Records from 1981 to 2010. Most recent: inspection, 12 March 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 65
12 March 2010
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3692352
28 March 2003
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1777592
18 December 2002
Hull Examination · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1720239
14 December 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718927
28 May 2002
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1621782
11 February 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1485360
26 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073165
4 January 2001
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1418828
18 February 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046127
5 January 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815149
5 January 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415295
23 September 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1340654
11 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114748
21 July 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 27240
10 May 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1109615
31 March 1999
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 783601
7 January 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402767
22 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808511
30 November 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805280
25 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798831
6 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773989
6 February 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400716
9 January 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392838
17 November 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1335221
16 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1110761
17 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1095635
9 January 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400476
24 July 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1090650
21 February 1996
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1394471
27 September 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 871151
8 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186025
19 May 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929662
28 March 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1140020
16 February 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1154020
9 January 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438253
25 February 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353531
11 March 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1148007
13 January 1993
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 831606
30 March 1992
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1261154
16 December 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 958763
6 February 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239883
1 February 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241593
13 December 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 906067
12 December 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230981
6 December 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1237629
28 June 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 905864
8 May 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1238489
28 April 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239365
22 February 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1220290
14 January 1990
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922768
1 June 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1344895
24 April 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1275391
18 January 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 891340
20 December 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1038307
12 December 1988
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1341204
26 July 1988
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1196792
17 April 1987
Hull Examination · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1000411
4 February 1987
Drydock Extension · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315370
12 September 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988918
5 February 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1290163
4 February 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 979103
16 January 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 977516
24 August 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966064
25 August 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1274790
27 August 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274546
Fire Fighting › Fire Main
Issued 11 February 2002
Resolved
CROP AND RENEW WASTED SECTION OF FIRE MAIN PIPING IN ENGINE ROOM. CONDUCT PROPER HYDRO TEST AFTER INSTALLATION. LEGACY COMPONENT DESC: Condition
Due 11 March 2002
Resolved 15 February 2002
Resolution: A SIX FOOT SECTION OF THE FIRE MAIN WAS RENEWED AND TESTED TO 225 PSIG.
Electrical › Electric Generation Source (service)
Issued 11 February 2002
Resolved
PROVE PROPER OPERATION OF #1, #2, AND #3 GENERATOR REVERSE POWER RELAYS. LEGACY COMPONENT DESC: Power Requirement
Due 11 March 2002
Resolved 13 February 2002
Resolution: REVERSE POWER RELAYS WERE TESTED SATISFACTORILY.
Construction/Loadline › Structures
Issued 11 February 2002
Resolved
INSTALL COAST GUARD APPROVED FIBERGLASS GRATING OR STEEL GRATING IN MUD PIT ROOM. LEGACY COMPONENT DESC: Deck Plating
Due 11 April 2002
Resolved 18 December 2002
Resolution: GRATING WAS REPLACED WITH STEEL DECK PLATING.
Documentation › Logs/Records
Issued 11 February 2002
Resolved
PROVIDE ABS STATEMENT OF FACT FOR BOTH CRANES' ANNUAL INSPECTION. LEGACY COMPONENT DESC: ABS Statement of Fact
Due 11 March 2002
Resolved 11 February 2002
Resolution: RECEIVED ABS STATEMENT OF FACT VIA FAX.
Engineering
Issued 4 January 2001
Resolved
Prove Proper operation of high jacket water alarms on #1,#2,#3 SSG
Condition: Unknown
Due 4 February 2001
Resolved 5 February 2001
Electrical
Issued 4 January 2001
Resolved
Prove proper operation of Total Rig shut-down.
Condition: Unknown
Due 4 February 2001
Resolved 5 February 2001
Engineering
Issued 4 January 2001
Resolved
Make permanent repairs to lube oil leak on #3 SSG
Condition: Unknown
Due 4 February 2001
Resolved 5 February 2001
Construction/Loadline
Issued 4 January 2001
Resolved
Make repairs to water tight door leading to the sack room
Condition: Unknown
Due 4 February 2001
Resolved 5 February 2001
Lifesaving
Issued 4 January 2001
Resolved
Properly label all general alarm bells.
