MAURY USCG vessel records Sign in
← All vessels

EAGLE

EAGLE is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 45 inspections since 1982, most recently in March 1996, along with 123 deficiencies.

Records from 1982 to 1996. Most recent: inspection, 22 March 1996.

Built
1982
Last inspected
22 March 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAN2728
Flag
UNITED STATES
—
Maury page id
psix-54055

Inspections, by type

…with no type recorded11
Years with a record 13 calendar years (1982–1996)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it7584 - Regulatory (Subpart C or D), Gross Ton
7584 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WAN2728MMSI not assigned · expired · compulsorily equipped · granted 16 May 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PACIFIC LANCE Towing Vessel · MISLE 227060 · 5 January 1994 · activity 63022

Inspection history · 45

22 March 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 884873
15 November 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1184501
27 September 1995 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363390
14 February 1995 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 841920
19 January 1995 Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 175624
11 January 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1469115
7 December 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1139948
24 July 1994 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359959
5 January 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 63022
19 December 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1159724
29 November 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1158223
29 September 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1154788
12 August 1993 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1152912
30 July 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 932319
23 March 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1010756
17 August 1991 Deficiency Check · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 936374
12 August 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1246342
17 June 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347291
10 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903298
9 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924450
18 December 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1213045
6 August 1990 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 926516
1 May 1990 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1238014
30 April 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929907
12 April 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923411
6 February 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 910730
3 November 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1018302
3 November 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1316788
27 September 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1003099
25 August 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203549
28 March 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1207435
27 March 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1202629
27 December 1988 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040522
28 October 1988 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1042571
7 October 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1198478
20 July 1988 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1340053
16 March 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971948
7 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321080
5 November 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332724
23 October 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017273
27 August 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320261
28 August 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004605
25 July 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294247
27 July 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301584
31 July 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274268

Deficiency record · 123

Lifesaving
Issued 27 September 1995 Resolved
REMOVE THE TEMPORARY PATCH AND COVERING FROM THE TOP DRIVE POWER AND CONTROL CABLE FOR FURTHER EXAMINATION AND MODIFY THE LONG CABLE TO PREVENT ANY FURTHER CONTACT.
Condition: Unknown
Due 14 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 27 September 1995 Resolved
REPAIR TANK TOP AND SIDE SHELL DAMAGE, PORT PONTOON, OUTBOARD TOP CORNER BETWEEN FRAMES 31 TO 34.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Lifesaving
Issued 27 September 1995 Resolved
HAVE ANNUAL SERVICING PERFORMED ON LIFE RAFT #3.
Condition: Unknown
Due 14 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 27 September 1995 Resolved
HYDROSTATICALLY TEST SELF CONTAINED BREATHING APPARATUS BOTTLE, OVERDUE FORHYDROSTATIC TEST.
Condition: Unknown
Due 27 September 1995
Resolved 6 October 1995
Accommodation/Occupational Safety
Issued 27 September 1995 Resolved
CLEAN EXCESSIVE GREASE BUILD UP FROM GALLEY HOOD VENTILATION EXHAUST.
Condition: Unknown
Due 4 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 27 September 1995 Resolved
PROPERLY INSTALL ALL CABLE RUNS IN THE UNDER DECK BOX GIRDERS, REMOVING THEM FROM THE DECK IN ACCORDANCE WITH IEEE 45.
Condition: Unknown
Due 31 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 27 September 1995 Resolved
MAKE PERMANENT REPAIRS TO THE FIRE MAIN BY REMOVING THE MUD RETURN LINE SYSTEM FLUSH LINE (UPPER SHALE SHAKER) FROM THE FIRE MAIN; PROVIDE HANGERS TO THE SECTION OF PIPE ON THE PORT AFT SIDE WHICH IS INADEQUATELY SUPPORTED; REORIENT FIRE STATION #3 VALVE FROM THE UPSIDE DOWN POSITION.
