MARINER SERVICE

MARINER SERVICE is a 1982 offshore supply vessel. The Coast Guard has recorded 51 inspections since 1982, most recently in September 2016, along with 193 deficiencies.

Records from 1982 to 2016. Most recent: inspection, 7 September 2016.

Built
1982
Last inspected
7 September 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8121886 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB3188
Flag
VANUATU
366884350, 368370000 (licence lapsed)
Maury page id
psix-54118

Inspections, by type

…with no type recorded3
Years with a record 20 calendar years (1982–2016)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it493 - Regulatory (Subpart C or D), Gross Ton
335 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB3188MMSI 366884350 · cancelled · compulsorily equipped · granted 8 March 2003, cancelled 3 May 2004
WBJ2497MMSI 368370000 · cancelled · compulsorily equipped · granted 16 September 1998, cancelled 3 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 51

7 September 2016 Deficiency Check
Physical examination · Activities Europe · Activity 5994074
23 June 2005 Administrative Inspection
Administrative · Activities Europe · Activity 2399895
31 January 2005 Type not recorded
No type recorded · Activities Europe · Activity 2283423
19 February 2004 Administrative Inspection
Administrative · Activities Europe · Activity 2008942
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971028
2 September 2003 Deficiency Check
Physical examination · Activities Europe · Activity 1894176
21 February 2003 Annual Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 1742737
6 December 2001 Hull Examination · COI Inspection
Physical examination · Activities Europe · Activity 1475862
21 May 2001 Deficiency Check
Physical examination · Activities Europe · Activity 1063816
10 March 2001 COI Inspection
Physical examination · Activities Europe · Activity 1362056
19 February 2000 Re-Inspection
Physical examination · Activities Europe · Activity 1451525
28 June 1999 Deficiency Check
Physical examination · Activities Europe · Activity 1078771
14 May 1999 Hull Examination
Physical examination · Activities Europe · Activity 1365214
19 March 1999 COI Inspection
Physical examination · Activities Europe · Activity 811367
2 March 1998 Re-Inspection
Physical examination · Activities Europe · Activity 1120481
23 February 1997 Hull Examination
Physical examination · Activities Europe · Activity 1101651
16 January 1997 COI Inspection
Physical examination · Activities Europe · Activity 1099871
26 August 1996 Deficiency Check
Physical examination · Activities Europe · Activity 1085023
6 March 1996 Re-Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1357505
21 January 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1140707
30 November 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869690
4 August 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1178278
13 July 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1178140
1 June 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328805
26 April 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 858215
20 April 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 859826
5 April 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1167515
22 March 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854439
5 February 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165004
30 November 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 175694
29 November 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159015
9 June 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 833452
8 June 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1141915
6 April 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1144087
24 January 1993 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142198
14 February 1992 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955095
20 September 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248113
9 February 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913658
17 December 1990 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1233995
13 November 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1238121
7 March 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 908175
8 October 1989 Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220115
16 September 1989 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220584
29 August 1989 Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909791
15 February 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032369
15 February 1989 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036878
18 February 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1333567
4 November 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332661
22 June 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006019
14 February 1987 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312340
17 August 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968349

Deficiency record · 193

Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 14 May 2003 Resolved
1. Provide proper fully charged CO2 cylinders with valid hydro date for the bow thruster space inaccordance with approved plan. Maintain three additional BII extinguishers on board until completed. LEGACY COMPONENT DESC: Tanks
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 14 May 2004
Navigation › Collision/Grounding Avoidance
Issued 14 May 2003 Resolved
2. Compass deviation card not accurate. Update deviation card.
Action required: 705 - Other - as specified
Due 14 June 2003
Resolved 16 May 2003
Resolution: Received fax from vessel master stating that the compass deviation card was provided. VERIFY AT NEXT VISIT
Deck/Cargo › Mooring/Anchoring
Issued 14 May 2003 Resolved
3. Port anchor windlass clutch bracket broken. Make permanent repair to the bracket and prove proper operation. LEGACY COMPONENT DESC: Capstan
Condition: Improper/Lack of Maintenance
Due 14 June 2003
Resolved 16 May 2003
Resolution: Received fax from vessel master stating permanent repairs were made to the anchor windlass clutch bracket. VERIFY AT NEXT VISIT TO THE VESSEL.
