MAURY USCG vessel records Sign in
← All vessels

ARAL

ARAL is a 1982 tank ship. The Coast Guard has recorded 25 inspections since 1985, most recently in June 2008, along with 27 deficiencies — 2 with no resolution recorded — and 6 operational controls.

Records from 1985 to 2008. Most recent: inspection, 10 June 2008.

Built
1982
Last inspected
10 June 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8125454 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
CANADA
—
Maury page id
psix-54079

Inspections, by type

…with no type recorded13
…past their stated due date2
Years with a record 9 calendar years (1985–2008)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5285 - Convention (Subpart B), Gross Ton
2687 - Convention (Subpart B), Net Ton
8915 - Dead Weight, Ton
11808 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

10 June 2008 Deficiency Check
Physical examination · Commandant (CG-CVC) · Activity 3232541
16 September 2005 ISPS III Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2494101
8 September 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2487559
1 September 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2480774
29 July 2005 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2444292
8 June 2004 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2092648
2 June 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2087160
7 April 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2043697
20 May 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1798698
20 May 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1804379
26 April 2003 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1780781
11 November 2002 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1703857
2 November 2002 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1699977
25 October 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1696341
24 October 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1695498
7 August 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1659242
6 August 2002 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1657778
6 January 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 39799
20 May 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 510343
20 May 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1194000
30 December 1987 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1007921
29 December 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 320423
27 November 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 469820
27 November 1987 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1027593
19 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984275