Condition: Unknown
Due 31 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 27 September 1995 Resolved
CALIBRATE ALL LEL AND H2S SENSORS, EXCEPT SENSORS #9 & #10, AND TEST IN THEPRESENCE OF A COAST GUARD INSPECTOR OR ABS SURVEYOR.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Fire Fighting
Issued 27 September 1995 Resolved
REPLACE AUXILIARY PUMP ROOM FIXED HALON PIPING HEAD DIFFUSERS.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Electrical
Issued 27 September 1995 Resolved
DETERMINE CAUSE FOR THE LOW ELECTROLYTE READING FOR THE OBSTRUCTION LIGHTS EMERGENCY BATTERIES.
Condition: Unknown
Due 14 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 27 September 1995 Resolved
PROVIDE NEW DOOR LATCH FOR THE GAS TIGHT DOOR BETWEEN THE MUD PITS AND THE SACK STORAGE AREA.
Condition: Unknown
Due 14 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 27 September 1995 Resolved
REPAIR DECK HOUSE PORT LIGHT SPRAY COOLING PIPING WHERE IT IS HOLED.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Documentation
Issued 27 September 1995 Resolved
PROVIDE THE HULL GAUGING REPORT. PROVIDE ABS CARGO GEAR REPORT ON THE STARBOARD CRANE WEIGHT TEST. PROVIDE FIRE FIGHTING SERVICING REPORT.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Construction/Loadline
Issued 27 September 1995 Resolved
MAKE PERMANENT REPAIRS TO BOTH PUMP ROOM PRIMARY FIXED BILGE SYSTEMS BY PROVIDING NEW CHECK VALVES AND SUCTION PIPE FOR THE PUMP ROOM ROSE BOXES.
Condition: Unknown
Due 31 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 27 September 1995 Resolved
REORIENT FIRE STATIONS #1 & #2 HANDLES TO THE HORIZONTAL OR TOP POSITION.
Condition: Unknown
Due 31 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 27 September 1995 Resolved
MAKE PERMANENT REPAIRS TO THE DRILL FLOOR CABLE RUNS THAT ARE IMPROPERLY SECURED WITH PLASTIC STRAPS. PROPERLY SECURE CABLES IN ACCORDANCE WITH IEEE45. REMOVE ALL UNUSED CONTRACTOR'S CABLES.
Condition: Unknown
Due 31 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 27 September 1995 Resolved
REPLACE TWO DAMAGED FLEXIBLE HOSES ON THE FIXED HALON FIREFIGHTING SYSTEM FROM THE MAIN BOTTLES TO THE TIME DELAY BOTTLES.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Lifesaving
Issued 27 September 1995 Resolved
MAKE PERMANENT REPAIRS AND PROVE SATISFACTORY OPERATION OF THE PURGE AIR SYSTEM AIR LINE TO THE TV MONITOR AT THE MONKEY BOARD.
Condition: Unknown
Due 14 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 27 September 1995 Resolved
REMOVE GALLEY FIXED FIREFIGHTING SYSTEM PROPELLANT BOTTLE FOR HYDROSTATIC TEST OR REPLACE.
Condition: Unknown
Due 14 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 27 September 1995 Resolved
HAVE RADIOTELEPHONE COMMUNICATION EQUIPMENT SERVICED AS REQUIRED BY IMO CODE.
Condition: Unknown
Due 14 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 27 September 1995 Resolved
REPLACE AND RETEST DEFECTIVE SMOKE DETECTION SENSORS FOR THE LOWER LEVEL PORT SIDE ACCOMODATIONS SPACE (ZONE 4) AND THE ELECTRICIAN'S STOREROOM (ZONE 9).
Condition: Unknown
Due 27 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 27 September 1995 Resolved
REPLACE HALON CONTROL VALVE CABLE CONDUIT HANGER BRACKETS.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Engineering
Issued 27 September 1995 Resolved
PROVIDE FLAME SHIELDS FOR THE RACOR FUEL FILTERS FOR #2 & #3 GENERATORS.
Condition: Unknown
Due 27 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 27 September 1995 Resolved
MAKE PERMANENT REPAIRS TO THE LEAK IN THE COOLING WATER LINE TO THE TOP DRIVE HYDRAULIC UNIT AND IN WAY OF THE SOFT PATCH ON THE COOLING WATER LINETO THE GENERATOR HEAT EXCHANGERS.
