Records from 1987 to 1998. Most recent: inspection, 20 October 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
20 October 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 421718
4 September 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 419898
4 September 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 801660
24 March 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 349827
21 September 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 520457
29 March 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 342758
1 December 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 906871
26 November 1990
Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1217567
20 August 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 465579
8 February 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 335243
2 May 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 330101
27 April 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 329970
21 January 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 327934
19 January 1989
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 892050
25 March 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 322189
25 March 1988
Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1297369
4 November 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 319436
28 August 1987
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1034988
14 August 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 466187
14 August 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1001111
26 May 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1026422
18 January 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 450627
14 January 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 313747
7 January 1987
Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1322694
Navigation
Issued 4 September 1998
Resolved
Repair/replace inoperative circuitbraker on #1 steering gear pump prior to next U.S. port from overseas. SOLAS 60 chpt II Reg 30
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Electrical
Issued 4 September 1998
Resolved
Remove/replace the improper light installation behind engine control room main switchboard, prior to next U.S. port from overseas. SOLAS 60 Chpt II reg 27.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Deck/Cargo
Issued 4 September 1998
Resolved
Repair/replace drying unit in No. 2 anchor windless, the heat lamp rigged below the electrict motor. Prior to returning to the U.S. from overseas._x001C_ SOLAS 60 Chpt II Reg. 23
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Fire Fighting
Issued 4 September 1998
No resolution recorded
Repair the hole in deck fire main drain line, portside, outboard of cargo pumproom deck house. Prior to returning to the U.S. from overseas port. SOLAS 60 Chpt II, Reg 56
Condition: Unknown
Due 6 September 1998 — due date passed with no resolution recorded
Engineering
Issued 4 September 1998
Resolved
Engine room soft patches. a) Soft patch on main engine lube oil cooler water supply and discharge lines. b) soft patch on turbo charger lube oil cooks water supply line. c) soft patch on seawater supply line for fresh water evaporator. repair prior to next u.s. port from overseas.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Fire Fighting
Issued 4 September 1998
Resolved
Repair the hole in the class A fire bulkhead of engineroom control room prior to next U.S. port from overseas. SOLAS 60 CHPT II reg 35 (c)(iii).
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Documentation
Issued 29 March 1991
Resolved
DANGEROUS CARGO MANIFEST DOES NOT CONTAIN OFFICIAL NUMBER 49CFR176.30(a)(1)
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Documentation
Issued 29 March 1991
Resolved
DANGEROUS CARGO MANIFEST DOES NOT CONTAIN PROPER IDENTIFICATION NUMBER FOR HAZARDOUS MATERIAL ON BOARD 49CFR176.30(a)(3).
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Documentation
Issued 29 March 1991
Resolved
DANGEROUS CARGO MANIFEST DOES NOT CONTAIN THE CLASSIFICATION OF THE _x001C_ HAZARDOUS MATERIAL 49CFR176.30(a)(5).
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Documentation
Issued 29 March 1991
Resolved
DANGEROUS CARGO MANIFEST DOES NOT CONTAIN SIGNATURE FOR MASTER OR A LICENSED DECK OFFICER.
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Engineering
Issued 29 March 1991
Resolved
OILY WATER SEPARATOR ALARM INOPERABLE 33CFR155.380(B)
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Documentation
Issued 29 March 1991
Resolved
DANGEROUS CARGO MANIFEST DOES NOT CONTAIN PREPARERS SIGNATURE 49CFR176.30(b).
Condition: Unknown
Due 29 March 1991
Resolved 29 March 1991
Navigation
Issued 21 January 1989
Resolved
CHART 18645, 19TH ED., 24NOV84, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1985-6
Condition: Unknown
Due 21 January 1989
Resolved 21 January 1989
Navigation
Issued 21 January 1989
Resolved
CURRENT EDITION TIDAL CURRENT TABLES NOT ON BOARD.
Condition: Unknown
Due 21 January 1989
Resolved 21 January 1989
Navigation
Issued 21 January 1989
Resolved
US LIGHT LIST, VOL VI, 1987, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1987-1,5,6,9,12,14,15,16,17,18,19,20,21,23,24,25,26,27,28,29,31,33,34,35,37,38,39,40,41,42,43,47,50.
Condition: Unknown
Due 21 January 1989
Resolved 21 January 1989
Navigation
Issued 21 January 1989
Resolved
CHART 18649, 52ND ED, 18OCT86, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS:1987-7,10,15,16,19,21,23,24,29,33,34,35,37, 44,46. 1988-37
Condition: Unknown
Due 21 January 1989
Resolved 21 January 1989
Deck/Cargo
Issued 19 January 1989
Resolved
PROVIDE TOXIC DETECTOR TUBES FOR ALL CARGOES AUTHORIZED TO CARRY BY SOE WHERE REQ'D BY TABLE 1 OF SUBCHAPTER "O".
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Deck/Cargo
Issued 19 January 1989
Resolved
STENCIL DATE OF MANUFACTURE AND MAX/MIN TEMP ON ALL PORTABLE CARGO HOSES.
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Navigation
Issued 14 January 1987
Resolved
VESSEL HAS THE FOLLOWING LATEST EDITION CHARTS OF THE COLUMBIA RIVER THAT CONTAIN NO CORRECTIONS FROM NOTICE TO MARINERS. 18521 55TH ED 26OCT85 18523 42ND ED. 09FEB85, 18524 22ND ED. 27APR85, AND 18526 43RD ED. 17MAR84.
Condition: Unknown
Due 14 January 1987
Resolved 14 January 1987
Deck/Cargo
Issued 7 January 1987
Resolved
PROVIDE APPROPRIATE TOXIC VAPOR DETECTORS PRIOR TO CARRIAGE OF THOSE CARGOES REQUIRING TOXIC VAPOR DETECTORS.
Condition: Unknown
Due 7 January 1987
Resolved 7 January 1987
Deck/Cargo
Issued 7 January 1987
Resolved
PRIOR TO CARRIAGE OF MORPHOLINE IN THE CENTER LINE CARGO TANKS OBTAIN CLEARANCE FROM COMMANDANT (G-MTH).
Condition: Unknown
Due 7 January 1987
Resolved 7 January 1987
Fire Fighting
Issued 7 January 1987
Resolved
MAKE PERMANENT REPAIRS TO THE FIREMAIN EXPANSION JOINT IN WAY OF #4 CENTER CARGO TANK, PRIOR TO NEXT VOYAGE TO THE UNITED STATES.
Condition: Unknown
Due 7 January 1987
Resolved 7 January 1987
Fire Fighting
Issued 7 January 1987
Resolved
MAKE PERMANENT REPAIRS TO THE FOAM FEED LINE IN THE WAY OF #4 CENTER CARGO TANK PRIOR TO NEXT VOYAGE TO THE UNITED STATES.
Condition: Unknown
Due 7 January 1987
Resolved 7 January 1987