← All vessels
GERMAN TRADER
GERMAN TRADER is a 1981 tank ship. The Coast Guard has recorded 50 inspections since 1984, most recently in December 2002, along with 124 deficiencies and 2 operational controls.
Records from 1984 to 2002. Most recent: inspection, 12 December 2002.
- Built
- 1981
- Last inspected
- 12 December 2002
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 124 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8014203 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELMO2
54068
Flag
PANAMA
—
Maury page id
psix-54068
Inspections, by type
…with no type recorded37
Years with a record
16 calendar years (1984–2002)
The 50 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it12758 - Regulatory (Subpart C or D), Gross Ton
7470 - Regulatory (Subpart C or D), Net Ton
22305 - Dead Weight, Ton
7470 - Regulatory (Subpart C or D), Net Ton
22305 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 50
12 December 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1727099
1 May 2002
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1611653
4 April 2002
Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1600932
26 November 2001
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 295695
26 November 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1451793
14 August 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 292619
14 August 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1373580
6 April 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276589
6 April 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 816813
29 March 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 275991
5 January 2000
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 436174
19 August 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 431960
16 May 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 428597
19 February 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 425733
16 February 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 425471
16 February 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 793824
29 July 1998
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 726768
17 July 1998
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 418453
15 March 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 413686
14 March 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 105961
5 December 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 410740
26 November 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 410206
29 October 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 679849
26 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396806
13 May 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 391275
3 March 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 388612
3 March 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 886231
1 July 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 381200
23 June 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 379888
14 March 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 700511
13 March 1995
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 862376
9 March 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 453019
10 December 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1145182
8 May 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 917593
7 March 1991
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 912844
6 March 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 342237
16 September 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 332735
16 September 1989
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1000791
6 September 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 505103
20 April 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 503642
21 October 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 494280
12 October 1987
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1014080
22 May 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 454733
22 May 1987
MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027462
9 December 1986
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024516
15 July 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 519277
29 August 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 514436
27 August 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1295622
22 January 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 478305
12 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282821
Deficiency record · 124
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 28 November 2001
Resolved
Vessel failed to report into the northern right whale WHALESSOUTH MSR prior to entering the Port of Brunswick, Ga.
Deck/Cargo
Issued 14 August 2001
Resolved
Port anchor chain locker water tight door lower seal edge wasted. Repair to satisfaction of Class.
Lifesaving
Issued 14 August 2001
Resolved
Port side lifeboat cable winch drum wasted. Have Class Society address in drydock.
Unknown
Issued 14 August 2001
Resolved
Request Class Society Audit for ISM.
Documentation
Issued 14 August 2001
Resolved
Non-comformaties Identified in ships ISM audit. Shall be addressed with a written report from master to uscg. Prior to departing Baltimore.
Documentation
Issued 14 August 2001
Resolved
Company to provide written request for proposed voyage plan/request.
Documentation
Issued 14 August 2001
Resolved
Master to provide Germanisher Lloyds (Main Office) final findings report prior to departing Port of Baltimore.
Construction/Loadline
Issued 14 August 2001
Resolved
Emergency rescue hatch for pump room missing dogs. Replace to the satisfaction of Class.
Documentation
Issued 14 August 2001
Resolved
The company must establish a set course of action correcting ISM issues from audit in writing and provide a copy to uscg. prior to departing Baltimore.
Lifesaving
Issued 14 August 2001
Resolved
Embarkation ladder for stbd. liferaft/lifeboat to be renewed to the satisfaction of Class.
Fire Fighting
Issued 14 August 2001
Resolved
Update fire control plans to include proper number and location of fire hoses.
Engineering
Issued 14 August 2001
Resolved
Renew as original all fuel oil containments as necessary. Including vent standpipe.
Engineering
Issued 14 August 2001
Resolved
Class to adress steam pipe condition and pipe clamps to include steam box on aft center of cargo block cargo tank #8.
Lifesaving
Issued 14 August 2001
Resolved
Vessel to provide a gas free Marine Chemist certificate for Cargo pump roomand #4 wing ballast tank.