Condition: Unknown
Due 27 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 27 September 1995 Resolved
PROVIDE TWO SMOKE SIGNALS, ONE FOR EACH REQUIRED LIFE RING WITH SMOKE.
Condition: Unknown
Due 27 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 27 September 1995 Resolved
REMOVE UNAUTHORIZED CABLE SPLICE IN SHALE SHAKER AREA.
Condition: Unknown
Due 27 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 27 September 1995 Resolved
REMOVE WASTED DOUBLER PLATE AND PROPERLY REPAIR ANCHOR SPURLING TUBES IN ALL COLUMN CHAIN LOCKERS.
Condition: Unknown
Due 31 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 24 July 1994 Resolved
PROVIDE FOR EXAMINATION A COPY OF THE VESSEL'S APPROVED HAZARDOUS LOCATION PLAN TO THE SATISFACTION OF THE COGNIZENT OCMI.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Fire Fighting
Issued 24 July 1994 Resolved
CONDUCT FOAM ANALYSIS FOR THE HELO DECK FIXED FOAM SYSTEM AND PROVIDE A COPY TO [name withheld].
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Lifesaving
Issued 24 July 1994 Resolved
Obtain suitable calibration gas for the combustible gas detector system andcalibrate the system to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Lifesaving
Issued 24 July 1994 Resolved
Conduct annual servicing of liferaft which was last serviced 28 Oct 93 and provide a copy of the servicing report to [name withheld].
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Lifesaving
Issued 24 July 1994 Resolved
RENEW THE WIREROPE FOR BOTH LIFERAFT DAVITS AND CONDUCT THE REQUIRED WEIGHT TEST FOR BOTH DAVITS AS PER 46CFR107.239(b) UPON COMPLETION OF THE FALLS RENEWAL TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Deck/Cargo
Issued 24 July 1994 Resolved
Install over pressure protection devices (rupture disk or relief valve) that does not exceed the designed MAWP for all tensioner pressure vessels. Note: Rupture disks must meet requirments of 46 CFR 54.15-13(b)(1-3).
Condition: Unknown
Due 31 October 1994
Resolved 20 October 1994
Electrical
Issued 24 July 1994 Resolved
Renew the electrical junction box located over the wire run at the aft center end of the mud pit area to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Fire Fighting
Issued 24 July 1994 Resolved
CONDUCT ANNUAL SERVICING OF ALL FIRE EXTINGUISHERS WHICH ARE CURRENTLY OVERDUE FOR SERVICING AND PROVIDE A COPY OF THE SERVICE REPORT TO [name withheld] REPORT SHOULD INCLUDE DATE, SERIAL #, LOCATION, WEIGHT, AND LAST HYDRO DATE._x001C_
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Accommodation/Occupational Safety
Issued 24 July 1994 Resolved
Install an auto door closer for the stairtower fire door adjacent to laundry and install a door knob for the fire door adjacent to the change room to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Documentation
Issued 24 July 1994 Resolved
Obtain a Safety Radiotelephony certificate and provide a copy to the cognizent OCMI.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Electrical
Issued 24 July 1994 Resolved
Replace existing welding connection on the drill floor (aft bulkhead) with one that meets requirements for a Class I, Division II hazardous location or remove the connection to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Engineering
Issued 24 July 1994 Resolved
Install and prove the operation of the high jacket water temperature alarm for #3 generator to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 31 October 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 24 July 1994 Resolved
MAKE PERMENANT REPAIRS TO ALL WASTED KICKTUBES IN WAY OF EACH OF THE FOUR ANCHOR WINDLASSES TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Lifesaving
Issued 24 July 1994 Resolved
INSTALL PROTECTIVE CAGES AROUND BOTH FIXED VERTICAL LADDERS SERVING AS EMBARKATION AIDS FOR EACH LIFEBOAT AS PER 46 CFR 108.525(e) TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 31 August 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 24 July 1994 Resolved
RENEW THE GASKET FOR THE WATERTIGHT DOOR TO THE FWD STOREROOM IN COLUMN #4 TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Lifesaving
Issued 24 July 1994 Resolved
CONDUCT ANNUAL SERVICING/ OR RENEW THE PORTABLE FIRE EXTINGUISHERS FOR BOTHLIFEBOATS AND PROVIDE A COPY OF THE SERVICE REPORT TO [name withheld].
