Inspection history · 31
2 June 2008
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3225129
13 July 2007
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2993663
24 June 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2694487
27 June 2005
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2407716
1 June 2004
COI Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2084931
30 July 2003
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1862109
25 June 2003
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1826490
10 June 2002
Internal Structural Exam · COI Inspection · Cargo Tank Internal
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1626914
8 June 2001
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1362266
12 June 2000
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1466147
14 June 1999
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1395205
18 June 1998
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1446650
19 June 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1398701
18 June 1996
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404191
7 August 1995
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 878296
24 July 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1456291
20 July 1994
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1176740
30 June 1993
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1459025
20 July 1992
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 943043
29 June 1992
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 943505
24 July 1991
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1254279
5 April 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1219322
25 July 1990
COI Inspection · Deadweight Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1238803
17 July 1989
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1031547
30 June 1988
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 898866
13 June 1988
Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 889639
1 February 1988
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1323738
10 August 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1337652
10 August 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1340833
25 July 1986
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1308995
21 July 1986
Credit Drydock · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 998778
Construction/Loadline › Penetrations › Gasket
Issued 6 June 2008
No resolution recorded
Replace starboard and port nozzle gasket for #4 tanks and starboard nozzle gasket for #3 tank.
Condition: Improper/Lack of Maintenance
Due 9 July 2008 — due date passed with no resolution recorded
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 6 June 2008
No resolution recorded
Vessel needs to have onboard a valid and approved Shipboard Marine Pollution Emergency Plan
Condition: Improper/Lack of Maintenance
Due 9 July 2008 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Internal Cargo Transfer Capability
Issued 6 June 2008
No resolution recorded
Valve contol stem for tank #5 needs to be installed.
Condition: Improper/Lack of Maintenance
Due 9 July 2008 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 6 June 2008
No resolution recorded
Starboard pump packing needs to be replaced.
Condition: Improper/Lack of Maintenance
Due 9 July 2008 — due date passed with no resolution recorded
Documentation › Certificates/Documents › IOPP Certificate
Issued 6 June 2008
No resolution recorded
Vessel is missing a valid IOPP From
Due 6 July 2008 — due date passed with no resolution recorded
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 6 June 2008
No resolution recorded
Vessel is missing a letter of operations.
Due 6 July 2008 — due date passed with no resolution recorded
Documentation › Certificates/Documents › International Load Line Certificate
Issued 6 June 2008
No resolution recorded
Vessel is missing a valid Loadline certificate.
Due 6 July 2008 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 1 June 2004
Resolved
Missing explosion proof protective gage on overhead light in pump room (port-side).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 July 2004
Resolved 27 June 2005
Resolution: Verified protective cage installed correctly.
Construction/Loadline › Hull
Issued 25 June 2003
Resolved
Assess condition of hull under rub rail fractures, two on port side in way of deck manifold and one on stbd side approx in way of Nr 3 cargo tank. Photographic evidence or ultrasonic gauging report to be sufficient. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 July 2003
Resolved 8 July 2003
Navigation › Collision/Grounding Avoidance
Issued 25 June 2003
Resolved
Sandblast emergency towing bridle and provide to this office a guaging report on the condition of the tow bridle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2003
Resolved 8 July 2003
Electrical
Issued 24 July 1995
Resolved
PROVE PROPER OPERATION OF 440V AND 525V GROUND FAULT DETECTION SYSTEM.
Condition: Unknown
Due 24 July 1995
Resolved 24 July 1995
Documentation
Issued 29 June 1992
Resolved
PROVIDE CURRENT COPY OF VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY PRIORTO OPERATING IN U.S. WATERS._x001C_ _x001C_
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Construction/Loadline
Issued 25 July 1990
Resolved
MAKE PERM. REPAIRS IN STBD VOID OUTBOARD SIDE IN WAY OF FRAME #2
Condition: Unknown
Due 25 July 1990
Resolved 25 July 1990
Construction/Loadline
Issued 25 July 1990
Resolved
MAKE PERM. REPAIRS IN #4 STAR. VOID TANK IN WAY OF FRAME #2.
