Records from 1982 to 2016. Most recent: inspection, 31 August 2016.
Inspection history · 117
31 August 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5989038
26 July 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4391075
21 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4318053
28 February 2012
Plan Review (Other than "T")
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4541687
27 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4251795
18 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4226943
9 November 2010
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3887990
4 November 2010
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3884669
2 March 2010
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3688713
9 December 2009
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3648847
10 July 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3530234
24 December 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3384491
4 November 2008
Damage Survey · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3357434
7 October 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3340152
18 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3240756
29 May 2008
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3234575
23 April 2008
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3190322
25 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3136260
7 January 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3126179
15 October 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3080598
25 September 2007
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3065798
19 June 2007
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2966010
5 June 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2982090
2 March 2007
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2906553
25 October 2006
In-Service Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2807749
8 August 2006
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2740520
25 April 2006
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2617676
27 January 2006
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2574751
10 March 2005
Deficiency Check · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2301986
16 September 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2197547
6 February 2004
Periodic Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2001773
23 January 2004
Deficiency Check · Internal Structural Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1991745
8 September 2002
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1682100
26 March 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1491527
20 November 2001
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1076365
22 May 2001
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1065041
6 February 2001
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1426524
14 July 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213755
22 March 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386742
7 January 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 814448
23 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779144
16 June 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213754
20 May 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 802585
4 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793587
29 April 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1126590
23 March 1999
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1470975
2 February 1999
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1384020
23 July 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130367
27 April 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1123610
31 March 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1124578
24 March 1998
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1426048
25 October 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 111450
24 June 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 56728
10 June 1997
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1110328
30 May 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1109149
13 May 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1091606
13 May 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1102763
1 May 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 82942
30 April 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093181
14 April 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1374943
21 January 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1098440
13 January 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1097545
2 December 1996
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1418071
22 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 141190
17 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 170400
19 June 1996
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1080870
17 May 1996
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1090618
1 April 1996
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1371325
20 February 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 881357
9 February 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 875056
21 December 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 872822
21 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 114056
16 May 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921567
12 April 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382938
6 March 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 857760
8 July 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 867808
7 July 1994
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1176260
4 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 24503
28 March 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 693361
21 March 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 186670
17 March 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409094
24 March 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408949
21 March 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1154884
22 April 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443314
27 March 1992
Deficiency Check · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470625
12 March 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944584
18 November 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 170543
1 November 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932283
1 November 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 941478
25 October 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 940043
11 October 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 940070
20 June 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230319
19 June 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238999
10 June 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931842
3 June 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1038102
24 May 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927573
7 May 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231781
4 April 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239404
7 June 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 929417
2 May 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1226176
7 July 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1341572
17 May 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1340522
16 March 1989
Hull Examination · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1207811
9 March 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 899041
16 November 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1204371
24 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1307176
17 January 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 996610
13 December 1985
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1299617
6 March 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286952
23 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283980
25 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973488
21 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973485
21 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973487
20 April 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281364
11 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278704
29 November 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278881
22 July 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 970124
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 10 December 2009
Resolved
Piping in main engine space invloved in fire. Piping needs to be tested to ensure integrity of piping.
Action required: 705 - Other - as specified
Due 17 December 2009
Resolved 11 December 2009
Resolution: Recieved verification from OIM that piping was tested by Hiller Offshore to 900 psi.
Fire Fighting › Ventilation Systems › Fans
Issued 10 December 2009
Resolved
Auto-shutdown of ventilation for main engine space not tested after HALON system was discharged and serviced after fire. Test ventalation shutdown.
Action required: 705 - Other - as specified
Due 17 December 2009
Resolved 11 December 2009
Resolution: Received verification from OIM that ventilation shutdown operates correctly.
Lifesaving › Launching Appliances › Release Mechanism
Issued 29 May 2008
Resolved
Issued deficiency to provide satisfactory proof of testing of boat lifeboat davits release gear no later than 13 Jun 08 to the satisfaction of the attending USCG inspector or ABS surveyor.
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 12 June 2008
Resolution: Recieved test certificates.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 September 2007
Resolved
Renew brackets for Fire Extinguishers in Lifeboat #2.
Action required: 705 - Other - as specified
Resolved 25 September 2007
Resolution: Brackets renewed prior to completion of inspection
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 September 2007
Resolved
Provide properly maintained CO2 Extinguisher for fixed service on paint locker
Action required: 705 - Other - as specified
Resolved 25 September 2007
Resolution: Corrected before completion of inspection
Stability › Watertight Integrity › General
Issued 25 September 2007
Resolved
Seal watertight bulkhead penetrations in compresor room
Action required: 705 - Other - as specified
Resolved 25 September 2007
Resolution: Watertight penetrations were sealed before completion of inspection
Pollution Prevention/Response › Prevention Equipment › Automatic Back Pressure Shut-off
Issued 25 September 2007
Resolved
Make all fueling station hose nozzels Deadman Type
Action required: 705 - Other - as specified
Resolved 25 September 2007
Resolution: Corrected before completion of inspection
Fire Fighting › Ventilation Systems › Operating Controls
Issued 25 September 2007
Resolved
Exercise and lubricate all ventilation mushroom vent closures
Action required: 705 - Other - as specified
Resolved 25 September 2007
Resolution: All mushroom vent closures were operated and lubricated before completion of inspection
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 19 June 2007
Resolved
Demonstrate proper operation of purged/pressurized alarm system for electrical panels on drill floor.
Action required: 705 - Other - as specified
Due 19 July 2007
Resolved 19 June 2007
Resolution: Alarms demonstrated prior to departure from vessel.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 19 June 2007
Resolved
Remove hydraulic fluid from bilge of #2 lifeboat and identify/repair hydraulic leak if any.
