MAURY USCG vessel records Sign in
← All vessels

SIGLOO FINN

SIGLOO FINN is a 1981 tank ship. The Coast Guard has recorded 49 inspections since 1985, most recently in January 2010, along with 37 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 1985 to 2010. Most recent: inspection, 12 January 2010.

Built
1981
Last inspected
12 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8000989 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SINGAPORE
—
Maury page id
psix-54098

Inspections, by type

…with no type recorded21
…past their stated due date1
Years with a record 18 calendar years (1985–2010)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8630 - Convention (Subpart B), Gross Ton
2589 - Convention (Subpart B), Net Ton
11665 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 49

12 January 2010 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3685289
8 January 2010 ISPS III Exam · COC-GAS Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3658882
14 July 2009 ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3527345
4 May 2009 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3467124
6 January 2009 MARPOL Annex V Examination · ISPS III Exam · COC-GAS Renew · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3387567
29 October 2008 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS III Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3378088
17 July 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3268455
15 July 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3268458
18 April 2008 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3187019
20 February 2008 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3148573
22 January 2008 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · COC-GAS Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3132920
26 September 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3067651
12 April 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2906495
17 March 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2887036
1 March 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2880016
19 January 2007 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2856039
2 January 2007 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2846249
13 January 2005 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2275112
11 January 2003 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1728915
10 January 2003 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1727521
8 January 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1728911
2 December 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 490860
2 December 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 772728
21 June 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 279089
21 June 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 819575
23 September 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395672
23 September 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1132716
24 July 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 380934
6 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 461859
11 December 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 20203
12 July 1994 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 866198
5 July 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 864130
6 January 1994 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 853849
5 August 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 359929
27 July 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 359691
2 July 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1157277
13 October 1992 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 353642
25 July 1992 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1251759
20 April 1990 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1213896
12 July 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 469258
26 November 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 442059
26 November 1987 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1026488
8 October 1987 Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1012712
24 December 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 502062
24 December 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1000838
19 December 1986 Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004973
2 November 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 305644
2 November 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 990025
9 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288903

