Records from 1982 to 1990. Most recent: inspection, 5 December 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 5 December 1989
Resolved
REPAIR OR REPLACE EMERGENCY LIGHT IN ENGINE ROOM ABOVE ALARM PANEL.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Electrical
Issued 5 December 1989
Resolved
REPAIR OVERHEAD AND ABOVE SINK LIGHTS IN CREW HEAD, LIGHT ABOVE SINK NEEDS COVER.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Unknown
Issued 5 December 1989
Resolved
SECURELY FASTEN ACYETYLINE BATTLE ON FWD, PORT SIDE OF MAIN DECK.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Electrical
Issued 5 December 1989
Resolved
PROPERLY SPLICE WIRES TO SIREN IN ENGIN ROOM ABOVE ALARM PANEL.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Electrical
Issued 5 December 1989
Resolved
REPAIR OR REPLACE ROTATING YELLOW LIGHT IN AFT, STBD ENGINE ROOM. LIGHT IS INOPERATIVE.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Electrical
Issued 5 December 1989
Resolved
REPAIR LIGHT TO STBD SIDE AFT OF STEERING AREA. NEEDS NEW BULB, GLOBE AND GUARD.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Documentation
Issued 11 February 1989
Resolved
COMPLETED BY 28FEB89. ITEMS #18,19.22.24.25.27 AND 29.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Navigation
Issued 11 February 1989
Resolved
REPLACE THE BURUNED OUT BULBS LOCATED IN THE STEERING GEAR VISUAL PANEL FORTHE POWER/RUN INDICATOR LIGHTS 46CFR111.93-1.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Accommodation/Occupational Safety
Issued 11 February 1989
Resolved
REMOVE AND PROPERLY STORE THE PAINT FROM THE STARBOARD DECK LOCKER.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Fire Fighting
Issued 11 February 1989
Resolved
FOR THE SURVIVAIR SELF CONTAINED BREATHING APPARATUS, OBTAIN A CURRENT HYDROSTATIC TEST, SINCE ONE MUST BE DONE EVERY 5 EYARS.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Fire Fighting
Issued 11 February 1989
Resolved
THE OWNER, MASTER, OR PERSON IN CHARGE SHALL SATISFY HIMSELF THAT ALL PORT/SEMI PORTABLE AND FIXED FIRE EXTINGUISHING SYTEMS ARE SERVICED AND RCORDS KEPT 46CFR97.15-60 AND 91.25-20. ALL RECORDS SHALL BE KEPT WITH THE SHIPS LOG.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Fire Fighting
Issued 11 February 1989
Resolved
WEIGH AND EXAMINE FOR CORROSION ALL FIXED CO2 BOTTLES ABOARD THE VESSEL, INCLUDING THE BOTTLE FOR THE HOSE REEL IN THE ENGINE ROOM, 46CFR91.25-20(A)(2).
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Fire Fighting
Issued 11 February 1989
Resolved
FOR ALL FIXED CO2 SYSTEMS CHECK TO ASCERTAIN THAT ALL PIPING CONTRL, VALVESAND ALARMS ARE IN OPERATING CONDITION 46CFR91.25-20(C)(3).
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Fire Fighting
Issued 11 February 1989
Resolved
ENSURE ALL PORTABLE FIRE EXTINGUISHERS ARE INSTALLED IN THE MANUFACTURERS RECOMMENDED BRACKET THAT ENSURES SECURE STORAGE. LINE OR STRING OR WIRE SHALL NOT BE USED.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Fire Fighting
Issued 11 February 1989
Resolved
ALL PORTABLE CO2 BOTTLES OF THE USCG-APPROVED TYPE MUST HAVE HYDRO STATIK TEST DATES, STAMPED ON THEIR NECK, WITH THE PAST 5 YEARS. (ONE BOTTLE WAS 4-76, 4 OTHERS 7-84)
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Fire Fighting
Issued 11 February 1989
Resolved
REMOVE/REPLACE OR HYDROSTATICALY TEST THE DRY CHEMICAL FIRE EXTINGUISHERS MANUFACTURED IN 1976, LOCATED ON OFFICER-LEVEL LOUNGE. DRY CHEMICAL STOREDPRESURE FIRE EXTINGUISHERS ARE REQUIRED TO BY HYDROSTATICALLY TESTED EVERY 12 YEARS.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
PROVIDE NEW OR PROPERLY SERVICED HYDROSTATIC RELEASES FOR THE TWO INFLATABLLIFE RAFTS. 46CFR160.062-4(F)(2)
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
PROVIDE AND PROPERLY AFFIX TO THE TWO LIFE RAFT PAINTERS AND TO THE SHIP, THE REQ. FLOAT FREE LINK DESCRIBED IN 46FR160.051-7(B)(8).
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
OBTAIN THE LAST LIFERAFT SERVICING CERTIFICATES FOR THE TWO LIFERAFTS ON BOARD. 46CFR160.051-6(E)(2).
