Records from 1982 to 2007. Most recent: inspection, 14 June 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
14 June 2007
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 2962530
14 March 2005
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2310018
26 February 2004
Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2013175
21 January 2003
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1732820
5 April 2002
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1603305
6 March 2002
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1492377
5 March 2002
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1491167
22 January 2001
Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427964
27 October 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1054810
6 July 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445511
22 December 1998
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1441514
21 July 1998
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 795449
30 June 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419963
29 July 1997
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1447759
17 December 1996
Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424320
3 October 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165520
25 June 1996
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460011
15 June 1995
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419445
21 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1142456
8 February 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1163898
30 September 1993
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1160208
11 August 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1268222
4 June 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1270498
6 May 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 954310
13 November 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1249491
17 July 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 940942
1 August 1990
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1233173
28 February 1990
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 932101
9 August 1989
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1041489
18 October 1988
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 887448
3 August 1988
Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1348591
4 May 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1349056
3 February 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1326648
14 October 1987
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1322547
4 November 1986
Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1327007
15 August 1985
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 989447
11 June 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1288067
30 April 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280654
3 February 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280652
11 August 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1275578
13 April 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274151
Construction/Loadline › Hull
Issued 26 February 2004
Resolved
Proceed to drydock to repair leak in steering compt prior to credit for annual inspection. LEGACY COMPONENT DESC: Planking
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2004
Resolution: Owner proceeded to drydock to repair leak in steering compt prior to credit for annual inspection.
Lifesaving › Lifejacket/PFD (Type I)
Issued 26 February 2004
Resolved
Renew lifejackets identified by Marine Inspector. LEGACY COMPONENT DESC: Condition
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2004
Resolution: Owner renewed lifejackets identified by Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety
Issued 26 February 2004
Resolved
Repair hand rails to support 200 lb load IWO bow area. LEGACY COMPONENT DESC: Hand Rails
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2004
Resolution: Owner repaired hand rails to support 200 lb load IWO bow area.
Construction/Loadline › Hull
Issued 26 February 2004
Resolved
Pull 16 fasteners for credit hull exam. LEGACY COMPONENT DESC: Fasteners
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2004
Resolution: Owner pulled 16 fasteners for credit hull exam.
Navigation › Piloting/Steering
Issued 26 February 2004
Resolved
Provide tide tables IAW 46 CFR 184.420. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2004
Resolution: Owner provided tide tables IAW 46 CFR 184.420.
Communications › Radio Communications
Issued 26 February 2004
Resolved
Provide EPIRB hydro release unit IAW 46 CFR 185.728. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2004
Resolution: Owner provided EPIRB hydro release unit IAW 46 CFR 185.728.
Documentation › Certificates/Documents
Issued 26 February 2004
Resolved
Provide drug card for deckhand IAW 46 CFR part 16. LEGACY COMPONENT DESC: Proof of Consortium Enrollment (DAPI)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2004
Resolution: Owner provided drug card for deckhand IAW 46 CFR part 16.
Construction/Loadline › Hull
Issued 26 February 2004
Resolved
Provide repair proposal for transom bottom frame connection portside where decayed. LEGACY COMPONENT DESC: Transverse Frame
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2004
Resolved 16 March 2004
Resolution: Owner provided repair proposal for transom bottom frame connection portside where decayed.
Construction/Loadline › Penetrations
Issued 26 February 2004
Resolved
Replace through hull fitting for live well supply. LEGACY COMPONENT DESC: Bottom Plug Seat
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2004
Resolved 16 March 2004
Resolution: Owner replaced through hull fitting for live well supply.
Construction/Loadline › Structures
Issued 26 February 2004
Resolved
Provide additional vertical stiffeners for main salon decking both sides outboard main engines. LEGACY COMPONENT DESC: Vertical Stiffener
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2004
Resolved 16 March 2004
Resolution: Owner provided additional vertical stiffeners for main salon decking both sides outboard main engines.
Engineering › Steering Gear System
Issued 26 February 2004
Resolved
Repack both rudder bearings LEGACY COMPONENT DESC: Rudder Bearing
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2004
Resolved 16 March 2004
Resolution: Owner repacked both rudder bearings
Engineering › Shafting/Propeller Arrangements
Issued 26 February 2004
Resolved
Replace cutlass bearings both shaft struts. LEGACY COMPONENT DESC: Strut Bearing
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2004
Resolved 16 March 2004
Resolution: Owner replaced cutlass bearings both shaft struts.
