MAURY USCG vessel records Sign in
← All vessels

KERRY GROS

KERRY GROS is a 1982 offshore supply vessel. The Coast Guard has recorded 53 inspections since 1982, most recently in August 2015, along with 59 deficiencies and 1 casualty investigation in 2012.

Records from 1982 to 2015. Most recent: inspection, 7 August 2015.

Built
1982
Last inspected
7 August 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8203024 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCX2734
Flag
UNITED STATES
366743090, 367403880, 369814000 (licence lapsed)
Maury page id
psix-54051

Inspections, by type

…with no type recorded10
Years with a record 27 calendar years (1982–2015)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it299 - Regulatory (Subpart C or D), Gross Ton
692 - Convention (Subpart B), Gross Ton
203 - Regulatory (Subpart C or D), Net Ton
207 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE8301MMSI 367403880 · expired · compulsorily equipped · granted 10 April 2009, cancelled 15 June 2019
WDD2499MMSI 369814000 · expired · compulsorily equipped · granted 20 May 2006, cancelled 23 July 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCX2734MMSI 366743090 · cancelled · compulsorily equipped · granted 22 January 1998, cancelled 5 June 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 53

7 August 2015 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5816712
12 August 2011 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4113349
22 July 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3543195
13 November 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3356519
19 March 2008 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3167745
9 March 2008 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3167674
13 September 2007 Hull Examination · Examination of Repairs · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3073828
27 July 2007 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3008930
23 July 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3005208
14 August 2006 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2747290
6 June 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2672149
25 May 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2658786
23 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571374
26 July 2005 Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2435566
28 April 2005 MTSA/ISPS Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2339550
4 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303576
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290098
28 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2230347
2 September 2004 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2184143
23 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972118
2 November 2003 Annual Inspection · Damage Survey
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1938804
2 August 2002 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1655859
29 July 2002 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1654358
5 December 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076981
21 August 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464413
18 January 2001 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 769317
5 January 2001 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1057068
23 October 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472368
9 October 2000 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 41039
9 October 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054661
6 January 2000 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 44505
7 October 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369368
19 February 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129260
17 November 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806002
6 November 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804300
9 October 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467567
17 November 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392809
27 January 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1101207
22 November 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461746
20 October 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765148
19 October 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 190443
14 November 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409386
21 October 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367192
21 October 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470372
23 October 1992 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412446
24 October 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936627
23 October 1990 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919449
25 October 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1327164
22 November 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207186
1 July 1988 MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 894454
30 October 1987 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1308693
9 December 1986 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1022793
21 July 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277045

