Records from 1982 to 2009. Most recent: inspection, 8 January 2009.
Inspection history · 166
8 January 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3390813
25 October 2008
Type not recorded
No type recorded · Activities Europe · Activity 3374678
28 August 2008
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3310994
26 June 2008
Drydock Extension
Administrative · Commandant (CG-CVC) · Activity 3249047
28 April 2008
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3229132
20 March 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3168547
5 March 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3158789
30 January 2008
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3138699
15 January 2008
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3122278
4 December 2007
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3110297
12 November 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3097123
29 October 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3089094
4 September 2007
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3048931
22 July 2007
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3003462
16 July 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3001561
30 October 2006
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2786755
25 July 2006
Cargo Tank Internal · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2724532
4 October 2005
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2507123
14 June 2005
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2491425
14 April 2005
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2342674
7 April 2005
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2328919
2 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2302295
27 January 2005
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2292262
20 December 2004
Periodic Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2190646
9 December 2004
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2256198
24 November 2004
MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2247479
8 October 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2217048
29 September 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2208753
8 September 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2190607
21 August 2004
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2172247
13 June 2004
MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2091618
13 January 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1980518
2 January 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1973726
16 September 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1906413
12 August 2003
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 1874396
8 August 2003
Cargo Tank Internal
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1870397
28 July 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1860012
25 July 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1859832
1 July 2003
Cargo Tank Internal · Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1826913
4 June 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1809866
21 May 2003
Cargo Tank Internal
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1821017
24 January 2003
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1734656
10 January 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1728727
10 October 2002
Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1695181
9 August 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1661910
3 April 2002
Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1600808
11 March 2002
Security Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1492924
4 February 2002
MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1483868
15 November 2001
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1076225
31 October 2001
Hull Examination · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1366485
27 May 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 29581
27 May 2001
Permit to Proceed
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1397653
9 October 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1057237
21 July 2000
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1412141
17 July 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1052021
14 October 1999
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1416976
24 September 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1033819
16 September 1999
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1462779
11 January 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 424470
17 November 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1423101
30 July 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1423053
25 July 1998
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1383934
15 June 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1126606
27 March 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 787841
17 February 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1113350
8 January 1998
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 411789
22 December 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1120718
13 December 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 782845
12 December 1997
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 779502
18 November 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 773525
22 September 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1112723
18 September 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1112656
1 September 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 43867
29 August 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1120902
24 August 1997
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1416537
2 July 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 36258
28 May 1997
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1108895
9 April 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1101019
3 April 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 89551
10 December 1996
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1097654
15 November 1996
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1174738
16 October 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1467944
7 August 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1371506
29 June 1996
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1367819
16 June 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1466426
12 April 1996
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1380467
3 January 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 86297
10 October 1995
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1449860
24 July 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 443577
20 March 1995
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1180613
24 December 1994
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 540215
17 November 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1178227
28 September 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1422420
6 September 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 860903
18 August 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 220069
18 August 1994
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1450882
17 August 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 105316
13 August 1994
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 870111
21 July 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 83225
7 July 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 108602
14 January 1994
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1164213
8 January 1994
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 78006
1 November 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 443302
19 October 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1150745
9 October 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1162536
11 September 1993
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 844823
28 August 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 845259
21 August 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1140128
22 July 1993
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1133239
9 July 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845382
9 June 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1148323
26 April 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 358025
9 April 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 669019
8 April 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 516957
11 October 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1255026
30 September 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 669021
16 September 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1248608
4 September 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1444690
24 August 1992
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1139052
30 July 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 43048
14 May 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 524182
21 November 1991
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 669014
28 October 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 952059
16 October 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 940964
4 October 1991
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 501764
2 October 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1266989
26 September 1991
Hull Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 944107
3 September 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1267577
4 February 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 500219
5 November 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1240022
5 October 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242319
31 August 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1241982
22 August 1990
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1211618
28 July 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 442027
11 July 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 915894
29 June 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920916
13 May 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 337128
2 May 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 336837
15 March 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 504160
17 November 1989
Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 904400
14 March 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 328970
1 March 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 471220
16 February 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1278022
18 October 1988
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 886463
4 October 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195656
22 September 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 325749
31 August 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1043968
6 May 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 323083
26 April 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 479518
16 November 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1027017
16 November 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334753
19 June 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1009527
1 May 1987
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323746
1 March 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312338
10 October 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 475769
15 September 1986
COI Inspection · Credit Drydock
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1010172
28 May 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1293846
11 April 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 308025
3 April 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 998247
8 February 1986
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294858
7 February 1986
MARPOL Annex I Examination · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294697
17 July 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 491143
9 May 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1291029
17 August 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1284290
9 August 1983
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 963539
21 June 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 963289
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 15 January 2008
Resolved
Repair port side MDE local alarm panel.
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 30 January 2008
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 15 January 2008
Resolved
Provide valve position indicator for main salt water valve on Inert Gas System.
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 30 January 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 January 2008
Resolved
Repair STBD side OWS, use of OWS is resticted.
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 30 January 2008
Engineering › Sea-water System (primary cooling) › Pump
Issued 4 December 2007
Resolved
Repair/replace starboard (#1) cooling water pump for barge machinery. Barge fire pump is acceptable temporary means for second cooling water pump needed for barge equipment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 January 2008
Resolved 14 January 2008
Resolution: Rebuilt pump.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 22 July 2007
Resolved
Conduct permanent repairs through cropping and renewing 42" by 24" plate in way of hole in wasted/pitted area between #3 center cargo tank and #3 port ballast wing tank forward of frame 49. Vessel is permitted to proceed to Rodeo, CA (Sector San Francisco) to discharge cargo then to proceed to Port Angeles, WA to complete permanent repairs with no other deviations in route.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2007
Resolved 6 August 2007
Resolution: Inserted Bkld. Old pad eye weldment fracture. Repairs completed.
