GERMAN TRADER is a 1981 tank ship. The Coast Guard has recorded 50 inspections since 1984, most recently in December 2002, along with 124 deficiencies and 2 operational controls.

Records from 1984 to 2002. Most recent: inspection, 12 December 2002.

Built
1981
Last inspected
12 December 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8014203 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-54068

Inspections, by type

…with no type recorded37
Years with a record 16 calendar years (1984–2002)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12758 - Regulatory (Subpart C or D), Gross Ton
7470 - Regulatory (Subpart C or D), Net Ton
22305 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 50

12 December 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1727099
1 May 2002 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1611653
4 April 2002 Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1600932
26 November 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 295695
26 November 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1451793
14 August 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 292619
14 August 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1373580
6 April 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276589
6 April 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 816813
29 March 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 275991
5 January 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 436174
19 August 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 431960
16 May 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 428597
19 February 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 425733
16 February 1999 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 425471
16 February 1999 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 793824
29 July 1998 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 726768
17 July 1998 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 418453
15 March 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 413686
14 March 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 105961
5 December 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 410740
26 November 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 410206
29 October 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 679849
26 October 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396806
13 May 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 391275
3 March 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 388612
3 March 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 886231
1 July 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 381200
23 June 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 379888
14 March 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 700511
13 March 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 862376
9 March 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 453019
10 December 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1145182
8 May 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 917593
7 March 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 912844
6 March 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 342237
16 September 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 332735
16 September 1989 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1000791
6 September 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 505103
20 April 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 503642
21 October 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 494280
12 October 1987 Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1014080
22 May 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 454733
22 May 1987 MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027462
9 December 1986 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024516
15 July 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 519277
29 August 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 514436
27 August 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1295622
22 January 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 478305
12 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282821

Deficiency record · 124

Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 28 November 2001 Resolved
Vessel failed to report into the northern right whale WHALESSOUTH MSR prior to entering the Port of Brunswick, Ga.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 November 2001
Resolved 28 November 2001
Resolution: Enforcement case initiated.
Deck/Cargo
Issued 14 August 2001 Resolved
Port anchor chain locker water tight door lower seal edge wasted. Repair to satisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Lifesaving
Issued 14 August 2001 Resolved
Port side lifeboat cable winch drum wasted. Have Class Society address in drydock.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Unknown
Issued 14 August 2001 Resolved
Request Class Society Audit for ISM.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Documentation
Issued 14 August 2001 Resolved
Non-comformaties Identified in ships ISM audit. Shall be addressed with a written report from master to uscg. Prior to departing Baltimore.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Documentation
Issued 14 August 2001 Resolved
Company to provide written request for proposed voyage plan/request.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Documentation
Issued 14 August 2001 Resolved
Master to provide Germanisher Lloyds (Main Office) final findings report prior to departing Port of Baltimore.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Emergency rescue hatch for pump room missing dogs. Replace to the satisfaction of Class.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Documentation
Issued 14 August 2001 Resolved
The company must establish a set course of action correcting ISM issues from audit in writing and provide a copy to uscg. prior to departing Baltimore.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Lifesaving
Issued 14 August 2001 Resolved
Embarkation ladder for stbd. liferaft/lifeboat to be renewed to the satisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Fire Fighting
Issued 14 August 2001 Resolved
Update fire control plans to include proper number and location of fire hoses.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Engineering
Issued 14 August 2001 Resolved
Renew as original all fuel oil containments as necessary. Including vent standpipe.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Engineering
Issued 14 August 2001 Resolved
Class to adress steam pipe condition and pipe clamps to include steam box on aft center of cargo block cargo tank #8.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Lifesaving
Issued 14 August 2001 Resolved
Vessel to provide a gas free Marine Chemist certificate for Cargo pump roomand #4 wing ballast tank.