Lifesaving › Rescue Boat › Construction
Issued 14 May 2003 Resolved
4. Provide workboat/rescue boat in compliance with MIO Europe Policy Letter dated February 7, 2002, vice soft bottom boat.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2003
Resolved 14 May 2004
Engineering › Pressure Vessel › Shell Plate
Issued 14 May 2003 Resolved
5. Forward stating air receiver wasted beyond repair inway of supports. Renew air receiver as original.
Condition: Improper/Lack of Maintenance
Due 14 August 2003
Resolved 14 May 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 14 May 2003 Resolved
6. Bracket securing CO2 cylinder broken for the paint locker CO2 system locker under wheel house port side stairs. Properly secure fixed CO2 cylinder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2003
Resolved 16 May 2003
Resolution: Received fax dated 16/05/03, from vessel master stating bottle was properly fixed to paint locker port side. VERIFY AT NEXT VISIT TO THE VESSEL.
Fire Fighting › Firemans Outfit
Issued 14 May 2003 Resolved
7. Provide 2 fully charged SCBA cylinders with valid hydro date. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Due 14 June 2003
Resolved 16 May 2003
Resolution: Received fax from vessel master stating SCBA bottles provided with valid hydro date. VERIFY AT NEXT VISIT TO THE VESSEL.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 14 May 2003 Resolved
8. Trouble shoot make permanent repair and prove proper operation of starboard main engine low lube oil shut down. LEGACY COMPONENT DESC: Governor
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 June 2003
Resolved 14 May 2004
Deck/Cargo › Holds/Tanks
Issued 21 February 2003 Resolved
Replace wasted starboard side liquid mud vent aft of fire station 3. LEGACY COMPONENT DESC: Ventilation Exhaust Outlet
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 25 March 2003
Resolution: Used temp repairs to install flame screen. Item to be replaced within 30 days.
Construction/Loadline › Structures
Issued 21 February 2003 Resolved
Crop and renew wastage/holed areas found throughout inboard side of port and starboard engine room escape hatches LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: cleared
Engineering › Diesel Engine (propulsion-direct drive)
Issued 21 February 2003 Resolved
Replace wasted and broken CO2 main engine ventilation shutdown on port side main deck aft of house LEGACY COMPONENT DESC: Piping (air intake)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 26 March 2003
Resolution: Vessel has installed the required portable extinguishers for all engineering spaces.
Fire Fighting › Structural Fire Protection - General
Issued 21 February 2003 Resolved
Remove hold back on engine room ventilation closure in port and starboard main deck deck locker. LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 25 March 2003
Resolution: Hold backs removed
Fire Fighting › Fire Main
Issued 21 February 2003 Resolved
Crop and renew piping in way of temporary welded repair found on fire main located aft of the forward engine room bulkhead LEGACY COMPONENT DESC: Condition
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2003
Resolved 14 May 2003
Resolution: Corrected
Accommodation/Occupational Safety › Ventilation › General
Issued 21 February 2003 Resolved
Crop and renew wastage/holed areas found throughout engine room ventilation duct
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2004
Resolved 14 May 2004
Electrical › Lighting (emergency)
Issued 21 February 2003 Resolved
Replace batteries for forward engine room centreline emergency light and aft steering gear compartment emergency light LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Completed
Pollution Prevention/Response › Prevention Equipment
Issued 21 February 2003 Resolved
Remove illegal by-pass hose and correctly pipe oily water separator LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Hose removed
Pollution Prevention/Response › Prevention Equipment
Issued 21 February 2003 Resolved
Prove proper operation of oily water separator LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: ABS completed IOPP Survey
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 21 February 2003 Resolved
Repair o-rings for y-coupling in port cargo tank discharge piping LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Renewed
Engineering › Fuel Oil Service System
Issued 21 February 2003 Resolved
Repair leaking fuel oil valve for port fuel oil tank discharge line LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Leak repaired
Engineering › Fuel Oil Service System
Issued 21 February 2003 Resolved
Repair fuel purifier fuel leaks LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Leak repaired
Engineering › Fuel Oil Storage/Transfer System
Issued 21 February 2003 Resolved
Repair fuel leak on starboard day tank fuel oil return line LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Leak repaired
Engineering › Fuel Oil Service System
Issued 21 February 2003 Resolved
Replace electrical control box for hydraulic oil pump near starboard side escape ladder LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Repaired