Deficiency record · 59

Fire Fighting › Means of Escape › Emergency Lighting
Issued 12 August 2011 Resolved
Provide additional emergency lighting in tunnel area forward of engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2011
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 August 2011 Resolved
Provide engine room with cleaning materials so that engineers my clean engine room, engine room has oil/fuel spills every where.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2011
Navigation › Piloting/Steering › Marine Charts
Issued 13 November 2008 Resolved
Update charts....Electronic or Paper and have available all Notice to Mariners for applicable charts.
Due 23 November 2008
Resolved 18 November 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 13 November 2008 Resolved
Maintain Logs IAW 46 CFR. Provided copy of required log entries to Master. Should be review with scutiny next topside inspection. Pre-departure checks, drills, EPirb, Sanitary, etc....
Due 31 December 2009
Resolved 18 September 2009
Resolution: Vsl''s logs correct and up to date.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 November 2008 Resolved
Remove un-approved wiring from bridge console, install iaw subchapter "J"
Due 13 December 2008
Resolved 18 November 2008
Lifesaving › Rescue Boat › Carriage Requirement
Issued 14 August 2006 Resolved
Proivde man overboard/rescue platform (in lieu of rescue boat per D8 policy) & conduct drill prior to sailing.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2006
Resolution: BMS Fourchon fabricated platform and installed on vsl. Satisfactory drill conducted.
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 14 August 2006 Resolved
Provide rescue/man ovbd harness (expired service life) prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2006
Communications › Audible Communications › SPD (Other)
Issued 14 August 2006 Resolved
Repair public address system (inop).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2006
Engineering › Lubricating Oil Service System › Gauge
Issued 14 August 2006 Resolved
Repair inoperative bridge gauges for main engines and firemain.
Condition: Improper/Lack of Maintenance
Due 14 September 2006
Resolved 13 November 2007
Engineering › Fuel Oil Service System › Filter
Issued 14 August 2006 Resolved
Plug fuel filter petcocks on port and stbd main engine.
Condition: Improper/Lack of Maintenance
Due 14 September 2006
Resolved 13 November 2007
Engineering › Fuel Oil Service System › Piping
Issued 14 August 2006 Resolved
Fix leaking fuel filter petcock on port main engine. Repair/Replace leaking fuel return valve overhead of engine room (centerline aft).
Condition: Improper/Lack of Maintenance
Due 14 September 2006
Resolved 13 November 2007
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 2 September 2004 Resolved
PROVIDE APPROVED AUTOMATION TEST PROCEEDURES.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 28 April 2005
Resolution: Sighted.
Engineering › Shafting/Propeller Arrangements
Issued 8 November 2003 Resolved
Complete NDT testing of port and stbd propellers in the presence of an attending USCG Marine Inspector. Any fractures or surface deformations to be permanently repaired IAW applicable ABS rules. LEGACY COMPONENT DESC: Propeller (fixed pitch)
Action required: 705 - Other - as specified
Due 10 November 2003
Resolved 16 November 2003
Resolution: Both port and stbd propellers were replaced under the supervison of the attending ABS surveyor. See class report.
Construction/Loadline › Hull
Issued 8 November 2003 Resolved
Crop and renew hull plate where fractured in way of frame 52, port keel strake. (Min 18"X18" insert). LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 10 November 2003
Resolved 16 November 2003
Resolution: See ABS class report.
Construction/Loadline › Hull
Issued 8 November 2003 Resolved
Permanently repair forward auxiliary sea chest in way of frame 24. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 10 November 2003
Resolved 16 November 2003
Resolution: See ABS class report.
Construction/Loadline › Structures
Issued 8 November 2003 Resolved
Permanently repair tripped deck plate support structure in machinery space. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 10 November 2003
Resolved 16 November 2003
Resolution: See ABS class report.
Construction/Loadline › Hull
Issued 8 November 2003 Resolved
Permanently repair transverse floor insert in way of frame 24, center line in way of forward auxiliary sea chest (100% weldment penetration) LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Due 10 November 2003
Resolved 16 November 2003
Resolution: See ABS class report.
Operations/Management › Pollution › Control of Garbage
Issued 4 November 2003 Resolved
Revise waste management plan required by 33 CFR 151.57 to include the requirements of 33 CFR 151.57(c)(1-3).
