MAURY USCG vessel records Sign in
← All vessels

VENUSGAS

VENUSGAS is a 1982 tank ship. The Coast Guard has recorded 61 inspections since 1986, most recently in September 2023, along with 25 deficiencies and 9 operational controls, 3 with no removal date recorded.

Records from 1986 to 2023. Most recent: inspection, 13 September 2023.

Built
1982
Last inspected
13 September 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
3 with no removal date recorded

Identity

8111855 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-54112

Inspections, by type

…with no type recorded38
Years with a record 15 calendar years (1986–2023)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6975 - Dead Weight, Ton
10881 - Displacement, Ton
5643 - Convention (Subpart B), Gross Ton
5643 - Regulatory (Subpart C or D), Gross Ton
1692 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 61

13 September 2023 Deficiency Check
Physical examination · Liquefied Gas Carrier National Center of Expertise · Activity 7790931
10 July 2008 PI Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3263784
10 July 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3264638
20 January 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3133491
16 January 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3131148
18 December 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3117541
26 October 2007 PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3087143
20 March 2007 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2891527
13 March 2007 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2886870
12 February 2007 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2870825
12 February 2007 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2875196
9 February 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2869950
16 July 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2135689
21 April 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2049009
14 April 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2043882
6 April 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2038185
6 April 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2038580
1 April 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2039775
23 March 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2029386
19 March 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2027592
3 March 2004 Administrative Inspection · Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2017106
15 February 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2009765
23 January 2004 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1993260
2 January 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 398782
2 January 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1097868
12 June 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 392231
5 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389831
15 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407522
14 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 99487
13 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373738
13 December 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 856945
1 November 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 372433
1 November 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 865227
30 October 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 19557
25 May 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328107
17 April 1994 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 496161
17 April 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389815
11 September 1993 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 106102
13 June 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 358901
9 January 1993 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141646
23 September 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 353428
27 August 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 486204
11 August 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1264461
9 April 1992 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 350024
9 April 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1258552
24 March 1992 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 349677
19 February 1992 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 348960
19 February 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1255916
12 September 1991 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 466084
1 January 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 341100
1 January 1991 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1244597
31 December 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1211419
11 December 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 327290
11 December 1988 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1346220
22 March 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 469708
21 March 1988 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 989505
19 June 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 484528
3 October 1986 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1315603
1 October 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 534708
1 October 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1007957
6 June 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 309323