Condition: Unknown
Due 18 August 2001
Resolved 17 August 2001
Fire Fighting
Issued 14 August 2001 Resolved
Emergency fire pump priming pump not working. Make repairs to the satisfaction of Class.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Lifesaving
Issued 14 August 2001 Resolved
Replace stokes litter for emergency escape located in cargo pump room.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Accommodation/Occupational Safety
Issued 14 August 2001 Resolved
Missing handrail on fwd port side and wasted handrails on ladders up to catwalk. Repair to the satisfaction of Class.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Have Class Society Surveyor attest to replacement of vertical stiffiner on bow in boatswain stores. Wasted.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Fire Fighting
Issued 14 August 2001 Resolved
Make proper repairs to the cross connect pipe between #1 and #2 fire pump to the satifaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Roller chalks on bow wasted.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Secure spare anchor on main bow port. Mounting bracket wasted.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Navigation
Issued 14 August 2001 Resolved
Rudder post leaking IWO packing. Class to attest to proper repairs.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Accommodation/Occupational Safety
Issued 14 August 2001 Resolved
Salt water cooling pipes for the #1 reefer pump, soft patches and excessivetemporary repairs. Make permanent repairs.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Accommodation/Occupational Safety
Issued 14 August 2001 Resolved
Salt water supply line for toilets located between engine room entrance andscrubber wasted and 2 soft patches. Make permanent repairs.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Engineering
Issued 14 August 2001 Resolved
Main Diesel Engine soot trap holed. Make permanent repairs to the satisfation of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Accommodation/Occupational Safety
Issued 14 August 2001 Resolved
High water alarm on MSD tank missing. Replace.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Accommodation/Occupational Safety
Issued 14 August 2001 Resolved
Have Class attest to repair of MSD tank. Aft inboard top corner has a doubler.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Make permanent repairs to chain pipe port side located on fore castle. Wasted.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Vessel's Class to recommend repairs to wasted shell frame located in the boatswain stores.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Lifesaving
Issued 14 August 2001 Resolved
Class to attest to general condition of hull on starboard lifeboat.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Cargo pump exhaust duct wasted at suction side of fan assembly. Repair to the satisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Engineering
Issued 14 August 2001 Resolved
class report #S08 dated 8/18/01 in respects of fuel tank to remain empty until repaired in drydock to satisfaction of class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Pump room port fwd corner at main deck fractured. Repair to the satisfation of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Port catwalk pipe support IWO #4 center cargo tank wasted. Repair to satisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Support for cargo hose storage aft of stbd. manifold wasted. Repair to thesatisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Transverse deck frame IWO #6 stbd. C/T (1 transverse aft of stbd. manifold,crack at deck, at end of transverse). Repair to the satisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Have Class to attest to condition of port and starboard anchor chains, excessive wastage.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Engineering
Issued 14 August 2001 Resolved
The condensate cooler salt water discharge overboard pipe, remove/repair tothe satisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Electrical
Issued 14 August 2001 Resolved
Make permanent repairs to raw water cooling lines for #1 and #2 ship's generators to the satisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Unknown
Issued 14 August 2001 Resolved
Make permanent repairs to salt water cooling pump piping for auxiliary equipment to the satisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Cargo pipe/conduit/vent piping brackets supports and clamps condition to beaddressed by Class/attending USCG Inspector.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Severe wastage of conduit piping throughout cargo block. Repair to the satisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
IGS deck seal, Class to attest to the proper repair/operation of the following: low water sensor, drain pipe, fill pipe, and site glass.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Cargo pump room exhaust vent pipe at riser cracked/wasted. Repair to the satisfaction of Class.
Condition: Unknown
Due 26 November 2001
Resolved 27 November 2001
Lifesaving
Issued 14 August 2001 Resolved
Resting block missing for starboard lifeboat. Have Class Society to attestto replacement.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Lifesaving
Issued 14 August 2001 Resolved
Have Class Society Surveyor attest to proper operation of releasing hooks on both port and starboard lifeboats.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Electrical
Issued 14 August 2001 Resolved
Boiler steam control missing from control panel. Replace or blank off control panel hole.