Action required: 705 - Other - as specified
Due 19 June 2007
Resolved 19 June 2007
Resolution: Fluid was from spill-over during maintenance of starting system Fluid removed prior to departure from vessel.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 June 2007
Resolved
Renew markings for #4, #6, and spare lifebuoys IAW 46 CFR 108.649(e).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2007
Resolved 19 June 2007
Resolution: Lifebuoy markings renewed prior to departure from vessel.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 19 June 2007
Resolved
Amend operations manual to reflect maximum allowable air gap IAW API RP 95J. Maximum air gap allowed by operating manual is 54 feet, where actual air gap is 66 feet on date of inspection.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 24 December 2008
Resolution: Cleared per email of 10DEC08, ABS ltr 389463 of 01DEC08, Hercules Offshore memo to Hercules 201 OIM of 10DEC08, and MSC email from [name withheld] of 23DEC08.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 25 April 2006
Resolved
Provide treatment room IAW 46CFR108.210 to the satisfaction of [name withheld].
Due 25 May 2006
Resolved 8 August 2006
Fire Fighting › Structural - A Class Divisions › Doors
Issued 25 April 2006
Resolved
Repair all A-class doors leading into galley/mess area. Each must shut on their own and can not be latched open.
Due 2 May 2006
Resolved 2 May 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 April 2006
Resolved
Provide 3 copies of updated fire control plans to [name withheld]. Ensure updates for treatment room are included.
Due 25 May 2006
Resolved 8 August 2006
Resolution: Approved fire control plan.
Electrical › Electric Generation Source (service) › Generator
Issued 10 March 2005
Resolved
Provide caps or plugs below valve on fuel filters/separators for all A/C and D/C generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 7 April 2005
Electrical › Electric Generation Source (service) › Generator
Issued 10 March 2005
Resolved
Remove wire nuts on #3 generator and replace with suitable splice.
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 7 April 2005
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 March 2005
Resolved
Label remote fuel oil shutoff on emergency generator.
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 7 April 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 10 March 2005
Resolved
Replace flex hoses on #3 Generator CO2 system.
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 7 April 2005
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 March 2005
Resolved
Repair/replace doors accessing #3 generator space to properly close and seal for adequate fire protection.
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 7 April 2005
Construction/Loadline › Structures › Door
Issued 10 March 2005
Resolved
Adjust watertight door outside of galley for proper seal and watertight integrity.
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 7 April 2005
Lifesaving › Lifeboat › Propulsion Starting System
Issued 10 March 2005
Resolved
Repair fuel oil system on #2 lifeboat and prove proper operation of lifeboat propulsion. Standby vessel "KIT KAT" must remain near rig until lifeboat is operational.
Action required: 705 - Other - as specified
Due 14 March 2005
Resolved 10 March 2005
Resolution: Rig repaired engine prior to inspectors departing rig.
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 10 March 2005
Resolved
Conduct total rig shutdown during next rig movement.
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 7 April 2005
Lifesaving › Lifebuoys
Issued 18 February 2004
Resolved
Replace reflective tape on #4 and #5 life ring buoy.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Lifesaving › Lifeboat Equipment
Issued 18 February 2004
Resolved
Renew expired water and pyro on life boats.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Documentation › Certificates/Documents
Issued 18 February 2004
Resolved
Update ship radio station license with new owner (company). LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 14 March 2004
Electrical › Electric Generation Source (emergency)
Issued 18 February 2004
Resolved
Prove proper operation of automatic starting of emergency generator upon loss of power.
Action required: 705 - Other - as specified
Due 25 February 2004
Resolved 24 March 2004
Electrical › Electric Generation Source (service)
Issued 18 February 2004
Resolved
Demonstrate proper operation of reverse power relay, loss of lube oil, and overspeed trips.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 1 May 2004
Resolution: Received email certification from [name withheld] & rig OIM that problem with low lube trips was found to be operator error, and that problem is corrected.
Construction/Loadline › Structures
Issued 18 February 2004
Resolved
Demonstrate proper operation of all local and remote watertight door indicators.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Engineering › Sea-water System (primary cooling)
Issued 18 February 2004
Resolved
Provide gauging report or renew raw water manifold and adjacent piping. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Electrical › Electric Generation Source (service)
Issued 18 February 2004
Resolved
Repair lube oil leak on prime mover for #2 DC Generator.
Action required: 705 - Other - as specified
Due 25 February 2004
Resolved 24 March 2004
Engineering › Compressed Air System (control)
Issued 18 February 2004
Resolved
Provide manufactors data sheets (U-1As) for air system dryers for control air system.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Electrical › Electric Generation Source (service)
Issued 18 February 2004
Resolved
Repair lube oil leak on prelube pump for #3 A/C Generator.
Action required: 705 - Other - as specified
Due 25 February 2004
Resolved 24 March 2004
Fire Fighting › Structural - A Class Divisions
Issued 18 February 2004
Resolved
Provide closure for ventilation opening to emergency generator room to ensure "A" class boundary.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Lifesaving › Launching Appliances
Issued 18 February 2004
Resolved
Remove satellite dish from port boat davit or provide documentation showing specific approval of installation on water craft davit. LEGACY COMPONENT DESC: Davit
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Electrical › Electrical Distribution System (service)
Issued 18 February 2004
Resolved
Provide identification for circuit breakers on #2 distribution panel in DC room.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Electrical › Electrical Distribution System (service)
Issued 18 February 2004
Resolved
Replace missing labels for breakers on main switch board in DC Room.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 18 February 2004
Resolved
Remove test pressure on fuel transfer hose. LEGACY COMPONENT DESC: Transfer Hose
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Fire Fighting › Miscellaneous Items
Issued 18 February 2004
Resolved
Remove flammable liquids and aerosols from water maker room. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Action required: 705 - Other - as specified
Due 19 February 2004
Resolved 24 March 2004
Construction/Loadline › Structures
Issued 18 February 2004
Resolved
Replace hardware on galley door.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 18 February 2004
Resolved
Replace missing halon bottles and CO2 actuator bottles on fixed systems for both the DC Generator room and AC Generator room. Test system and provide service report to CORMS.