Due 9 November 2003
Resolved 5 November 2003
Navigation › Piloting/Steering
Issued 4 November 2003 Resolved
Provide up to date marine charts and nautical publications as required by 46 CFR 97.05-5 for the areas of operation. LEGACY COMPONENT DESC: Marine Charts
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2003
Resolved 5 November 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 November 2003 Resolved
Permanently repair mast head and aft deck anchor lights.
Due 10 November 2003
Resolved 5 November 2003
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 4 November 2003 Resolved
Prove proper operation of rudder angle indicator required by 46 CFR 58.25-25. (Calibrate indicators at main steering and in steering gear compartment to match actual rudder angle).
Action required: 705 - Other - as specified
Due 10 November 2003
Resolved 6 November 2003
Engineering › Steering Gear System › Linkage
Issued 4 November 2003 Resolved
Permanently repair rudder angle indicator feedback linkage on main steering gear. (Remove hose clamps).
Due 10 November 2003
Resolved 6 November 2003
Navigation › Piloting/Steering
Issued 4 November 2003 Resolved
Label each steering station as required by 46 CFR 97.37-35
Due 10 November 2003
Resolved 5 November 2003
Navigation › Piloting/Steering
Issued 4 November 2003 Resolved
Provide instructions for steering gear change over as required by 46 CFR 37.33.
Due 10 November 2003
Resolved 6 November 2003
Communications › Radio Communications
Issued 4 November 2003 Resolved
Service EPIRB and hydrostatic release as required by 46 CFR 199.45. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2003
Resolved 6 November 2003
Accommodation/Occupational Safety › Ventilation
Issued 4 November 2003 Resolved
Clean laundry room dyer exhaust duct.
Due 10 November 2003
Resolved 5 November 2003
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 4 November 2003 Resolved
Remove all vessel stores from crew sleeping accommodations. (46 CFR 92.20-5)
Action required: 705 - Other - as specified
Due 10 November 2003
Resolved 5 November 2003
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 4 November 2003 Resolved
Perform test and inspection of paint locker CO2 portable extinguisher as required by 46 CFR 97.15-60.
Due 10 November 2003
Resolved 5 November 2003
Lifesaving › Line-Throwing Appliances
Issued 4 November 2003 Resolved
Provide 25 cartridges for line throwing appliance, Shoulder Gun Type. (46 CFR 160.031-4(d)
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2003
Resolved 10 November 2003
Lifesaving › Lifebuoys
Issued 4 November 2003 Resolved
Replace batteries in all electric floating lights. (46 CFR 199.190) LEGACY COMPONENT DESC: Self-igniting Lights
Due 10 November 2003
Resolved 5 November 2003
Lifesaving › Lifejacket/PFD (General)
Issued 4 November 2003 Resolved
Post lifejacket donning instructions in all crew accommodations and muster stations. (46 CFR 199.80(c)(5)
Due 10 November 2003
Resolved 5 November 2003
Fire Fighting › Self-contained Breathing Apparatus
Issued 4 November 2003 Resolved
Provide 2 full charges and 2 spare charges for SCBA units. (46 CFR 96.35) (Vessel not currently engaged on an international voyage. Equipment not required, but on board and not in operative condition). LEGACY COMPONENT DESC: Air Bottle, Spare
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2003
Resolved 8 November 2003
Electrical › Electrical Distribution System (service)
Issued 4 November 2003 Resolved
Mark each fuel oil transfer pump remote stopping system switch as required by 46 CFR 111.103-9(b). LEGACY COMPONENT DESC: Switch
Due 10 November 2003
Resolved 6 November 2003
Electrical › Electrical Distribution System (service)
Issued 4 November 2003 Resolved
Install blanks in lighting distribution panel #1 and 440 volt panel in machinery space. LEGACY COMPONENT DESC: Panelboard
Due 10 November 2003
Resolved 6 November 2003
Electrical › Electrical Distribution System (service)
Issued 4 November 2003 Resolved
Provide electrical safety mat behind main switchboard. LEGACY COMPONENT DESC: Switchboard
Due 10 November 2003
Resolved 6 November 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 November 2003 Resolved
Repair/replace stbd propulsion engine tachometer.
Due 10 November 2003
Resolved 8 November 2003
Engineering › Bilge Water Management System
Issued 4 November 2003 Resolved
Provide suitable bilge piping suction strainer in machinery space IAW 46 CFR 50-50(g). LEGACY COMPONENT DESC: Strainer
Due 10 November 2003
Resolved 8 November 2003
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 2 August 2002 Resolved
Mark all unlabeled valves on fuel system.
Due 8 August 2002
Resolved 8 August 2002
Resolution: Marked before the end of the inspection.
Stability › Watertight Integrity