Condition: Unknown
Due 15 August 2001
Resolved 16 August 2001
Lifesaving
Issued 14 August 2001 Resolved
Replace food rations in both lifeboats. Vacuum seals are broken. Total of 60 needed.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Lifesaving
Issued 14 August 2001 Resolved
Have Class Society Surveyor attest to the replacement of aft lifting hook IWO pin on port lifeboat, wasted.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Lifesaving
Issued 14 August 2001 Resolved
Have Class Society Surveyor to attest to replacement/repairs on port lifeboat's outer upper aft sheave and lower inboard sheave by catwalk.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Lifesaving
Issued 14 August 2001 Resolved
Have Class Society attest to proper repairs of forward and aft inner sheaves IWO catwalk on starboard lifeboat, wasted.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Navigation
Issued 14 August 2001 Resolved
Have Class attest to proper operation of the follow up indicators in wheelhouse. Inoperable.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Install gaskets on pump man store vent.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Replace dogs on boatswain hatch. Missing.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Electrical
Issued 14 August 2001 Resolved
Lower fwd engine room lighting inoperable. Make permanent repairs.
Condition: Unknown
Due 18 August 2001
Resolved 16 August 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Replace foam room vent cover. Missing.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Fix gasket on dry stores hatch.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Have Class attest to repairs of rope stores, hatch aft. Wasted.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Lifesaving
Issued 14 August 2001 Resolved
Replace bridgewing lifebuoys, not 4kg.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Lifesaving
Issued 14 August 2001 Resolved
Replace lifebuoy light near stbd. lifeboat. Light inoperable.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Navigation
Issued 14 August 2001 Resolved
ARPA missing appoval placard.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Navigation
Issued 14 August 2001 Resolved
Incorrect name on manuevering fact sheet warnig statement.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Construction/Loadline
Issued 14 August 2001 Resolved
Replace 1 dog on fwd rope stores hatch. Missing.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Fire Fighting
Issued 14 August 2001 Resolved
Replace gasket on fwd port side fire hydrant. Missing.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Fire Fighting
Issued 14 August 2001 Resolved
Fire hose station #18, replace damaged nozzle gasket.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Navigation
Issued 14 August 2001 Resolved
Steering gear block diagram missing on bridge.
Condition: Unknown
Due 18 August 2001
Resolved 20 August 2001
Deck/Cargo
Issued 6 April 2000 Resolved
PRIOR TO LOADING CARGOES REQUIRING VAPOR CONTROL, PROVE PROPER OPERATION OFPRESSURE ALARMS IAW 46 CFR 39.20-13.
Condition: Unknown
Due 20 November 2000
Resolved 20 November 2000
Deck/Cargo
Issued 6 April 2000 Resolved
PRIOR TO LOADING CARGOES THAT REQUIRE VAPOR RECOVERY, FIT VAPOR FLANGES WITH .5 X 1.0 INCH STUDS IAW 46 CFR 39.20-1.
Condition: Unknown
Due 20 November 2000
Resolved 20 November 2000
Engineering
Issued 29 March 2000 Resolved
CEMENT PATCH ON AFT COVER OF MAIN DIESEL ENGINE FORWARD OF THE JACKET WATERCOOLER.
Condition: Unknown
Due 20 November 2000
Resolved 20 November 2000
Fire Fighting
Issued 29 March 2000 Resolved
DAMAGED FOAM EXTINGUISHER IN AFTER STEERING. CORRECTIVE ACTION TAKEN.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Lifesaving
Issued 29 March 2000 Resolved
DEAD MAN BRAKE ON THE PORT AND STARBOARD LIFEBOAT DAVITS NEED TO BE CLEANEDAND LUBRICATED.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Lifesaving
Issued 29 March 2000 Resolved
PORT AND STARBOARD LIFEBOATS MISSING MACHINERY GUARD COVERS FOR ENGINES._x001C_ EXPOSED FLYWHEEL, TIMING CHAIN AND PROPELLER SHAFT CAUSING HAZARDOUS CONDITIONS DUE TO ROTATING MACHINERY.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Deck/Cargo
Issued 29 March 2000 Resolved
PORT AND STARBOARD ANCHOR CHAINS NEED TO BE REPLACED AT NEXT DRYDOCK, _x001C_ 01 NOVEMBER 00. MULTIPLE ANCHOR CHAIN STUDS MISSING OR BROKEN.
