MISS HOSPITALITY

MISS HOSPITALITY is a 1981 passenger vessel (uninspected). The Coast Guard has recorded 12 inspections since 2016, most recently in February 2021, along with 27 deficiencies.

Records from 2016 to 2021. Most recent: inspection, 10 February 2021.

Built
1981
Last inspected
10 February 2021
Documentation
No Operation - PM · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 February 2021
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC9606
Flag
UNITED STATES
Maury page id
psix-54053

Documentation record

Registered dimensions (L × B × D)47.1 ft × 15.0 ft × 5.6 ft
Registered tonnagegross 29 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLIAM T HOLLAND · BILOXI MS, UNITED STATES · built 1981
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBILOXI, MS
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Regulatory (Subpart C or D), Gross Ton
20 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

10 February 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7138526
15 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7007295
12 April 2019 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6661108
16 January 2019 Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611407
9 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6413998
19 March 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6374383
19 April 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6128580
17 February 2017 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6090565
17 January 2017 Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6072032
19 April 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5857520
5 April 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5850082
14 March 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5833198

Deficiency record · 27

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 April 2019 Resolved
Vessel only had 10 distress signals. Vessel is required to have 12 distress signals. Provide 02 additional distress signals.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2019
Resolved 26 April 2019
Resolution: Owner provided photographs of 02 new distress signals
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 April 2019 Resolved
Anchor light was inoperable. Ensure anchor light is properly functioning.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2019
Resolved 26 April 2019
Resolution: Owner provided photograph of properly functioning anchor light
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 April 2019 Resolved
Port main shaft seal is leaking significant amounts of water. Tighten shaft packing to ensure water entry is only a controlled drip.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2019
Resolved 24 April 2019
Resolution: Owner tightened shaft seal to limit water entry into vessel
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 April 2019 Resolved
When pre-engineered fire extinguishing system was tested, port main engine did not shutdown. Ensure all engines shutdown when system is activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 2 May 2019
Resolution: Tested pre-engineered fire extinguishing system, all engines shutdown correctly and restarted in override.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 April 2019 Resolved
Retroflective tape on lifefloat was worn. Renew retroflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 2 May 2019
Resolution: Worn retroflective tape was replaced on lifefloat
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 24 April 2019 Resolved
Vessel did not have letter for proof of enrollment in drug consortium program. Provide letter for proof of enrollment
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 2 May 2019
Resolution: Owner provided letter showing proof of enrollment for vessel with names of all crewmembers
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 April 2019 Resolved
Ammonia inhalants, eyewash, and burn gel were expired. Provide in-date replacements for all expired first aid items.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 2 May 2019
Resolution: Owner provided in date replacements for all expired first aid items
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 January 2019 Resolved
Scheduled Hull Exam beyond drop dead date. Vessel cannot operate between drop dead date and Hull Exam completion
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 28 February 2019
Resolution: Completed satisfactory hull exam
Documentation › Certificates/Documents › FCC SSL
Issued 18 April 2018 Resolved
Provide a updated FCC Station License
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 9 May 2018
Resolution: Provided Cert.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 March 2017 Resolved
Bilge pump light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 19 April 2017
Resolution: Bilge pump lights work properly.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 March 2017 Resolved
Floating waterlight batteries are expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 19 April 2017
Resolution: New battery purchased and tested.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 15 March 2017 Resolved
Portable extinguisher bracket at ops station missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 19 April 2017
Resolution: New bracket installed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 March 2016 Resolved
Child PFD snap clip was broken. Replace with a PFD in serviceable condition IAW 46 CFR180.71 (b). NOTE: Child passenger count reduced to two children until replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Replaced child sized life jacket.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 March 2016 Resolved
Lens covers on port and starboard running lights are foggy/ obstructed. Clean or replace lens to provide proper visibility IAW 46 CFR 183.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Replaced nav lights.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 March 2016 Resolved
Vessel did not have means to conduct alcohol testing within 2 hours. Provide means of testing IAW 46 CFR 4.06-3(a)(i).
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Purchased new, valid alcohol testing devices.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 21 March 2016 Resolved
Vessel did not possess record of training or education for EAP program. Provide hotline and training with documentation IAW 46 CFR 16.401.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 19 April 2016
Resolution: Master provided documentation of training and EAP material
Operations/Management › Equipment Service/Testing › EPIRB
Issued 21 March 2016 Resolved
EPIRB tests were not logged. Conduct monthly tests and log IAW 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Logged completion of required monthly EPIRB test.
Navigation › Piloting/Steering › Marine Charts
Issued 21 March 2016 Resolved
Vessel did not have current charts or publications for route. Provide current copy or currently corrected charts and new publications IAW 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Purchased current and updated charts and publications.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 21 March 2016 Resolved
Emergency exit not properly labeled. Label escape hatches and exits IAW 46 CFR 185.606.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Labled emergency exit.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 March 2016 Resolved
Water light battery expired. Provide approved battery IAW 46 CFR 185.726.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Purchased new batteries for water lights.
Engineering › Bilge Water Management System › Pump
Issued 21 March 2016 Resolved
Bilge pump float switch in starboard accommodation space was inoperable. Provide operational bilge pump IAW 46 CFR 182.520 (e).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Replaced inoperable float switch.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 March 2016 Resolved
Remove disconnected hose from engine room aft port bulkhead. Make bulkhead watertight IAW 46 CFR 179.320 (c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Bulkhead made watertight.
Electrical › Electric Supply System (service) › Cable
Issued 21 March 2016 Resolved
Unused cable in stbd fwd bulkhead. Remove or cap off unused cables IAW 46 CFR 183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Removed unused cable.
Electrical › Lighting (service) › Outlet Box
Issued 21 March 2016 Resolved
Properly mount shore tie box and make lights operable or remove them to make safe IAW 46 CFR 176.830.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Box properly mounted.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 March 2016 Resolved
Generator not properly mounted; guard missing. Properly mount generator and install guard to make safe IAW 46 CFR 176.830.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Guard installed on generator.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 March 2016 Resolved
Vessel not equipped with DSC enabled VHF radio. Provide operable DSC VHF radio IAW 46 CFR 184.502.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Installed new VHF radio that is DSC enabled.
Navigation › Collision/Grounding Avoidance › Radar
Issued 21 March 2016 Resolved
Radar installed and inoperable. Remove radar or make operable IAW 46 CFR 176.816.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 5 April 2016
Resolution: Removed old radar from vessel.