Records from 1982 to 2019. Most recent: inspection, 3 April 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
3 April 2019
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6655146
5 March 2014
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4811395
18 July 2012
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4382075
29 August 2011
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4130217
6 January 2011
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3922838
14 December 2009
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3650071
23 November 2008
Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3367910
26 November 2007
Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3160200
12 August 2005
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2459740
17 May 2004
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2070689
8 November 2002
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1701807
12 September 2001
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1449505
10 May 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 768848
5 May 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 209179
12 November 1999
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 809232
14 September 1999
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1429222
23 June 1999
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1415222
11 September 1998
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1471839
8 September 1998
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 798358
27 January 1998
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1117180
7 November 1997
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 788059
12 September 1997
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1378125
2 February 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1145574
1 April 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1222931
5 February 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919094
14 November 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211292
6 November 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243196
19 July 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1222697
27 March 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234550
25 September 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898396
11 September 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1038156
18 May 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 888823
30 November 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898261
5 August 1988
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1343028
31 July 1987
Hull Examination · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1337567
9 October 1986
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1314806
10 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1306733
1 August 1985
COI Inspection · Credit Drydock · Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291183
10 August 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 975137
11 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966964
Electrical › Electric Generation Source (service) › Panelboard
Issued 29 August 2011
Resolved
Repair/replace the AMP Meters on the Port and Starboard generators.
Action required: 705 - Other - as specified
Due 7 November 2011
Resolved 18 July 2012
Resolution: To the satisfaction of attending marine inspector.
Deck/Cargo › Ballast › Piping
Issued 29 August 2011
Resolved
Make permanent repairs to the ballast fill line in the machinery space.
Action required: 705 - Other - as specified
Due 7 November 2011
Resolved 18 July 2012
Resolution: To the satisfaction of attending marine inspector.
Engineering › Fuel Oil Service System › Piping
Issued 23 November 2008
Resolved
Fuel leak in engine room possibly from fractured fuel piping.
Action required: 705 - Other - as specified
Resolved 12 December 2008
Resolution: Fuel piping was cut out and replaced with new piping.
Lifesaving › Lifefloat › Painter
Issued 23 November 2008
Resolved
Incorrect painter arrangement of life floats.
Action required: 705 - Other - as specified
Resolved 12 December 2008
Lifesaving › Lifefloat › Paddle
Issued 23 November 2008
Resolved
Life floats need proper oars (2 for each float) properly secured.
Action required: 705 - Other - as specified
Resolved 12 December 2008
Lifesaving › Launching Appliances › Release Mechanism
Issued 23 November 2008
Resolved
Replace weak links with proper tags on life floats.
Action required: 705 - Other - as specified
Resolved 12 December 2008
Deck/Cargo › Ballast › Tank
Issued 26 November 2007
Resolved
Fracture on ballast tank.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 November 2007
Resolution: Croped and renewed.
Engineering › Bilge Water Management System › Pump
Issued 26 November 2007
Resolved
Improper Bilge suction. Not in accordance with plans or CFR
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 January 2008
Resolution: Bilge suction made as original.
Deck/Cargo › Ballast › Tank
Issued 26 November 2007
Resolved
Gaskets on hatch and coaming not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 January 2008
Resolution: Replaced and installed stisfactorily.
Construction/Loadline › Hull › Weld
Issued 26 November 2007
Resolved
Deck Insert not welded completely.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 November 2007
Resolution: Weld completed.
Construction/Loadline
Issued 14 September 1999
Resolved
Repair cracked frames in way of port side shell outboard of port Main Diesel Engine.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Construction/Loadline
Issued 14 September 1999
Resolved
Repair cracked frames in way of starboard side engineroom overhead located above starboard Main Diesel Engine.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Deck/Cargo
Issued 14 September 1999
Resolved
Maintain or renew anchor equipment and anchor cable.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Engineering
Issued 14 September 1999
Resolved
Repair and demonstrate proper operation of outboard reachrod for fuel cut out valve on starboard fuel tank.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Construction/Loadline
Issued 14 September 1999
Resolved
Provide dogging wrench in vicinity of each weathertight door._x001C_
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Construction/Loadline
Issued 12 September 1997
Resolved
SECURE HYDRAULIC PIPE IN RUDDER ROOM OVERHEAD SO AS TO NOT CHAFE OR DAMAGE.
Condition: Unknown
Due 31 October 1997
Resolved 10 November 1997
Lifesaving
Issued 12 September 1997
Resolved
INSTALL & TEST ENGINEROOM BILGE ALARMS.
Condition: Unknown
Due 31 October 1997
Resolved 10 November 1997
Lifesaving
Issued 12 September 1997
Resolved
SWING COMPASS AND PROVIDE UPDATED DEVIATION CHART ON BRIDGE.
Condition: Unknown
Due 31 October 1997
Resolved 10 November 1997
Lifesaving
Issued 12 September 1997
Resolved
INSTALL MEANS TO PROVIDE DOUBLE PROTECTION FOR LUBE OIL DISCHARGE VALVE IN WAY OF FORWARD ENGINEROOM STBD SIDE.
Condition: Unknown
Due 31 October 1997
Resolved 10 November 1997
Lifesaving
Issued 12 September 1997
Resolved
MOUNT FRESH WATER PUMP AND HEAD PRESSURE TANK IN FWD ENGINEROOM PORT OF LADDER.