Lifesaving › Lifeboat Equipment › Pump (manual)
Issued 30 October 2006
Resolved
Repair broken bilge pump on starboard lifeboat.
Action required: 705 - Other - as specified
Due 7 November 2006
Resolved 2 November 2006
Resolution: Replaced
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 30 October 2006
Resolved
Demonstrate proper operation of the breathing air bottles on both port and starboard lifeboats.
Action required: 705 - Other - as specified
Due 7 November 2006
Resolved 2 November 2006
Resolution: Demonstrated.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 30 October 2006
Resolved
Replace expired medicines in both port and starboard lifeboat first aid kits.
Action required: 705 - Other - as specified
Due 7 November 2006
Resolved 2 November 2006
Resolution: REplaced with new kits.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 30 October 2006
Resolved
Repair/replace the damaged water spray nozzles on both port and starboard lifeboats.
Action required: 705 - Other - as specified
Due 7 November 2006
Resolved 2 November 2006
Resolution: Replaced with new nozzles.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 30 October 2006
Resolved
Repair/replace 3 inoperable emergency lights in the tug house and 1 in the barge engine-room.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 30 October 2006
Resolution: Corrected by replacement while on-board during inspection.
Lifesaving › Lifeboat › Safety Belt
Issued 30 October 2006
Resolved
Fasten the cox'n seat for the port lifeboat securely to the boat top.
Action required: 705 - Other - as specified
Due 7 November 2006
Resolved 30 October 2006
Resolution: The bolts holding the top of the seat bracket were missing and broken. Repaired while on board during inspection.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 30 October 2006
Resolved
Renew ODME USCG Approval document.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 14 November 2006
Resolution: The ODME approval is still expired as of this date. The equipment is operating satisfactorily and has been tested by a qualified 3rd party. LA-LB is seeking a solution with D11/PacArea and G-PCV-1 for this situation.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 30 October 2006
Resolved
Install open/close indicator on the Inert Gas System discharge to atmosphere valve.
Action required: 705 - Other - as specified
Due 7 November 2006
Resolved 2 November 2006
Resolution: New valve installed.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 30 October 2006
Resolved
Hydro-test the 62-9011-2 boiler and remove the mounts for inspection. This must be completed by 15 Nov 2006 or next arrival at LA-LB.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 8 November 2006
Resolution: Hydro tested sat. Mounts inspected sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 October 2006
Resolved
Replace 5 type 1 lifejackets.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2006
Resolved 30 October 2006
Resolution: Corrected while onboard. The rejected lifejackets were all of the KAPOK type and had ruptured internal bags.
Engineering › Pressure Vessel › Relief Valve
Issued 20 December 2004
Resolved
Provide operable relief valves for both port and starboard soot blower air tanks located in the stack spaces.
Action required: 705 - Other - as specified
Due 23 December 2004
Resolved 23 December 2004
Resolution: New 125 psi relief valves were installed on both soot blower air receivers.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Drum Safety
Issued 20 December 2004
Resolved
Provide 2 operable steam safety valves for the auxiliary boiler located in the tug starboard engine room.
Action required: 705 - Other - as specified
Due 23 December 2004
Resolved 23 December 2004
Resolution: Valves were sent ashore to be repaired and tested in Long Beach, CA.
Construction/Loadline › Structures
Issued 1 July 2003
Resolved
Repair wasted and broken ladder brackets in #4 stbd double bottom tanks
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 7 August 2003
Resolution: Ladder brackets repaired.
Construction/Loadline
Issued 1 July 2003
Resolved
Repair tripped gusset in #3 stbd double bottom tank in fwd outboard bay
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 7 August 2003
Resolution: Tripped gusset repaired.
Engineering
Issued 1 July 2003
Resolved
repair hydraulic leak in fed cofferdam on barge
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 7 August 2003
Resolution: Leak repaired.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 13 January 2003
Resolved
Demonstrate operation of the barge auxiliary boiler, including alarms and shutdowns. The auxiliary boiler was not operational during the original inspection due to a blower failure discovered during maintenance testing.
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 8 February 2003
Resolution: Boiler operation demonstrated.
Engineering › Diesel Engine (auxiliary)
Issued 13 January 2003
Resolved
Demonstrate low lube oil shutdown, jacket water high temperature alarm and overspeed shutdown on the #3 (CAT) cargo pump prime mover diesel engine in the barge. Regular rounds must be made on the engine to determine its operating condition when-ever its is running, until this item is corrected.
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 8 February 2003
Resolution: Alarms tested.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 13 January 2003
Resolved
Demonstrate the high jacket water alarm on the barge electrical generator.
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 8 February 2003
Resolution: Alarm tested.
Engineering › Compressed Air System (start air)
Issued 13 January 2003
Resolved
Test the relief valves on the barge air receiver and both barge air compressor oil seperator receivers. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 8 February 2003
Resolution: Relief valves tested.
Pollution Prevention/Response › Prevention Equipment
Issued 13 January 2003
Resolved
Re-pipe both the port and starboard engine room oily water separators as original. All suction and discharge piping on the oily water separators is currently disconnected rendering them not operational. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 8 February 2003
Resolution: Both oil water separators re-piped.
Fire Fighting › Miscellaneous Items
Issued 10 January 2003
Resolved
Upper paint locker is rusted and holed. either replace or rnew to comply w/ 46 CFR 32.85. Remove flammables until the paint locker is permananently repaired. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 8 February 2003
Resolution: Upper paint locker removed.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 10 January 2003
Resolved
Fire extinguishers connected to both the upper and lower paint lockers do not appear to be serviced. Provide proof of servicing.
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 8 February 2003
Resolution: Extinguishers serviced.
Construction/Loadline › Penetrations
Issued 10 January 2003
Resolved
There is a cable passing through a portlight bolthole on the 2nd deck, port side, forward bulkhead of the house. Remove cable and replace bolt to renew gastightness.