Action required: 705 - Other - as specified
Due 19 February 2004
Resolved 21 February 2004
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 18 February 2004
Resolved
Replace existing exhaust lagging on right bank of #1 AC Generator.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Fire Fighting › Structural Fire Protection - General
Issued 18 February 2004
Resolved
Demonstrate proper operation of fire door and fusible link system for scullery fire doors.
Action required: 705 - Other - as specified
Due 25 February 2004
Resolved 18 February 2004
Lifesaving › Lifeboat
Issued 18 February 2004
Resolved
Demonstrate proper operation of limit switches on port life boat.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Engineering › Pressure Vessel › Relief Valve
Issued 18 February 2004
Resolved
Demonstrate proper operation of all air receiver and dry bulk tank relief valves.
Action required: 705 - Other - as specified
Due 18 March 2004
Resolved 24 March 2004
Electrical › Electrical Distribution System (service)
Issued 18 February 2004
Resolved
Demonstrate proper operation for purge system and associated alarms for 3rd party mud logging shack in Class 1, Div. 1 location and reroute ventilation intake to area outside hazardous location.
Action required: 705 - Other - as specified
Due 18 February 2004
Resolved 18 February 2004
Fire Fighting › Structural Fire Protection - General
Issued 18 February 2004
Resolved
Demonstrate proper operation of fire door and fusible link system for galley fire door.
Action required: 705 - Other - as specified
Due 25 February 2004
Resolved 24 March 2004
Construction/Loadline › Hull
Issued 23 January 2004
Resolved
Gauge up 6 inches from deck on outer shell in #3 Starboard tank.
Action required: 705 - Other - as specified
Resolved 13 February 2004
Construction/Loadline › Hull
Issued 23 January 2004
Resolved
Cut at least 3 access holes in false deck in starboard store room and provide gauging to hull.
Action required: 705 - Other - as specified
Resolved 13 February 2004
Construction/Loadline › Penetrations
Issued 23 January 2004
Resolved
Repair striker plate for sounding tube in #8 starboard tank.
Action required: 705 - Other - as specified
Resolved 19 February 2004
Construction/Loadline › Hull › Bottom Plating
Issued 23 January 2004
Resolved
Provide gauging or renew plate below suction piping inlet in #8 starboard tank.
Action required: 705 - Other - as specified
Resolved 12 February 2004
Construction/Loadline › Structures
Issued 23 January 2004
Resolved
Crop and renew four areas (holes) in overhead plating in #7 center tank. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Resolved 24 March 2004
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 January 2004
Resolved
Crop and renew hole in #4 center tank to #1 potable water tank.
Action required: 705 - Other - as specified
Resolved 12 February 2004
Construction/Loadline › Hull
Issued 23 January 2004
Resolved
Clean #7 center tank for further inspection by ABS or USCG.
Action required: 705 - Other - as specified
Resolved 12 February 2004
Construction/Loadline › Hull
Issued 23 January 2004
Resolved
Prepare #2 Port and #2 Starboard drill water tanks and mud pits for further inspection by ABS or USCG.
Action required: 705 - Other - as specified
Resolved 12 February 2004
Operations/Management › Drills/Instruction
Issued 26 April 2002
Resolved
Unit stacked with reduced crew, prior to returning to operation conduct fire and boat drills in the presence of a CG Marine Inspector. LEGACY COMPONENT DESC: Fire
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 31 March 2003
Resolution: Conducted satisfactory fire and abandon rig drills.
Accommodation/Occupational Safety
Issued 6 February 2001
Resolved
Reattach lowest stair iwa aft leg yoke room behind mud shaker space.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Navigation
Issued 6 February 2001
Resolved
Renew all inoperative water tight door alarm lights on control room panel.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Lifesaving
Issued 6 February 2001
Resolved
Replace crazed (opaque) lifeboat driver viewing windows.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Construction/Loadline
Issued 6 February 2001
Resolved
Replace worn expansion joints on sea water manifold suction line, starboardside.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Lifesaving
Issued 6 February 2001
Resolved
Provide approved Emergency Evacuation Plan for the vessel at location.
Condition: Unknown
Due 3 March 2001
Resolved 12 March 2001
Deck/Cargo
Issued 6 February 2001
Resolved
Provide guage readings iaw diagram given on rig air receiver.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Construction/Loadline
Issued 6 February 2001
Resolved
Make permanent repair to leaky repair iwo #2 Sea Water/fire pump manifold.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Electrical
Issued 6 February 2001
Resolved
Isolate and correct all electriacl ground faults (2) AC generators and Emergency generator.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Fire Fighting
Issued 6 February 2001
Resolved
Verify fire dampers in scullery opening functions properly and has fusible link.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Lifesaving
Issued 6 February 2001
Resolved
Conduct Fire and boat drill.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Deck/Cargo
Issued 6 February 2001
Resolved
Provide relief valve function certifications or prove proper operation of all safety releif valves.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Lifesaving
Issued 6 February 2001
Resolved
Conduct test of general quarters alarm throughout vessel.