Fire Fighting
Issued 14 August 2001
Resolved
Emergency fire pump priming pump not working. Make repairs to the satisfaction of Class.
Lifesaving
Issued 14 August 2001
Resolved
Replace stokes litter for emergency escape located in cargo pump room.
Accommodation/Occupational Safety
Issued 14 August 2001
Resolved
Missing handrail on fwd port side and wasted handrails on ladders up to catwalk. Repair to the satisfaction of Class.
Construction/Loadline
Issued 14 August 2001
Resolved
Have Class Society Surveyor attest to replacement of vertical stiffiner on bow in boatswain stores. Wasted.
Fire Fighting
Issued 14 August 2001
Resolved
Make proper repairs to the cross connect pipe between #1 and #2 fire pump to the satifaction of Class.
Deck/Cargo
Issued 14 August 2001
Resolved
Roller chalks on bow wasted.
Deck/Cargo
Issued 14 August 2001
Resolved
Secure spare anchor on main bow port. Mounting bracket wasted.
Navigation
Issued 14 August 2001
Resolved
Rudder post leaking IWO packing. Class to attest to proper repairs.
Accommodation/Occupational Safety
Issued 14 August 2001
Resolved
Salt water cooling pipes for the #1 reefer pump, soft patches and excessivetemporary repairs. Make permanent repairs.
Accommodation/Occupational Safety
Issued 14 August 2001
Resolved
Salt water supply line for toilets located between engine room entrance andscrubber wasted and 2 soft patches. Make permanent repairs.
Engineering
Issued 14 August 2001
Resolved
Main Diesel Engine soot trap holed. Make permanent repairs to the satisfation of Class.
Accommodation/Occupational Safety
Issued 14 August 2001
Resolved
High water alarm on MSD tank missing. Replace.
Accommodation/Occupational Safety
Issued 14 August 2001
Resolved
Have Class attest to repair of MSD tank. Aft inboard top corner has a doubler.
Deck/Cargo
Issued 14 August 2001
Resolved
Make permanent repairs to chain pipe port side located on fore castle. Wasted.
Construction/Loadline
Issued 14 August 2001
Resolved
Vessel's Class to recommend repairs to wasted shell frame located in the boatswain stores.
Lifesaving
Issued 14 August 2001
Resolved
Class to attest to general condition of hull on starboard lifeboat.
Deck/Cargo
Issued 14 August 2001
Resolved
Cargo pump exhaust duct wasted at suction side of fan assembly. Repair to the satisfaction of Class.
Engineering
Issued 14 August 2001
Resolved
class report #S08 dated 8/18/01 in respects of fuel tank to remain empty until repaired in drydock to satisfaction of class.
Deck/Cargo
Issued 14 August 2001
Resolved
Pump room port fwd corner at main deck fractured. Repair to the satisfation of Class.
Construction/Loadline
Issued 14 August 2001
Resolved
Port catwalk pipe support IWO #4 center cargo tank wasted. Repair to satisfaction of Class.
Deck/Cargo
Issued 14 August 2001
Resolved
Support for cargo hose storage aft of stbd. manifold wasted. Repair to thesatisfaction of Class.
Construction/Loadline
Issued 14 August 2001
Resolved
Transverse deck frame IWO #6 stbd. C/T (1 transverse aft of stbd. manifold,crack at deck, at end of transverse). Repair to the satisfaction of Class.
Deck/Cargo
Issued 14 August 2001
Resolved
Have Class to attest to condition of port and starboard anchor chains, excessive wastage.
Engineering
Issued 14 August 2001
Resolved
The condensate cooler salt water discharge overboard pipe, remove/repair tothe satisfaction of Class.
Electrical
Issued 14 August 2001
Resolved
Make permanent repairs to raw water cooling lines for #1 and #2 ship's generators to the satisfaction of Class.
Unknown
Issued 14 August 2001
Resolved
Make permanent repairs to salt water cooling pump piping for auxiliary equipment to the satisfaction of Class.
Deck/Cargo
Issued 14 August 2001
Resolved
Cargo pipe/conduit/vent piping brackets supports and clamps condition to beaddressed by Class/attending USCG Inspector.