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 8 February 2003
Resolution: Penetration sealed.
Lifesaving
Issued 16 September 1999
Resolved
Replace door seals on both doors on stbd lifeboat.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Lifesaving
Issued 16 September 1999
Resolved
Repair cracked fiberglass on lip of stbd lifeboat in way of port door.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Lifesaving
Issued 16 September 1999
Resolved
repair exhaust hose insulation of stbd lifeboat.
Condition: Unknown
Due 25 September 1999
Resolved 21 September 1999
Lifesaving
Issued 16 September 1999
Resolved
Replace alternate bilge hose on inside aft of stbd lifeboat.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Lifesaving
Issued 16 September 1999
Resolved
Install fire bottle bracket in stbd lifeboat (small fire extinquisher).
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Deck/Cargo
Issued 16 September 1999
Resolved
Prove proper operation of main deck audible overfill alarm.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Documentation
Issued 16 September 1999
Resolved
Provide correct trim & stability book (J.J. [name withheld] #6771 dtd 18JUL83) as per 30 August 1983 stability ltr.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Documentation
Issued 16 September 1999
Resolved
Provide on board USCG approval ltr and information on vsls vapor control toensure as per page two of vsls Certificate of Inspection.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Deck/Cargo
Issued 16 September 1999
Resolved
Label high level alarm & overfill alarm iaw 46 CFR 39.20.7 (c) & (d).
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Lifesaving
Issued 16 September 1999
Resolved
Replace and prove proper operation of stbd lifeboat morse control cable forforward and reverse.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Engineering
Issued 16 September 1999
Resolved
Prove proper operation of port enginroom space oily water separator.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Lifesaving
Issued 16 September 1999
Resolved
Remove loose gear stowed behind electric switchboard with open bus bar in the aft section of the cargo control room on the barge.
Condition: Unknown
Due 16 October 1999
Resolved 21 September 1999
Electrical
Issued 17 November 1998
Resolved
Vessel to repair/replace the stbd ships service generator prior to departing port of New York.
Condition: Unknown
Due 19 November 1998
Resolved 23 November 1998
Engineering
Issued 17 November 1998
Resolved
vessel to complete repairs to port main engine exhaust system prior to departing port of New York.
Condition: Unknown
Due 17 November 1998
Resolved 23 November 1998
Deck/Cargo
Issued 25 July 1998
Resolved
TEST CARGO PUMP EMERGENCY SHUTDOWNS TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Accommodation/Occupational Safety
Issued 25 July 1998
Resolved
PROVE PROPER OPERATION SAFETY RELIEF VALVES FOR AIR RECEIVERS IN STARBOARD ENGINE ROOM TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Deck/Cargo
Issued 25 July 1998
Resolved
PROVE PROPER OPERATION OF BARGE MACHINERY TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Fire Fighting
Issued 25 July 1998
Resolved
TEST FIXED CO2 EXTINGUISHING SYSTEM IN THE PRESENCE OF A COAST GUARD MARINEINSPECTOR
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Deck/Cargo
Issued 25 July 1998
Resolved
TEST IGS TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Electrical
Issued 12 December 1997
Resolved
Vessel to have a tug in attendance while maneuvering within New York Harboron one ship's service generator. Chief Engineer to FAX certification to above number that both ship's service generators are in normal operating condition prior to departing the Port of New York.
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Engineering
Issued 18 September 1997
Resolved
Vessel may enter port of NY on one engine to conduct maintenance on the stbd engine. For any movements within the port of NY, vsl must have a standby tug in attendence in all waters north of the VZ-Narrows Bridge and Outerbridge crossing. Vsl must depart port of NY on both engines.
Condition: Unknown
Due 22 September 1997
Resolved 22 September 1997
Documentation
Issued 24 August 1997
Resolved
MARK BARGE FWD BOSN STORE FIRE STATION IAW FIRE CONTROL PLAN. (STATION 7 ON FIRE CONTROL PLAN?). THERE IS A SECOND PORTABLE FIRE EXTINGUISHER MOUNTED ON DECK. REMOVE IT, OR CORRECTLY MOUNT IT AND ADD TO FIRE CONTROL PLAN.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Deck/Cargo
Issued 24 August 1997
Resolved
REPLACE OXYGEN METER ON IGS PANEL BOARD
Condition: Unknown
Due 26 August 1997
Resolved 25 August 1997
Engineering
Issued 24 August 1997
Resolved
ON ALL FUEL AND LUBE OIL SYSTEMS UNDER PRESSURE AND NEAR HOT SURFACE, FIX OR INSTALL MISSING FLANGE SHIELDS
Condition: Unknown
Due 26 August 1997
Resolved 25 August 1997
Fire Fighting
Issued 24 August 1997
Resolved
ON DECK MONITOR NR TWO, EQUIP WITH PROPER SPANNER
Condition: Unknown
Due 24 August 1997
Resolved 24 August 1997
Electrical
Issued 24 August 1997
Resolved
ON ENGINE ROOM AUTOMATION DISPLAY BOARD REPLACE BURNED OUT "ACKNOWLEDGE" AND "SCAN" LAMPS
Condition: Unknown
Due 26 August 1997
Resolved 25 August 1997
Electrical
Issued 24 August 1997
Resolved
PROVE PROPER OPERATION OF ALL ALARMS AND SHUT DOWNS FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 26 August 1997
Resolved 25 August 1997
Lifesaving
Issued 24 August 1997
Resolved
MAKE OPERATIONAL PORT EYEWASH STATION.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Deck/Cargo
Issued 24 August 1997
Resolved
CALIBRATE IGS OXYGEN METER WITH SPAN GAS AND CALIBRATE THE RECORDER.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Unknown
Issued 24 August 1997
Resolved
RE-CONNECT AIR BOOSTER REMOTE REACH ROD.
