Records from 1982 to 2014. Most recent: inspection, 6 October 2014.
Inspection history · 58
6 October 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5018899
20 January 2009
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3396975
9 January 2009
Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3391332
14 March 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3164434
16 January 2008
Drydock Extension
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3131672
10 January 2008
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3128196
3 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3124277
14 November 2007
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3098322
27 July 2007
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3008904
11 April 2007
Deficiency Check · Plan Review (Other than "T") · Administrative Inspection · Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2910257
26 March 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2898208
8 February 2007
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2869722
29 January 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2863341
19 June 2006
Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2775322
6 June 2006
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2578258
3 April 2006
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2643899
29 March 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2616653
28 June 2005
Examination of Repairs · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2406718
10 January 2005
Plan Review (Other than "T")
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2271767
9 December 2004
In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2257133
6 December 2004
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2254105
4 November 2004
Periodic Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2229871
16 October 2003
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1914142
19 December 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1721025
14 December 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718905
29 August 2002
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1667287
21 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607241
1 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1599746
21 September 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426666
23 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073387
29 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070075
19 April 2001
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062357
11 October 2000
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1361813
30 August 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1448169
8 November 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 806483
12 October 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1463523
19 October 1998
Deficiency Check · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1441420
5 February 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1108805
16 October 1997
Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1431848
13 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774200
22 May 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 203495
22 May 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 768716
3 March 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 157621
23 June 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1204367
28 October 1987
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1021704
7 April 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1329002
29 September 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1006045
18 July 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 986843
23 December 1985
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1302851
25 November 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1301198
7 August 1985
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291270
28 October 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 976669
28 October 1984
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 992332
15 August 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 974815
4 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279921
25 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279920
11 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278158
24 August 1982
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 967301
Construction/Loadline › Hull › Bottom Plating
Issued 14 November 2007
Resolved
Complete SEILOD Phase II.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 16 January 2009
Resolution: Received ABS report for UWILD portion of SEILOD Phase II
//s// [name withheld]
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2007
Resolved
Prove ABS approval on behalf of the Coast Guard under the provisions of NVIC 10-82 Ch. 2 for drawing 06-174-E-03 rev Z (4th level lighting plan and details).
Due 20 May 2007
Resolved 27 July 2007
Resolution: Plans approved.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2007
Resolved
Prove separate main and emergency branch circuits for fourth deck lighting.
Due 20 May 2007
Resolved 27 July 2007
Resolution: Proved by ABS.
Construction/Loadline › Structures › Machinery Space Opening
Issued 8 February 2007
Resolved
Replace watertight door to SCR room.
Condition: Unknown
Due 8 March 2007
Resolved 18 April 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 February 2007
Resolved
Prove obstruction lights operate in sync.
Condition: Unknown
Due 8 March 2007
Resolved 13 February 2007
Lifesaving › Liferaft Equipment › Instructions (immediate action)
Issued 8 February 2007
Resolved
install operating instructions at both liferaft stations.
Condition: Unknown
Due 8 March 2007
Resolved 12 February 2007
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 8 February 2007
Resolved
Prove proper operation of waterspray system on # 1 lifeboat.
Condition: Unknown
Due 15 February 2007
Resolved 12 February 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 February 2007
Resolved
Prove lifebuoys have new retro tape and proper stenciling.
Condition: Unknown
Due 8 March 2007
Resolved 12 February 2007
Fire Fighting › Firemans Outfit › Lantern (Electric Safety Lamp)
Issued 8 February 2007
Resolved
Provide flashlight for each firemans outfit.
Condition: Unknown
Due 8 March 2007
Resolved 12 February 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 3 April 2006
Resolved
2 breakers failed in SCR Bays 3 and 5, causing a fire and explosion. Replace breakers and provide proof of certified electrician testing results.
Condition: Placed in Improper Service
Due 3 May 2006
Resolved 18 April 2006
Resolution: Testing results provided.
Electrical › Electric Supply System (service) › Cable
Issued 10 November 2005
Resolved
Provide secure wire penetrations affected by temporary wiring due to shore power prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2005
Resolved 18 November 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 November 2005
Resolved
Provide appropriate junction box in overhead of hospital space.
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 18 November 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 November 2005
Resolved
Install elecrical box covers on panels in storage closet on the 03 deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2005
Resolved 11 November 2005
Resolution: Panel covers replaced on the lighting distribution panels in utility closte.
Communications › Audible Communications › Horn/Whistle
Issued 10 November 2005
Resolved
Demonstrate operation of purge alarms to satisfaction of marine inspector and prior to drilling operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 14 November 2005
Resolution: Inspected on site by Tim of ABS.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 November 2005
Resolved
Provide amperage on index card in power panels.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2005
Resolved 11 November 2005
Electrical › Electric Generation Source (service) › Conductor
Issued 10 November 2005
Resolved
Renew wire run support trays on port side drill floor.