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Fire Fighting
Issued 24 July 1994 Resolved
Service the ANSUL galley fire extinguishing system to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Lifesaving
Issued 24 July 1994 Resolved
Renew the rescue boat repair kit glue to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Fire Fighting
Issued 24 July 1994 Resolved
Install a check valve in the firemain so that the emergency fire pump cannot "motor over" the main firepump when operating the emergency fire pump only and demonstrate operation to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Lifesaving
Issued 24 July 1994 Resolved
Obtain enough provisions for 4 more people and install in #2 lifeboat to the satisfaction of the attending Coast Guard marine inspector.
Condition: Unknown
Due 24 July 1994
Resolved 24 July 1994
Documentation
Issued 19 December 1993 Resolved
PROVIDE [name withheld] WITH THE DIVERS UNDERWATER HULL REPORT, HALON BOTTLESSERVICING REPORT, AND LIFEBOAT REPAIR REPORT.
Condition: Unknown
Due 19 January 1994
Resolved 20 January 1994
Fire Fighting
Issued 12 August 1993 Resolved
CONDUCT REQUIRED HYDROSTATIC TESTING OF ALL FIXED FIRE EXTINGUISHING SYSTEMPRESSURE VESSELS, ALL LIFEBOAT BREATHING AIR SYSTEM PRESSURE VESSELS, AND PORTABLE FIRE EXTINGUISHERS AT AN APPROVED DOT TESTING FACILITY.
Condition: Unknown
Due 12 August 1993
Resolved 12 August 1993
Lifesaving
Issued 12 August 1993 Resolved
CONDUCT REQUIRED ANNUAL SERVICING FOR INFLATABLE LIFERAFT NO. 3 (LAST DONE JUN 92) AND SERVICE OR RENEW HYDROSTATIC RELEASES FOR LIFERAFTS NO. 1 AND NO. 4 IAW 46 CFR 107.231(b).
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Lifesaving
Issued 12 August 1993 Resolved
REPAIR GEL COAT IN WAY OF OSMOSIS BLISTERS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS FOR LIFEBOATS NO. 1 AND NO. 2. REPAIRS TO BECOMPLETED TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 12 August 1993
Resolved 12 August 1993
Lifesaving
Issued 12 August 1993 Resolved
CONDUCT WEIGHT TEST FOR LIFEBOAT NO. 2 (FALLS RENEWED) IAW 46 CFR 107.231(b).
Condition: Unknown
Due 12 August 1993
Resolved 12 August 1993
Documentation
Issued 17 August 1991 Resolved
SUBMIT TO [name withheld] A REVISED OPERATIONS MANUAL WHICH INCORPORATES REMOVAL OF AUXILIARY BOILERS AND ADDITION OF HELO DECK FUELING SYSTEM, TOP DRIVE SYSTEM AND DERICK EXTENSION. ENSURE STABILITY DATA IS UPDATED FOR THESE CHANGES.
Condition: Unknown
Due 17 August 1991
Resolved 17 August 1991
Fire Fighting
Issued 17 August 1991 Resolved
AMMEND SAFETY PLAN TO CONTAIN HELO DECK FOAM SYSTEM AND SUBMIT TO [name withheld].
Condition: Unknown
Due 17 August 1991
Resolved 17 August 1991
Engineering
Issued 6 August 1990 Resolved
HYDROSTATICALLY TEST AIR RECEIVER FOR DRILL RIG FLOOR PRIOR TO SERVICE.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Electrical
Issued 6 August 1990 Resolved
REPLACE GLOBE ON LIGHT IN ENGINE ROOM IN FRONT OF # 2 ENGINE.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Lifesaving
Issued 6 August 1990 Resolved
CONDUCT FIRE AND LIFE BOAT DRILL UPON ARRIVAL OF THE CREW.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Fire Fighting
Issued 6 August 1990 Resolved
SERVICE OR REMOVE THE 100 LB. CO2 SYSTEM IN THE STORE ROOM UNDER THE STARBOARD CRANE (OLD PAINT LOCKER).