Condition: Unknown
Due 24 August 1997
Resolved 25 August 1997
Lifesaving
Issued 24 August 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 August 1997
Resolved 25 August 1997
Construction/Loadline
Issued 10 October 1995
Resolved
Make adjustments to the watertight door starboard side on the 27'6" level.
Condition: Unknown
Due 21 October 1995
Resolved 27 October 1995
Electrical
Issued 10 October 1995
Resolved
Provide documentation of calibration for the under voltage and under frequency relays.
Condition: Unknown
Due 21 October 1995
Resolved 27 October 1995
Fire Fighting
Issued 10 October 1995
Resolved
Renew the hose on the CO2 semiportable fire extinguisher hosereel.
Condition: Unknown
Due 21 October 1995
Resolved 27 October 1995
Deck/Cargo
Issued 10 October 1995
Resolved
Make permanent repairs to the inert gas seawater cooling cross-over elbow on barge forward IGS deck.
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Electrical
Issued 10 October 1995
Resolved
Repair the following emergency lights: a. starboard passageway outside ofthe crew's mess, b. passageway outside the chief mate's stateroom, c. port hull next to the watertight door in steering compartment.
Condition: Unknown
Due 21 October 1995
Resolved 27 October 1995
Construction/Loadline
Issued 18 August 1994
Resolved
MAKE REPAIR PROPOSALS (BOTH TEMP AND PERM)TO [name withheld] IN #1 STBD DOUBLE BOTTOM.
Condition: Unknown
Due 19 August 1994
Resolved 2 September 1994
Construction/Loadline
Issued 18 August 1994
Resolved
PROVIDE [name withheld] SURVEY REPORT AND UNDERWATER SURVEY REPORT.
Condition: Unknown
Due 25 August 1994
Resolved 2 September 1994
Construction/Loadline
Issued 18 August 1994
Resolved
VSL IS RESTRICTED TO PORT EVERGLADES UNTIL RELEASED BY [name withheld] BERTHS.
Condition: Unknown
Due 25 August 1994
Resolved 2 September 1994
Construction/Loadline
Issued 18 August 1994
Resolved
MAKE TEMPORARY REPAIRS IN WAY OF #1 STBD DOUBLE BOTTOM TO THE SATISFACTION OF ATTENDING CG INSPECTOR.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Construction/Loadline
Issued 18 August 1994
Resolved
MAKE PERMANENT REPAIRS TO #1 STBD DOUBLE BOTTOM AT NEXT DRYDOCK EXAM.
Condition: Unknown
Due 2 September 1994
Resolved 2 September 1994
Deck/Cargo
Issued 13 August 1994
Resolved
PROVIDE TEST DATA AND MARK CARGO HOSES.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Lifesaving
Issued 13 August 1994
Resolved
RENEW EXPIRED DRUGS IN SHIPS FIRST AID KIT.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTS LOCATED ADJACENT TO HOSPITAL SPACE/SLOW CHARGE.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Fire Fighting
Issued 13 August 1994
Resolved
PROVIDE AND INSTALL DATA PLATE FOR FIRE DAMPER #3 LOCATED IN FAN ROOM.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
MAKE PERMANET REPAIR TO THE THROUGH DECK ELECTRICAL CONDUIT LOCATED FWD. BARGE MAIN DECK BELOW BELL.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Accommodation/Occupational Safety
Issued 13 August 1994
Resolved
MAKE NECESSARY REPAIRS TO STOP LEAKING HYDRAULIC FLUID ON THE PORT FWD DECKWINCH.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Accommodation/Occupational Safety
Issued 13 August 1994
Resolved
MAKE PERMANENT REPAIRS TO THE TILE FLOOR IN THE HOSPITAL SPACE HEAD.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
PROVIDE EMERGENCY LIGHT SUPPORT TRAY FOR THE LIGHT LOCATED IN THE TUG TUNNEL.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
PROVIDE ELECTRICAL CABLE SUPPORT BRACKETS FOR THE PORT FWD DAVIT IN WAY OF THE CABLE DRUM.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
PROVIDE ELECTRICAL CABLE SUPPORT BRACKETS FOR THE STBD FWD DAVIT IN WAY OF THE CABLE DRUM.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
PROPERLY HARD WIRE FROM A CIRCUIT PANEL/BREAKER THE PORT CONSOLE RECEPTACLEIN WAY OF ECC.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Deck/Cargo
Issued 13 August 1994
Resolved
MAKE PROPER REPAIRS TO AND PROVE PROPER OPERATION OF THE #3 CARGO PUMP PRIME MOVER LOW LUBE OIL ALARM AND SHUTDOWN.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Deck/Cargo
Issued 13 August 1994
Resolved
PROVIDE PROPER REPAIRS AS ORIGINAL, TO THE TEMPORARY PATCHED ELBOWS ON THE #1 CARGO PUMP PRIME MOVER SW SUPPLY PIPING.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
PROVIDE PROPER REPAIRS TO SECURE THE WIRING AND STARTING SOLENOID ON THE STBD SSDG.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
PROVIDE BLANK WHERE MISSING ON THE LIGHTING PANEL STBD SIDE AT 19' LEVEL.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 13 August 1994
Resolved
PROVE PROPER OPERATION OF THE PORT MDE OVERSPEED PROTECTION DEVICE.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 13 August 1994
Resolved
PROVE POPER OPERATION OF THE STBD MDE OVERSPEED PROTECTION DEVICE.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
REMOUNT CAT 3408 ALARM PANEL.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Fire Fighting
Issued 13 August 1994
Resolved
PROVIDE FIRE/SMOKE DETECTOR WHERE MISSING AT STBD MDE ERCP.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 13 August 1994
Resolved
PERFORM TEST OF IFO/DIESEL TRANSFER UNDERWAY PER ITEM 2.33 OF AUTOMATION TEST PROCEDURE AND LOG SAME IN OFFICIAL LOGBOOK.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Lifesaving
Issued 13 August 1994
Resolved
RENEW EMERGENCY DRINKING WATER IN BOTH LIFEBOATS.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Fire Fighting
Issued 13 August 1994
Resolved
PERFORM AND LOG EMERGENCY LIGHTING AND POWER BATTERY LOAD TEST AS REQUIEREDBY 46 CFR 35.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Lifesaving
Issued 13 August 1994
Resolved
PROVIDE PROPER REPAIRS TO THE GENERAL ALARM BELLS, LOWER LEVEL BARGE MACHINERY SPACE, SO THAT THEY ARE CLEARLY AUDIBLE THROUGHOUT.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
REPLACE PLASTIC WIRE TIES WITH METAL WIRE TIES ON ALL OVERHEAD HORIZONTAL_x001C_ RUNS THROUGHOUT ENGINE ROOM.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 13 August 1994
Resolved
PROVE PROPER OPERATION UNDER PRESSURE OF THE DC WATER REGULATING SAFETY.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 13 August 1994
Resolved
MAKE PROPER REPAIRS TO AND PROVE PROPER OPERATION OF THE ACKNOWLEDGE BUTTONON THE PORT 27' LEVEL AUTOMATION MONITOR (PORT MDE).