Condition: Unknown
Due 31 October 1997
Resolved 10 November 1997
Fire Fighting
Issued 12 September 1997
Resolved
INSTALL LADDER RUNGS IN WAY OF AFT MAIN DECK ENGINEROOM VENT COVER SO AS TOPROVIDE ACCESS TO CLOSE. (WING NUTS FOR MANUAL SECURING)
Condition: Unknown
Due 31 October 1997
Resolved 10 November 1997
Fire Fighting
Issued 12 September 1997
Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILL IN THE PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 12 September 1997
Resolved 12 September 1997
Electrical
Issued 12 September 1997
Resolved
INSPECT WIRING UNDER WHEELHOUSE FOR PROPER INSTALLATIONS.
Condition: Unknown
Due 31 October 1997
Resolved 10 November 1997
Fire Fighting
Issued 12 September 1997
Resolved
HANG FUEL OIL REMOTE SHUT-DOWN WRENCH AND FWD PEAK WRENCH IN WAY OF CONTROLSTATIONS IAW THE FIRE CONTROL PLAN.
Condition: Unknown
Due 31 October 1997
Resolved 10 November 1997
Fire Fighting
Issued 12 September 1997
Resolved
INSTALL AN APPROVED FIRE CONTROL PLAN WITH EMERGENCY LIGHTING LISTED.
Condition: Unknown
Due 31 October 1997
Resolved 10 November 1997
Construction/Loadline
Issued 12 September 1997
Resolved
REMOVE BILGE PUMP AND PROPERLY SECURE (REMOVE) WIRING IN RUDDER ROOM.
Condition: Unknown
Due 31 October 1997
Resolved 10 November 1997
Lifesaving
Issued 12 September 1997
Resolved
REPAIR RINGER FOR THE SOUND POWERED PHONE FROM THE ENGINEROOM TO BRIDGE. BELL RINGS FROM BRIDGE TO E/R BUT E/R CAN NOT RING BRIDGE.
Condition: Unknown
Due 12 September 1997
Resolved 12 September 1997
Construction/Loadline
Issued 12 September 1997
Resolved
WELD STRUCTURAL MEMBERS AS PER USCG GALMS INSTRUCTIONS IN WAY OF PORT SIDE-SHELL INSERT (APPROX 20 FT X 6 FT) IN ENGINEROOM. STRUCTURAL MEMBERS ARE TO BE WELDED AS ORIGINAL.
Condition: Unknown
Due 12 September 1997
Resolved 12 September 1997
Electrical
Issued 6 November 1990
Resolved
MAKE REPAIRS TO # 2 STEERING PUMP LOSS OF POWER ALARM.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Fire Fighting
Issued 6 November 1990
Resolved
PROVIDE MINIMUM FLOW RATE OF 500 GPM FOR INSTALLED FIRE MONITOR . VESSEL_x001C_ IS NOT TO BE OPERATED AS A STAND BY VESSEL UNDER FIRE MONITOR TESTED BY COAST GUARD INSPECTOR.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Accommodation/Occupational Safety
Issued 6 November 1990
Resolved
PROVIDE SUITABLE LADDER FOR ACCESS TO 02 DECK TO OPERATE FIRE MONITOR AND GAIN ACCESS TO LIFE FLOATS.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Lifesaving
Issued 6 November 1990
Resolved
PROVIDE ONE ADDITIONAL SERVICE LINE FOR LINE THROWING GUN FOR A TOTAL OF FOUR LINES.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Navigation
Issued 6 November 1990
Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Construction/Loadline
Issued 6 November 1990
Resolved
MAKE PERMANANT REPAIRS IN WAY OF TEMPORARY REPAIR TO BILGE MANIFOLD.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Documentation
Issued 11 September 1989
Resolved
PLACE ON BOARD VESSEL, AN APPROVED STABILITY LETTER.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 31 July 1987
Resolved
REPLACE GUARD ON FRONT OF PORT GEN
Condition: Unknown
Due 31 July 1987
Resolved 31 July 1987
Engineering
Issued 31 July 1987
Resolved
RESTENCIL EMERGENCY FUEL SHUTOFFS LOCATED ON MAIN DECK PORT AND STBD
Condition: Unknown
Due 31 July 1987
Resolved 31 July 1987
Lifesaving
Issued 9 October 1986
Resolved
REPAIR/REPLACE LIGHT ON RING BUOY ON MAIN DECK.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Navigation
Issued 9 October 1986
Resolved
REPAIR/RELACE ATTACHMENTS ON JOCKEY BAR FOR STEERING GEAR AT VESSELS NEXT DRYDOCKING, BUT IN ANY EVENT, PRIOR TO 30AUG87.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Navigation
Issued 9 October 1986
Resolved
VESSEL NOT TO BE OPERATED MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL SINGLE SIDE BAND RADIOTELEPHONE IS REINSTALLED AND IN PROPER OPER- ATING CONDITION. IN ANY CASE NLT 31OCT86.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Lifesaving
Issued 1 August 1985
Resolved
PROVIDE 2 PADDLES FOR THE LIFEFLOAT.
Condition: Unknown
Due 1 August 1985
Resolved 1 August 1985
Navigation
Issued 1 August 1985
Resolved
MAKE REPAIR TO THE FOLLOW-UP STEERING MODE.
Condition: Unknown
Due 1 August 1985
Resolved 1 August 1985
Navigation
Issued 10 August 1984
Resolved
REPAIR THE LORAN C RECEIVER.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Documentation
Issued 10 August 1984
Resolved
PLACE ON BOARD A CURRENT EDITION OF THE COAST PILOT.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE THEA, DN626830.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984