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Lifesaving
Issued 25 August 1989 Resolved
PROVIDE ONE 25 PERSON LIFERAFT (DAVIT LAUNCH) FOR STATION #3 VESSELS MANNING IS REDUCED TO 175 PERSONS TOTAL UNTIL ALL FOUR RAFTS ARE ABOARD.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Navigation
Issued 25 August 1989 Resolved
REPAIR TOP RED RESTRICTED IN ABILITY TO MANEUVER LIGHT.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Deck/Cargo
Issued 25 August 1989 Resolved
RENEW STARBOARD CRANE BOOM TIP EXTENSION WHIP (FAST) LINE ON STARBOARD CRANE CANNOT BE USED UNTIL EXTENSION IS RENEWED AND PROERLY TESTED AND WITNESSED BY AN APPROVED AGENCY.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Construction/Loadline
Issued 25 August 1989 Resolved
REPAIR KING GUAGES FOR TANKS PT-3 AND ST-3.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Electrical
Issued 25 August 1989 Resolved
REPAIR/RENEW THE WASTED KICK PIPES DECK ELECTRICAL PENETRATIONS ON THE PORTSIDE AFT OF MEZZANINE LEVEL BY THE PUMPS AND LADDER.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Construction/Loadline
Issued 25 August 1989 Resolved
UNPLUG SOUNDING TUBES FOR #7 PORT AND STARBOARD TANKS.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Construction/Loadline
Issued 25 August 1989 Resolved
REPAIR/RENEW PORT OVERBOARD DISCHARGE AUTOMATIC REMOTE CONTROL VALVE. VALVE DOESN'T FULLY CLOSE.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Navigation
Issued 25 August 1989 Resolved
REPAIR STARBOARD STEERING CONTROL IN FOLLOW UP MODE WHILE USING #2 STEERINGPUMP OR PRIOR TO THE NEXT RIG MOVE WHICH EVER OCCURS FIRST.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Accommodation/Occupational Safety
Issued 25 August 1989 Resolved
RENEW THE EMERGENCY GENERATOR VENT SHUTDOWN SWITCH SO THAT IT SHUTS DOWN PROPERLY WHEN THE GLASS IS BROKEN.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Electrical
Issued 25 August 1989 Resolved
INSTALL AND POUR EYS FITTING ON ALL OF THE AIR PURGED CABLE CONNECTORS ON THE DRILL FLOOR OR INSTALL LOSS OF PURGE INDICATOR EITHER AUDIBLE OR VISUALON EACH CABLE CONNECTION.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Electrical
Issued 25 August 1989 Resolved
RENEW THE TYPE SO CABLE ON THE SWACO MUD CLEANER UNIT IN THE MUD PIT SHALE SHAKER AREA WITH APPROVED CABLE.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Electrical
Issued 25 August 1989 Resolved
RENEW THE WINCH CONTROL ON THE MEZZANINE LEVEL PORT SIDE WITH A CONTROLLER APPROVED FOR HAZARDOUS LOCATIONS OR RELOCATE THE CONTROLLER IN A NON HAZAROUS AREA.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Electrical
Issued 25 August 1989 Resolved
MOUNT AND POUR EYS FITTINGS ON JUNCTION BOX ON PORT SIDE MEZZANINE LEVEL FORWARD
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Lifesaving
Issued 25 August 1989 Resolved
PROVIDE ONE RED HANDHELD FLARE FOR #1 LIFEBOAT TO MAKE A TOTAL OF TWELVE. ONE FLARE WITH NO MANUFACTURE DATE OR EXPIRATION DATE.