Condition: Unknown
Due 4 February 2001
Resolved 5 February 2001
Electrical
Issued 5 January 2000
Resolved
REPAIR AND TEST STAND-BY GENERATOR. CONDUCT SATISFACTORY TEST OF ALL SAFETYSHUT-DOWNS.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Construction/Loadline
Issued 5 January 2000
Resolved
RENEW DOOR COAMING TO CHANGE ROOM W.T.D. WHERE WASTED. RENEW HINGES TO HATCH COVER TO PRELOAD TANK #1C.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Construction/Loadline
Issued 5 January 2000
Resolved
PRELOAD TANK #7S AND VOID #4 TO BE CLEANED AND INTERNALLY EXAMINED BY EITHER BY A MARINE INSPECTOR OR CLASS SURVEYOR.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Electrical
Issued 5 January 2000
Resolved
CONDUCT SATISFACTORY TEST OF RIGS "TOTAL RIG SHUT-DOWN" FROM ALL LOCATIONS.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Unknown
Issued 5 January 2000
Resolved
INSTALL PROPER SAFETY RELIEF VALVE ON S.S. AIR COMPRESSOR.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Lifesaving
Issued 5 January 2000
Resolved
REPLACE WASTED HAND RAILS ON THIRD LEVEL NEAR HELO DECK.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Construction/Loadline
Issued 5 January 2000
Resolved
FREE UP FROZEN / WASTED VENT CLOSURES THROUGHOUT RIG. RECONFIGURE MUD CHEMICAL SUPPLY HOSE THROUGH MAIN DECK.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Lifesaving
Issued 5 January 2000
Resolved
CONDUCT FIRE AND ABANDON DRILLS IN THE PRESENCE OF A MARINE INSPECTOR OF CLASS SURVEYOR.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Construction/Loadline
Issued 5 January 2000
Resolved
CONDUCT PHASE II OF SEILOD (UNDERWATER SURVEY) TO SATISFACTION OF COGNIZANTOCMI. SUBMIT DIVE VIDEO AND REPORT TO [name withheld].
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Fire Fighting
Issued 5 January 2000
Resolved
SERVICE SEMI-PORTABLE FIRE EXTINGUISHER NEAR ENTRANCE TO HELO DECK.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Lifesaving
Issued 7 January 1999
Resolved
Conduct 110 percent full load weight testing of both lifeboats and respective davits/winches; also perform the 110 percent load release gear test as required by 46 CFR 109.301(i)(5).
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Construction/Loadline
Issued 7 January 1999
Resolved
Crop and renew wasted overhead deck stiffeners in mud pit room stbd side overhead (underneath main deck pipe rack storage).
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Construction/Loadline
Issued 6 February 1998
Resolved
Conduct swim-by of spud cans. Provide copy of dive report and video to [name withheld].
Condition: Unknown
Due 6 February 1998
Resolved 6 February 1998
Electrical
Issued 6 February 1998
Resolved
Conduct two-hour operational test of standby generator under load and conduct semi-annual two-hour load test on emergency batteries.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Unknown
Issued 6 February 1998
Resolved
Ultrasonically test, hydrostatically test, or replace air receiver that services rig floor. Provide copy of report to [name withheld].
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Lifesaving
Issued 6 February 1998
Resolved
Comply with items (1) and (2) to enclosure (1), "Interim Policy Guidance onLifesaving Regs in 46 CFR Subchapter I-A." Log the same properly.
Condition: Unknown
Due 6 February 1998
Resolved 6 February 1998
Unknown
Issued 6 February 1998
Resolved
Complete all work-list items issued by U.S. Coast Guard on 03FEB98, prior to departing shipyard in Fourchon, LA.
