meet required number. Additional cartridges are required for test firing once quraterly.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Engineering
Issued 26 May 1994
Resolved
Replace broken reset buttons for #1 aux blower and #1 engine room blower motor controllers.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Fire Fighting
Issued 26 May 1994
Resolved
Update Fire Control Plan to show correct location of remote emergency stops/shutdowns for ventilation, fuel oil pumps, fuel oil remote operated valves, etc.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Fire Fighting
Issued 26 May 1994
Resolved
Replace ball valve for washdown station at fire station #4. Handle broken off requiring wrench to open/close valve. Washdown station to be secured when not in use to ensure adequate supply of fire main pressure.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Documentation
Issued 9 October 1992
Resolved
PROVIDE COPY OF VESSEL'S NEW CERTIFICATE OF DOCUMENTATION & COFR WITH NEW OPERATOR TO [name withheld].
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Deck/Cargo
Issued 16 June 1992
Resolved
HYDRO OIL TRANSFER HOSE. FAX RESULTS/SERVICING REPORT TO MIO NY.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Engineering
Issued 16 June 1992
Resolved
HYDRO TWO AIR RECEIVERS IN THE PRESENCE OF THE ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Electrical
Issued 16 June 1992
Resolved
REPAIR EMERGENCY LIGHTING IN ENGINE ROOM. LOCATION AFT BULKHEAD IN ENGINE ROOM AND PORT AND STARBOARD ESCAPES FAX RESULTS TO MIO NY.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Deck/Cargo
Issued 16 June 1992
Resolved
REPAIR / REPLACE PORT AFT BULK TANK SAFETY RELIEF VALVE FAX RESULTS TO MIO NY.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Fire Fighting
Issued 16 June 1992
Resolved
REPLACE ONE UL APPROVED 50' FIRE HOSE. FAX RESULTS & INVOICE TO MIO NY.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Construction/Loadline
Issued 14 June 1990
Resolved
REPAIR OR REPLACE OILY WATER SEPARATOR AND PROVE OPERATION.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Documentation
Issued 3 July 1986
Resolved
PROVIDE COPY CERTIFICATE OF FINANCIAL RESPONSIBILITY. COMPLIANCE DATE IS 23 JULY 1986
Condition: Unknown
Due 3 July 1986
Resolved 3 July 1986