Construction/Loadline › Hull
Issued 26 February 2004
Resolved
Rework gunnel caps both sides cockpit where wasted. LEGACY COMPONENT DESC: Gunnel Caps
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2004
Resolved 16 March 2004
Resolution: Owner reworked gunnel caps both sides cockpit where wasted.
Construction/Loadline › Structures
Issued 26 February 2004
Resolved
Make engine room bulkhead vapor tight. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2004
Resolved 16 March 2004
Resolution: Owner made engine room bulkhead vapor tight.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 5 March 2002
Resolved
Have fixed fire fighting system serviced IAW 46CFR 176.810
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2002
Resolved 6 March 2002
Resolution: O/O had fixed system serviced by marine services company.
Engineering › Bilge Water Management System
Issued 5 March 2002
Resolved
Provide portable hand bilge pump IAW 46 CFR 182.570 prior to carrying passengers for hire. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2002
Resolved 5 April 2002
Resolution: Owner provided new portable hand bilge pump.
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 March 2002
Resolved
Renew rertro reflective tape on child lifejackets IAW 46 CFR 185.604 prior to carrying passengers for hire. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2002
Resolved 5 April 2002
Resolution: Owner renewed retro reflective tape on child lifejackets.
Lifesaving › Lifebuoys
Issued 5 March 2002
Resolved
Renew life ring retro reflective tape IAW 46 CFR 185.604 prior to carrying passnegers for hire.
Due 5 April 2002
Resolved 5 April 2002
Resolution: Owner renewed lifering retro reflective tape.
Lifesaving › Buoyant Apparatus
Issued 5 March 2002
Resolved
Renew retro reflective tape on buoyant apparatus IAW 46 CFR 180.200 prior to carrying passengers for hire. LEGACY COMPONENT DESC: Retro reflective marking
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2002
Resolved 5 April 2002
Resolution: Owner renewed retro reflective tape on buoyant apparatus.
Communications › Radio Communications
Issued 5 March 2002
Resolved
Renew hydro static release for Epirb IAW 185.728 prior to carrying passengers for hire. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2002
Resolved 5 April 2002
Resolution: Owner renewed hydro static release for EPIRB.
Communications › Alarms/Indicators
Issued 5 March 2002
Resolved
Repair high level alarm in fwd peak IAW 46 CFR 182.530 LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2002
Resolved 5 April 2002
Resolution: Owner repaired high level alarm in fwd peak.
Fire Fighting › Fire Hoses
Issued 5 March 2002
Resolved
Provide 3 Fire Buckets labled "fire bucket" IAW 46 CFR 181. 300 prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2002
Resolved 5 April 2002
Resolution: Owner provided 3 fire buckets labeled "fire bucket".
Navigation › Piloting/Steering
Issued 5 March 2002
Resolved
Provide navigation publications Coast Pilot, CG Light List, tides and currents table IAW 46 CFR 184.420 LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2002
Resolved 5 April 2002
Resolution: Owner provided nav. pubs Coast pilot, CG Light list, Tides and Currents table.
Navigation
Issued 27 October 2000
Resolved
PROVIDE CURRENT CHARTS AND PUBLICATIONS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Construction/Loadline
Issued 27 October 2000
Resolved
PROVIDE PROPER GASKET ON FWD DECK HATCH AS REQUIRED BY 46 CFR 171.124
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Electrical
Issued 27 October 2000
Resolved
PROVIDE BATTERY BOXES AS REQUIRED BY 46 CFR 176.806
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Accommodation/Occupational Safety
Issued 27 October 2000
Resolved
PROPERLY LOCK MSD OVERBOARD VALVE AS REQUIRED BY 46 CFR 176.818
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Electrical
Issued 30 June 1998
Resolved
Install light cover on cabin light port side. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 July 1998
Resolved 23 July 1998
Electrical
Issued 30 June 1998
Resolved
Provide boot or cover for positive terminals on 12 volt batteries.