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
PROVIDE THE MISSING SPRING CLIPS FOR 3 OF THE 27 LIFE PRESERVERS ABOARD, UNITL THIS DEFICIENCY IS CORRECTED, OR UNTIL 3 SATISFACTORY JACKETS ARE PLACED AOBARD, A MAXIMUM OF 24 PEOPLE SHALL BE CARRIES.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
PROVIDE THE MISSING HANDLE, WHICH RAISES THE RESCUE BOAT, TO THE RESCUE BOAT BOOM.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
AT THE WEEKLY FIRE AND BOAT DRILL ENSURE THAT ALL CREWMEMBERS ARE ALERTED TO THE SHORT COMMINGS OF THE LIFERAFT INSTALLATIONS, IN THE THAT IT WILL NOT FLOAT FREE FROM THE VESSEL AND MUST BE ATTENDED TO BY CREW MEMBERS FOR LAUNCH. (SEE MIDR REPORT FOR COMPLETE DETAILS.)
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Construction/Loadline
Issued 11 February 1989
Resolved
REPLACE THE GASKET MATERIAL, WHERE MISSING, TO THE STARBOARD COVER TO THE ENGINE ROOM VENTILATOR.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Electrical
Issued 11 February 1989
Resolved
MAKE THE INOPERABLE CREW JUNK LIGHTS OPERABLE. SOME DID NOT WORK.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Fire Fighting
Issued 11 February 1989
Resolved
PROVIDE ADDITIONAL FIRE HOSE FOR A TOTAL OF 6 ON BOARD. SUCH HOSE SHALL MEET THE REQUIREMENTS AS OUTLINED IN 46CFR95.10-10(L).
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Documentation
Issued 11 February 1989
Resolved
THE MASTER SHALL IMMEDIATELY CARRY ON ALL ACTIONS AND OBSERVATIONS LISTED IN 46CFR97, AND THEN AGAIN AS OFTEN AS REQ. THESE ACTIONS AND OBSERVATIONS SHALL THEN BE LOGGED. SEE THE DETAILED DESCRIPTION OF EACH ACTION AND OBSERVATION FOR WHAT MUST BE INCLUDED IN THE LOG BOOK ENTRY.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
REATTACH THE LOOSE BECKETS, AT EQUIDSTANT POINTS ABOUT THE BODY OF THE RINGBUOY, WITH SUITABLE WATER PROOF ADHESIVE, ON ALL AFFECTED RING BUOYS. 46CFR160.050-4(D).
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Electrical
Issued 11 February 1989
Resolved
CLEAN CORROSION FROM BATTERY TERMINALS IN BOXES LOCATED AFT OT THE PILOT HOUSE.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Electrical
Issued 11 February 1989
Resolved
PROVIDE A COVER FOR THE REFRIGERATOR COMPRESSOR LOCATED IN THE PORT DECK LOCKER 46CFR58.01-20.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Engineering
Issued 11 February 1989
Resolved
PROVIDE A CORROSION RESISTANT WIRE SCREEN OF AT LEAST 30+30 MESH FOR THE BOW THRUST FUEL TANK VENT AND THE NUMBER 4 PORT FUEL OIL TANK VENT TO REPLACE THE WASTED SCREEN AS REQUIRED BY 46CFR56.50-85(A).
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Electrical
Issued 11 February 1989
Resolved
REPAIR THE 220 VOLT OUTLET LOCATED IN THE STARBOARD DECK LOCKER.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Lifesaving
Issued 11 February 1989
Resolved
PROVIDE A TOTAL OF 3 WORKING WATER LIGHTS FOR THE RING LIFE BUOYS. ONLY ONEOF THE TWO ABOARD AS TESTED. TEST THE SECOND AND OBTAIN WATER LIGHTS AS NEEDED.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Construction/Loadline
Issued 11 February 1989
Resolved
TO REPAIR TO BALLAST PIPING IN THE ENGINE ROOM IN WAY OF THE FORWARD WATER TIGHT DOOR, () USE MATERIAL AS REQUIRED BY 46CFR56.10-1,(B) JOINTS SHALL BEMADE RAB IN ACCORDANCE WITH 46CFR56.30-1. IF WELDED JOINTS ARE USED, THE PRODECURE AND WELDER SHALL BE QUALIFIED IAW 46CFR57.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Engineering
Issued 11 February 1989
Resolved
REPAIR THE OILY WATER SEPARATOR REQUIED BY PARAGRAPH 2.2.2 OF TH FORM A SUPPLEMENT TO THE IOPP CERTIFICATE. ENSURE IT FUNCTIONS AS DESCRIBED IN ITS SERVICE MANUAL. 33CFR155.360(A).
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Engineering
Issued 11 February 1989
Resolved
PROVIDE THE OILY WATER SEPARATOR DISCHARGE WITH THE AUTOMATIC STOPPING DEVICE AS REQUIED BY PARAGRAPH 2.3.1.1 OF THE FORM A SUPPLEMENT TO THE IOPPCERTIFICATE.