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 February 2003 Resolved
Repair emergency main engine shutdowns from bridge
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 26 March 2003
Resolution: inspectors witnessed proper operation of emergency main engine shutdowns
Engineering › Compressed Air System (control)
Issued 21 February 2003 Resolved
Repair or replace pressure relief valve on number 2 air compressor LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Renewed
Electrical › Electrical Distribution System (service)
Issued 21 February 2003 Resolved
Repair switchboard front cover latch LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Repaired
Electrical › Electric Generation Source (service)
Issued 21 February 2003 Resolved
Repair wires entering starboard generator junction box LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Repaired
Electrical › Electric Generation Source (service)
Issued 21 February 2003 Resolved
Repair or replace cover on port and starboard generator motors LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Covers replaced
Electrical › Electric Generation Source (service)
Issued 21 February 2003 Resolved
Repair shore tie breaker handle LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Handle repaired
Electrical › Electric Generation Source (service)
Issued 21 February 2003 Resolved
Repair and prove operation of reverse power relays LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 14 May 2003
Resolution: Tested satisfactory
Electrical › Electric Generation Source (service)
Issued 21 February 2003 Resolved
Repair overspeed shutdown actuation cable for number 2 generator LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 26 March 2003
Resolution: inspector witnessed proper operation of generator overspeed
Electrical › Electric Generation Source (service)
Issued 21 February 2003 Resolved
Repair lube oil leaks throughout number 2 generator LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Leaks repaired
Electrical › Electric Generation Source (service)
Issued 21 February 2003 Resolved
Repair lube oil leaks throughout lube transfer pump LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Leaks repaired
Engineering › Lubricating Oil Service System
Issued 21 February 2003 Resolved
Repair lube oil leaks on port main engine LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Leaks repaired
Engineering › Fuel Oil Service System
Issued 21 February 2003 Resolved
Remove jury-rig sight glass on port and starboard day tank LEGACY COMPONENT DESC: Tank
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 26 March 2003
Resolution: Sight glass removed, tank fittings plugged.
Engineering › Fuel Oil Service System
Issued 21 February 2003 Resolved
Properly install fuel oil low level alarm sensor on port and starboard day tank LEGACY COMPONENT DESC: Gauge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Low level alarm properly installed
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 21 February 2003 Resolved
Repair or replace and prove operation of pressure relief valves on all cargo P-tanks LEGACY COMPONENT DESC: Relief Valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2003
Resolved 14 May 2003
Resolution: Relief valves tested satisfactory
Documentation › Certificates/Documents
Issued 21 February 2003 Resolved
Provide onboard valid cargo ship safety radio certificate (ABS issued/expired December 2002) LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 21 February 2003 Resolved
Provide onboard valid license for chief mate
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 24 March 2003
Resolution: Cleared prior to departure by [name withheld].
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 February 2003 Resolved
Crop and renew wasted and holed bulkhead throughout main deck forward heads (approximately 3 inches up from deck)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2004
Resolved 14 May 2004
Lifesaving › Buoyant Smoke Signals
Issued 21 February 2003 Resolved
Replace expired bridge wing signal smoke devices
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 25 March 2003
Resolution: New smoke devices onboard ( it should be noted this item was required only for compliance with ABS requirements )
Electrical › Electric Supply System (service)
Issued 21 February 2003 Resolved
Replace all covers for emergency batteries aft of pilot house LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Covers replaced
Construction/Loadline › Structures
Issued 21 February 2003 Resolved
Repair wasted and holed deck inboard of port and starboard main stack LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Repaired
Accommodation/Occupational Safety › Ventilation
Issued 21 February 2003 Resolved
Seal joint for galley air conditioning unit ducting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Joint sealed
Construction/Loadline › Markings
Issued 21 February 2003 Resolved
Provide raised weld markings and repaint port and starboard side plimsoll, loadline and draft marks LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Load line and draft marks permanent.