Condition: Unknown
Due 4 July 1998
Resolved 23 July 1998
Documentation
Issued 30 June 1998
Resolved
Post each page of COI under glass in cabin.
Condition: Unknown
Due 4 July 1998
Resolved 23 July 1998
Navigation
Issued 30 June 1998
Resolved
Provide current charts and NAV INFO (REED'S ALMANAC).
Condition: Unknown
Due 4 July 1998
Resolved 23 July 1998
Lifesaving
Issued 30 June 1998
Resolved
Restock first aid kit. (Use list of req. items).
Condition: Unknown
Due 4 July 1998
Resolved 23 July 1998
Lifesaving
Issued 30 June 1998
Resolved
Provide crew training log and EPIRB test log._x001C_
Condition: Unknown
Due 4 July 1998
Resolved 23 July 1998
Electrical
Issued 30 June 1998
Resolved
Rewire 12 volt accessory wiring in engine room using proper distribution panels, wire runs, and junction boxes where needed IAW 46 CFR 183 and ABYC rules for electrical installations.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Lifesaving
Issued 30 June 1998
Resolved
Provide orange watertight container for flares labelled "DISTRESS SIGNALS".
Condition: Unknown
Due 4 July 1998
Resolved 23 July 1998
Lifesaving
Issued 29 July 1997
Resolved
RENEW OR REPLACE LIFE RING BUOY AND RETRO-REFLECTIVE TAPE AS REQUIRED IN 46CFR 185.604(B)(I).
Condition: Unknown
Due 29 August 1997
Resolved 7 October 1997
Lifesaving
Issued 29 July 1997
Resolved
MAKE REPAIRS TO THE BAIT TANK CIRCULATION PUMP SUPPLY PIPING AT PUMP DISCHARGE TO STOP LEAKAGE, PREVENT BREAKAGE AND FLOODING POSSIBILITY.
Condition: Unknown
Due 29 August 1997
Resolved 7 October 1997
Construction/Loadline
Issued 17 December 1996
Resolved
REFASTEN 1ST PORT SIDE UNDERDECK BEAM TO FRAME IN THE MACHINERY SPACE.
Condition: Unknown
Due 17 February 1997
Resolved 28 April 1997
Engineering
Issued 17 December 1996
Resolved
PROPERLY ALIGN AND TIGHTEN HOSE CLAMPS FOR BOTH EXHAUST SYSTEMS HOSE TO MUFFLER CONNECTIONS.
Condition: Unknown
Due 17 February 1997
Resolved 28 April 1997
Construction/Loadline
Issued 17 December 1996
Resolved
DETERMINE EXTENT OF REPAIRS NECESSARY AND SUBMIT FOR APPROVAL THE CORRECTIVE REPAIRS TO RESTORE THE STBD UNDERSIDE AREA CABIN BENEATH THE SUPERSTRUCTURE IN WAY OF OVERHEAD PANELING. ALL DECAYED WOOD IS TO BE REPLACED, ANY ROTTEN WOOD TO BE REMOVED AND REPLACED.
Condition: Unknown
Due 17 March 1997
Resolved 28 April 1997
Construction/Loadline
Issued 17 December 1996
Resolved
SISTER/REPLACE 2ND PORT SIDE FRAME TO UNDERDECK BEAM AND REFASTEN SAME.
Condition: Unknown
Due 17 February 1997
Resolved 28 April 1997
Navigation
Issued 17 December 1996
Resolved
RENEW RUDDER RAM BOLTS ON BOTH ENDS OF RAM, TO REDUCE AMOUNT OF PLAY IN STEERING LINKAGE. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 February 1997
Resolved 28 April 1997
Documentation
Issued 25 June 1996
Resolved
PROVIDE CREW TRAING LOG IAW 46 CFR 185.420(a)&(b), 185.520 & 185.524 TO THESATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
PROVIDE COAST GUARD APPROVED, PROPERLY SIZED WEAK LINK FOR VSL'S LIFEFLOAT.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
PROVIDE AND POST LIFE JACKET DONNING PLACARD IAW 46 CFR 515.516(a).