Issued 2 August 2002 Resolved
Make following repairs to watertight doors: a. portside engine room escape inboard top and middle dogs not landing, seal at top center of door. b. starboard side engine room escape inboard top and bottom dogs not land. c. starboard deck locker aft top and bottom dogs. d. portside deck locker LEGACY COMPONENT DESC: doors
Due 8 September 2002
Resolved 6 September 2002
Resolution: Rcvd report attesting to the repairs of watertight doors.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 2 August 2002 Resolved
Eliminate excessive leakage from portside shaft seal, replace packing if necessary. LEGACY COMPONENT DESC: Bearing
Due 8 August 2002
Resolved 8 August 2002
Resolution: Repaired during inspection.
Navigation › Piloting/Steering
Issued 2 August 2002 Resolved
Repair or remove inoperative magnetic compass. LEGACY COMPONENT DESC: Gyro Compass
Due 8 September 2002
Resolved 6 September 2002
Resolution: Rcvd report attesting to the repair of magnetic compass.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 August 2002 Resolved
Place personal eye guards on both wheels on bench grinder. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 8 September 2002
Resolved 6 September 2002
Resolution: Rcvd report attesting to the placement of personal eye guards on both wheels on bench grinder.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 2 August 2002 Resolved
Tighten shaft packing on bow thruster PTO unit. LEGACY COMPONENT DESC: Bearing
Due 8 September 2002
Resolved 6 September 2002
Resolution: Rcvd report attesting to the tighting of shaft packing.
Pollution Prevention/Response › Prevention Equipment
Issued 2 August 2002 Resolved
Provide bilge alarm on navigational light control panel. LEGACY COMPONENT DESC: Bilge Monitor
Due 8 September 2002
Resolved 6 September 2002
Resolution: Rcvd report attesting to the installation of bilge alarm on navigational light control panel.
Engineering › Steering Gear System
Issued 2 August 2002 Resolved
Demonstrate proper operation of pilothouse steering gear console panel visual alarm lights for hydraulic fluid low level and pump overloads.
Due 8 September 2002
Resolved 6 September 2002
Resolution: Rcvd report attesting to the proper operation of pilothouse steering gear console.
Construction/Loadline
Issued 9 October 2000 Resolved
AFFECT TEMPORARY REPAIRS TO PORT SHAFT LOG IWO #3 PORT FUEL TANK. REMOVE ALL FUEL, WASH TANK AND GAS FREE PRIOR TO SAILING. NO CARGO, FUEL OR BALLAST WATER IS TO BE LOADED IN THIS COMPT. VSL TO PROCEED DIRECTLY TO MORGAN CITY FOR PERM. REPAIRS TO THE SATISFACTION OF THE ATTENDING INSP.
Condition: Unknown
Due 9 October 2000
Resolved 9 October 2000
Lifesaving
Issued 7 October 1999 Resolved
DEMONSTRATE COMPLIANCE WITH U.S. COAST GUARD RESCUE BOAT POLICY ON OFFSHIRESUPPLY VESSELS DATED 12NOV98 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 7 October 1999
Resolved 7 October 1999
Engineering
Issued 9 October 1998 Resolved
SUBMIT AUTOMATION TEST PROCEDURES FOR C.G. APPROVAL.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Engineering
Issued 9 October 1998 Resolved
CONDUCT ANNUAL AUTOMATION TEST PROCEDURE INSPECTION.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Lifesaving
Issued 9 October 1998 Resolved
UPDATE FIRE AND SAFETY PLAN.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Lifesaving
Issued 17 November 1997 Resolved
EXP DATE MISSING FROM HYDROSTATIC RELEASE.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Construction/Loadline
Issued 17 November 1997 Resolved
FOREPEAK SUCTION VALVE INOP.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Electrical
Issued 17 November 1997 Resolved
PILOT HOUSE CIRCUIT BREAKER PANEL MISSING LEGEND.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Lifesaving
Issued 17 November 1997 Resolved
RELOCATE LIFERING CURRENTLY OUTSIDE GALLEY DOOR TO A MORE ACCESSABLE LOCATION.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Documentation
Issued 17 November 1997 Resolved
PROVIDE BLOCK DIAGRAM FOR OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Construction/Loadline
Issued 17 November 1997 Resolved
REPAIR INOP DOGS ON PORT SIDE WX TIGHT DOOR IN WHEELHOUSE.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Fire Fighting
Issued 17 November 1997 Resolved
REPAIR BROKEN FIRE PUMP PRESSURE GAUGE IN WHEEL HOUSE.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Electrical
Issued 17 November 1997 Resolved
REPAIR INOP PORT SIDE EMBARKATION LIGHT.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Electrical
Issued 17 November 1997 Resolved
REPAIR INOP BUNK LIGHTS.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997

Casualty record · 1

26 October 2012Routine · role: Involved in a Marine Casualty · activity 4474265
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record