Construction/Loadline › Structures
Issued 21 February 2003 Resolved
Replace closed cell foam for all water tight closures throughout vessel with proper rubber gaskets LEGACY COMPONENT DESC: Trunk
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Proper gaskets provided
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 February 2003 Resolved
Provide testing/inspection for entire fixed fire fighting systems by a competent servicing agent with USCG attendance LEGACY COMPONENT DESC: Quantity of CO2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 26 March 2003
Resolution: Vessel provided required portable extinguishers for engineering spaces.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 21 February 2003 Resolved
Service all portable extinguishers by a competent servicing agent and provide proper documentation of service report LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 25 March 2003
Resolution: new extinguishers provided
Construction/Loadline › Structures
Issued 21 February 2003 Resolved
Crop and renew wasted and holed overhead in port side main deck fan space/deck locker LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Completed
Accommodation/Occupational Safety › Ventilation
Issued 21 February 2003 Resolved
Install all mounting bolts for ventilation fan located in port side main deck fan space/deck locker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Bolts replaced
Engineering › Fuel Oil Service System
Issued 21 February 2003 Resolved
Remove all oil and grease from electrical control panel for air conditioning unit in port side main deck fan space/deck locker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Oil and grease removed
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 21 February 2003 Resolved
Replace wasted mud tank goose neck vent LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 7 September 2016
Resolution: Completed
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 February 2003 Resolved
Replace fixed fire fighting CO2 bracket for paint locker LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2004
Resolved 14 May 2003
Resolution: Reissued
Construction/Loadline › Structures
Issued 21 February 2003 Resolved
Repair watertight integrity for port and starboard main deck fan space/deck locker tonnage openings LEGACY COMPONENT DESC: Manhole
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Wasted area cropped and renewed
Electrical › Electric Supply System (service)
Issued 21 February 2003 Resolved
Replace all solid core wiring with proper marine grade stranded wire through the vessel LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Solid core wire replaced with stranded wire
Accommodation/Occupational Safety › Occupational Safety
Issued 21 February 2003 Resolved
Remove all wasted oxygen acetylene bottles
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 25 March 2003
Resolution: items removed
Accommodation/Occupational Safety › Occupational Safety
Issued 21 February 2003 Resolved
Remove excessive debris and oil/grease from engine room bilges
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 14 May 2003
Resolution: Corrected debris removed bilges cleaned
Lifesaving › Lifejacket/PFD (General)
Issued 21 February 2003 Resolved
Replace as required all batteries for lifejacket lights LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2003
Resolved 25 April 2003
Resolution: Batteries were replaced.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 21 February 2003 Resolved
Repair broken generator exaust bracket located over stbd MDE. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 14 May 2003
Resolved 14 May 2003
Resolution: Repaired
Engineering
Issued 21 February 2003 Resolved
Repair hole in overhead above stbd MDE. Wastage is IWO exaust support bracket.
Due 26 April 2003
Resolved 14 May 2003
Resolution: Repaired
Engineering
Issued 21 February 2003 Resolved
Completely clean and dry bilges for inspection, this condition shall be maintained for the duration of the inspection at which time the bilges will be examined for improper repairs and excessive wastage.
Due 26 April 2003
Resolved 14 May 2003
Resolution: Bilges cleaned
Navigation › Piloting/Steering
Issued 21 February 2003 Resolved
Remove posters and charts from the pilot house windows. Vessel must have 360 ' visibility with exception of stacks.
Due 26 April 2003
Resolved 14 May 2003
Resolution: Posters removed visiblity restored
Accommodation/Occupational Safety › Occupational Safety
Issued 21 February 2003 Resolved
Provide assist springs for the port engine room escape hatch.
Due 26 April 2003
Resolved 14 May 2003
Resolution: Cleared
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 February 2003 Resolved
Replace wasted CO2 cylinders for the bow thruster FF system. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Due 26 April 2003
Resolved 14 May 2003
Resolution: Cylinders removed
Operations/Management
Issued 21 February 2003 Resolved
Prepare the vessel for a periodic (expanded) inspection. Vessel must be taken to an agreeded upon facility, outside Nigeria within 30 days.
Due 26 April 2003
Resolved 14 May 2003
Resolution: inspection complete
Operations/Management › Drug and Alcohol Testing › CG Notification (positive results/refusals)
Issued 7 January 2002 Resolved
Submit proof of compliance with required Drug and Alcohol Testing Program in accordance with 46 CFR 16. LEGACY COMPONENT DESC: Testing, Random
Due 17 January 2002
Resolved 18 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 7 January 2002 Resolved
Hydrostatically test or replace all 100 lb CO2 cyclinders for engineroom fixed firefighting system. LEGACY COMPONENT DESC: Tanks
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 January 2002
Resolved 18 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Lifesaving › Launching Appliances › Winch
Issued 7 January 2002 Resolved
Replace winch assembly on rescue boat davit with assembly that will hold suitable length of wire rope for recue boat launching. LEGACY COMPONENT DESC: Winch
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 January 2002
Resolved 18 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Electrical › Electric Generation Source (service) › Generator
Issued 7 January 2002 Resolved
Repair and prove proper operation of required reverse power relay for vessels generators. LEGACY COMPONENT DESC: Reverse power relay
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2002
Resolved 18 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 7 January 2002 Resolved
Provide 30 X 30 mesh flame screens for all fuel oil gooseneck vents. LEGACY COMPONENT DESC: Flame screens
Condition: Improper/Lack of Maintenance
Due 17 January 2002
Resolved 18 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Documentation › Safety/Response Plans/Programs
Issued 7 January 2002 Resolved
Update Oil Transfer Procedures to include duties of each person by name or title IAW 33 CFR 155.720. LEGACY COMPONENT DESC: Oil Transfer Procedures
Action required: 705 - Other - as specified
Due 17 January 2002
Resolved 7 January 2002
Resolution: Received statement from Master stating that OTP had been updated to include required information.