Deficiency record · 37

Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 8 January 2010 No resolution recorded
Cargo Tank Domes 1,2,3,4 and 6 have broken pressure relief valve seals. To ensure prescribed valve are set to relieve at appropriate pressure settings, valves must be re-set and sealed by a competent authority and/ or verified by class society as correctly set.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2010 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 July 2009 Resolved
During test of the oily water seperator (ows) the oil content moniter (ocm) showed alarm of cell breach of ocm. The ows manual states "measuring cell has been opened; replace measuring cell." Vessel is restricted from using ows until measuring cell has been replaced, tested, and verified by class. MARPOL 73/78 ANNEX I REG 14
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 August 2009
Resolution: Received Class Report from DNV satisfying the requirement.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 4 May 2009 Resolved
Recieved report on 03MAY2009, THAT THE STARBOARD SIDE ANCHOR WAS FOUND MISSING. Class report was given and the anchor must be replaced by 24JUL2009
Action required: 705 - Other - as specified
Due 24 July 2009
Resolved 12 May 2009
Resolution: Received class report attesting to the replacement of the starboard anchor and joining shackle have been successfully replaced.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 29 October 2008 Resolved
Vessel has a cargo leak of VCM at 4-10ppm in compressor room. Cause is unknown. Due to leak space is unsafe for entry by USCG personnel, and unable to complete safety exam until leak is found and fixed. Vessel is restricted form conducting cargo until exam is completed. Rectify prior to departure from port
Action required: 705 - Other - as specified
Resolved 1 November 2008
Resolution: Received class report attesting to the satisfactory repair of the leak in the compressor room, a marine chemist also attended and cleared the space safe for workers, prior to CG attendance.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 23 January 2008 Resolved
Water spray nozzles above #2 & #6 cargo tanks as well as several nozzles on superstructure do not provide adequate water spray protection. SOLAS 74 (2004 Consol. Ed.) Ch. VII/12 - Gas Code XI/11.3.2 To the satisfaction of the Coast Guard Marine Inspector.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 February 2008
Resolution: Coast Guard Inspectors witnessed satisfactory test of all nozzles for deck water spray system.
Lifesaving › Launching Appliances › Block
Issued 23 January 2008 Resolved
Stop pads on both port & starboard davits for lifeboats are rotted and allowing the mounting hardware to wear on both lifeboats. SOLAS 60 III/4
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2008
Resolved 20 February 2008
Resolution: PSCOs verified Class report attesting to satisfactory replacement, test and operation of port & starboard lifeboat mounting hardware.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 23 January 2008 Resolved
Head gasket on vessel's main propulsion engine #3 cylinder leaking water. SOLAS 60 I/11
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2008
Resolved 20 February 2008
Resolution: PSCOs verified satisfactory Class report attesting to satisfactory test/operation of #3 cylinder head gasket.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 January 2008 Resolved
Fuel day tank for diesel engine to emergency fire pump does not have a remote means to secure the fuel from outside the space. SOLAS 60 II/69(a)
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2008
Resolved 18 April 2008
Resolution: Received class report from DNV satisfying the requirement.
Navigation › Piloting/Steering › Gyro Compass
Issued 26 September 2007 Resolved
Inbound: 26SEP07 The vessel was granted a Letter of Deviation to enter the Port of Corpus Christi with an inoperable Gyro Compass. The following restrictions are required: daylight transit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Resolution: 28 SEP 2007: After reviewing the technician''s report from [name withheld], the restriction on the vessel is released.
Deck/Cargo › Inert Gas System › Deck Mechanical Non-Return Valve
Issued 2 January 2007 Resolved
Double block and bleed valve on IGS is not approved by the USCG. Request for approval must be made in 30 days.
Action required: 705 - Other - as specified
Due 2 February 2007
Resolved 2 January 2007
Resolution: Deficiency was entered in error. Requirements not applicable to vessel due to build date.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 2 January 2007 Resolved
Cargo Record Book revisions not entered in reference to MARPOL Annex II revisions.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 January 2007
Resolution: Cargo Record Book for NLS in bulk now revised to reflect MARPOL Annex II provisions.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 2 January 2007 Resolved
Vapor recovery markings at manifold are worn and indistinct.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 January 2007
Resolution: Vapor recovery piping on deck is now painted with new markings.
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 2 January 2007 Resolved
Revised P & A Manual not onboard with receipt of acknowledgement of submittal.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Final Approved Procedures and Arrangements manual dated 04Jan07 is now provided onboard.
Fire Fighting › Firemans Outfit
Issued 10 January 2003 Resolved
Provide tech. report attesting to the proper operation of SCBA low pressure alarms on all SCBA's throughout ship LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Due 17 January 2003
Resolved 23 January 2003
Resolution: repair
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 10 January 2003 Resolved
During next drydock exam, replace faulty pressure gauge IWO compressor room cylinder #291814 by recommendation of UNICOR LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Resolved 23 January 2003