Deck/Cargo
Issued 14 August 2001
Resolved
Severe wastage of conduit piping throughout cargo block. Repair to the satisfaction of Class.
Deck/Cargo
Issued 14 August 2001
Resolved
IGS deck seal, Class to attest to the proper repair/operation of the following: low water sensor, drain pipe, fill pipe, and site glass.
Deck/Cargo
Issued 14 August 2001
Resolved
Cargo pump room exhaust vent pipe at riser cracked/wasted. Repair to the satisfaction of Class.
Lifesaving
Issued 14 August 2001
Resolved
Resting block missing for starboard lifeboat. Have Class Society to attestto replacement.
Lifesaving
Issued 14 August 2001
Resolved
Have Class Society Surveyor attest to proper operation of releasing hooks on both port and starboard lifeboats.
Electrical
Issued 14 August 2001
Resolved
Boiler steam control missing from control panel. Replace or blank off control panel hole.
Lifesaving
Issued 14 August 2001
Resolved
Replace food rations in both lifeboats. Vacuum seals are broken. Total of 60 needed.
Lifesaving
Issued 14 August 2001
Resolved
Have Class Society Surveyor attest to the replacement of aft lifting hook IWO pin on port lifeboat, wasted.
Lifesaving
Issued 14 August 2001
Resolved
Have Class Society Surveyor to attest to replacement/repairs on port lifeboat's outer upper aft sheave and lower inboard sheave by catwalk.
Lifesaving
Issued 14 August 2001
Resolved
Have Class Society attest to proper repairs of forward and aft inner sheaves IWO catwalk on starboard lifeboat, wasted.
Navigation
Issued 14 August 2001
Resolved
Have Class attest to proper operation of the follow up indicators in wheelhouse. Inoperable.
Construction/Loadline
Issued 14 August 2001
Resolved
Install gaskets on pump man store vent.
Construction/Loadline
Issued 14 August 2001
Resolved
Replace dogs on boatswain hatch. Missing.
Electrical
Issued 14 August 2001
Resolved
Lower fwd engine room lighting inoperable. Make permanent repairs.
Construction/Loadline
Issued 14 August 2001
Resolved
Replace foam room vent cover. Missing.
Construction/Loadline
Issued 14 August 2001
Resolved
Fix gasket on dry stores hatch.
Construction/Loadline
Issued 14 August 2001
Resolved
Have Class attest to repairs of rope stores, hatch aft. Wasted.
Lifesaving
Issued 14 August 2001
Resolved
Replace bridgewing lifebuoys, not 4kg.
Lifesaving
Issued 14 August 2001
Resolved
Replace lifebuoy light near stbd. lifeboat. Light inoperable.
Navigation
Issued 14 August 2001
Resolved
ARPA missing appoval placard.
Navigation
Issued 14 August 2001
Resolved
Incorrect name on manuevering fact sheet warnig statement.
Construction/Loadline
Issued 14 August 2001
Resolved
Replace 1 dog on fwd rope stores hatch. Missing.
Fire Fighting
Issued 14 August 2001
Resolved
Replace gasket on fwd port side fire hydrant. Missing.
Fire Fighting
Issued 14 August 2001
Resolved
Fire hose station #18, replace damaged nozzle gasket.
Navigation
Issued 14 August 2001
Resolved
Steering gear block diagram missing on bridge.
Deck/Cargo
Issued 6 April 2000
Resolved
PRIOR TO LOADING CARGOES REQUIRING VAPOR CONTROL, PROVE PROPER OPERATION OFPRESSURE ALARMS IAW 46 CFR 39.20-13.
Deck/Cargo
Issued 6 April 2000
Resolved
PRIOR TO LOADING CARGOES THAT REQUIRE VAPOR RECOVERY, FIT VAPOR FLANGES WITH .5 X 1.0 INCH STUDS IAW 46 CFR 39.20-1.
Engineering
Issued 29 March 2000
Resolved
CEMENT PATCH ON AFT COVER OF MAIN DIESEL ENGINE FORWARD OF THE JACKET WATERCOOLER.