Condition: Unknown
Due 20 August 2001
Resolved 20 August 2001
Deck/Cargo
Issued 16 February 1999 Resolved
THREE (3) USED HOSES ON MAIN DECK, AND TWELVE (12) USED HOSES IN CATWALK STORAGE BIN {w/GRATTED BOTTOM}, NOT CONNECTED TO MANIFOLDS OR BLANKED OFF /FITTED WITH BUTTERFLY VALVES, WAFER-TYPE RESILIENT SEATED VALVES, OR BLANK FLANGES.
Condition: Unknown
Due 19 February 1999
Resolved 19 February 1999
Navigation
Issued 17 July 1998 Resolved
YYY
Condition: Unknown
Due 19 February 1999
Resolved 19 February 1999
Construction/Loadline
Issued 5 December 1997 Resolved
REPAIR WEATHER TIGHT DOOR PORT SIDE AFT 03 DECK IAW ILLC 66 ANNEX/18.
Condition: Unknown
Due 15 March 1998
Resolved 15 March 1998
Fire Fighting
Issued 5 December 1997 Resolved
VESSEL TO REPLACE FIRE HOSE #23 AS PER SOLAS 60 REG II/65(c)2.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Fire Fighting
Issued 5 December 1997 Resolved
BREATHING APPERATUS DID NOT HAVE ADEQUATE AIR SUPPLY IAW SOLAS 74 AMENDED II/2/17.1.2.2
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Construction/Loadline
Issued 5 December 1997 Resolved
Loadline not painted in contrasting colors to hull IAW ILLC 66 ANNEX I/8.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Lifesaving
Issued 26 November 1997 Resolved
PERFORM DRILLS ie FIRE AND LIFEBOAT SATISFACTORILY TO A COAST GUARD INSPECTOR PRIOR TO 08DEC97.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Lifesaving
Issued 13 May 1996 Resolved
Renew wasted deck plating at #2 foam station, prior to returning to U.S. from overseas port.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Deck/Cargo
Issued 13 May 1996 Resolved
Have class provide proper documentation for VCS IAW 46 CFR 39, prior to operating system.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Accommodation/Occupational Safety
Issued 13 May 1996 Resolved
Repair holed sewage overboard discharge line prior to returning to U.S fromoverseas.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Lifesaving
Issued 13 May 1996 Resolved
Renew wasted deck plating and steam line IWO mid-ship store room, prior to returning to U.S. from overseas.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 13 May 1996 Resolved
Have class surveyor inspect and make recommendation to repair wasted section of fore peak tank top.
Condition: Unknown
Due 14 May 1996
Resolved 21 May 1996
Lifesaving
Issued 13 May 1996 Resolved
Replace missing weak links for liferafts.