Condition: Unknown
Due 25 August 1989
Resolved 25 August 1989
Electrical
Issued 27 December 1988 Resolved
PROVIDE VISUAL OR AUDIBLE ALARM FOR DRILLERS CONSOLE LOCATED ON DRILL FLOOR IN ACCORDANCE WITH NFPA 496. VISUALLY CHECK PURGE AND LOG EVERY 30 MINUTES UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Electrical
Issued 27 December 1988 Resolved
PROVIDE VISUAL OR AUDIBLE ALARM FOR SUBSEA MONITOR LOCATED ON DRILL FLOOR IN ACCORDANCE WITH NFPA 496. VISUALLY CHECK PURGE AND LOG EVERY 30 MINUTES UNTIL REPAIRS ARE MADE.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Electrical
Issued 27 December 1988 Resolved
PROVIDE VISUAL OR AUDIBLE ALARM FOR STATAGRAPH CRT DRILL MONITOR IN ACCORDANCE WITH NFPA 496, LOCATED AT DRILLERS STATION. VISUALLY CHECK PURGEAND LOG EVERY 30 MINUTES UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Electrical
Issued 20 July 1988 Resolved
CONDUCT THE TEST ON THE EMERGENCY BATTERIES REQUIRED BY 46 CFR 109.211
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Lifesaving
Issued 20 July 1988 Resolved
PROVIDE A CERTIFICATE SIGNED BY A COAST GUARD MARINE INSPECTOR FOR THE RAFT SERVICED IN BRAZIL SER# 12 LOT 27 AT LIFE RAFT STATION #2 SERVICED IN BRAZIL 06 JAN 88. 46 CFR 160.051-6 (A) & (E) (2) OR RESERVICE RAFT.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Fire Fighting
Issued 20 July 1988 Resolved
PROVIDE THE FOAM SAMPLE TEST RESULTS REQUIRED BY 46 CFR 107.235 (B)(2)(III)
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Lifesaving
Issued 20 July 1988 Resolved
REPLACE WINDOWS AROUND COXSWAIN STAND ON BOATS 1 AND 2 AS NECESSARY.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Fire Fighting
Issued 20 July 1988 Resolved
REPLACE THE NECK DOWN FLANGE & PIPE FROM THE #2 PUMP IN THE FIRE MAIN SYSTEM PIPING TO REMOVE THE DOUBLER FROM THE SYSTEM.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Electrical
Issued 20 July 1988 Resolved
PROPERLY MOUNT FLOURESCENT LIGHT FIXTURE LOCATED IN MUD PIT ROOM. LIGHT PRESENTLY SUPPORTED BY LENGTH OF STRING.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Electrical
Issued 20 July 1988 Resolved
REMOVE SJO TYPE NEOPRENE COATED ELECTRICAL CABLE LOCATED IN MUD PIT ROOM.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Electrical
Issued 20 July 1988 Resolved
PROPERLY SUPPORT WIRING TO THE AFT CENTER LINE MUD AGITATOR IN MUD PIT.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Construction/Loadline
Issued 20 July 1988 Resolved
PROVIDE THE [name withheld] A PROPOSAL TO REPAIR THE TEMPORARY DAMAGE IN THE PORT #3 COLUMN IN ACCORDANCE WITH THE CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Navigation
Issued 20 July 1988 Resolved
CORRECT FOG HORN TO SOUND ARTIFICIAL ISLAND AND SOUND SIGNAL. 33 CFR 67.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Lifesaving
Issued 20 July 1988 Resolved
SERVICE RELEASING HOOKS ON DAVIT LAUNCHED LIFE RAFTS. PROVIDE SERVICE CERTIFICATE.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Lifesaving
Issued 20 July 1988 Resolved
REPAINT BOTH # 1 & 2 MOTOR LIFE BOATS INTERNATIONAL ORANGE AS PER 46 CFR 108.503 (C).