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 18 April 2007
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 10 November 2005
Resolved
Provide/install emergency lighting in maintenance shop.
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 21 November 2005
Resolution: Installed lighting in Maintenance shop
Fire Fighting › Ventilation Systems › Operating Controls
Issued 10 November 2005
Resolved
Demonstrate proper operations of fire damper by #2 lifeboat.
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 18 November 2005
Lifesaving › Launching Appliances › Release Mechanism
Issued 10 November 2005
Resolved
Demonstrate proper operations of #2 lifeboat limit switch.
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 21 November 2005
Resolution: Proved satisfactory operation of #2 lifeboat limit switch.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 November 2005
Resolved
Renew glass shield for external lighting located on stbd side aft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 21 November 2005
Resolution: Installed shield for external lighting located on stbd side aft.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 10 November 2005
Resolved
Renew sliding rod aft limit switch on #1 lifeboat.
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 18 November 2005
Communications › Internal Communications System › Sound-powered Telephone
Issued 10 November 2005
Resolved
Renew door to communications station (phone station) by #2 lifeboat.
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 18 November 2005
Electrical › Electrical Distribution System (service) › Conductor
Issued 10 November 2005
Resolved
Plug empty watertight electrical penetrations by new storage addition on forward legs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 21 November 2005
Resolution: Plugged empty watertight electrical penetrations.
Electrical › Electric Supply System (service) › Cable
Issued 10 November 2005
Resolved
Remove temporary wiring cables etc in starboard side drill tower.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2005
Resolved 18 November 2005
Resolution: Removed cables prior to departing.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 December 2004
Resolved
Renew or replace time delays in the CO2 system to delay for the time delay as indicated on the bottle "60 sec".
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 16 December 2004
Resolution: Replace time delays and were tested to activate in 60 seconds, as indicated on the bottle.
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 4 November 2004
Resolved
Prove Coast Guard approval for operations manual revision 2.
Due 4 December 2004
Resolved 4 February 2005
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 4 November 2004
Resolved
Prove proper operation of breathing air system on #2 life boat.
Due 3 December 2004
Resolved 6 November 2004
Resolution: Mechanic installed proper popoff .
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 November 2004
Resolved
Prove proper operation of obstruction lights & emergecy batteries feeding obstruction lights.
Due 3 December 2004
Resolved 12 November 2004
Resolution: Electrician fixed.
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 4 November 2004
Resolved
Repair containment at B.J. unit in mud pump room and repair pinhole in bulkhead in mud pump room.
Due 3 December 2004
Resolved 4 November 2004
Resolution: Welder repaired problem areas.
Engineering › Compressed Air System (control) › Compressor
Issued 4 November 2004
Resolved
Repair #1 air compressor, compressor is leaking oil, and prove proper operation.
Due 3 December 2004
Resolved 11 November 2004
Resolution: Mechanic repaired back pressure closing valve.
Fire Fighting › Combustible Materials
Issued 16 October 2003
Resolved
Make repairs to Paint Locker bulkhead where wasted (approximately 7 inched localized wasted area). LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Due 23 October 2003
Resolved 20 October 2003
Engineering › Diesel Engine (auxiliary)
Issued 16 October 2003
Resolved
Repair all oil leaks on emergency generator and remove all excess oil. Remove oil saturated insulation and replace with new.
Due 23 October 2003
Resolved 20 October 2003
Engineering › Diesel Engine (auxiliary)
Issued 16 October 2003
Resolved
Replace cooling fin in emergency generator housing. Ensure that broken pieces are removed.
Condition: Unknown
Due 23 October 2003
Resolved 20 October 2003
Engineering › Diesel Engine (auxiliary)
Issued 16 October 2003
Resolved
Provide 24 hour manned watch on #1 and #2 generator until shutdowns/alarms have been repaired.
Due 23 October 2003
Resolved 17 October 2003
Engineering › Diesel Engine (auxiliary)
Issued 16 October 2003
Resolved
Prove proper operation of all alarms and shutdowns on #1 and #2 generators prior to rig movement or drilling operations.
Due 23 October 2003
Resolved 20 October 2003
Unknown
Issued 21 September 2001
Resolved
Repair/replace wasted mud pit room door. Door to be self closing and gas tight
Condition: Unknown
Due 23 September 2001
Resolved 1 October 2001
Construction/Loadline
Issued 19 April 2001
Resolved
PROVIDE REPAIR PROPOSAL FOR DAMAGE TO BLISTER TANK ON THE PORT AFT COLUMN, ALONG WITH WELDING PROCEDURES AND WELDER'S QUALIFICATIONS TO THE [name withheld].