Condition: Unknown
Due 3 March 2001
Resolved 12 March 2001
Deck/Cargo
Issued 6 February 2001
Resolved
Prepare all pressure vessels for internal inspection.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Deck/Cargo
Issued 6 February 2001
Resolved
Provide detailed permanent repair proposal for leaky mud pits.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Electrical
Issued 6 February 2001
Resolved
Provide permanant, secure method of holding sub pump (for charging sea water manifold) power supply cable such that it does not impede access to life ring apparatus.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Deck/Cargo
Issued 6 February 2001
Resolved
Conduct function tests of all emergency Shut-downs.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Electrical
Issued 6 February 2001
Resolved
PRovide explosion proof fittings in all hazardous zones.
Condition: Unknown
Due 6 March 2001
Resolved 12 March 2001
Lifesaving
Issued 22 March 2000
Resolved
RENEW PORT, STARBOARD AND AFT VIEWING PORTS FROM OPERATOR'S STATION ON BOTHLIFEBOATS.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Lifesaving
Issued 22 March 2000
Resolved
CROP AND RENEW WASTED AND HOLED HAND RAILS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Electrical
Issued 22 March 2000
Resolved
CONDUCT AND LOG SATISFACTORY TEST OF RIG'S EMERGENCY TOTAL RIG SHUT-DOWN FROM ALL STATIONS.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Electrical
Issued 22 March 2000
Resolved
RENEW FUEL OIL SUPPLY AND RETURN FLEX LINES ON AC GENERATORS AS NECESSARY. RENEW CHAFFED ELECTRICAL AND LUBE OIL LINES AS NECESSARY, REMOVE DEAD END WIRING IN AC GENERATOR ROOM.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Accommodation/Occupational Safety
Issued 23 March 1999
Resolved
DOOR ON O2 DECK LEADING TO OUTSIDE SPACES DID NOT CLOSE PROPERLY.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Accommodation/Occupational Safety
Issued 23 March 1999
Resolved
L/B EGRESS PLACARDS NEED TO BE REPLACED.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Fire Fighting
Issued 23 March 1999
Resolved
PROVE PROPER OPERATION OF FIRE STATION NO. 1.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 2 February 1999
Resolved
COMPLETE PHASE II OF SEILODD & PROVIDE COPY OF ABS REPORT TO [name withheld], TX.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Construction/Loadline
Issued 2 February 1999
Resolved
MAKE #9 PORT & STBD DRILL WATER TANKS AVAILABLE FOR INSPECTION OR PROVIDE ABS REPORT INDICATING EXAMINATION OF TANKS.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Construction/Loadline
Issued 2 February 1999
Resolved
COMPLETE REPAIRS TO #7 CENTER VOID TO THE SATISFACTION OF ABS & PROVIDE COPY OF REPORT TO [name withheld], TX.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Electrical
Issued 24 March 1998
Resolved
REPLACE ELECTRICAL SOCKET BEHIND DRYER IN CHANGE ROOM.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Electrical
Issued 24 March 1998
Resolved
PROVIDE MISSING PLUG FOR EXPLOSION PROOF BOX ON DRILL FLOOR.
Condition: Unknown
Due 24 March 1998
Resolved 30 March 1998
Lifesaving
Issued 24 March 1998
Resolved
REPAIR COXSWAIN WINDOW HINGES ON NO 2 LIFEBOAT.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
REPLACE PLACARD ON NO 2 LIFEBOAT WINCH.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
HAVE THIRD PARTY EVALUATE AND REPAIR FIBERGLASS CRACKS AND DAMAGE ON NO 2 LIFEBOAT.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
REPLACE/REPAIR SHAFT PACKING ON BOTH LIFEBOATS PROPELLOR SHAFTS.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
REPLACE FALLS AND CONDUCT WEIGHT TEST ON NO 1 LIFEBOAT.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
COMPLETE IMPLEMENTATION OF 46CFR108/109 TRAINING REQUIREMENTS.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Unknown
Issued 24 March 1998
Resolved
ATTACH BRACKETS ON WATER HEATER.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
REPLACE 2 LIFE PRESERVERS DUE TO AIR LEAK.
Condition: Unknown
Due 24 March 1998
Resolved 30 March 1998
Electrical
Issued 24 March 1998
Resolved
PROVIDE LIGHTBULBS FOR BURNED OUT LIGHTBULF ON WT DOOR INDICATOR ON MUD PUMP ROOM DOOR.
Condition: Unknown
Due 24 March 1998
Resolved 30 March 1998
Lifesaving
Issued 24 March 1998
Resolved
REPAIR EXHAUST LEAK IN NO 2 LIFEBOAT.
Condition: Unknown
Due 31 March 1998
Resolved 31 March 1998
Lifesaving
Issued 24 March 1998
Resolved
PROVE PROPER OPERATION OF AIR RELIEF VALVES ON: HIGH PRESSURE AIR RECIEVER, AIR RECEIVER ON DRILL FLOOR, AND ALL BULK TANK AIR RECEIVERS.
Condition: Unknown
Due 13 April 1998
Resolved 15 April 1998
Lifesaving
Issued 24 March 1998
Resolved
INCREASE WATER PRESSURE TO MUD PIT ROOM EYEWASH STATION, TO ENSURE WATER CAN REACH A PERSON EYES.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Construction/Loadline
Issued 24 March 1998
Resolved
REFIT GALLEY DOOR TO MAIN DECK SO THAT IT CLOSES SECURELY. (NO LIGHT SHOWING.)