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Electrical
Issued 13 August 1994
Resolved
REMOUNT THE STBD MDE HIGH SW ALARM SWITCH BOX.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 13 August 1994
Resolved
PROVIDE ACCURATE NOTE IN AUTOMATION TEST PROCEDURE WITH REGARD TO ACTUAL MONITOR DISPLAYS FOR DEADMANS, UNANSWERED ALARM, AND ENGINEER NEEDS ASSISTANCE. INCLUDE 5 MINUTE RESET INFORMATION.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Lifesaving
Issued 13 August 1994
Resolved
RENEW LIFE BOAT CANNED MILK OR REPLACE WITH EMERGENCY PROVISIONS.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Accommodation/Occupational Safety
Issued 13 August 1994
Resolved
REPAIR VENT COVER TO ROPE LOCKER VENT STBD SIDE.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Construction/Loadline
Issued 13 August 1994
Resolved
REPLACE MISSING DOG & REFIT GASKET ON #1 STBD DOUBLE BOTTOM TRUNK.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Construction/Loadline
Issued 13 August 1994
Resolved
#4 PORT D.B. TRUNK- REPLACE MISSING DOG.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Construction/Loadline
Issued 13 August 1994
Resolved
#2 PORT D.B. TRUNK- REPLACE MISSING DOG.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Construction/Loadline
Issued 13 August 1994
Resolved
#1 PORT D.B. TRUNK- REPLACE BROKEN DOG.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Fire Fighting
Issued 13 August 1994
Resolved
REPLACE BROKEN VALVE HANDWHEEL ON FIRE STATION 19A LOWER.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 13 August 1994
Resolved
PROVIDE PROPER REPAIRS TO LOOSE BRICKWORK AROUND THE FIREBOX THROAT ON THE AUXILIARY BOILER.
Condition: Unknown
Due 13 August 1994
Resolved 13 August 1994
Accommodation/Occupational Safety
Issued 13 August 1994
Resolved
ON TUG'S PORTSIDE BOW, REPLACE MISSING HING PIN ON GOOSE NECK VENT COVER.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Accommodation/Occupational Safety
Issued 13 August 1994
Resolved
ON TUG'S STBD SIDE STERN, REPLACE MISSING GOOSE NECK VENT COVER & CLOSURE DEVICES.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Fire Fighting
Issued 13 August 1994
Resolved
PROVIDE TEST DATA SHEET FOR FIREFIGHTING FOAM.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Engineering
Issued 11 September 1993
Resolved
RENEW/REPLACE THE FLAME SCREEN ON THE EMERGENCY GENERATOR FUEL OIL DAY TANK.
Condition: Unknown
Due 11 September 1993
Resolved 11 September 1993
Construction/Loadline
Issued 11 September 1993
Resolved
MAKE PROPER REPAIRS TO THE PORT/STARBOARD WATERTIGHT DOORS LEADING AFT ON THE 40' LEVEL (BOLTS COCK-EYED, DOGS TOO TIGHT, POOR FIT).
Condition: Unknown
Due 11 September 1993
Resolved 11 September 1993
Construction/Loadline
Issued 11 September 1993
Resolved
MAKE PROPER REPAIRS TO THE WTD STARBOARD SIDE CROSSOVER IN THE ENGINEROOM.
Condition: Unknown
Due 11 September 1993
Resolved 11 September 1993
Fire Fighting
Issued 21 August 1993
Resolved
PROVIDE FOAM ANALYSIS TO [name withheld] PRIOR TO CARRIAGE OF MTBE CARGO.
Condition: Unknown
Due 5 October 1993
Resolved 5 October 1993
Engineering
Issued 9 July 1993
Resolved
PROVIDE PROOF THAT ALL PRESSURE VESSELS WERE EITHER HYDROSTATICALLY TESTED OR INTERNALLY EXAMINED IN AUGUST OF 1992 OR AFTER; OR CONDUCT SAID EXAMS PRIOR TO 15SEP93 TO SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Engineering
Issued 4 September 1992
Resolved
PROVE PRO0PER OPERATION OF FWD AND AFT BARGE BOILER SAFETIES FWD IMPROPER BLOWDOWN, AFT INPROPER LIFT SETTING) BARGE BOILER MAY ONLY BE USED IF (1) LICENSED ENGINEEER MAINTAINS CONTINOUS WATCH AT BOILER FLAT IN BARGE (2) BAOILER IS FIRED IN "CYCLE" MODE ONLY AT NO TIME MAY BOILER BE OPERATED IN
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Lifesaving
Issued 4 September 1992
Resolved
PROVIDE A COPY OF THE SERVICE REPORT CONCERNING INERMITENT OPERATION OF THEPORT LIFEBOAT WINCH BRAKE MECHANISM.