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 12 October 1999
Resolved
REPAIR/REPLACE SAFETY SKIRTING ON HELO-DECK.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Lifesaving
Issued 12 October 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Lifesaving
Issued 12 October 1999
Resolved
LABEL ALL E-LIGHTS ABOARD RIG AS NEEDED.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Lifesaving
Issued 12 October 1999
Resolved
REPAIR/REPLACE ALL EXIT LIGHTS THROUGHOUT ACCOMMODATIONS & ENSURE OPERATION.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 12 October 1999
Resolved
REPAIR/REPLACE VENTILATION SHUTDOWNS AT ALL STATIONS & PROVE PROPER OPERATION OF EACH IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Lifesaving
Issued 12 October 1999
Resolved
REPAIR/REPLACE LIFEBOAT EMBARKATION LIGHTS & ENSURE PROPER OPERATION.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 12 October 1999
Resolved
REPLACE/RECHARGE SCBA BOTTLE ON FIREMAN'S OUTFIT ADJACENT TO ENGINE ROOM.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 12 October 1999
Resolved
REPAIR/REPLACE BAIL ON FIRE STATION #16 NOZZLE & PROVE PROPER OPERATION.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Engineering
Issued 12 October 1999
Resolved
REPAIR/REPLACE ENGINE FUEL SHUTDOWN & PROVE PROPER OPERATION.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Lifesaving
Issued 12 October 1999
Resolved
REPAIR/REPLACE GENERAL ALARM & BEACON ON DRILL FLOOR & PROVE PROPER OPERATION.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 12 October 1999
Resolved
LABEL & PROVIDE INSTRUCTIONS TO OPERATE HALON RELEASE TO ENGINE ROOM AT BOTTLE BANK.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Electrical
Issued 12 October 1999
Resolved
REPAIR/REPLACE ALL EMERGENCY LIGHTS & TRANSITIONAL LIGHTS THROUGHOUT RIG ASNEEDED.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Construction/Loadline
Issued 12 October 1999
Resolved
REPAIR & ADJUST SELF CLOSING DOORS IN MUDPIT ROOM & PROVE PROPER OPERATION.WIRES THAT HOLD COUNTERWEIGHTS ARE CHAFED SIGNIFICANTLY AND NEED REPLACED ALSO.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Electrical
Issued 19 October 1998
Resolved
PROVIDE NON CONDUCTING BLANKS FOR THE FOLLOWING PANELS: EL, 440 VAC, L2.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Fire Fighting
Issued 19 October 1998
Resolved
ADJUST PACKING AT FIRE STATION #2 VALVE STEM SO AS TO MITIGATE LEAKS.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 19 October 1998
Resolved
PROVE PROPER OPERATIONS OF ALL THE REMOTE VENTILATION SHUT DOWN STATIONS.
Condition: Unknown
Due 20 November 1998
Resolved 19 October 1998
Electrical
Issued 19 October 1998
Resolved
ENSURE TOTCO WIRING TO DRAW WORKS IS INTRINSICALLY SAFE.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Lifesaving
Issued 19 October 1998
Resolved
INSTALL A SAFETY CAGE FOR THE LADDER ABOVE THE ELEVATOR SHAFTS ON THE AFT COLUMS.
Condition: Unknown
Due 20 November 1998
Resolved 10 November 1998
Engineering
Issued 19 October 1998
Resolved
PROVIDE FLAME SCREENS FOR THE OIL TANK STORAGE VENT, PORT SIDE.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Electrical
Issued 19 October 1998
Resolved
PROVIDE E LIGHT FOR THE SCR WEATHER ACCESS DOOR.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Lifesaving
Issued 19 October 1998
Resolved
PROVIDE 100 PSI RELIEF VALVES FOR ALL HOT WATER HEATERS.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Lifesaving
Issued 19 October 1998
Resolved
REPLACE THE LIFE RING UNDER THE DRILL FLOOR.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Electrical
Issued 16 October 1997
Resolved
LABEL BOTH EMERGENCY SHUTDOWN STATIONS FOR THE ENGINEROOM.
Condition: Unknown
Due 16 November 1997
Resolved 19 November 1997
Engineering
Issued 16 October 1997
Resolved
CLEAN LENS ON PRESSURE GAUGE FOR FUEL OIL PUMP IN ENGINEROOM.
Condition: Unknown
Due 16 November 1997
Resolved 19 November 1997
Engineering
Issued 16 October 1997
Resolved
CLEAN OR REPLACE ALL FLAME SCREENS ON DAY TANKS FOR ALL GENERATORS.