Condition: Unknown
Due 25 July 1990
Resolved 25 July 1990
Deck/Cargo
Issued 25 July 1990
Resolved
BARGE SHALL NOT CARRY RAIL CARS ON DECK IN U.S. WATERS UNTIL SUCH TIME AS PROPER STABILITY HAS BEEN PROVEN, AND STABILITY LETTER OUTLINING SAME HAS BEEN ISSUED BY MSC.
Condition: Unknown
Due 25 July 1990
Resolved 25 July 1990
Construction/Loadline
Issued 13 June 1988
Resolved
MAKE PERMANENT REPAIRS TO CRACK IN PORT RUBRAIL AT MIDSHIP AREA PRIOR TO 13 SEPT 88. PERMANENT REPAIRS SHALL CONSIST OF STOP ENDING, VEEING AND REWELDING BROKEN WELD NEAR VOID, PORT #5 TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Deck/Cargo
Issued 13 June 1988
Resolved
PROVIDE RESULTS OF CARGO PUMP RELIEF VALVE TEST TO THIS OFFICE WITH PROOF OF GAUGE CALIBRATION PRIOR TO CARRIAGE OF CARGO INTO U.S. WATERS.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Construction/Loadline
Issued 13 June 1988
Resolved
MAKE TEMPORARY REPAIRS TO DAMAGE IN #7 VOID AT FWD. BULKHEAD AT SHEER STRAKE. PERMANENT REPAIRS TO THIS DAMMAGE TO BE COMPLETED NO LATER THAN 13 SEPT 88. PERMANENT REPAIRS SHALL CONSIST OF AN INSERT PLATE 6" FWD OF BHD AND APX. 3 FT AFT BHD TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Construction/Loadline
Issued 13 June 1988
Resolved
MAKE TEMPORARY REPAIRS TO TOP SIDE LONG AND GUSSET IN WAY OF STERN LOG. PERMANENT REPAIRS TO BE COMPLETED NO LATER THAN 13 SEPT 88. PERMANENT REPAIRS SHALL CONSIST OF REDUCING GUSSET AND 3 FT OF TOPSIDE LONG TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Documentation
Issued 10 August 1987
Resolved
PRIOR TO THE CARRIAGE OF CARGO IN U.S. WATERS VESSEL MUST HAVE A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 10 August 1987
Resolved 10 August 1987
Construction/Loadline
Issued 10 August 1987
Resolved
MAKE PERMANENT REPAIRS IN WAY OF NO. 1 STBD CARGO TANK TOP 7 FT FROM STBD SIDE SHELL AND 3 FT FWD OF TANK ACCESS. THIS ITEM TO BE COMPLETED AT THE NEXT VESSEL DRYDOCKING AND IN NO CASE LATER THAN 21 JULY 88.
Condition: Unknown
Due 10 August 1987
Resolved 10 August 1987
Documentation
Issued 10 August 1987
Resolved
VESSEL NOT TO CARRY NOXIOUS LIQUID SUBSTANCES "I.E. CAUSTIC SODA" IN U.S. WATERS UNTIL PROCEDURE & ARRANGEMENT MANUAL HAS BEEN SUBMITTED AND RECEIVED BY U.S. COAST GUARD HEADQUARTERS G-MTH.
Condition: Unknown
Due 10 August 1987
Resolved 10 August 1987
Unknown
Issued 21 July 1986
Resolved
MAKE PERMANENT REPAIRS (CROP AND INSERT) AND REMOVE DOUBLER IN WAY OF PORT AFT RAKE SIDE SHELL DECK KNUCKLE AND HOSE TEST REPAIR.
Condition: Unknown
Due 21 July 1986
Resolved 21 July 1986
Unknown
Issued 21 July 1986
Resolved
SATISFACTORLY HYDRO TEST THE ON-DECK CARGO PIPING TO 90 PSI.
Condition: Unknown
Due 21 July 1986
Resolved 21 July 1986
Unknown
Issued 21 July 1986
Resolved
MAKE PERMENANT REPAIRS TO CARGO TANK VENT IN WAY OF #1 PORT WING VOID AND PROVE SAME BY HYDRO TEST.
Condition: Unknown
Due 21 July 1986
Resolved 21 July 1986