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Engineering
Issued 4 September 1992
Resolved
PROVE PROPER OPERATION OF OR REPAIR/REPLACE ALL LEAKING/WEEPING BOILER MOUNTS. MOUNTS PORPER OPERATION TO TESTED BY HOLDING WORKING PRESSURE HYDRO FOR 5-10 MIN. WITHOUT USE OF FEED OR EXTERNAL WATER PUMPS.
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Accommodation/Occupational Safety
Issued 24 August 1992
Resolved
MAKE PERMANENT REPAIRS TO MSD IWO VENT PIPING WHERE UNIT IS HOLED ON IT'S TOP. IAW 33CFR159
Condition: Unknown
Due 24 September 1992
Resolved 19 November 1992
Engineering
Issued 24 August 1992
Resolved
PROVIDE PROPER RELIEF VALVES FOR THE PORT AND STBD START AIR COMPRESSORS DISCHARGE PIPING (COMPRESSOR MAX 1000 PSI, BUT RELIEF VALVE SET 1300PSI). IAW 46CFR 54.15-10_x001C_
Condition: Unknown
Due 24 September 1992
Resolved 19 November 1992
Construction/Loadline
Issued 24 August 1992
Resolved
PROVE PROPER OPERATION OF WATERTIGHT DOORS LOCATED IN THE AFT TUG CROSSOVERSPACE (CHALK TEST) IAW VESSEL'S TRIM AND STABILITY BOOK AND 46 CFR 172.065
Condition: Unknown
Due 24 September 1992
Resolved 19 November 1992
Fire Fighting
Issued 24 August 1992
Resolved
SHOW PROPER OPERATION OF THE WATERSPRAY SYSTEM FOR THE STBD LIFEBOAT, DEMONSTRATING THAT THE CABIN-TOP SPRAY HEADS OPERATE AS INTENDED. SEE SOLAS CHAPTER 111, PART C, SECTION IV, REG. 46.
Condition: Unknown
Due 7 September 1992
Resolved 19 November 1992
Deck/Cargo
Issued 24 August 1992
Resolved
PROVIDE TOLUENE-CAPABLE COLORIMETRIC TUBES FOR THE TOXIC DETECTOR PRIOR TO THE CARRIAGE OF TOLUENE CARGO, AS PER 46CFR153._x001C_
Condition: Unknown
Due 24 September 1992
Resolved 19 November 1992
Deck/Cargo
Issued 24 August 1992
Resolved
DEMONSTRATE THE PROPER OPERATION OF CARGO TANK HIGH LEVEL ALARMS REQUIRED BY 46 CFR 153.409. PRIOR TO THE CARRIAGE OF TOLUENE OR XYLENE CARGOES, BUT IN NO CASE LATER THAN 24SEP92._x001C_
Condition: Unknown
Due 24 September 1992
Resolved 19 November 1992
Accommodation/Occupational Safety
Issued 24 August 1992
Resolved
DEMONSTATE PROPER WATERTIGHT CLOSURE OF THE PORT PONTOON DOOR FOR ESCAPE FROM ENGINEERING SPACES, AS PER 46 CFR 172.065
Condition: Unknown
Due 24 September 1992
Resolved 19 November 1992
Engineering
Issued 24 August 1992
Resolved
PROVE PROPER OPERATION OF THE AHEAD AND ASTERN INDICATORS AT THE PORT ER LOCAL CONTROL STATION IAW VESSELS ACCU TEST AND 46CFR62.35-5(B)(3)
Condition: Unknown
Due 24 September 1992
Resolved 9 December 1992
Deck/Cargo
Issued 24 August 1992
Resolved
PROVE PROPER OPERATION OF BLOWER LOW L/O SHUTDOWNS. IAW INTROL TEST PROCEDURES AND 46CFR 32.53-75.
Condition: Unknown
Due 24 September 1992
Resolved 19 November 1992
Lifesaving
Issued 24 August 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 September 1992
Resolved 19 November 1992
Lifesaving
Issued 24 August 1992
Resolved
PROVE PROPER OPERATION OF THE "ENGINEER NEEDS ASSISTANCE" ALARM IN THE 1AE'S STATEROOM. IAW THE VESSELS ACCU TEST AND 46CFR113.27
Condition: Unknown
Due 24 September 1992
Resolved 19 November 1992
Engineering
Issued 24 August 1992
Resolved
PROVE ECC THROTTLE CONTROL HAS NO SINGLE FAILURE POINTS, IAW 46 CFR 62.30- 5(A)
Condition: Unknown
Due 24 September 1992
Resolved 9 December 1992
Engineering
Issued 24 August 1992
Resolved
SET AND SEAL BARGE AUXILLARY BOILER SAFETY VALVES IAW 46CFR31.10-15(B).
Condition: Unknown
Due 7 September 1992
Resolved 9 December 1992
Documentation
Issued 24 August 1992
Resolved
MAKE AVAILABLE FOR FIRESIDE, WATERSIDE AND WORKING PRESSURE HYDRO (MAWP) EXAMS TEST FOR THE TUG AND BARGE AUXILLARY BOILERS IAW 46CFR31.10-5(B)
Condition: Unknown
Due 7 September 1992
Resolved 19 November 1992
Accommodation/Occupational Safety
Issued 24 August 1992
Resolved
DEMONSTRATE PROPER OPERATION OF THE WATERIGHT DOOR OPEN/CLOSE INDICATOR PANEL FOR THE AFT PONTOON ESCAPE DOOR, STBD SIDE, FROM ENGINEERING SPACE. 46 CFR 172.065
Condition: Unknown
Due 24 September 1992
Resolved 19 November 1992
Navigation
Issued 24 August 1992
Resolved
PROVE ECC THROTTLE CONTROL HAS NO SINGLE FAILURE POINTS IAW 46CFR62.30-5(A)
Condition: Unknown
Due 24 September 1992
Resolved 9 December 1992
Engineering
Issued 24 August 1992
Resolved
PROVIDE GENERAL ALARM CONTACT MAKER IN ECC, IAW 46 CFR 113.25-5
Condition: Unknown
Due 24 September 1992
Resolved 9 December 1992
Engineering
Issued 24 August 1992
Resolved
PROVIDE RELIEF VALVES FOR STARTING AIR RECEIVERS THAT COMPLY WITH 46CFR54.15-10.