Resolution: replace and repaired
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 10 January 2003 Resolved
Provide Class report to the proper operation of unclogged nozzles on Deck Spray System LEGACY COMPONENT DESC: Nozzles
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2003
Resolution: Cleared as per DNV Survey Report of 11JAN03. "Deck spray system was tested and found in order.
Electrical › Electric Generation Source (emergency)
Issued 10 January 2003 Resolved
Prior to departure, provide class report attesting to proper operation of both battery starting systems for emergency generator. LEGACY COMPONENT DESC: Generator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2003
Resolution: replace all exsisting batteries for generator
Deck/Cargo › Cargo Refrigeration
Issued 10 January 2003 Resolved
Prior to cargo operations, provide class report attesting to the proper operation of compressors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2003
Resolution: Cleared as per DNV Survey Report on 11JAN03. "Pneumatically controlled valve for cargo condensers cooling system was reportedly repaired. Short running test of the compressors was carried out
Deck/Cargo › Holds/Tanks
Issued 10 January 2003 Resolved
Provide class report attesting to the proper operation of the gas detection system. LEGACY COMPONENT DESC: Fixed Gas Detection
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2003
Resolution: Cleared as per DNV Survey Report of 11JAN03. "Gas detecting system was repaired by the crew and tested with satisfactory results.
Pollution Prevention/Response › Prevention Equipment
Issued 10 January 2003 Resolved
Provide Class report attesting to the proper operation of emergency shutdown and quick closing valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2003
Resolution: Cleared as per DNV Survey Report of 11JAN03. "Emergency shut down system including quick closing valves was tested and found in order"
Pollution Prevention/Response › Prevention Equipment
Issued 10 January 2003 Resolved
Provide class report attesting to the proper operation of temperature alarms
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2003
Resolution: Cleared as per DNV Survey Report of 11JAN03. "Cargo temperature alarms were tested in the presence of the undersigned and found in order.
Deck/Cargo › Cargo Refrigeration
Issued 10 January 2003 Resolved
Provide class report attesting to the condition of water-cooling condensers #1 - #3 IWO compressor room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2003
Resolution: insulation was repaired, no leaks detected.
Pollution Prevention/Response › Prevention Equipment
Issued 10 January 2003 Resolved
Remove paint from safety relief valve identification labels.
Due 17 January 2003
Resolved 23 January 2003
Resolution: paint was remove from label
Lifesaving › Visual Distress Signals (General)
Issued 10 January 2003 Resolved
Provide documentation to the expiration of the hydrostatic release for EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2003
Deck/Cargo
Issued 21 June 2000 Resolved
REPAIR SELF CLOSING OUTSIDE DOOR TO AIR LOCK TO MOTOR ROOM PRIOR TO CONDUCTING CARGO OPS.
Condition: Unknown
Due 21 July 2000
Resolved 22 June 2000
Deck/Cargo
Issued 21 June 2000 Resolved
PROVE PROPER OPERATION OF THE VISUAL OVERFILL ALARM ON THE MAIN DECK PRIOR TO CARRIAGE OF CHEMICALS REQUIRING THE ALARM TO THE SATISFACTION OF THE CERTIFICATE ISSUEING AUTHORITY BUT NOT LATER THAN 21JUL00.
Condition: Unknown
Due 21 July 2000
Resolved 22 June 2000
Fire Fighting
Issued 21 June 2000 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP PRIOR TO CONDUCTING CARGOOPERATIONS OR PROVIDE ALTERNATE MEANS OF SUPPLYING WATER TO THE VESSEL.
Condition: Unknown
Due 21 July 2000
Resolved 22 June 2000
Documentation
Issued 24 July 1995 Resolved
PROVIDE FLAG ADMINISTRATION DOCUMENTATION STATING COMPLIANCE WITH THE U.S. DOUBLE HULL STANDARDS LISTED IN 33CFR157.10(d) AS REQUIRED BY 33CFR157.24
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Deck/Cargo
Issued 6 January 1994 Resolved
PRIOR TO VAPOR COLLECTION OPERATIONS IN U.S. WATERS, CALIBRATE OR REPLACE PRESSURE GAUGE IN WAY OF #4C & #6C CITS COMMON VCS CONNECTION MANIFOLD ON PORTSIDE.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Deck/Cargo
Issued 6 January 1994 Resolved
PRIOR TO VAPOR COLLECTION OPERATIONS IN U.S. WATERS, REPOSITION STUD CONNECTION IAW 46CFR39.20-1(e) ON #4C & #6C VCS MANIFOLDS ON PORT & STARBOARD SIDES.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Deck/Cargo
Issued 6 January 1994 Resolved
PRIOR TO VAPOR COLLECTION OPERATIONS IN U.S. WATERS, INCORPORATE INFORMATION FOR VAPOR COLLECTION SYSTEM IN OIL TRANSFER PROCEDURES AS REQUIRED BY 33CFR155.750(d).
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Deck/Cargo
Issued 6 January 1994 Resolved
PRIOR TO VAPOR COLLECTION OPERATIONS IN U.S. WATERS, PERMANENTLY AFFIX ALL STUD CONNECTIONS ON VCS MANIFOLDS #1-6.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Deck/Cargo
Issued 6 January 1994 Resolved
PRIOR TO VAPOR COLLECTION OPERATIONS IN U.S. WATERS, INSTALL VAPOR PRESSURESENSING DEVICE AS REQUIRED BY 46CFR39.20-13 ON ALL VCS MANIFOLDS.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Lifesaving
Issued 2 July 1993 Resolved
PROVE PROPER OPERATION OF DRAEGER PUMPS.
Condition: Unknown
Due 2 July 1993
Resolved 30 July 1993
Navigation
Issued 2 July 1993 Resolved
PROVE PROPER OPERATION OF VESSEL'S 10 CM ARPA RADAR.
Condition: Unknown
Due 2 July 1993
Resolved 30 July 1993
Lifesaving
Issued 2 July 1993 Resolved
HAVE VESSEL'S SELF CONTAINED BREATHING APPARATI PROFESSIONALLY SERVICED PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 2 July 1993
Resolved 30 July 1993
Engineering
Issued 2 November 1985 Resolved
HYDROSTATICALLY TEST THE FUEL OIL PIPING SYSTEM TO 1.5 MAWP IN ACCORDANCE WITH 33 CFR 156.170(C)(4).
Condition: Unknown
Due 2 November 1985
Resolved 2 November 1985