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Navigation
Issued 27 August 1987 Resolved
REPAIR OBSTRUCTION LIGHTS ON STARBOARD SIDE.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Lifesaving
Issued 27 August 1987 Resolved
PROVIDE CG-APPROVED HAND HELD PARACHUTE FLARES FOR RIG.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Electrical
Issued 27 August 1987 Resolved
PROPERLY SUPPORT THE ELECTRICAL CABLE RUN FROM THE 480 VOLT PORTABLE GENERATOR, PIPE RACK DECK, TO MOON POOL AREA. SECURE GENERATOR IN PLACE
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Deck/Cargo
Issued 27 August 1987 Resolved
PROVIDE REFUELING HOSES FOR BOTH CRANES THAT IS MARKED FOR OIL SERVICE.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Accommodation/Occupational Safety
Issued 27 August 1987 Resolved
MAKE OPERATIONAL THE MARINE SANITATION DEVICE
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Electrical
Issued 27 August 1987 Resolved
MAKE OPERATIONAL THE REVERSE POWER RELAY ON #3 EMD
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Deck/Cargo
Issued 27 August 1987 Resolved
TIGHTEN ALL LOOSE DERRICK FOUNDATION BOLTS
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Lifesaving
Issued 27 August 1987 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Lifesaving
Issued 27 August 1987 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Lifesaving
Issued 27 August 1987 Resolved
PROVIDE INTERIOR LIGHTING IN BORH LIFEBOATS. CLEAN OR REPLACE THE HELMSMAN WNDOWS IN BOTH BOATS.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Lifesaving
Issued 27 August 1987 Resolved
REPAIR OR REPLACE DAVIT LAUNCH LIFE RAFT RELEASE HOOKS ON BOTH DAVITS
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Lifesaving
Issued 27 August 1987 Resolved
REINSTALL THE NO.4 LIFERAFT.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Lifesaving
Issued 27 August 1987 Resolved
SERVICE INFLATABLE LIFERAFTS NO.1 & NO.3
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Lifesaving
Issued 27 August 1987 Resolved
SUBMIT FOR APPROVAL THE USE OF JACOBS LADDERS AS A MEANS AT DISEMBARKATION AND PROVIDE USCG APPROVED LADDERS.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Lifesaving
Issued 27 August 1987 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Fire Fighting
Issued 27 August 1987 Resolved
HYDROSTATICALLY TEST THE FOUR (4) SELF CONTAINED BREATHING APPARATUS BOTTLEWHICH HAVE NOT BEEN TESTED IN LAST 5 YEARS
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Fire Fighting
Issued 27 August 1987 Resolved
PROVIDE LIFELINE FOR THE FIREMANS OUTFIT LOCATE NEAR BALLAST CONTROL ROOM.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Accommodation/Occupational Safety
Issued 27 August 1987 Resolved
PROVIDE NECESSARY LEG AND ARM SPLINTS, AND 7 TRIANGULAR BANDAGES FOR THE FIRST AID KIT.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Electrical
Issued 27 August 1987 Resolved
CORRECT THE FOLLOWING ITEMS ON THE DRILL FLOOR; (1)PROPERLY TERMINATE OR REMOVE DEAD END WIRES LOCATED BETWEEN DRAW WORKS AND FORWARD WIND SCREEN, (2)MAKE OPERATIONAL THE PURGE ALARM ON THE DRILLERS CONSOLE(3)REMOVE TEST/ MONITORING FROM THE DRILL FLOOR NOT SUITABLE FOR A HAZARDOUS LOCATION.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Electrical
Issued 27 August 1987 Resolved
CORRECT THE FOLLOWING ITEMS IN THE MUD PIT AREA;(1)PROVIDE AND EYS FITTING ON THE MUD MOTOR CONTROLLER,(2)PLUG OR PROPERLY PACK AS NECESSARY ALL STUF-FING TUBES PIERCING THE AUX. MACHINERY BULKHEAD.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Fire Fighting
Issued 27 August 1987 Resolved
CORRECT THE FOLLOWING ITEMS IN THE HALON EXTINGUISHER STORAGE ROOM;(1)TIGH-TEN ALL EYS TYPE FITTING ON THE KIDDIE SWITCH BOXES AND PROPERLY PLUG AS NECESSARY, (2)TIGHTEN TRIGGER LINE FROM SCR/BALLAST HALON PIPING TO TRIGGERBOTTLE,(3)REMOVE PIPE LAYING ON TOP OF HALON ROOM & CHECK BENT TUBING.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Electrical
Issued 27 August 1987 Resolved
PROPERLY BLOCK ALL EMERGENCY BATTERIES IN TRAYS AND RACK. LINE ALL BATTERY BOXES WITH LEAD.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Accommodation/Occupational Safety
Issued 27 August 1987 Resolved
PROVIDE ASME RELIEF VALVES ON THE POTABLE WATER AND SANITARY WATER CUSHION TANKS .