Lifesaving › Inflatable Liferafts › Approval
Issued 7 January 2002 Resolved
Replace 20 man liferaft with CG approved 25 man liferaft. Vessel is not to carry more than 20 persons total until 25 person raft is properly installed on the vessel. LEGACY COMPONENT DESC: Capacity
Condition: Unknown
Due 17 January 2002
Resolved 18 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Lifesaving
Issued 10 March 2001 Resolved
Replace chemical life jacket lights with U.S. Coast Guard/SOLAS approved life jacket lights.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Fire Fighting
Issued 10 March 2001 Resolved
Have fixed fire fighting system serviced by an approved servicing company.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Unknown
Issued 19 February 2000 Resolved
Complete Worklist items issued to vessel Master on February 2000.
Condition: Unknown
Due 19 February 2000
Resolved 19 February 2000
Fire Fighting
Issued 14 May 1999 Resolved
HYDROTEST SCBA BOTTLES AT US DOT APPROVED FACILITY.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Fire Fighting
Issued 19 March 1999 Resolved
TEST FIXED FIRE SYSTEM TIME DELAY.
Condition: Unknown
Due 11 May 1999
Resolved 17 May 1999
Unknown
Issued 16 January 1997 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR IN ALL MODES.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Accommodation/Occupational Safety
Issued 6 March 1996 Resolved
PROVIDE WASTE MANAGEMENT PLAN IAW 33 CFR 151.57 FOR GALLEY.
Condition: Unknown
Due 14 April 1996
Resolved 28 May 1996
Construction/Loadline
Issued 6 March 1996 Resolved
PROVE VESSEL CAN RETAIN ALL OILY RESIDUES ABOARD IAW 33 CFR 155.360(b).
Condition: Unknown
Due 11 March 1996
Resolved 19 March 1996
Documentation
Issued 6 March 1996 Resolved
PROVIDE ON BOARD VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY IAW 33 CFR 130.3 PRIOR TO ENTERING U.S. WATERS.
Condition: Unknown
Due 6 March 1996
Resolved 19 March 1996
Fire Fighting
Issued 6 March 1996 Resolved
PROVE PROPER OPERATION OF FIXED CO2 SYSTEM FOR ENGINE AND BOW THRUSTER ROOMS; SPECIFICALLY, HAVE QUALIFIED SERVICING COMPANY TEST TIME DELAY MECHANISM, VERIFY TARE WEIGHT OF (2) 75 LB. CYLINDERS FOR BOW THRUSTER ROOM, FLEX LOOPS PRESSURIZED AND HAVE SYSTEM DISCHARGE CONTROLS TESTED.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Fire Fighting
Issued 6 March 1996 Resolved
PROVE PROPER OPERATION OF ENGINE ROOM VENTILATION REMOTE SHUTDOWN LOCATED ON AFT CARGO DECK PORT SIDE.
Condition: Unknown
Due 6 May 1996
Resolved 28 May 1996
Fire Fighting
Issued 6 March 1996 Resolved
PROPERLY SERVICE OR REPLACE SEMI-PORTABLE FIRE EXTINGUISHER IN ENGINE ROOM;WEIGH CYLINDER AND REPLACE HOSE REEL AND HORN.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Documentation
Issued 6 March 1996 Resolved
PROVIDE VALID FCC RADIOTELEPHONY CERTIFICATE IAW SOLAS Ch. IV Reg. 4.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Deck/Cargo
Issued 6 March 1996 Resolved
PROVIDE STANDARD DISCHARGE CONNECTION TO DISCHARGE SLOPS ASHORE IAW 33 CFR 155.360(c) and 155.430 and Reg. 19 of MARPOL 73/78.
