Records from 1985 to 1997. Most recent: inspection, 1 April 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
1 April 1997
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1102191
27 June 1996
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 932752
22 March 1996
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394532
8 June 1995
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1367433
25 March 1994
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1167283
27 September 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1153134
23 September 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 643660
7 September 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 829778
23 July 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1158454
8 July 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 212231
12 May 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1149529
6 April 1993
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1147934
28 March 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1258882
10 April 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 931990
30 March 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 904166
4 April 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1225437
14 December 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 905440
30 March 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210063
25 April 1988
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1039485
15 April 1987
Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1009952
25 March 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1297432
3 April 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1290436
Lifesaving
Issued 22 March 1996
Resolved
Vessel found short 3 adult lifejackets. Until replacements are provided on board, passenger allowance is reduced to not more than 26.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Construction/Loadline
Issued 22 March 1996
Resolved
Repair cracks at portside transom well.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Fire Fighting
Issued 22 March 1996
Resolved
Provide onboard operable 5 GPM hand fire pump.
Condition: Unknown
Due 30 March 1996
Resolved 15 May 1996
Lifesaving
Issued 22 March 1996
Resolved
Label ring buoy with vessel's name.
Condition: Unknown
Due 30 March 1996
Resolved 15 May 1996
Accommodation/Occupational Safety
Issued 22 March 1996
Resolved
Reinforce forward rail. Provide plan of reinforcement and evidence of completion.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Electrical
Issued 25 March 1994
Resolved
PROVIDE A COVER FOR THE THROTTLE HANDLE'S WIRING.
Condition: Unknown
Due 4 April 1994
Resolved 19 April 1994
Electrical
Issued 25 March 1994
Resolved
REMOVE UNUSED WIRING UNDER THE HELM STATION.
Condition: Unknown
Due 4 April 1994
Resolved 19 April 1994
Engineering
Issued 25 March 1994
Resolved
PROVIDE A MEANS OF CONTAINMENT FOR PORT AND STARBOARD FUEL TANK VENTS. FUEL TANK MAY BE VENTED WITHIN THE DECK COMBING FOR THE VESSEL TO SATISFY THIS REQUIREMENT.
Condition: Unknown
Due 4 April 1994
Resolved 19 April 1994
Lifesaving
Issued 23 July 1993
Resolved
PROVIDE SATISFACTORY STOWAGE FOR CHILD-SIZE LIFE PRESERVERS. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 August 1993
Resolved 15 August 1993
Lifesaving
Issued 23 July 1993
Resolved
PROVIDE TWO(2) ADDITIONAL CHILD-SIZE TYPE I LIFE PRESERVERS. VESSEL IS _x001C_ NOT ALLOWED TO CARRY MORE THAN ONE(1) CHILD ON BOARD THE VESSEL UNTIL _x001C_ REQUIREMENT IS COMPLETED. _x001C_ _x001C_
Condition: Unknown
Due 15 August 1993
Resolved 15 August 1993
Electrical
Issued 28 March 1992
Resolved
REPAIR THE PORT AND STARBOARD GAS GAUGES.
Condition: Unknown
Due 28 March 1992
Resolved 28 March 1992
Fire Fighting
Issued 28 March 1992
Resolved
PROPERLY SECURE THE PORTABLE EXTINGUISHER ON THE STERN.
Condition: Unknown
Due 28 March 1992
Resolved 28 March 1992
Fire Fighting
Issued 30 March 1989
Resolved
PROVIDE ON BOARD A SUITABLE HAND PORTABLE FIRE/BILGE PUMP CAPABLE OF 5 GPM,WITH SUFFICIENT SUCTION AND DISCHARGE HOSE TO BE ABLE TO DRAW WATER FROM OVER THE SIDE.
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Documentation
Issued 25 March 1986
Resolved
POST A CURRENT COPY OF THE VESSELS CERTIFICATE OF INPECTIONS
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Engineering
Issued 25 March 1986
Resolved
PROVIDE VENTS FOR FUEL OIL TANKS AS PER 46 CFR 182.15-35
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Electrical
Issued 25 March 1986
Resolved
PROVIDE FLASHLIGHT
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Fire Fighting
Issued 25 March 1986
Resolved
PROVIDE 5 GPM HAND FIRE/BILGE PUMP
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Documentation
Issued 25 March 1986
Resolved
POST EMERGENCY CHECKOFF LIST IN A PLACE CONSPICUOUS TO PASSENGERS
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Deck/Cargo
Issued 3 April 1985
Resolved
PROVIDE 28 LB ANCHOR OR ADDITIONAL 13LB ANCHOR.
Condition: Unknown
Due 3 April 1985
Resolved 3 April 1985