Deficiency record · 27

Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 June 2008 No resolution recorded
Vessel owner operator must submit a certification statement that the plan meets the applicable requirements of (33 CFR 155) subpart D.
Action required: 705 - Other - as specified
Due 24 June 2008 — due date passed with no resolution recorded
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 June 2008 No resolution recorded
33 CFR 155.1070 (c)(5) - Revisions or amendments to an approved response plan must be submitted whenever there is - a change in the identification of oil spill removal organization.
Action required: 705 - Other - as specified
Due 24 June 2008 — due date passed with no resolution recorded
Engineering › Generator (propulsion-electric) › Fixture Circuitry
Issued 29 July 2005 Resolved
Moving parts on #1 and #2 diesel generators were not covered.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 30 August 2005
Resolution: RECEIVED SAT CLASS REPORT VIA FAX
Construction/Loadline › Structures › Ventilators
Issued 29 July 2005 Resolved
Cargo pump room unable to be inspected due to high level of VOC's and inadequate ventilation.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 30 August 2005
Resolution: RCVD SAT CLASS REPORT VIA FAX
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 29 July 2005 Resolved
VSL unable to calibrate explosive meters. Missing components to properly calibrate with span gas.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 30 August 2005
Resolution: RCVD SAT CLASS REPORT VIA FAX
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 29 July 2005 Resolved
ODME has been not operating properly for past 3 months. No loading annex 1 cargos.
Action required: 705 - Other - as specified
Resolved 8 September 2005
Resolution: Class Society requirement placed on vessel to correct by 26NOV2005. Until repaired IOPP notes no carriage of annex 1 cargoes.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 8 June 2004 Resolved
The vessel is missing the emergency lightering equipment as required. Provide the appropriate equipment and properly stow and label. LEGACY COMPONENT DESC: Reducers
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2004
Resolved 10 June 2004
Resolution: Received class report from ABS stating that the equipment was placed on board.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 8 June 2004 Resolved
The vessel could not provide documentary proof that the cargo lines, cargo hoses or bunkering lines have been hydrostatically tested to 1.5 times the MAWP within the last year. The vessel must hydrostatically test all cargo lines and hoses and bunkering lines to 1.5 MAWP. LEGACY COMPONENT DESC: Piping and Hoses
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 10 June 2004
Resolution: Received class report from ABS stating that all cargo lines, cargo hoses and bunkering lines were hydrostatically tested to 1.5 times the MAWP in their presence.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 8 June 2004 Resolved
The cargo pump room has excess water and some product (molasses) in bilges and is very dirty. Remove all water, wipe down bulkheads and machinery and remove excess tools and equipment. LEGACY COMPONENT DESC: Pumproom
Action required: 705 - Other - as specified
Due 15 June 2004
Resolved 30 August 2005
Resolution: RCVD SAT CLASS REPORT VIA FAX
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 8 June 2004 Resolved
The vessel could not demonstrate the loss of power alarm for the cargo tank overfill alarm as required by 46 CFR 39.20-7. The vessel is prohibited from loading any oil cargo as defined in 33 CFR 151.05.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2004
Resolved 10 June 2004
Resolution: Received class report from ABS stating that a loss of power alarm was installed and tested satisfactory.
Documentation › Certificates/Documents
Issued 26 April 2003 Resolved
Certificate of Malta Registry not onboard vessel. Agent took original and did not leave a copy with the vessel. LEGACY COMPONENT DESC: Certificate of Registry
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2003
Resolution: Agent faxed vessel Vertificate of Registry to Act NY.
Navigation › Collision/Grounding Avoidance
Issued 6 August 2002 Resolved
Radar display cutting off range indicator at top of the screen. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2002
Resolved 11 November 2002
Resolution: Faxed received stating Radar repairs made and tested to condition of issuing authority.
Deck/Cargo › Cargo Stowage
Issued 6 August 2002 Resolved
#1 center overfill, #2 port overfill, #4 center overfill and high level alarm, and #5 center overfill alarm not operating properly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2002
Resolved 11 November 2002
Resolution: Faxed recieved stating overfills repaired and tested to the satifaction of issuing authority.
Deck/Cargo
Issued 20 May 1989 Resolved
PROVIDE SPAN GAS FOR FIXED GAS DETECTION SYSTEM AND CALIBRATE NLT 30JUN89.
Condition: Unknown
Due 30 June 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 20 May 1989 Resolved
PUMP ROOM MUST BE MADE GAS FREE & PROVIDE CERTIFIED MARINE CHEMIST CERTIFICATE & MAKE AVAILABLE FOR INSPECTION BY COGNIZANT USCG MARINE INSPECTION OFFICE AT EARLIEST CONVENIENCE BUT NLT 20SEP89.
Condition: Unknown
Due 20 September 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 November 1987 Resolved
PRIOR TO NEXT ENTRY INTO U.S. PORT PROVIDE DOCUMENTATION THAT CARGO PIPING SYSTEM HAS BEEN TESTED TO 1.5 MAWP PER 33 CFR 156.170.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987
Unknown
Issued 27 November 1987 Resolved
PRIOR TO DEPARTURE FROM PORT OF HOUSTON, TEXAS, BUT NOT LATER THAN 15DEC87 PROVIDE ONBOARD THE FOLLOWING NAVIGATIONAL PUBLICATIONS: (1) COAST PILOT VOL.5, 1986 ED.; (2) COAST GUARD LIGHT LIST VOL. IV., 1987 ED.; (3) ALL RELATED NAVIGATIONAL CHARTS INCLUDING ASSOCIATED NOTICE TO MARINERS.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987
Unknown
Issued 27 November 1987 Resolved
SUBMIT IMO CHEMICAL CODE CERTIFICATE OF FITNESS TO USCG HQ FOR REVIEW AND OBTAIN SUBCHAPTER "O" ENDORSEMENT. THE ABOVE SHALL BE COMPLETED PRIOR TO CARRIAGE OF THE ABOVE RELATED CARGOES BUT NOT LATER THAN 31DEC87.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987
Unknown
Issued 27 November 1987 Resolved
PRIOR TO DEPARTURE FROM PORT OF HOUSTON, TEXAS, CONTACT CLASSIFICATION SOCIETY AND OBTAIN SUPPLEMENT TO INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE (IOPP) AS ABOVE BUT NOT LATER THAN 15DEC87.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987
Unknown
Issued 19 April 1985 Resolved
INSTALL THREADED CAPS ON CARGO AND FUEL OIL CONTAINMENT DRAINS.
Condition: Unknown
Due 19 April 1985
Resolved 19 April 1985
Unknown
Issued 19 April 1985 Resolved
POST FIRE CONTROL PLAN ON MAIN DECK AND STENCIL LOCATION.
Condition: Unknown
Due 19 April 1985
Resolved 19 April 1985
Unknown
Issued 19 April 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE FOREIGN VESSEL KOMAYA 3.
Condition: Unknown
Due 19 April 1985
Resolved 19 April 1985
Unknown
Issued 19 April 1985 Resolved
RENEW DRAEGER TUBES FOR THE FOLLOWING CARGOES; BENZENE, CHLOROBENZENE, CASHEW NUT SHELL OIL, CYCLOHEXANONE AND 1,2 NITROPROPANE.
Condition: Unknown
Due 19 April 1985
Resolved 19 April 1985
Unknown
Issued 19 April 1985 Resolved
PROVIDE ONE ADDITIONAL DRAEGER ASPIRATOR.
Condition: Unknown
Due 19 April 1985
Resolved 19 April 1985
Unknown
Issued 19 April 1985 Resolved
STOW CARGO SAMPLES IN A VENTILATED SPACE ON THE CARGO DECK.
Condition: Unknown
Due 19 April 1985
Resolved 19 April 1985
Unknown
Issued 19 April 1985 Resolved
PROVIDE ONE ADDITIONAL STRETCHER.
Condition: Unknown
Due 19 April 1985
Resolved 19 April 1985
Unknown
Issued 19 April 1985 Resolved
INSTALL BLANK FLANGES ON ALL CARGO TRANSFER HOSES.
Condition: Unknown
Due 19 April 1985
Resolved 19 April 1985