Condition: Unknown
Due 12 March 1996
Resolved 19 March 1996
Accommodation/Occupational Safety
Issued 6 March 1996 Resolved
PROVIDE ON BOARD AND PROVE PROPER OPERATION OF MARINE SANITATION DEVICE IAW33 CFR 159.79(b)(1) PRIOR TO ENTERING U.S. WATERS.
Condition: Unknown
Due 6 March 1996
Resolved 19 March 1996
Electrical
Issued 6 March 1996 Resolved
PROVE PROPER OPERATION OF LUBE OIL TEMPERATURE SENSORS ON PORT AND STBD. SHIP SERVICE GENERATORS.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Lifesaving
Issued 6 March 1996 Resolved
PROVIDE RETRO-REFLECTIVE TAPE TO (4) RING BUOYS LOCATED ON STERN AND BRIDGEWINGS; RENEW PERIPHERY LINES AS NEC.
Condition: Unknown
Due 6 March 1996
Resolved 19 March 1996
Lifesaving
Issued 6 March 1996 Resolved
PROVIDE CHARGES FOR LINE THROWING GUN; EXPIRED MAR '94.
Condition: Unknown
Due 14 May 1996
Resolved 28 May 1996
Fire Fighting
Issued 6 March 1996 Resolved
PROVIDE SPARE CHARGE FOR SCBA BOTTLE; PRESENTLY HAS LESS THAN 30 MINS AIR.
Condition: Unknown
Due 6 April 1996
Resolved 19 March 1996
Construction/Loadline
Issued 6 March 1996 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR IAW 33 CFR 151.10.
Condition: Unknown
Due 14 May 1996
Resolved 28 May 1996
Lifesaving
Issued 6 March 1996 Resolved
PROVIDE (15) TYPE I PFD'S IAW WITH VESSEL'S COI; VESSEL IS RESTRICTED TO (12) PERSONS TOTAL UNTIL PROVIDED.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Fire Fighting
Issued 4 August 1994 Resolved
UPON REPLACEMENT OF CO2 BOTTLES FOR FIXED FIRE FIGHTING SYSTEM (ENGINEROOM)PROVIDE SERVICING REPORT FROM COMPANY COMPLETING INSTALLATION.
Condition: Unknown
Due 4 August 1994
Resolved 4 August 1994
Deck/Cargo
Issued 4 August 1994 Resolved
REPLACE SWIVEL SHOTS ON BOTH ANCHORS AND PEAN LINK AND SHACKLE ON PORT ANCHOR.
Condition: Unknown
Due 6 November 1994
Resolved 6 November 1994
Construction/Loadline
Issued 5 February 1994 Resolved
MAKE PERMANENT REPAIRS IN WAY OF DAMAGE TO #4 PORT BALLAST TANK (FORWARD BAY) AT DRYDOCK NLT 30JUN94.
Condition: Unknown
Due 5 February 1994
Resolved 5 February 1994
Fire Fighting
Issued 5 February 1994 Resolved
PILOT HOUSE/RADIO 1 EA CII CORRIDOR: 2 EA AII GALLEY: 1 EA BII AUXILLARY SPACE (BOW PROP): I ER BII MACHINERY SPACE: 5 EA BII PROVIDE SPARE PORTABLEFOR EACH SIZE AND VARIETY ONBOARD. THE ABOVE (2) REQUIREMENTS SHALL BE COMPLETED TO THE SATISFACTION OF INSPECTION OFFICE ([name withheld]).
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Fire Fighting
Issued 5 February 1994 Resolved
UPDATE SHIP'S FIRE AND SAFETY PLAN TO REFLECT CHANGES IN ON-BOARD FIRE- FIGHTING EQUIPMENT.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Lifesaving
Issued 5 February 1994 Resolved
HAVE BOTH INFLATABLE LIFERAFTS SERVICED (ANNUAL) AT AN APPROVED LIFERAFT SERVICING FACILITY, NO LATER THAN 16MAR94. IF THIS ITEM IS CLEARED VIA MAIL/FAX, PROVIDE A COPY OF SERVICING REPORT.
Condition: Unknown
Due 5 February 1994
Resolved 5 February 1994
Construction/Loadline
Issued 5 February 1994 Resolved
REPAIR AS ORIGINAL, TEMPORARY SCHEDULE 40 PIPING SECTIONS IN WAY OF E/R FIRE MAIN PUMP DISCHAGRE FLANGE, BILGE PUMP DISCHARGE FLANGE, FIRE MAIN FORWARD ALLEY AND HYDRO TEST TO 150 PSI AT DRYDOCK NLT 30JUN94.