Fire Fighting
Issued 29 March 2000
Resolved
DAMAGED FOAM EXTINGUISHER IN AFTER STEERING. CORRECTIVE ACTION TAKEN.
Lifesaving
Issued 29 March 2000
Resolved
DEAD MAN BRAKE ON THE PORT AND STARBOARD LIFEBOAT DAVITS NEED TO BE CLEANEDAND LUBRICATED.
Lifesaving
Issued 29 March 2000
Resolved
PORT AND STARBOARD LIFEBOATS MISSING MACHINERY GUARD COVERS FOR ENGINES._x001C_ EXPOSED FLYWHEEL, TIMING CHAIN AND PROPELLER SHAFT CAUSING HAZARDOUS CONDITIONS DUE TO ROTATING MACHINERY.
Deck/Cargo
Issued 29 March 2000
Resolved
PORT AND STARBOARD ANCHOR CHAINS NEED TO BE REPLACED AT NEXT DRYDOCK, _x001C_ 01 NOVEMBER 00. MULTIPLE ANCHOR CHAIN STUDS MISSING OR BROKEN.
Deck/Cargo
Issued 16 February 1999
Resolved
THREE (3) USED HOSES ON MAIN DECK, AND TWELVE (12) USED HOSES IN CATWALK STORAGE BIN {w/GRATTED BOTTOM}, NOT CONNECTED TO MANIFOLDS OR BLANKED OFF /FITTED WITH BUTTERFLY VALVES, WAFER-TYPE RESILIENT SEATED VALVES, OR BLANK FLANGES.
Navigation
Issued 17 July 1998
Resolved
YYY
Construction/Loadline
Issued 5 December 1997
Resolved
REPAIR WEATHER TIGHT DOOR PORT SIDE AFT 03 DECK IAW ILLC 66 ANNEX/18.
Fire Fighting
Issued 5 December 1997
Resolved
VESSEL TO REPLACE FIRE HOSE #23 AS PER SOLAS 60 REG II/65(c)2.
Fire Fighting
Issued 5 December 1997
Resolved
BREATHING APPERATUS DID NOT HAVE ADEQUATE AIR SUPPLY IAW SOLAS 74 AMENDED II/2/17.1.2.2
Construction/Loadline
Issued 5 December 1997
Resolved
Loadline not painted in contrasting colors to hull IAW ILLC 66 ANNEX I/8.
Lifesaving
Issued 26 November 1997
Resolved
PERFORM DRILLS ie FIRE AND LIFEBOAT SATISFACTORILY TO A COAST GUARD INSPECTOR PRIOR TO 08DEC97.
Lifesaving
Issued 13 May 1996
Resolved
Renew wasted deck plating at #2 foam station, prior to returning to U.S. from overseas port.
Deck/Cargo
Issued 13 May 1996
Resolved
Have class provide proper documentation for VCS IAW 46 CFR 39, prior to operating system.
Accommodation/Occupational Safety
Issued 13 May 1996
Resolved
Repair holed sewage overboard discharge line prior to returning to U.S fromoverseas.
Lifesaving
Issued 13 May 1996
Resolved
Renew wasted deck plating and steam line IWO mid-ship store room, prior to returning to U.S. from overseas.
Construction/Loadline
Issued 13 May 1996
Resolved
Have class surveyor inspect and make recommendation to repair wasted section of fore peak tank top.
Lifesaving
Issued 13 May 1996
Resolved
Replace missing weak links for liferafts.