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
REPAIR FUEL LEAKS ON ENGINE ON NO 1 LIFEBOAT.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Electrical
Issued 24 March 1998
Resolved
FIND AND FIX GROUND APPEARING ON MAIN AC GEN SWITCHBOARD AND EMERGENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
ATTACH DATA PLACARD TO WINCH STANCION ON NO 1 LIFEBOAT.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
REPAIR HYDRALIC FLUID TANK LEAK IN NO 2 LIFEBOAT.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
TIGHTEN STEERING CABLE BOLT ON NO 2 LIFEBOAT.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998
Resolved
CONDUCT WEIGHT TEST ON NO 2 LIFEBOAT
Condition: Unknown
Due 31 March 1998
Resolved 31 March 1998
Electrical
Issued 14 April 1997
Resolved
REPLACE LAGGING ON EXHAUST MANIFOLDS FOR A/C GENERATORS.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Fire Fighting
Issued 14 April 1997
Resolved
REPLACE ACTUATION HOSE TO HALON CYLINDER FOR THE A/C GENERATOR ROOM.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Electrical
Issued 14 April 1997
Resolved
REPAIR TACHOMETER FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Fire Fighting
Issued 14 April 1997
Resolved
OBTAIN APPROPRIATE PANTS FOR BOTH FIREMAN'S OUTFITS.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Lifesaving
Issued 14 April 1997
Resolved
FREE UP STIFF STEERING IN BOTH LIFEBOATS.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Lifesaving
Issued 14 April 1997
Resolved
REMOVE AIR BUBBLE IN LIFEBOAT #2 COMPASS.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Lifesaving
Issued 14 April 1997
Resolved
REPLACE AS NEEDED DOOR GASKETS IN BOTH LIFEBOATS.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Construction/Loadline
Issued 2 December 1996
Resolved
DESCALE #9 PORT AND STBD S/W BALLAST TANKS IN THE UPPER HULL AND MAKE READYFOR INSPECTION BY US COAST GUARD.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Construction/Loadline
Issued 2 December 1996
Resolved
CONDUCT NON DESTRUCTIVE TESTING IN THE PRESENCE OF A US COAST GUARD MARINE INSPECTOR OF THE AREA AROUND THE DOUBLERS IN WAY OF THE #1 STBD VOID IN THEMAT AND THE #4 STBD VOID IN THE MAT IAW INSPECTION NOTE #3 ISSUED BY MORMS 08JUL94. SUBMIT REPORT TO MORMS.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Construction/Loadline
Issued 2 December 1996
Resolved
CLEAN AND DESCALE BOTTOM PLATING IN THE #3 PORT AND STBD S/W BALLAST TANKS IN THE UPPER HULL AND MAKE READY FOR INSPECTION BY US COAST GUARD.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Construction/Loadline
Issued 2 December 1996
Resolved
PROVIDE GAUGE READINGS OF SALT WATER SUCTION LINES TO FIRE MAIN AND FIRE MAIN & BILGE LINES TO US COAST GUARD FOR REVIEW.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Unknown
Issued 2 December 1996
Resolved
REPAIRS RAILING ON THE MAIN DECK STBD SIDE APPROX. THIRTY FEET FWD OF THE OVERBOARD SALT WATER SUCTION LINE.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Construction/Loadline
Issued 2 December 1996
Resolved
CONDUCT NON DESTRUCTIVE TESTING IN WAY OF THE STBD BOW AREA RADIUS PLATE INWAY OF THE MOON POOL IN THE PRESENCE OF A US COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Construction/Loadline
Issued 1 April 1996
Resolved
RELABEL CONTROLLERS FOR DRILL WATER PUMPS #1 AND #2 TO READ "FIRE/DRILL WATER PUMP #(1/2)."
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 April 1996
Resolved
PERFORM FUNCTIONAL TEST OF FIXED CO2 SUPPRESSION SYSTEM FOR #3 GENERATOR.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 April 1996
Resolved
INSTALL A 30 BY 30 INCH MESH FLAME SCREEN ON PAINT LOCKER VENT.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 April 1996
Resolved
CROP AND RENEW WASTED FIREMAIN PIPING AT FIRE STATION #6.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 April 1996
Resolved
REPLACE APPLICATOR AT FIRE STATION #12.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Navigation
Issued 1 April 1996
Resolved
REPLACE CRACKED LENS TO PORT AMD STBD LEG OBSTRUCTION LIGHTS.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Construction/Loadline
Issued 1 April 1996
Resolved
REPLACE FAULTY PRESSURE GAUGE FOR DRILL WATER PUMP #1.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 1 April 1996
Resolved
PRIOR TO DRILLING, REPAIR AND PERFORM FUNCTIONAL TEST OF TOTAL RIG SHUTDOWNFROM ALL STATIONS.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 1 April 1996
Resolved
PRIOR TO DRILLING, REPAIR AND PERFORM FUNCTIONAL TEST OF AUTOMATIC BUS TRANSFER SYSTEM FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 1 April 1996
Resolved
PERFORM FULL FUNCTIONAL TESTING OF #3 GENERATOR UNDER A FULL LOAD.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 1 April 1996
Resolved
HAVE A COAST GUARD MARINE INSPECTOR EXAMINE FINAL INSTALLATION AND WORKMANSHIP OF #3 GENERATOR.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 1 April 1996
Resolved
INSTALL EMERGENCY LIGHTING IN MUDPIT ROOM.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 April 1996
Resolved
HAVE A COAST GUARD MARINE INSPECTOR EXAMINE FINAL INSTALLATION AND WORKMANSHIP OF FIXED CO2 SUPPRESSION SYSTEM FOR #3 GENERATOR.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Engineering
Issued 1 April 1996
Resolved
REPLACE FLAME SCREENS TO LUBE OIL TANK IN MUD PUMP ROOM.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Construction/Loadline
Issued 1 April 1996
Resolved