Condition: Unknown
Due 5 February 1994
Resolved 5 February 1994
Lifesaving
Issued 5 February 1994 Resolved
PROVIDE CG APPROVED LIGHTS FOR THE (5) ADULT PFD'S PRESENTLY NOT EQUIPPED. VESSEL PRESENTLY HAS 22 PFD'S WITH LIGHTS AND 5 WITHOUT, AND THEREFORE, THEVESSEL SHALL BE LIMITED TO CARRYING NO MORE THAN 22 PERSONS UNTIL REMAININGLIGHTS ARE PROVIDED.
Condition: Unknown
Due 5 February 1994
Resolved 5 February 1994
Fire Fighting
Issued 5 February 1994 Resolved
PROVE PROPER OPERATIONS OF FIRE DETECTOR IN BOW PROP SPACE.
Condition: Unknown
Due 5 February 1994
Resolved 5 February 1994
Construction/Loadline
Issued 5 February 1994 Resolved
MAKE TEMPORARY REPAIRS IN WAY OF DAMAGE TO #4 PORT FUEL DRY TANK IAW REPAIRPROPOSAL DTD 3FEB94 TO SATISFACTION OF ATTENDING ABS SURVEYOR AND PROVIDE REPORT. PROVIDE PORTABLE FIRE EXTINQUISHERS OF PROPER SIZE AND TYPE.
Condition: Unknown
Due 28 February 1994
Resolved 14 March 1994
Fire Fighting
Issued 5 February 1994 Resolved
HAVE ALL CO2, BOTTLES ON ENGINEROOM FIXED CO2 FIRE EXTINGUISHING SYSTEM HYDRO-TESTED BY A U.S. DOT APPROVED FACILITY. FURTHERMORE, HAVE FIXED CO2 SYSTEM FOR ENGINEROOM AND BOW PROP SPACE SERVICED AND TESTED IN THE PRESENCE OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Electrical
Issued 5 February 1994 Resolved
PROVE PROPER OPERATION OF STARBOARD SHIP SERVICE GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Engineering
Issued 5 February 1994 Resolved
MAKE PERMANENT REPAIRS IN WAY OF DAMAGE TO #4 PORT FUEL DRY TANK AT DRYDOCKNLT 30JUN94.
Condition: Unknown
Due 5 February 1994
Resolved 5 February 1994
Electrical
Issued 5 February 1994 Resolved
PROVE PROPER OPERATION OF CONTROL MOTOR (AUTO VOLTAGE CONTROL) FOR PORT SHIP SERVICE GENERATOR GOVERNOR.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Electrical
Issued 5 February 1994 Resolved
REPAIR FAULTY INDICATOR LIGHT FIXTURE FOR STARBOARD GENERATOR BREAKER "CLOSE" INDICATOR ON MAIN SWITCH BOARD.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Construction/Loadline
Issued 5 February 1994 Resolved
MAKE PERMNENT REPAIRS TO AIR BLOW OUT LINE TO PORT ENGINE ROOM SEA CHEST ATDRYDOCK NLT 30JUN94.
Condition: Unknown
Due 5 February 1994
Resolved 5 February 1994
Engineering
Issued 5 February 1994 Resolved
RENEW ALL MISSING AND BROKEN GAUGES ON LOCAL DISPLAY PANELS FOR PORT AND STARBOARD MAIN ENGINES.
Condition: Unknown
Due 5 February 1994
Resolved 5 February 1994
Engineering
Issued 24 January 1993 Resolved
PROVIDE OPERATING MANUAL AND PROVE PROPER OPERATION OF OILY WATER SEPARATORPRIOR TO ENTERNING U.S. WATERS.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Fire Fighting
Issued 24 January 1993 Resolved
REPLACE FIRE PUMP PRESSURE GAUGE ON BRIDGE.
Condition: Unknown
Due 24 January 1993
Resolved 24 January 1993
Engineering
Issued 24 January 1993 Resolved
PROVE PROPER OPERATION OF BOTH MAIN DIESEL ENGINE LUBE OIL SHUTDOWNS, IN CONJUNCTION WITH REMOTE BRIDGE SHUTDOWNS.
Condition: Unknown
Due 23 March 1993
Resolved 24 May 1993
Lifesaving
Issued 24 January 1993 Resolved
PROVE PROPER OPERATION OF THE ENGINE ROOM GENERAL ALARM AND LIGHT.