Condition: Unknown
Due 6 February 1998
Resolved 9 February 1998
Construction/Loadline
Issued 9 January 1998
Resolved
No.2 starboard pre-load tank, ultrasonically test shell plating underneath bellmouth of suction line. Provide test results to [name withheld].
Condition: Unknown
Due 6 February 1998
Resolved 9 February 1998
Construction/Loadline
Issued 9 January 1998
Resolved
Submit test results and ABS survey report to [name withheld] on NDE of leg-to-can connections.
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Construction/Loadline
Issued 9 January 1998
Resolved
No.1 S.W.B.T., ultrasonically test outboard bulkhead in #2 bay, between frames 2 and 3. Ultrasoncially test shell plating underneath bellmouth of suction line. Provide test results to [name withheld] and renew wasted angle bar support under coaming entrance.
Condition: Unknown
Due 6 February 1998
Resolved 9 February 1998
Construction/Loadline
Issued 9 January 1998
Resolved
Crop and renew wasted and holed plating on sea chest to the satisfaction ofattending USCG marine inspector and/or class surveyor prior to rig move.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Construction/Loadline
Issued 9 January 1997
Resolved
CROP & RENEW WASTED OVERHEAD (DECK) FRAMING IN MUD PIT ROOM; RENEW WASTED SECTION OF SEA CHEST PIPING; RENEW WASTED FIRE MAIN PIPING @ FIRE STATION #21.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Accommodation/Occupational Safety
Issued 9 January 1997
Resolved
PLACE 100 PSI RELIEF VALVES ON HOT WATER HEATERS.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Electrical
Issued 9 January 1997
Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAY ON #2 GENERATOR AND EMERGENCYTOTAL RIG SHUT-DOWN.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Electrical
Issued 9 January 1997
Resolved
REPLACE MISSING BOLTS IN VARIOUS JUNCTION BOXES; RENEW CABLE WITH WASTED ARMOR; AND RENEW CABLE BRACKETS AS NECESSARY IN SHAKER HOUSE.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Fire Fighting
Issued 9 January 1997
Resolved
COMPLETE ANNUAL SERVICING OF ALL PORTABLE, SEMI-PORTABLE AND FIXED FIREFIGHTING EQUIPMENT.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Documentation
Issued 9 January 1997
Resolved
PROVIDE AN APPROVED EMERGENCY EVACUATION PLAN AND MAINTAIN ON BOARD.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Lifesaving
Issued 9 January 1997
Resolved
PROPERLY EQUIP AND MARK LIFEBOATS IN ACCORDANCE WITH 46CFR 107-109.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Construction/Loadline
Issued 9 January 1995
Resolved
PERFORM UNDERWATER INSPECTION OF LEG TO CAN CONNECTIONS.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Lifesaving
Issued 9 January 1995
Resolved
PERFORM FIVE YEAR HYDROSTATIC TEST OF BREATHING AIR BOTTLES IN BOTH LIFEBOATS.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Electrical
Issued 25 February 1994
Resolved
PROPERLY SECURE POWER CONDUCTORS ON DERRICK.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Electrical
Issued 25 February 1994
Resolved
PROVE PROPER OPERATION OF PURGE ALARMS ON DRILLERS CONSOLE.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Construction/Loadline
Issued 25 February 1994
Resolved
MAKE BOTH DOORS TO MUD PITS SELF CLOSING AND GAS TIGHT.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Lifesaving
Issued 25 February 1994
Resolved
STENCIL GENERAL ALARM BELLS AND LIGHTS, FIRE EXTINGUISHERS AND FIRE HOSE STATIONS AS NECESSARY.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Deck/Cargo