Condition: Unknown
Due 16 November 1997
Resolved 19 November 1997
Engineering
Issued 16 October 1997
Resolved
RECONNECT & FUNCTION TEST REMOTE FUEL OIL SHUT-OFF VALVES FOR BOTH MAIN GENERATORS.
Condition: Unknown
Due 16 November 1997
Resolved 19 November 1997
Documentation
Issued 16 October 1997
Resolved
PROVIDE MSO PORT ARTHUR WITH THE ORIGINAL UNDATED STABILITY LETTER FROM ABSFOR THE DEAD WEIGHT SURVEY PERFORMED ON 18 OCT 97.
Condition: Unknown
Due 16 November 1997
Resolved 19 November 1997
Accommodation/Occupational Safety
Issued 16 October 1997
Resolved
REPAIR ALL BROKEN HANDRAILS ON WALKWAY OUTSIDE OF SCR ROOM.
Condition: Unknown
Due 16 November 1997
Resolved 19 November 1997
Electrical
Issued 16 October 1997
Resolved
INSTALL ELECTRICAL STUFFING BOX IN BULKHEAD BETWEEN SCR ROOM AND EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 16 November 1997
Resolved 19 November 1997
Unknown
Issued 7 April 1987
Resolved
MAKE UNIT AVAILABLE FOR DRYDOCK EXAM OR SPECIAL UNDERWATER EXAM IN LIEU OF DRYDOCKING PRIOR TO RETURNING THE RIG TO SERVICE AND NO LATER THAN THE NEXTBIENNIAL INSPECTION. A PROPOSAL MEETING THE REQUIREMENTS OF 46 CFR 107.265MUST BE SUBMITTED 30 DAYS IN ADVANCE IF SPECIAL UNDERWATER EXAM IS PLANNED.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Electrical
Issued 18 July 1986
Resolved
REPAIR OR REPLACE ALL INOPERATIVE GENERAL ALARM BELLS AND RETEST TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Electrical
Issued 18 July 1986
Resolved
PROVIDE SERVICEABLE EMERGENCY LANTERN BATTERIES AND RETEST ALL EMERGENCY LIGHTING IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Fire Fighting
Issued 18 July 1986
Resolved
REINSTALL THE HALON CYLINDER FOR THE MUD PIT RM FIXED FIREFIGHTING SYSTEM WHICH WAS REMOVED FOR SERVICING.
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Lifesaving
Issued 18 July 1986
Resolved
PROVIDE THE RIG WITH 60 SERVICEABLE LIFE JACKETS AND UNTIL PROVIDED LIMIT THE TOTAL PERSONS ALLOWED TO THREE (3) PERSONS.
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Fire Fighting
Issued 18 July 1986
Resolved
REPAIR OR REPLACE THE INOPERATIVE PRESSURE GAUGES ON BOTH FIRE PUMPS AND REPACK THE STBD FIRE PUMP TO STOP EXCESSIVE WATER LEAKS TO THE SATISFACTIONOF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Lifesaving
Issued 7 August 1985
Resolved
REMOVE ALL THE MARINE GROWTH FROM THE EMBARKATION LADDERS.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Navigation
Issued 7 August 1985
Resolved
CLEAN OR REPLACE THE FORWARD STBD OBSTRUCTION LIGHT LENSE COVER.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Lifesaving
Issued 7 August 1985
Resolved
PROVIDE THE #1 & #2 LIFEBOATS WITH 12 SERVICABLE RED PARACHUTE FLARES, 2 ORANGE SMOKE SIGNALS AND INSTALLED INTERIOR LIGHTS. RESECURE THE STBD LIFELINE ON LIFEBOAT #2.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Fire Fighting
Issued 7 August 1985
Resolved
SERVICE THE TWO O2/COMBUSTIBLE GAS INDICATORS.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Electrical
Issued 7 August 1985
Resolved
COMPLETE REPAIRS TO THE BILGE ALARM PANEL AND TEST THE TWO BILGE ALARMS.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Fire Fighting
Issued 7 August 1985
Resolved
MODIFY THE FIRE AND SAFETY CONTROL PLAN TO SHOW THE CAISSON EMBARKATION LADDERS AND TO SHOW THE CORRECT NUMBER OF 1 1/2" & 2 1/2" FIRE HOSE STATIONS.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Fire Fighting
Issued 15 August 1984
Resolved
PROCURE ONE (1) PAIR OF APPROVED GLOVES FOR EACH FIREMANS OUTFIT.
Condition: Unknown
Due 15 August 1984
Resolved 15 August 1984
Lifesaving
Issued 15 August 1984
Resolved
REPAIR OR REPLACE COMPASS ON #1 LIFEBOAT.
Condition: Unknown
Due 15 August 1984
Resolved 15 August 1984