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Engineering
Issued 27 August 1987 Resolved
PROVIDE ASME VALVE ON THE RIG FLOOR AIR RECEIVER. CURRENT RELIEF VALVE IS NOT RATED (SET PRESSURE)
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Construction/Loadline
Issued 25 July 1986 Resolved
(REQ 11 CONT.) OF REPAIRS (IF ANY) THAT MAY NEED TO BE COMPLETED. THIS REQUIREMENT ISSUED TO TEST WATER-TIGHT INTEGRITY OF COLUMN. COLUMN FOUND TO HAVE 2' OF WATER INSIDE.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Accommodation/Occupational Safety
Issued 25 July 1986 Resolved
PROVIDE RELIEF VALVE(S) FOR THE TENSIONER SYSTEM TO MAINTAIN SYSTEM PRESSURE AT OR BELOW THE MAXIMUM ALLOWABLE WORKING PRESSURE OF THE BOTTLES WHICH IS 2400 PSI.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Construction/Loadline
Issued 25 July 1986 Resolved
REMOVE ALL WATER FROM PORT COLUMN NO.3. RIG SUBSEQUENTLY TO BE BALLASTED TO DRAFT OF APPROXIMATELY 40'. SOUNDINGS (OR VISUAL OBSERVATIONS) ARE TO BE TAKEN OF THIS COLUMN AT LEAST WEEKLLY FOR A PERIOD OF ONE MONTH. PROVIDE INFORMATION OF OBSERVATIONS TO [name withheld] FOR DETERMINATION
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Documentation
Issued 25 July 1986 Resolved
VESSEL'S OPERATING MANUAL IS TO BE UPDATED WITH THE APPROVED AMENDMENTS AND KEPT IN A SINGLE BINDER.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Lifesaving
Issued 25 July 1986 Resolved
PROVIDE THE FOLLOWING ADDITIONAL SUPPLIES FOR THE RIG'S FIRST-AID KIT: (14) TRIANGULAR BANDAGES, (1) TOURNIQUET, (8) 4" BANDAGE COMPRESSES, (4) 2" COMPRESSES.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Construction/Loadline
Issued 25 July 1986 Resolved
CHANGE DRAINAGE SYSTEM ON HELO DECK TO PREVENT LIQUIDS FROM SPREADING TO, OR FALLING ON OTHER PARTS OF THE RIG (46 CFR 108.235(D)(2)).
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Electrical
Issued 25 July 1986 Resolved
PROVIDE LOCKING HASP (HANDLE) FOR SOUND POWERED TELEPHONE BOX, LOCATED IN THE PORT PUMP ROOM.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Lifesaving
Issued 25 July 1986 Resolved
PROVIDE 132 QUARTS OF DRINKING WATER FOR NO.1 AND NO.2 LIFEBOAT.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Fire Fighting
Issued 25 July 1986 Resolved
POST AN APPROVED COPY OF THE FIRE CONTROL PLAN THAT IS LEGIBLE; (ONE PRES- ENTLY ON BULKHEAD IS FADED TO BE UNREADABLE).
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Documentation
Issued 25 July 1986 Resolved
VESSEL'S CONSTRUCTION PORTFOLIO TO BE APPROVED BY U.S. COAST GUARD, MERCHANT MARINE TECHNICAL (MMT) WASHINGTON, DC.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Deck/Cargo
Issued 25 July 1986 Resolved
RELOCATE HOSE CONNECTION ON FUEL OIL PIPE AND PROVIDE FOR POLLUTION CONTAINMENT - PORT AND STARBOARD SIDES.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Deck/Cargo
Issued 25 July 1986 Resolved
FUEL OIL TRANSFER HOSE TO BE STENCILED "OIL SERVICE" AND HYDROED IN ACCORDANCE WITH 33 CFR 156.170.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.