Condition: Unknown
Due 14 May 1996
Resolved 21 May 1996
Deck/Cargo
Issued 3 March 1996 Resolved
Replace the missing bonnet bolts on the various cargo P/V vent valves priorto return to a U.S. port. _x001C_ _x001C_ BCH II/2.13
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Fire Fighting
Issued 3 March 1996 Resolved
Remove the hold back hooks on the port / stbd main deck, stairway fire doors prior to return to a U.S. port._x001C_ _x001C_ SOLAS II-2/51.d
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Lifesaving
Issued 3 March 1996 Resolved
The port lifeboat propeller shaft fractured into two pieces. Make permanent repairs and prove proper operation of engine propeller prior to departure. _x001C_ SOLAS 74 III/9.a
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Electrical
Issued 3 March 1996 Resolved
Replace the 4 black electrical cables, leading from the chemical suit locker, with armored cables approved for hazardous locations prior to return to a U.S. port. (ref item 19) _x001C_ BCH III/3.5.2
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Deck/Cargo
Issued 3 March 1996 Resolved
Cargoes requiring use of the Inert Gas System are prohibited until system examined by C.G. Inspectors. System is currently secured. Also note the missing deck valve handles. _x001C_ SOLAS 74 II-2/62
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Deck/Cargo
Issued 3 March 1996 Resolved
Properly repair or replace the heat exchangers in the upper level of the pump room (2). They have welded repairs on the expansion joints on the port ends. Complete prior to return to a U.S. port. _x001C_ BCH II/2.15.1
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Deck/Cargo
Issued 3 March 1996 Resolved
Replace all missing cargo system valve handles. Note all drains and alternate fill line valves on the side of the tank man hole openings. Complete prior to return to a U.S. port. _x001C_ BCH II/2.10
Condition: Unknown
Due 19 April 1996
Resolved 18 April 1996
Deck/Cargo
Issued 3 March 1996 Resolved
Many bolt / nut connections on the hydraulic pump lines and P/V valves are wasted and seized together. Renew as necessary prior to return to a U.S. port. _x001C_ BCH II/2.10
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Navigation
Issued 3 March 1996 Resolved
Make permanent repairs to the bridge rudder angle indicator. It sticks / skips at low angles. Complete prior to return to a U.S. port._x001C_ _x001C_ SOLAS 74 amd V/12.m
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Construction/Loadline
Issued 3 March 1996 Resolved
Repair the double bottom tank vent in the stbd, lower level pump room wherepatched (2 locations) prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/20.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Accommodation/Occupational Safety
Issued 3 March 1996 Resolved
Replace the wasted center deck grate on all 4 P/V vent riser towers prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/25.2
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Construction/Loadline
Issued 3 March 1996 Resolved
Properly close the 4 cable passage holes (minor) from the stbd chemical suit locker to the foam tank space. Also close the vent hole (old pipe penetration) above the locker door. Complete prior to return to a U.S. port. BCH II/2.7.2
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 3 March 1996 Resolved
The outboard grab rail on the port lifeboat is crushed into the side. Makepermanent repairs prior to return to a U.S. port. _x001C_ _x001C_ SOLAS 74 III/11
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Accommodation/Occupational Safety
Issued 3 March 1996 Resolved
Replace the wasted deck grating aft of the #1 foam monitor prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/25
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Construction/Loadline
Issued 3 March 1996 Resolved
Make permanent repairs to the forepeak tank vent where wasted through in the forecastle space (stbd side) prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/20
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Construction/Loadline
Issued 3 March 1996 Resolved
Replace the missing / wasted bilge valve handles to the fwd cofferdam space. These 4 valves are located fwd on the cargo block WX deck. Complete prior to return to a U.S. port. _x001C_ SOLAS 74 II-1/19
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Construction/Loadline
Issued 3 March 1996 Resolved
Replace the two missing dogs on the hatch leading to the forecastle space prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/15
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Deck/Cargo
Issued 3 March 1996 Resolved
Replace the badly wasted steam line coupling flanges over the #2 center cargo tank prior to return to a U.S. port. _x001C_ _x001C_ BCH II/2.15.1
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 3 March 1996 Resolved
Repair the jury rigged wiring on the hydraulic line flow meter sensor in the forecastle space (centerline, aft) prior to return to a U.S. port. _x001C_ SOLAS 74 II-1/27.a.vi
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Accommodation/Occupational Safety
Issued 3 March 1996 Resolved
Secure all loose deck plates in the pump room lower level and replace valvehole covers where missing prior to return to a U.S. port. _x001C_ _x001C_ BCH II/2.8.1
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Deck/Cargo
Issued 3 March 1996 Resolved
Replace the missing slop tank cross connect valve handle in the lower levelpump room prior to return to a U.S. port. _x001C_ _x001C_ BCH II/2.10
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 3 March 1996 Resolved
The stbd lifeboat hull is in deteriorated condition with several holes noted. The engine mounts are also in a deteriorated condition. Make Permanent repairs to these items prior to return to a U.S. port. Vessel sailing with liferafts on stbd side per DNV/LI rqmt. SOLAS 74 III/5
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Accommodation/Occupational Safety
Issued 3 March 1996 Resolved
Replace the wasted railings about the #3 foam monitor prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/25.2
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Navigation
Issued 23 June 1995 Resolved
THE PORT AND STARBOARD HYDRAULIC RAMS WERE SCORED FROM THE CYLINDERS. THE PACKING GLAND SEALS WERE LETTING THE HYDRAULIC FLUID OUT PAST THE RAMS.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Fire Fighting
Issued 23 June 1995 Resolved
THE FIREMAIN LINE WAS HOLED AND WASTED IN THREE SPOTS JUST FORWARD OF THE SUPERSTRUCTURE AND IT WAS ALSO CRACKED MIDSHIPS.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Lifesaving
Issued 23 June 1995 Resolved
BOTH LIFEBOATS HULL RIVETS WERE IN QUESTIONABLE CONDITION. THE RIVET HEADSWERE WORN FLAT.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Deck/Cargo
Issued 10 December 1994 Resolved
PRIOR TO NEXT U.S. PORT OF CALL, REPAIR LEAKING DECK STEAM VALVE IN CARGO PUMPROOM.