Issued 1 February 1991
Resolved
REPAIR ALL FUEL OIL LEAKS LOCATED ON FUEL OIL MANIFOLD IN MAIN GENERATOR ROOM.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Deck/Cargo
Issued 1 February 1991
Resolved
REPLACE TWO SECTIONS OF BILGE PIPE WITH A WELDED DOUBLER PATCH LOCATED ON BILGE LINE DIRECTLY ABOVE PORT BILGE PUMP.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Engineering
Issued 1 February 1991
Resolved
PROVIDE PROPER RELIEF VALVE FOR AIR RECEIVER LOCATED UNDER DRILL FLOOR.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Construction/Loadline
Issued 8 May 1990
Resolved
REPLACE SACK ROOM DUMP GATE VALVE DUE TO DAMAGE GATE SEAT.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Construction/Loadline
Issued 8 May 1990
Resolved
REPAIR OR REPLACE DUMP CHECH VALVE IN #7C BALLAST TANK DUE TO IMPROPER SEATING.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Construction/Loadline
Issued 14 January 1990
Resolved
MAKE ALL PRELOAD BALLEST AND VOID TANKS AVAILABLE FOR INTERNAL INSPECTION BY U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Construction/Loadline
Issued 14 January 1990
Resolved
MAKE THE CHORD TO CAN CONNECTION AVAILABLE FOR INSPECTION BY A U.S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Construction/Loadline
Issued 14 January 1990
Resolved
PERFORM MAGNETIC PARTICLE AND ULTRASONIC EXAM ON THE CHORD TO SHEAR PLAT GUSSET CONNECTIONS IN THE PRESENCE OF A U. S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Construction/Loadline
Issued 14 January 1990
Resolved
MAKE THE PRELOAD PUMPS SEA CHEST VALVES AND MUD PIT DUMP VALVES AVAILIBLE FOR INTERNAL INSPECTION BY U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Deck/Cargo
Issued 14 January 1990
Resolved
PROVIDE THIS OFFICE WITH A COPY OF THE APPROVED CONSTRUCTION PARTFOLIO.
Condition: Unknown
Due 14 January 1990
Resolved 14 January 1990
Fire Fighting
Issued 12 December 1988
Resolved
REPAIR/RENEW BOTH FIRE PUMP RELIEF VALVES AND PROVE PROPER OPERATION AT PROPER SETTING OF 160 PSI.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Lifesaving
Issued 12 December 1988
Resolved
PROVIDE 12 HAND HELD PARACHUTE FLARE-DISTRESS SIGNALLING DEVICES.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Deck/Cargo
Issued 12 December 1988
Resolved
OPEN-UP FOR INTERNAL EXAM THE FOLLOWING PRESSURE VESSELS: DRILL FLOOR AIR RECEIVER, DRY BULK TANKS 1-3 AND 5.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Deck/Cargo
Issued 12 December 1988
Resolved
PROVE PROPER OPERATION OF DRILL FLOOR AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Electrical
Issued 12 December 1988
Resolved
REPAR/RENEW EMERG... GENERATOR OVERSPEED TRIP AND PRVE PROPER OPERATION.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Deck/Cargo
Issued 4 February 1987
Resolved
COMPLETE A QUADRIENNIAL WT. TEST AND AN ANNUAL SERVICE INSPECTION ON BOTH CRANES IN ACCORDANCE WITH API RP 2D STD.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Deck/Cargo
Issued 4 February 1987
Resolved
REPAIR OR REPLACE MARK LOAD METERS ON BOTH CRANES
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Documentation
Issued 4 February 1987
Resolved
ANNUAL LOAD LINE SURVEY TO BE COMPLETED. *SEE SPECIAL INSTRUCTIONS BELOW
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Fire Fighting
Issued 4 February 1987
Resolved
TO BE COMPLETED PRIOR TO DRYDOCK EXTENSION BEING GRANTED
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Fire Fighting