Deck/Cargo
Issued 3 March 1996
Resolved
Replace the missing bonnet bolts on the various cargo P/V vent valves priorto return to a U.S. port. _x001C_ _x001C_ BCH II/2.13
Fire Fighting
Issued 3 March 1996
Resolved
Remove the hold back hooks on the port / stbd main deck, stairway fire doors prior to return to a U.S. port._x001C_ _x001C_ SOLAS II-2/51.d
Lifesaving
Issued 3 March 1996
Resolved
The port lifeboat propeller shaft fractured into two pieces. Make permanent repairs and prove proper operation of engine propeller prior to departure. _x001C_ SOLAS 74 III/9.a
Electrical
Issued 3 March 1996
Resolved
Replace the 4 black electrical cables, leading from the chemical suit locker, with armored cables approved for hazardous locations prior to return to a U.S. port. (ref item 19) _x001C_ BCH III/3.5.2
Deck/Cargo
Issued 3 March 1996
Resolved
Cargoes requiring use of the Inert Gas System are prohibited until system examined by C.G. Inspectors. System is currently secured. Also note the missing deck valve handles. _x001C_ SOLAS 74 II-2/62
Deck/Cargo
Issued 3 March 1996
Resolved
Properly repair or replace the heat exchangers in the upper level of the pump room (2). They have welded repairs on the expansion joints on the port ends. Complete prior to return to a U.S. port. _x001C_ BCH II/2.15.1
Deck/Cargo
Issued 3 March 1996
Resolved
Replace all missing cargo system valve handles. Note all drains and alternate fill line valves on the side of the tank man hole openings. Complete prior to return to a U.S. port. _x001C_ BCH II/2.10
Deck/Cargo
Issued 3 March 1996
Resolved
Many bolt / nut connections on the hydraulic pump lines and P/V valves are wasted and seized together. Renew as necessary prior to return to a U.S. port. _x001C_ BCH II/2.10
Navigation
Issued 3 March 1996
Resolved
Make permanent repairs to the bridge rudder angle indicator. It sticks / skips at low angles. Complete prior to return to a U.S. port._x001C_ _x001C_ SOLAS 74 amd V/12.m
Construction/Loadline
Issued 3 March 1996
Resolved
Repair the double bottom tank vent in the stbd, lower level pump room wherepatched (2 locations) prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/20.
Accommodation/Occupational Safety
Issued 3 March 1996
Resolved
Replace the wasted center deck grate on all 4 P/V vent riser towers prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/25.2
Construction/Loadline
Issued 3 March 1996
Resolved
Properly close the 4 cable passage holes (minor) from the stbd chemical suit locker to the foam tank space. Also close the vent hole (old pipe penetration) above the locker door. Complete prior to return to a U.S. port. BCH II/2.7.2
Lifesaving
Issued 3 March 1996
Resolved
The outboard grab rail on the port lifeboat is crushed into the side. Makepermanent repairs prior to return to a U.S. port. _x001C_ _x001C_ SOLAS 74 III/11
Accommodation/Occupational Safety
Issued 3 March 1996
Resolved
Replace the wasted deck grating aft of the #1 foam monitor prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/25
Construction/Loadline
Issued 3 March 1996
Resolved
Make permanent repairs to the forepeak tank vent where wasted through in the forecastle space (stbd side) prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/20
Construction/Loadline
Issued 3 March 1996
Resolved
Replace the missing / wasted bilge valve handles to the fwd cofferdam space. These 4 valves are located fwd on the cargo block WX deck. Complete prior to return to a U.S. port. _x001C_ SOLAS 74 II-1/19
Construction/Loadline
Issued 3 March 1996
Resolved
Replace the two missing dogs on the hatch leading to the forecastle space prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/15
Deck/Cargo
Issued 3 March 1996
Resolved
Replace the badly wasted steam line coupling flanges over the #2 center cargo tank prior to return to a U.S. port. _x001C_ _x001C_ BCH II/2.15.1
Electrical
Issued 3 March 1996
Resolved
Repair the jury rigged wiring on the hydraulic line flow meter sensor in the forecastle space (centerline, aft) prior to return to a U.S. port. _x001C_ SOLAS 74 II-1/27.a.vi
Accommodation/Occupational Safety
Issued 3 March 1996
Resolved
Secure all loose deck plates in the pump room lower level and replace valvehole covers where missing prior to return to a U.S. port. _x001C_ _x001C_ BCH II/2.8.1
Deck/Cargo
Issued 3 March 1996
Resolved
Replace the missing slop tank cross connect valve handle in the lower levelpump room prior to return to a U.S. port. _x001C_ _x001C_ BCH II/2.10
Lifesaving
Issued 3 March 1996
Resolved
The stbd lifeboat hull is in deteriorated condition with several holes noted. The engine mounts are also in a deteriorated condition. Make Permanent repairs to these items prior to return to a U.S. port. Vessel sailing with liferafts on stbd side per DNV/LI rqmt. SOLAS 74 III/5
Accommodation/Occupational Safety
Issued 3 March 1996
Resolved
Replace the wasted railings about the #3 foam monitor prior to return to a U.S. port. _x001C_ _x001C_ ICLL 66 II/25.2
Navigation
Issued 23 June 1995
Resolved
THE PORT AND STARBOARD HYDRAULIC RAMS WERE SCORED FROM THE CYLINDERS. THE PACKING GLAND SEALS WERE LETTING THE HYDRAULIC FLUID OUT PAST THE RAMS.