LABEL ALL BILGE MANIFOLD VALVES.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 April 1996
Resolved
REPLACE FIREMAIN JUMPER HOSE TO DRILL FLOOR WITH A HOSE EQUIVALENT TO SAE J-1942 SPECIFICATIONS.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Fire Fighting
Issued 1 April 1996
Resolved
REVISE AND SUBMIT FOR COAST GUARD APPROVAL FIRE CONTROL PLAN.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 1 April 1996
Resolved
REPAIR HIGH WATER TEMPERATURE ALARM TO #1 AC GENERATOR.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Electrical
Issued 1 April 1996
Resolved
REMOVE EXCESS OIL UNDER EMERGENCY GENERATOR UNIT.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Lifesaving
Issued 12 April 1995
Resolved
HAVE QUALIFIED TECHNICIAN INSPECT AFT SECTION OF RELEASING GEAR IN BOTH LIFEBOATS.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 12 April 1995
Resolved
INSTALL ADDITIONAL FIRE HOSE STATION FOR LOWER QUARTERS WITH ASSOCIATED EQUIPMENT. PERFORM HYDROTEST OF NEW FIREMAIN PIPING TO 1.5 X MAWP. SUBMITREVISED FIRE AND SAFETY PLAN TO [name withheld], LA.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Electrical
Issued 12 April 1995
Resolved
RESTRAP WIRE RUNS ON DRILL FLOOR AND DERRICK AS INDICATED.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 12 April 1995
Resolved
HAVE QUALIFIED TECHNICIAN PROOF TEST PROPER OPERATION OF BREATHING AIR SYSTEM IN BOTH LIFEBOATS IN ACCORDANCE WITH SHAAT WATERCRAFT OPERATIONS MANUAL.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Navigation
Issued 12 April 1995
Resolved
PLACE ALL OBSTRUCTION LIGHTS ON SAME HORIZONTAL PLANE.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Electrical
Issued 12 April 1995
Resolved
MAKE BOTH MUD PIT ROOM DOORS SELF CLOSING AND GAS TIGHT.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 12 April 1995
Resolved
PROVIDE REMOTE VENTILATION SHUTDOWNS LOCATED OUTSIDE OF THE SPACE PROTECTED. PROOF TEST PROPER OPERATION FOLLOWING INSTALLATION.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Construction/Loadline
Issued 17 March 1994
Resolved
SUBMIT REPAIR PROPOSAL TO MSO MORGAN CITY FOR THE FOLLOWING AREAS:_x001C_ 1. DOUBLER LOCATED ON 1S (PERMANENTLY FLOODED TANK)._x001C_ 2. DOUBLER LOCATED ON 4S (PERMANENTLY FLOODED TANK).
Condition: Unknown
Due 17 March 1994
Resolved 17 March 1994
Fire Fighting
Issued 24 March 1993
Resolved
Provide relief system for fire pumps at 125 psig.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Fire Fighting
Issued 24 March 1993
Resolved
Replace shaft & repair no 1 fire pump as necessary.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Construction/Loadline
Issued 24 March 1993
Resolved
Replace flex connection on bilge pump.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Electrical
Issued 24 March 1993
Resolved
Provide explosion proof general alarm bell in mud pit room.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Construction/Loadline
Issued 24 March 1993
Resolved
Repair bilge suction strainer.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Electrical
Issued 24 March 1993
Resolved
Label breakers & install blanks as necessary in distribution panel in a/c generator room.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Accommodation/Occupational Safety
Issued 24 March 1993
Resolved
Perform hydrostatic test of -misd,uresucussitator bottle.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Fire Fighting
Issued 24 March 1993
Resolved
Add additional fire station to cover rig floor. Installation & testing to be to the satisfaction of the attending USCG inspector.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Lifesaving
Issued 24 March 1993
Resolved
Replace linethrowing gun.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Deck/Cargo
Issued 24 March 1993
Resolved
Replace fast line limit switch in port crane.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Fire Fighting
Issued 24 March 1993
Resolved
Provide oxygen detection meter for fireman's outfit.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Construction/Loadline
Issued 27 March 1992
Resolved
COMPLETE UNDERWATER SWIMBY OF MAT BOTTOM DURING NEXT RIG MOVE.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Electrical
Issued 27 March 1992
Resolved
RENEW BOTH POWER COILS RUNNING TO MOTOR ON OUTBOARD SHAKER IN SHALE SHAKER AREA.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Fire Fighting
Issued 27 March 1992
Resolved
REPAIR GENERAL ALARM BELLS IN MUD PITS AND PROVIDE A GENERAL ALARM BELL IN BOTH THE SHALE SHAKER AREA AND UNDER CANTILEVER.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Electrical
Issued 27 March 1992
Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAY ON #2 A/C GENERATOR.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Engineering
Issued 27 March 1992
Resolved
HYDROSTATICALLY TEST AND MARK FUEL TRANSFER HOSES IN ACCORDANCE WITH 33 CFR154.500.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Electrical
Issued 27 March 1992
Resolved
REPAIR REMOTE RIG SHUTDOWNS.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Construction/Loadline
Issued 12 March 1992
Resolved
COMPLETE UNDERWATER HULL SURVEY AT NEXT RIG MOVE OR BY ABOVE DATE.
Condition: Unknown
Due 12 April 1992
Resolved 1 April 1992
Documentation
Issued 10 June 1991
Resolved
NO MORE THAN 65 PERSONS SHALL BE ALLOWED ON BOARD AT ANY ONE TIME. NO MORETHAN 50 PERSONS SHALL BE ALLOWED ON BOARD MORE THAN 13 HOURS IN ANY CONSECUTIVE 24 HOUR PERIOD.