Issued 4 February 1987
Resolved
PROVIDE AN ADDITIONAL OPERABLE, UL OR FM APPROVED. 02 COMBUSTIBLE GAS METERON BOARD RIG
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Lifesaving
Issued 4 February 1987
Resolved
PROVIDE TWELVE PARACHUTE SIGNAL FLARES FOR RIG
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Lifesaving
Issued 4 February 1987
Resolved
PROVIDE ADDITIONAL FIRST-AID SUPPLIES: 21 TRIANGULAR BANDAGES, 6 4" BANDAGE COMPRESSES, 3 2" BANDAGE COMPRESSES
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Construction/Loadline
Issued 4 February 1987
Resolved
REPAIR MISSING DOGS ON WATER-TIGHT DOOR, PORT SIDE, 2ND DECK LEVEL
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Lifesaving
Issued 4 February 1987
Resolved
REPLACE ALL LIFEJACKET WATER LIGHTS WITH CG APPROVED TYPE.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Deck/Cargo
Issued 4 February 1987
Resolved
MAKE OPERABLE AIR PURGE ALARM FOR DRILLERS CONSOLE
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Accommodation/Occupational Safety
Issued 4 February 1987
Resolved
PROVIDE HOT WATER HEATER WITH RELIEF VALVES SET AT NO MORE THAN 100 PSI
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Deck/Cargo
Issued 4 February 1987
Resolved
PROVIDE FORKLIFT REFUELING HOSE WITH DEADMAN NOZZEL.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Lifesaving
Issued 4 February 1987
Resolved
PROVIDE CG APPROVED CLASSIFIED LOCATIONS PLAN ABOARD RIG OR SUBMIT PLAN TO OFFICE FOR APPROVAL
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Lifesaving
Issued 4 February 1987
Resolved
POST CG APPROVED FIRE FIGHTING AND LIFESAVING PLAN ON RIG IN A CONSPICUOUSLOCATION
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Accommodation/Occupational Safety
Issued 4 February 1987
Resolved
REPAIR DISCONNECTED URNAL IN CHANGE ROOM ON MAIN DECK
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Lifesaving
Issued 4 February 1987
Resolved
PROVIDE A SEA-ANCHOR FOR EACH LIFEBOAT
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Lifesaving
Issued 4 February 1987
Resolved
TEST FIRE LINE THROWING APPLIANCE, AND LOG SAME
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Lifesaving
Issued 4 February 1987
Resolved
BOTH LIFEBOATS TO BE OPERATED IN THE WATER. *SEE SPECIAL INSTRUCTIONS BELOW
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Electrical
Issued 4 February 1987
Resolved
REPAIR AND TEST IN PRESENCE OF COAST GUARD THE HIGH WATER TEMPERATURE ALARMLOW LUBE OIL PRESSURE ALARM AND OVERSPEED TRIN FOR THE EMERGENCY GENERATOR
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Engineering
Issued 4 February 1987
Resolved
PROVIDE DRILL FLOOR AIR RECIEVER WITH A 125 LB. RELIEF VALVE MARKED WITH MANUFATURERS RELIEVING CAPACITY DATA PLATE. 46CFR 54.15-10(H)
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Unknown
Issued 4 February 1985
Resolved
SUBMIT FOR APPROVAL TO CCGD8(MMT) THE ALTERATIONS DRAWINGS FOR THE SPUD CANS.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Construction/Loadline
Issued 4 February 1985
Resolved
CROP AND RENEW THE BOW SPUD CAN BOTTOM PLATING AND ASSOCIATED INTERNALS IN WAY OF THE UPSET AREAS AND TEMPORARY REPAIRS IN THE QUADRANT INBOARD AND AFT OF THE BOW "A" CORD.
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985
Documentation
Issued 4 February 1985
Resolved
REPLACE THE CERTIFICATE OF DOCUMENTATION TO SHOW THE NEW OWNER'S ADDRESS ASREQUIRED BY 46 CFR 67.23-7(A)(1)
Condition: Unknown
Due 4 February 1985
Resolved 4 February 1985