Condition: Unknown
Due 6 June 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 11 February 1989
Resolved
RECONNECT THE OILY WATER SEPARATOR TO THE WASTE OIL TANK FOR THE STORAGE OFOILY RESIQUES. 33CFR155.360(B).
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Documentation
Issued 11 February 1989
Resolved
OBTAIN AND MAINTAIN AN OIL RECORD BOOK AS REQUIRED BY 33CFR151.25.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Unknown
Issued 11 February 1989
Resolved
REPAIR OR REMOVE THE SWITCH MARKED FOR ENGINE ROOM VENTILATION SHUT DOWN ON THE SUPERSTRUCTURE IN WAY OF THE PORT STORAGE LOCKER IT WAS NOT FUNCT. 46CFR58.01-25.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Electrical
Issued 11 February 1989
Resolved
RENEW/REPAIR THE CRACKED RADIO BATTERY BOX COVER BEHIND THE PILOT HOUSE.
Condition: Unknown
Due 11 February 1989
Resolved 11 February 1989
Deck/Cargo
Issued 10 December 1987
Resolved
PROVE PROPER OPERATION OF #4 BULK TANK RELIEF VALVE (WOULD NOT SEAT).
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Engineering
Issued 10 December 1987
Resolved
PROVE PROPER OPERATION OF REMOTE SHUT-OFF ON STBD AUXILIARY FUEL TANK.
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Engineering
Issued 10 December 1987
Resolved
PROVIDE DISCHARGE BILGE ALARM MONITOR FOR OILY WATER SEPARATOR.
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Engineering
Issued 10 December 1987
Resolved
CONDUCT PROPER OPERATION OF VESSEL'S OILY WATER SEPARATOR.
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Fire Fighting
Issued 10 December 1987
Resolved
SERVICE FIXED FIRE FIGHTING SYSTEMS FOR ENGINE ROOM AND BOW THRUSTER ROOM. (CO2 SYSTEM)
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Lifesaving
Issued 10 December 1987
Resolved
PROVIDE BATTERIES FOR LIGHTS ON LIFE PRESERVERS.
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Construction/Loadline
Issued 10 December 1987
Resolved
REWORK AND FREE UP REACH ROD IN FOREPEAK TANK.
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Electrical
Issued 10 December 1987
Resolved
PROVE PROPER OPERATION OF #1 & #2 SHIP SERVICE GENERATOR OVERSPEEDS.
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Accommodation/Occupational Safety
Issued 10 December 1987
Resolved
PROVE PROPER OPERATION OF REMOTE VENTILATION SHUTDOWN.
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Electrical
Issued 10 December 1987
Resolved
REPLACE FLEXIBLE HOSE ON PORT GENERATOR SECONDARY FUEL FILTER WITH METALLICTUBING OR USCG APPROVED NON-METALLIC HOSE.
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Lifesaving
Issued 10 December 1987
Resolved
SERVICE VESSEL'S LIFERAFTS AT AN APPROVED FACILITY IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987
Lifesaving
Issued 2 February 1987
Resolved
CONDUCT ANNUAL SERVICING OF SWITLIK LIFERAFT SERIAL #14 LOT 44 AT A COAST GUARD APPROVED FACILITY. VESSEL MAY NOT OPERATE NORTH OF 32 DEGREES NORTH OR SOUTH OF 32 DEGREES SOUTH UNTIL BOTTLE IS RECHARGED WITH PROPER CO2/N2 MOD TEMP MIXTURE.
Condition: Unknown
Due 2 February 1987
Resolved 2 February 1987
Lifesaving
Issued 2 February 1987
Resolved
PROVIDE SECOND LIFERAFT TO BRING ENTIRE VESSEL COMPLEMENT TO 24 PERSONS.
Condition: Unknown
Due 2 February 1987
Resolved 2 February 1987
Engineering
Issued 2 February 1987
Resolved
DEMONSTRTE PROPER OPERATION OF OILY WATER SEPARATOR.
Condition: Unknown
Due 2 February 1987
Resolved 2 February 1987
Engineering
Issued 10 June 1986
Resolved
SUBMIT PLANS FOR THE INSTALLATION OF AN ENGINE ORDER TELEGRAPH SYSTEM (EOT)BETWEEN THE PILOT HOUSE AND ENGINE ROOM. THE PLAS MUST BE SUBMITTED TO THE MARINE INSPECTION OFFICE NEW YORK, NEW YORK FOR APPROVAL PRIOR TO 31DEC86.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Lifesaving
Issued 10 June 1986
Resolved
SERVICE VESSEL'S TWO (2) INFLATABLE LIFERAFTS AT A USCG APPROVED LIFERAFT SERVICING FACILITY PRIOR TO 10 DECEMBER 1986 BUT NO LATER THAN VESSEL'S NEXT DRYDOCK EXAM.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986