Condition: Unknown
Due 10 June 1991
Resolved 10 June 1991
Lifesaving
Issued 10 June 1991
Resolved
PROVIDE SUFFICIENT USCG APPROVED LIFERAFTS TO ACCOMODATE 100% OF THE TOTAL PERSONS ALLOWED. (THIS REQUIREMENT IN EFFECT UNTIL TOTAL PERSONS ALLOWED IS REDUCED SUCH THAT THE LIFEBOATS ARE CAPABLE OF ACCOMODATING 200% TOTAL PERSONS ON BOARD)
Condition: Unknown
Due 10 June 1991
Resolved 10 June 1991
Lifesaving
Issued 10 June 1991
Resolved
PROVIDE SUFFICIENT USCG APPROVED TYPE I PERSONAL FLOTATION DEVICES TO ACCOMODATE 125% OF ALL PERSONS ON BOARD AT ANY ONE TIME.
Condition: Unknown
Due 10 June 1991
Resolved 10 June 1991
Electrical
Issued 4 April 1991
Resolved
PROPERLY HANG FWD SUBSTRUCTURE LIGHT.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991
Resolved
CONDUCT A WEIGHT AND OPERATIONAL TEST OF THE #2 LIFEBOAT IN THE PRESENCE OFA COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Electrical
Issued 4 April 1991
Resolved
PROVIDE SUPPORTS FOR AND PROPERLY HANG WIRE FOR TRIP TANK PUMP.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Electrical
Issued 4 April 1991
Resolved
PROVIDE SAFETY LEASHES FOR ALL BEAM LAMP MOUNTED OVERHEAD LIGHTS IN ALL CLASSIFIED AREAS (ESPECIALLY RIG FLOOR AND SHAKER AREA).
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Electrical
Issued 4 April 1991
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Electrical
Issued 4 April 1991
Resolved
PROVIDE SUPPORT FOR AN PROPERLY HANG WIRE FOR PORT SUBSTRUCTURE LIGHT.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Navigation
Issued 4 April 1991
Resolved
REPAINT PORT AND STBD RUNNING LIGHT SCREENS AS PER NAVIGATION RULES.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Electrical
Issued 4 April 1991
Resolved
PROVIDE SUPPORTS FOR AND PROPERLY HANG ALL OVERHEAD HORIZONTAL WIRE RUNS ONRIG FLOOR.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Electrical
Issued 4 April 1991
Resolved
PROVIDE PURGED OR EXPLOSION PROOF BOX FOR TOTCO ROTARY TORQUE INSTRUMENTS (2 EACH) FWD/AFT SUBSTRUCTURE._x001C_
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Navigation
Issued 4 April 1991
Resolved
PROVIDE APPROVED OPERATING MANUAL REVISED AS REQUIRED BY 46 CFR 109.121.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Construction/Loadline
Issued 2 May 1990
Resolved
REPLACE MISSING BOLTS AND NUTS FOR DECK COVER OF THE #6 PORT VOID TANK.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Fire Fighting
Issued 2 May 1990
Resolved
REPAIR OR REMOVE FIRE ALARM SYSTEM.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Fire Fighting
Issued 2 May 1990
Resolved
REPLACE SPARE SCBA FOR FIREMAN'S OUTFIT IN VICINITY OF PORT BOAT DECK.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 2 May 1990
Resolved
SECURE COMMS WIRING ON PORT BOAT DECK.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 2 May 1990
Resolved
INSTALL STUFFING TUBES PROPERLY FOR WIRES PENETRATING WATERTIGHT BULKHEADS IN COMPRESSOR ROOM.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 2 May 1990
Resolved
REPLACE FUEL HOSE WITH APPROVED FUEL HOSE ON AFT EMD DIESEL.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990
Resolved
REPLACE BRASS PETCOCKS ON ALL FUEL OIL FILTERS ON BOTH EMD AND A/C GENERATOR WITH STEEL FITTINGS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 2 May 1990
Resolved
REPAIR MUDPIT SUPPLY FAN.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Deck/Cargo
Issued 2 May 1990
Resolved
TEST ALL BULK TANK RELIEF VALVES IN PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 16 March 1989
Resolved
MAKE PERMANENT REPAIRS TO THE PUNCTURE HOLE ABOUT 2"X3" LOCATED ON THE TANKTOP OF #1S PERMANENTLY FLOODED TANK APPROXIMATELY 15' AFT OF THE BOW.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Unknown
Issued 9 March 1989
Resolved
OBTAIN LOAD LINE CERTIFICATE.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
DEMONSTRATE OPERATION OF PORT SIDE WASTE OIL SHUTDOWN.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
CONDUCT UNDERWATER PORTION OF EXAM IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
OPEN WASTE WATER TANK DUMP VALVE, LOCATED IN TANK 4 CL FOR EXAMINATION.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
RENEW BOTH SUCTION AND PRESSURE SIDE EXPANSION JOINTS FOR FIRE PUMP.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
INSTALL FLAME SCREENS ON AC GENERATOR RAYCOR FUEL OIL STRAINERS.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
INSTALL APPROVED VALVES OR PLUGS ON DC GENERATOR RAYCOR FUEL OIL STRAINERS.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
RENEW DC GENERATOR EXPANSION JOINTS IN COOLANT WATER PIPING.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
REMOVE EXPANSION JOINTS IN FUEL SERVICE PIPING ON BOTH FUEL SERVICE PUMPS FOR DC GENERATOR DAY TANK AND REPLACE WITH HARD PIPING.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
INSTALL CAP ON FUEL FILL PIPE FROM DC GENERATOR DAY TANK.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
COMPLETE SHALE SHAKER UPGRADE AND MAKE IT AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Unknown
Issued 9 March 1989
Resolved
REPAIR DRILLERS CONSOLE PURGE AIR ALARM.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Lifesaving
Issued 13 December 1985
Resolved
CONDUCT WEIGHT TESTS INCLUDING EXAMINATION OF THE DISENGAGING APARATUS, THEWINCH CONTROLS AND THE LIMIT SWITCHES FOR THE #1 AND #2 LIFEBOATS IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TO THE NEXT RIG MOVE OR NO LATERTHAN 10 JANUARY 1986 WHICHEVER COMES FIRST.