Fire Fighting
Issued 23 June 1995
Resolved
THE FIREMAIN LINE WAS HOLED AND WASTED IN THREE SPOTS JUST FORWARD OF THE SUPERSTRUCTURE AND IT WAS ALSO CRACKED MIDSHIPS.
Lifesaving
Issued 23 June 1995
Resolved
BOTH LIFEBOATS HULL RIVETS WERE IN QUESTIONABLE CONDITION. THE RIVET HEADSWERE WORN FLAT.
Deck/Cargo
Issued 10 December 1994
Resolved
PRIOR TO NEXT U.S. PORT OF CALL, REPAIR LEAKING DECK STEAM VALVE IN CARGO PUMPROOM.
Lifesaving
Issued 10 December 1994
Resolved
PRIOR TO NEXT U.S. PORT OF CALL, CONDUCT LIFERAFT DRILLS, BY MOVING LIFERAFTS FROM ONE SIDE OF THE SHIP TO THE OTHER AND RECORD IN SOLAS TRAINING MANUAL AND BE PREPARED TO DEMONSTRATE TO THE U.S. COAST GUARD.
Deck/Cargo
Issued 7 March 1991
Resolved
PROVE PROPER OPERATION OF INERT GAS SYSTEM, AND ALL REQUIRED ALARMS AND SHUTDOWNS PRIOR TO ENTRY TO U.S. PORT WITH REQUIRED INERTED CARGO.
Navigation
Issued 16 September 1989
Resolved
US LIGHT LIST, VOL 6, 1989, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1989-ALL.
Navigation
Issued 16 September 1989
Resolved
US CHARTS 18645, 20TH ED, 21FEB87, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS:1987-ALL, 1988-ALL, 1989-ALL.
Navigation
Issued 16 September 1989
Resolved
US CHART 18649, 52ND ED, 18 OCT 86, NOT CURRENTLY CORRECTED. MISSING NOTICETO MARINER CORRECTIONS AS FOLLOWS: 1987-ALL, 1988-ALL, 1989-ALL.
Navigation
Issued 16 September 1989
Resolved
US COAST PILOT, VOL 7, 24 ED, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1988-ALL, 1989-ALL.
Navigation
Issued 16 September 1989
Resolved
US CHART 18650, 41 ED, 25FEB89, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1989-ALL.
Construction/Loadline
Issued 16 September 1989
Resolved
REPLACE PUMP ROOM WATERTIGHT DOOR GASKET.
Fire Fighting
Issued 16 September 1989
Resolved
PROVIDE SUITABLE MEANS OF SECURING DOORS ON ALL WEATHERDECK FIRE STATIONS ON THE MAIN DECK.
Deck/Cargo
Issued 16 September 1989
Resolved
PRIOR TO LOADING ANY CARGO REQUIRING INERTING, DEMONSTRATE PROPER OPERATIONOF INERT GAS SYSTEM TO A USCG MARINE INSPECTOR.
Deck/Cargo
Issued 22 May 1987
Resolved
PROVIDE UNDERWATER CONNECTION FOR NLS CARGOS IN ACCORDANCE WITH 46CFR153.470.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.