Condition: Unknown
Due 24 September 1992
Resolved 9 December 1992
Lifesaving
Issued 24 August 1992
Resolved
PERFORM A WEIGHT TEST OF BOTH LIFEBOATS AS REQUIRED BY 46 CFR 91.025- 15(A)(2)._x001C_
Condition: Unknown
Due 7 September 1992
Resolved 19 November 1992
Fire Fighting
Issued 24 August 1992
Resolved
NEED TO REVISE ALL FIRE SAFETY PLANS TO REFLECT THE UP TO DATE LOCATION OF REQUIRED SAFETY EQUIPMENT AS PER SOLAS CH 11-2 PART A REG. 20.
Condition: Unknown
Due 7 September 1992
Resolved 19 November 1992
Electrical
Issued 28 October 1991
Resolved
CLEAR GROUND IN 12OV BUS CIRCUIT IN BARGE SWBD.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Electrical
Issued 28 October 1991
Resolved
PROVE PROPER OPERATION OF 12OV BUS GROUND DETECTION SYSYTEM FOR FWD EMERGENCY LIGHTS PANEL IN BARGES SWITCH BOARD.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Electrical
Issued 28 October 1991
Resolved
INSTALL A BLANK FOR MISSING CIRCUIT BREAKER ON BARGE SWITCHBOARD.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Construction/Loadline
Issued 26 September 1991
Resolved
PROVIDE LTR FROM MASTER AND [name withheld] TO VSL'S SEAWORTHINESSFOR UNDERWATER EXAM IN LIEU OF DRY DOCK.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Electrical
Issued 26 September 1991
Resolved
PROVE PROPER OPERATION OF BARGE GENERATOR'S ALARMS AND TRIPS.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Deck/Cargo
Issued 26 September 1991
Resolved
PROVIDE CG APPROVED DATA FOR BOND STRAND (FGP) PIPING ON CARGO DECK USED FOR AIR SERVICE. PIPING MAY NOT BE USED UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Navigation
Issued 26 September 1991
Resolved
PROVIDE A CURRENT DEVIATION TABLE FOR THE VSL'S MAGNETIC COMPASS.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Lifesaving
Issued 26 September 1991
Resolved
REPAIR STBD LIFEBOATS AFT COXSWAINS HATCH (LATCH/HINGE BROKEN).
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Engineering
Issued 26 September 1991
Resolved
PROVE PROPER OPERATION OF REMOTE FUEL OIL AND DIESEL OIL BOOSTER AND XFER PUMP SHUTDOWN IN ENGINE CONTROL ROOM (STANDBY PUMPS COME ON LINE WHEN TRIPSACTIVATED).
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Construction/Loadline
Issued 26 September 1991
Resolved
PROVE PROPER OPERATION OF PORT HULL OWS.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Lifesaving
Issued 26 September 1991
Resolved
PROVIDE 100% CAPACITY AND SOLAS A PACKS AND SERVICED HYDROSTATIC RELEASES FOR THE VESSELS INFLATABLE LIFERAFTS.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Construction/Loadline
Issued 26 September 1991
Resolved
PROVE PROPER OPERATION OF CARGO DECK LIGHTING.
Condition: Unknown
Due 3 October 1991
Resolved 4 December 1991
Deck/Cargo
Issued 26 September 1991
Resolved
PROVIDE CURRENTLY CALIBRATED GUAGES FOR CARGO MANIFOLD.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Deck/Cargo
Issued 26 September 1991
Resolved
REMOVE DIESEL POWERED AIR COMPRESSOR (SKID MOUNTED) FROM CARGO DESK LOCATION.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Deck/Cargo
Issued 26 September 1991
Resolved
REMOVE LASHED CARGO CONTAINERS AND EXTRANEOUS GEAR FROM CARGO DECK AREA.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Navigation
Issued 26 September 1991
Resolved
PROVE PROPER OPERATION OF BARGE RUNNING LIGHTS.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Accommodation/Occupational Safety
Issued 26 September 1991
Resolved
PROVE PROPER OPERATION OF ACCOMODATION VENT TRIPS FROM BRIDGE LOCATION.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Deck/Cargo
Issued 26 September 1991
Resolved
PROVE PROPER OPERATION OF CARGO PUMP REMOTE TRIPS FROM ALL DK LOCATIONS.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Deck/Cargo
Issued 26 September 1991
Resolved
PROVE PROPER OPERATION OF TUG'S ANCHORS.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Construction/Loadline
Issued 26 September 1991
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION THE TUG'S VOIDS AND COFFERDAMS.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Electrical
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE STBD SSDG IAW SUB F AND I
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE MAIN PROPULLISION SYSTEM'S WRONG DIRECTION ALARM IAW AUTO TEST PROC. 2.3.6
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE AUTOMATION FOR THE TUG'S BOILER IAW 46 CFR 63.05
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE POWER FAILER ALARM IAW AUTO PROC. TEST 5.4
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROPERLY LABEL THE P&S ENGINEROOM MAIN DECK REMOTE F/O SHUTDOWNS IAW 46 CFR 56.50-1(G)(2)
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Fire Fighting
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE FIRE MAIN GUAGE LOCATED ON THE ENGINEROOM CONSOLE
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
CONDUCT INTERNAL EXAM OF ALL 7 TUG + BARGE P.V.'S AND BARGE DC HTR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE STBD ENGINEROOM SSAR RELIF VALVE IAW 46 CFR 54.15-10(A)
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE GAUGES ON THE DISCHARGE SIDE OF ALL 4 ENGINE-ROOM AIR COMPRESSORS
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE PORT AND STBD LON MDE L/O ALARMS IAW AUTOMATION PROCEEDURES TEST 4.16
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE PORT AND STBD MDE HIGH JW TEMP ALARM IAW AUTO. PROC. TEST 4.11
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVIDE A LABEL FOR THE STBD ENGINEROOM SSAR (SHIP SERVICE AIR RECEEVERS) RELIF VALVE IAW 46 CFR 54.15-1(B)
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE TURBO L/O MDE SHUTDOWNS IAW AUTOMATION PROCEDURES TEST 3.14 AND 3.17
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE LON PRESS. FUEL PRESS. FUEL OIL. ALARM FOR THE STBD MDE IAW AUTOMATON PROCEDURE TEST 4.1
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE PORT AND STBD MDE HIGH L/O LEVEL ALARMS IAW AUTOMATION PROCEDURES TEST 4.15
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE BARGE SSAR RELICT VALVE IAW 46 CFR 54.15- 1(B).