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 15 June 1995
Resolved
PROVID MOISTURE TIGHT CONTAINER WITH VESSEL'S NAME FOR FLARES.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Lifesaving
Issued 15 June 1995
Resolved
RE-STENCIL VESSEL'S NAME ON LIFE FLOAT.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Lifesaving
Issued 15 June 1995
Resolved
PERMANENTLY ATTACH 100' LINE TO WEAK LINK AND LIFE FLOAT.
Condition: Unknown
Due 15 July 1995
Resolved 23 June 1995
Lifesaving
Issued 15 June 1995
Resolved
PERMANENTLY ATTACH WATERLIGHT TO LIFE FLOAT.
Condition: Unknown
Due 15 July 1995
Resolved 23 June 1995
Engineering
Issued 15 June 1995
Resolved
REPAIR SALT WATER LEAK ON PORT ENGINE COOLING SYSTEM.
Condition: Unknown
Due 15 July 1995
Resolved 23 June 1995
Engineering
Issued 15 June 1995
Resolved
REPAIR EXCESSIVE LEAKING ON PORT SHAFT LOG.
Condition: Unknown
Due 15 July 1995
Resolved 23 June 1995
Electrical
Issued 15 June 1995
Resolved
INSTALL METAL WIRE CLAMPS ON OVERHEAD WIRE RUNS IN ENGINE ROOM AT INTERVALSOF 18".
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Construction/Loadline
Issued 15 June 1995
Resolved
NUMERIOUS HULL REPAIRS WERE COMPLETED DURING THIS DRYDOCK SEE MINS CASE NUMBER MI95022313 FOR DETAILS.
Condition: Unknown
Due 15 June 1995
Resolved 28 June 1995
Navigation
Issued 15 June 1995
Resolved
PROVE PROPER OPERTATION OF RUNNING LIGHTS AND ANCHOR LIGHT.
Condition: Unknown
Due 15 July 1995
Resolved 23 June 1995
Engineering
Issued 15 June 1995
Resolved
REPAIR FUEL LEAK ON STBD ENGINE AT CONNECTION TO ENGINE.
Condition: Unknown
Due 15 July 1995
Resolved 23 June 1995
Navigation
Issued 15 June 1995
Resolved
PROVIDE CHART FOR NAVIGATION IN LOCAL OPERATING AREA.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Electrical
Issued 15 June 1995
Resolved
ELECTRICALLY BOND ALL THROUGH HULL FITTINGS.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Navigation
Issued 15 June 1995
Resolved
REPAIR PORT RUNNING LIGHT.
Condition: Unknown
Due 15 July 1995
Resolved 23 June 1995
Lifesaving
Issued 15 June 1995
Resolved
PERMANENTLY ATTACH 60' LINE TO RING BUOY.
Condition: Unknown
Due 15 July 1995
Resolved 23 June 1995
Lifesaving
Issued 15 June 1995
Resolved
PERMANENTLY ATTACH WATERLIGHT TO RING BUOY WITH 6' LINE.
Condition: Unknown
Due 15 July 1995
Resolved 23 June 1995
Accommodation/Occupational Safety
Issued 15 June 1995
Resolved
INSTALL 30X30 MESH SCREEN ON MSD TANK VENT.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Accommodation/Occupational Safety
Issued 15 June 1995
Resolved
PROVIDE A MEANS OF INDICATING 3/4 FULL LEVEL OF MSD HOLDING TANK.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Documentation
Issued 15 June 1995
Resolved
PROVIDE AND POST WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Lifesaving
Issued 30 September 1993
Resolved
PROVIDE PROPER STORAGE FOR LIFEJACKETS AND LABLE SAME IN ACCORDANCE WITH 46CFR 180.25-10.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Documentation
Issued 30 September 1993
Resolved
PROVIDE PROOF OF FCC MARINE RADIO OPERATORS PERMITT.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Engineering
Issued 30 September 1993
Resolved
PROVE OPERATION OF INSTALLED MDE TACHOMETERS.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Documentation
Issued 30 September 1993
Resolved
PROVIDE PROOF OF CHEMICAL DRUG TESTING IN ACCORDANCE WITH 46 CFR PART 16.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Lifesaving
Issued 30 September 1993
Resolved
PROVIDE ONE ADDITIONAL ADULT LIFEJACKET
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Electrical
Issued 17 July 1991
Resolved