Condition: Unknown
Due 10 December 1994
Resolved 10 December 1994
Lifesaving
Issued 10 December 1994 Resolved
PRIOR TO NEXT U.S. PORT OF CALL, CONDUCT LIFERAFT DRILLS, BY MOVING LIFERAFTS FROM ONE SIDE OF THE SHIP TO THE OTHER AND RECORD IN SOLAS TRAINING MANUAL AND BE PREPARED TO DEMONSTRATE TO THE U.S. COAST GUARD.
Condition: Unknown
Due 10 December 1994
Resolved 10 December 1994
Deck/Cargo
Issued 7 March 1991 Resolved
PROVE PROPER OPERATION OF INERT GAS SYSTEM, AND ALL REQUIRED ALARMS AND SHUTDOWNS PRIOR TO ENTRY TO U.S. PORT WITH REQUIRED INERTED CARGO.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Navigation
Issued 16 September 1989 Resolved
US LIGHT LIST, VOL 6, 1989, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1989-ALL.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Navigation
Issued 16 September 1989 Resolved
US CHARTS 18645, 20TH ED, 21FEB87, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS:1987-ALL, 1988-ALL, 1989-ALL.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Navigation
Issued 16 September 1989 Resolved
US CHART 18649, 52ND ED, 18 OCT 86, NOT CURRENTLY CORRECTED. MISSING NOTICETO MARINER CORRECTIONS AS FOLLOWS: 1987-ALL, 1988-ALL, 1989-ALL.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Navigation
Issued 16 September 1989 Resolved
US COAST PILOT, VOL 7, 24 ED, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1988-ALL, 1989-ALL.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Navigation
Issued 16 September 1989 Resolved
US CHART 18650, 41 ED, 25FEB89, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1989-ALL.
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Construction/Loadline
Issued 16 September 1989 Resolved
REPLACE PUMP ROOM WATERTIGHT DOOR GASKET.
Condition: Unknown
Due 16 September 1989
Resolved 16 September 1989
Fire Fighting
Issued 16 September 1989 Resolved
PROVIDE SUITABLE MEANS OF SECURING DOORS ON ALL WEATHERDECK FIRE STATIONS ON THE MAIN DECK.
Condition: Unknown
Due 16 September 1989
Resolved 16 September 1989
Deck/Cargo
Issued 16 September 1989 Resolved
PRIOR TO LOADING ANY CARGO REQUIRING INERTING, DEMONSTRATE PROPER OPERATIONOF INERT GAS SYSTEM TO A USCG MARINE INSPECTOR.
Condition: Unknown
Due 16 September 1989
Resolved 16 September 1989
Deck/Cargo
Issued 22 May 1987 Resolved
PROVIDE UNDERWATER CONNECTION FOR NLS CARGOS IN ACCORDANCE WITH 46CFR153.470.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.