Deficiency record · 25

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 July 2008 Resolved
Class A fire doors in main stairway not self-closing; fire door on B-deck has bent closing mechanism. SOLAS 74 II-2/23f (action taken 17A)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2008
Resolution: Actuation cylinders adjusted & found to close & latch.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 10 July 2008 Resolved
Fixed gas detection system is not properly operating. Does not properly annunciate in space where leak originates. Consistent flow failure alarm while sampling once activated. Unable to determine proper master/slave assembly of both units. Gas calibration curves not in working language of crew. IGC 13.6 / GC 13.6 (action taken 30A)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2008
Resolution: New Flameproof gas detection sensor & annunciator were fitted aboard the vessel. Sensor found to be working satisfactorily. Alarms annunciate in appropriate locations.
Operations/Management › Pollution › Reporting Discharge of Hazardous Substance
Issued 10 July 2008 Resolved
Operator did not follow required response procedures. Notifications were not made by operator to DPA or Qualified Individual to initiate hazardous material response after release/purge of cargo vapor through vent mast riser in U.S. waters. Approximate discharge quantity was 10 lbs; reportable quantity is 1 Ib. To the satisfaction of Class/RO/RSO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2008
Resolution: Deficiency was attributed to SOLAS XI-1/4 instead of IGC Code. Clear grounds were established that Master & Crew were unfamiliar w/essential shipboard procedures (response to cargo leak/release).
Deck/Cargo › Cargo Stowage › General
Issued 10 July 2008 Resolved
Cargo Compressor room has cargo leak of indeterminate origin. Amount of VCM in space remained approximately at 35 ppm with natural & extra mechanical ventilation activated. Vessel to determine cause & effect permanent repairs. To the satisfaction of Class/RO/RSO.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 August 2010
Resolution: Open deficiencies on this decommissioned and scrapped vessel were administratively closed based on the objective evidence provided in Bureau Veritas’ email dated August 16, 2023. The email has been uploaded into the vessel’s documents.
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 10 July 2008 Resolved
Ship's crew did not don necessary protective equipment to minimize exposure to onloading cargo. TLV for cargo is 1 ppm; STEL is 5 ppm. Crew was tested to have residual amounts up to 50 ppm. Furthermore, ship allowed non-crew personnel access near hazardous spaces without needed PPE. To the satisfaction of Class/RO/RSO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2008
Resolution: Deficiency to be written against SOLAS XI-1/4 for crew not understanding how to follow essential shipboard procedures regarding safety of ships, instead of IGC 18.6
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 14 April 2004 Resolved
Vessel issued Letter of Deviation to deviate from the requirements of 33 CFR 164.40(a) maintaining a properly op speed log. This was based on the understanding that the equipment will be op prior to entry to next US port after the vsls next dry dock w/ written not. of repairs submitted to that COTP
Action required: 15 - Rectify deficiencies by next port
Resolved 12 February 2007
Resolution: Successfully tested during COC exam (Activity# 2870825)
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 19 March 2004 Resolved
Vessel issued Letter of Deviation to enter/depart the port of Corpus Christi with an inoperable speed log (33 CFR 164.40(a)). This was based on the understanding that the equipment will be operational prior to entry into next US port after the vessels next dry dock. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 February 2007
Resolution: Tested successfully during COC exam (Activity# 2870825)
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 3 March 2004 Resolved
Rudder angle indicator off 4-5 degrees to the starboard side during tests of the steering gear LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 12 February 2007
Resolution: Completed successful steering gear test durring COC exam (Activity# 2870825)
Engineering › Diesel Engine (propulsion-electric)
Issued 3 March 2004 Resolved
#6 Fuel pump on #2 SSG leaking diesel fuel LEGACY COMPONENT DESC: Injector (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2004
Resolution: Replaced Fuel Pump
Documentation › Safety Management System
Issued 23 January 2004 Resolved
Vessel has operated without gas detection system for the past 7 months without repair or replacement. DOC audit required. LEGACY COMPONENT DESC: Company Responsibility/Authority Documentation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2004
Resolution: Audit carried out by GL. Scope included the verification whether the Company followed implemented QA/SMS procedures on handling/rectifying the malfunction/replacement of fixed gas detection system onboard MT "Zetagas." 1 non-conformity closed.
Fire Fighting › Ventilation Systems
Issued 23 January 2004 Resolved
Ventialtion Dampers in Motor Room and Compressor rooms frozen. Repair to the satisfaction of Cert. of Fitness Auth.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2004
Resolution: Ventilation dampers were tested and found to be in satisfactory working order.
Fire Fighting
Issued 23 January 2004 Resolved
Fixed gas detection system not onboard. Install prior to conducting cargo operations. LEGACY COMPONENT DESC: Fixed gas Detection System
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2004
Resolution: Alarm monitor was defective, the remaining components were tested and found to be operational. Procedures for a watchstander to monitor the system were established and were verified and approved by GL surveyor as well as USCG inspectors.
Electrical › Electrical Distribution System (service)
Issued 23 January 2004 Resolved
Electrical wires to cargo tank sensors have temporary repairs. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 15 February 2004
Resolution: Reviewed class report attesting to the satisfactory replacement of the level sensor cables to tanks #2 and #3.
Navigation
Issued 2 January 1997 Resolved
Rudder angle indicator is not functioning properly.
Condition: Unknown
Due 2 January 1997
Resolved 3 January 1997
Unknown
Issued 13 December 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 December 1994
Resolved 28 December 1994
Navigation
Issued 13 December 1994 Resolved
VESSEL'S GYRO COMPASS BEING SERVICED AT THE TIME OF INSPECTION. PROVIDE SERVICEING REPORT TO COTP NEW ORLEANS. 33 CFR 164.35(D).
Condition: Unknown
Due 15 December 1994
Resolved 10 January 1995
Navigation
Issued 17 April 1994 Resolved
INSTALL A NON-SLIP SURFACE AROUND MAIN STEERING GEAR UNIT TO ENSURE SUITABLE WORKING CONDITIONS. REF: SOLAS CHAP.II-1; PART C; REG.29,13.2
Condition: Unknown
Due 17 April 1994
Resolved 17 April 1994
Deck/Cargo
Issued 17 April 1994 Resolved
PRIOR TO NEXT U.S. PORT, MAKE REPAIRS TO IGS AND PROVE PROPER OPERATION TO THE SATISFACTION OF VESSEL'S CLASS SOCIETY AND LOCAL [name withheld].
Condition: Unknown
Due 17 April 1994
Resolved 17 April 1994
Construction/Loadline
Issued 17 April 1994 Resolved
PRIOR TO NEXT U.S. PORT MAKE PERMANENT REPAIRS TO BALLAST PUMP RAW WATER SUCTION PIPE. PIPE HAS BEEN TEMPORARY REPAIRED.
Condition: Unknown
Due 17 April 1994
Resolved 17 April 1994
Documentation
Issued 24 March 1992 Resolved
SUBMIT THE CERTIFICATE OF FITNESS DATED 22MAR92 TO COMDT (G-MSC) FOR APPROVAL AND PLACE NEW SUBCHAPTER "O" ENDORSEMENT ONBOARD PRIOR TO THE NEXTU.S. VOYAGE.
Condition: Unknown
Due 30 March 1992
Resolved 10 April 1992
Deck/Cargo
Issued 24 March 1992 Resolved
REPAIR AND PROVE OPERATION OF THE INERT GAS OXYGEN ANALYZER PRIOR TO THE NEXT U.S. VOYAGE.
Condition: Unknown
Due 30 March 1992
Resolved 10 April 1992
Deck/Cargo
Issued 19 February 1992 Resolved
EFFECT REPAIRS AS NECESSARY AND PROVE OPERATION OF THE I.G.S. HIGH O2 ALARMAT NEXT U.S. PORTCALL.
Condition: Unknown
Due 19 February 1992
Resolved 19 February 1992
Electrical
Issued 19 February 1992 Resolved
REPAIR/REMOVE GASKETS AND PAINT FROM FLAME PATH SURFACES AND RENEW AS NECESSARY CABLE SEAL GLANDS ALL CARGO PUMP EXPLOSION PROOF FIXTURES AND EXPLOSION PROOF LIGHTS IN HAZARDOUS LOCATIONS PRIOR TO NEXT U.S. PORTCALL.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Navigation
Issued 31 December 1989 Resolved
PROVIDE SERVICE REPORT OF GYRO REPAIR TO USCG [name withheld].
Condition: Unknown
Due 31 December 1989
Resolved 31 December 1989
Fire Fighting
Issued 1 October 1986 Resolved
DEMONSTRATE OPERATION OF THE DECK WATER SPRAY TO A COAST GUARD MARINE INSPECTOR PRIOR TO CARGO OPERATIONS.
Condition: Unknown
Due 1 October 1986
Resolved 1 October 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.