REMOVE ALL DEAD END WIRING.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Lifesaving
Issued 17 July 1991
Resolved
RENEW NETTING IN LIFE FLOAT TO PROPER SIZE.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Fire Fighting
Issued 17 July 1991
Resolved
PROVIDE AND INSTALL TWO (2) MARINE APPROVED FIRE EXTINGUISHER BRACKETS.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Navigation
Issued 17 July 1991
Resolved
RELOCATE MAST HEAD LIGHT AND PROVIDE AND INSTALL ANCHOR LIGHT IN ACCORDANCEWITH 72 COLREGS.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Accommodation/Occupational Safety
Issued 17 July 1991
Resolved
REMOVE ALL TINTED GLASS IN PILOT HOUSE.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Navigation
Issued 17 July 1991
Resolved
PROVIDE AND INSTALL SIDE LIGHT IN ACCORDANCE WITH 72 COLREGS.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Unknown
Issued 1 August 1990
Resolved
REPACK RUDDER BARRELS.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Unknown
Issued 1 August 1990
Resolved
STENCIL ESCAPE HATCH AND EMERGENCY EXITS.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Engineering
Issued 1 August 1990
Resolved
REPAIR/REPLACE LEAKING AUX. BILGE PUMP.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Unknown
Issued 1 August 1990
Resolved
STENCIL EMERGENCY FUEL SHUT OFFS.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Unknown
Issued 1 August 1990
Resolved
INSTALL VALVE TO REAR ENGINE ROOM BILGFE PUMP DISCHARGE STBD SIDE.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Unknown
Issued 1 August 1990
Resolved
INSTALL BONDING STRAP ON FUEL OIL FILL LINES.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Unknown
Issued 1 August 1990
Resolved
PROVIDE WATERPROOF CONTAINER FOR FLARES.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Unknown
Issued 1 August 1990
Resolved
REPAIR VESSELS HORN.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Unknown
Issued 1 August 1990
Resolved
DOUBLE HOSE CLAMP ALL OVERBOARD DISCHARGE PIPING AND RAW WATER SUCTION PIPING.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Engineering
Issued 1 August 1990
Resolved
REPAIR LEAKS ON BOTH MDE EXHAUST PIPING.
Condition: Unknown
Due 1 August 1990
Resolved 1 August 1990
Documentation
Issued 9 August 1989
Resolved
PROVIDE VALID RENEWAL DECAL FOR CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Construction/Loadline
Issued 9 August 1989
Resolved
PROVIDE PERMANENT REPAIRS TO BOW IN WAY OF STEM AND PORT & STBD HULL LEAKS.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Unknown
Issued 3 August 1988
Resolved
PROVIDE AN ADDITIONAL ELECTRIC BILGE PUMP FOR FORWARD AREA.
Condition: Unknown
Due 3 August 1988
Resolved 3 August 1988
Unknown
Issued 3 August 1988
Resolved
REPLACE TWO OUTBOARD BECKETS ON LIFEFLOAT.
Condition: Unknown
Due 3 August 1988
Resolved 3 August 1988
Unknown
Issued 3 August 1988
Resolved
PROPERLY BRACKET ALL FIVE FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 August 1988
Resolved 3 August 1988
Unknown
Issued 3 August 1988
Resolved
IAW 46 CFR 182.20-40(B)(3) PROVIDE ACCESS TO REMOTE FOSO VALVES OUTSIDE OF SPACE AND PROPERLY MARK SAME.
Condition: Unknown
Due 3 August 1988
Resolved 3 August 1988
Unknown
Issued 3 August 1988
Resolved
STENCIL LOCATION OF CABIN PFD'S.
Condition: Unknown
Due 3 August 1988
Resolved 3 August 1988
Unknown
Issued 3 August 1988
Resolved
POST ALL CERTIFICATES UNDER GLASS.
Condition: Unknown
Due 3 August 1988
Resolved 3 August 1988
Documentation
Issued 14 October 1987
Resolved
PROVIDE AND PLACE ONBOARD VALID FCC SAFETY RADIOTELEPPHONE CERTIFICATE.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987