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE P&S MDE HIGH ENGINE L/O TEMP ALARM IAW AUTO. PROC. TEST 4.12
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE P&S MDE RIGHT & LEFT BANK HIGH TURBO TEMP ALARMS IAW AUTO PROC. TEST 4.13
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE P&S MDE REDUCTION GEAR L/O HIGH TEMP ALARMS IAW AUTO PROC. TEST 4.14
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE AUTO SWITD OVER OF THE INT. FUEL BOOSTER PUMPIAW AUTO PROC. TEST 4.4 & 4.5
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVIDE A NAME PLAT FOR THE DC HTR (BARG) THAT IS READABLE AND CONTAINS THE INFO IN 46 CFR 54.10-20 IAW 46 CFR 54.10-20(1)
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Deck/Cargo
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE VISUAL ALAMS FOR THE IGS SYSTEM IAW 46 CFR 32.53-70
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVIDE HAND LIFTING GEAR FOR THE DC HEATER (BARGE) RELIF VALVE IAW 46 CFR 54.15-10.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990
Resolved
PROVE PROPER OPERATION OF THE PORT AND STARBOARD MDE OVERSPEEDS IAW AUTOMATION PROCEDURES TEST 3.21
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 29 June 1990
Resolved
CLEAR GROUND ON 120 BUS "B" PHASE IN BARGE'S PUMPROOM SWITCHBOARD FOR MACHINERY SPACE EMERGENCY LIGHTS DISTRIBUTION PANEL.
Condition: Unknown
Due 29 June 1990
Resolved 29 June 1990
Electrical
Issued 29 June 1990
Resolved
CLEAR GROUND ON 450 BUS "B" PHASE IN BARGE PUMP ROOM SWITCHBOARD.
Condition: Unknown
Due 29 June 1990
Resolved 29 June 1990
Navigation
Issued 2 May 1990
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT HAVING CHARTS 12326 AND 12327 ON BOARD AS REQUIRED BY 33 CFR 164.33 (A)(1)
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 1 May 1987
Resolved
CONDUCT OVERSPEED TRIP TEST TO #1 & 2 MAIN PROPULSION DIESEL ENGINES.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987
Construction/Loadline
Issued 15 September 1986
Resolved
REPAIR OR REPLACE AND PROVE PROPER OPERATION OF REMOTELY OPERATED BILGE SUCTION VALVES IN TUG FORE PEAK.
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Navigation
Issued 15 September 1986
Resolved
SUBMIT PLANS FOR APPROVAL TO USCG MARINE SAFETY OFFICE FOR THE INSTALLATIONOF THE HYDRAULIC MAKE-UP TANKS AND LOW LEVEL ALARM SYSTEM FOR PORT AND STBDSTEERING SYSTEMS NOT LATER THAN 15OCT86. INSTALLATION TO BE COMPLETED PRIORTO 15 DEC 1986.
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Navigation
Issued 15 September 1986
Resolved
INSTALL A NON SKID SURFACE IN VICINITY OF EACH STEERING GEAR SYSTEM.
Condition: Unknown
Due 15 September 1986
Resolved 15 September 1986
Construction/Loadline
Issued 3 April 1986
Resolved
CROP AND RENEW SET IN BOTTOM PLATES IN WAY OF #5 STBD DOUBLE BOTTOM INBOARDSECTION AND #4 PORT DOUBLE BOTTOM TURN OF THE BILGE AREA. THESE REPAIRS TO BE MADE AND TESTED TO THE SATISFACTION OF THE COGNIZANT OCMI AND TO BE COMPLETED AT NEXT SCHEDULED DRYDOCK IN AUGUST 1986.
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986
Deck/Cargo
Issued 17 August 1984
Resolved
REPLACE NON-METALLIC FLEXIBLE HOSE IN HYDRAULIC PUMP FLUSHING AND CASE DRAIN SYSTEM WITH SUITABLE HARD PIPING AND SHORT FLEXIBLE CONNECTIONS
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984
Electrical
Issued 17 August 1984
Resolved
PROVIDE VERIFICATION THAT MODIFIED ELECTRICAL GENERATORS MEET 46 CFR 111.12-5. SSG'S RESTRICTED TO 600 KW UNTIL VERIFICATION RECEIVED.
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984
Lifesaving
Issued 17 August 1984
Resolved
PROVIDE 30 CG APPROVED EXPOSURE SUITS.
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984
Deck/Cargo
Issued 17 August 1984
Resolved
PROVIDE APPROVED OILY WATER SEPARATOR.
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984