Condition: Unknown
Due 13 December 1985
Resolved 13 December 1985
Deck/Cargo
Issued 23 January 1985
Resolved
ADJUST THE MECHANICAL PACKING ON THE MUD TRANSFER PUMP TO ELIMINATE LEAKAGE.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Electrical
Issued 23 January 1985
Resolved
REPAIR THE HOSPITAL ROOM EMERGENCY LIGHT.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 23 January 1985
Resolved
INSTALL A BACKUP ALARM ON THE FORKLIFT.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Electrical
Issued 23 January 1985
Resolved
REMOVE THE PLASTIC CLIPS ON THE VERTICAL WIRE RUNS THROUGHOUT THE RIG AND REPLACE THEM WITH METAL CLIPS.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Accommodation/Occupational Safety
Issued 23 January 1985
Resolved
MAKE LEGIBLE THE TAIL ROTOR WARNING SIGN FOR THE HELICOPTER DECK.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Accommodation/Occupational Safety
Issued 23 January 1985
Resolved
TEST THE RELIEF VALVES ON THE #1 AND #2 AIR RECEIVER.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Electrical
Issued 23 January 1985
Resolved
REPLACE OR REPAIR THE TACHOMETERS ON THE TWO MAIN AC GENERATORS.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Electrical
Issued 23 January 1985
Resolved
REPAIR THE GENERAL ALARM BELLS IN THE P-TANK ROOM AND THE COMPRESSOR ROOM.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 23 January 1985
Resolved
REPAIR THE PURGE ALARM ON THE DRILL FLOOR GAS DETECTORS.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Electrical
Issued 23 January 1985
Resolved
ADJUST THE OVERSPEED TRIP ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Fire Fighting
Issued 23 January 1985
Resolved
REPAIR THE MUD PIT ROOM FIRE STATION VALVE.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 21 May 1984
Resolved
MAKE AVAILABLE FOR INSPECTION ALL MUD PIT DUMP VALVES.
Condition: Unknown
Due 21 June 1984
Resolved 21 May 1984
Construction/Loadline
Issued 21 May 1984
Resolved
CONDUCT A VIDEO EXAMINATION OF THE MAT BOTTOM PLATING AND THE MAT SKIRT ANDSIDE SHELL.
Condition: Unknown
Due 21 June 1984
Resolved 21 May 1984
Unknown
Issued 21 May 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE NORDRILL OILER, DN641320.
Condition: Unknown
Due 21 June 1984
Resolved 21 May 1984
Fire Fighting
Issued 11 January 1984
Resolved
MAKE HALON SYSTEM FOR DC GENERATOR SPACE OPERABLE WITHOUT DELAY.
Condition: Unknown
Due 12 January 1984
Resolved 11 January 1984
Unknown
Issued 11 January 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL NORDRILL OILER DN641320
Condition: Unknown
Due 11 January 1984
Resolved 11 January 1984
Unknown
Issued 29 November 1983
Resolved
MAKE REPAIRS TO THE REVERSE POWER RELAY FOR THE #1 AC GENERATOR AND TEST TOTHE SATISFACTION OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE NORDRILL OILER, DN641320.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
INSTALL AN AUDIBLE OR A VISUAL ALARM ON THE AIR PURGE SYSTEM ON THE DRAW WORKS CONTROL CONSOLE IN ACCORANCE WITH NFPA 496.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION THE #1 AND #2 CEMENT TANKS.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION ALL THREE AIR RECEIVERS AND TEST THE RELIEF VALVES.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
RELOCATE TWO DRY CHEMICAL FIRE EXTINGUISHERS ON THE HELO DECK AWAY FROM THEHELICOPTER APPROACH.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
REPAIR OR REPLACE THE AIR PURGE ALARM ON THE CAMERON CHOKE UNIT CONSOLE.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
DEMONSTRATE THE PROPER OPERATION OF THE GENERAL ALARM BELLS AND LIGHTS IN THE ENGINEERING SPACES AND THE MUD PIT.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
PROVIDE THE REQUIRED AUXILIARY LINE FOR THE LINE THROWING APPLIANCE.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
PROVIDE CORRECT HEAT RESISTANCE METAL SHIELDS AROUND THE FUEL FILTER BOWLS FOR THE #1 AD #2 DC GENERATOR.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
PROVIDE PROTECTIVE SHIELDS AROUND THE PULLEY AND THE FRONT OF THE AC GENERATOR.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
POST WIRING DIAGRAMS IN ALL MOTOR CONTROLERS AS REQUIRED BY 46 CFR 111.05-10.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
REPLACE THE MISSING EXHAUST INSULATION TO THE TURBOCHARGERS IN #1 AC GENEATOR.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
DEMONSTRATE THE PROPER OPERATION OF THE VENTILATION FAILURE ALARM PANEL.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
INSTALL A FLAME SCREEN IN THE PAINT LOCKER VENT.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983
Unknown
Issued 29 November 1983
Resolved
LABEL LIGHTING SUPPLIED FROM THE EMERGENCY SWITCHBOARD WITH A RED LETTER "E" AS REQUIREDY BY 46 CFR 108.639.
Condition: Unknown
Due 29 November 1983
Resolved 29 November 1983