Condition: Unknown
Due 17 March 1993
Resolved 17 March 1993
Fire Fighting
Issued 24 January 1993 Resolved
REPLACE FIRE DETECTION SENSOR IN THE BOW THRUSTER SPACE.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Electrical
Issued 24 January 1993 Resolved
REPAIR TWO (02) FLOOD LIGHTS FOR MAIN DECK MOUNTED ON STACKS.
Condition: Unknown
Due 24 March 1993
Resolved 24 May 1993
Engineering
Issued 24 January 1993 Resolved
INCREASE STBD MAIN DIESEL ENGINE OVER SPEED TRIP IN ACCORDANCE WITH ABS RULES.
Condition: Unknown
Due 17 March 1993
Resolved 17 March 1993
Electrical
Issued 24 January 1993 Resolved
INSTALL LAMPS IN THE ENGINE ROOM ELECTRICAL SWITCHBOARD.
Condition: Unknown
Due 17 March 1993
Resolved 17 March 1993
Accommodation/Occupational Safety
Issued 24 January 1993 Resolved
REPLACE FAN MOTOR LOCATED IN GALLEY ABOVE STOVE.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Electrical
Issued 24 January 1993 Resolved
PROVE PROPER OPERATION OF THE #2 SHIP SERVICE DIESEL GENERATOR SPEED CONTROLLER ON THE ENGINE ROOM SWITCHBOARD. ALL REQUIREMENTS E-1 THRU E-16 ARE TO BE SATISFACTORILY COMPLETE. FAX RESULTS TO [name withheld] FAX [phone withheld].
Condition: Unknown
Due 17 March 1993
Resolved 17 March 1993
Lifesaving
Issued 24 January 1993 Resolved
HYDRO AND SERVICE ONE (01) SPARE AIR BOTTLE FOR SELF-CONTAINED BREATHING APPARATUS.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Engineering
Issued 24 January 1993 Resolved
INSTALL PROPER SIZE CG APPROVED RELIEF VALVE ON E/R AIR RECEIVER #216826 AND PROVE PROPER OPERATION (OUTBOARD).
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Construction/Loadline
Issued 24 January 1993 Resolved
PERMANENTLY REPAIR WASTED PT-4 FILL BALLAST PIPING IN E/R.
Condition: Unknown
Due 24 January 1993
Resolved 24 January 1993
Electrical
Issued 24 January 1993 Resolved
REPLACE BENCH GRINDER ELECTRICAL CORD IN E/R WITH APPROVED UL CORD/MARINE CORD.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Deck/Cargo
Issued 24 January 1993 Resolved
INSTALL PROPER SIZE CG APPROVED RELIEF VALVES ON ALL FOUR (4) BULK TANKS AND PROVE PROPER OPERATION.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Engineering
Issued 24 January 1993 Resolved
REPAIR/PROVE PROPER OPERATION OF STBD MAIN DIESEL ENGINE GOVERNOR.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Documentation
Issued 24 January 1993 Resolved
PROVIDE AND POST, OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 17 March 1993
Resolved 17 March 1993
Engineering
Issued 24 January 1993 Resolved
INSTALL SCREENS ON VENTILATION DUCTING IN ENGINE ROOM.
Condition: Unknown
Due 17 March 1993
Resolved 17 March 1993
Electrical
Issued 24 January 1993 Resolved
REPAIR ELECTRICAL CABLE AND CONNECTION BOX ON THE PORT REDUCTION GEAR COOLING PUMP.
Condition: Unknown
Due 17 March 1993
Resolved 17 March 1993
Fire Fighting
Issued 24 January 1993 Resolved
SERVICE BV EXTINGUISHER IN ENGINE ROOM (HOSE AND REEL).
Condition: Unknown
Due 17 March 1993
Resolved 17 March 1993
Fire Fighting
Issued 14 February 1992 Resolved
HAVE (2) TWO 75LB CO2 BOTTLES FOR BOW THRUSTER ROOM HYDROSTATICALLY TESTED AT DOT APPROVED FACILITY. TO BE ACCOMPLISHED NOT LATER THAN APRIL 1ST, 1992.
Condition: Unknown
Due 14 February 1992
Resolved 14 February 1992
Engineering
Issued 14 February 1992 Resolved
HAVE PORT AND STARBOARD MAIN ENGINES TESTED FOR OVERSPEED TRIPS LOW LUBE OIL TRIP, AND HIGH WATER JACKET TEMPERATURE ALARMS BY ABS, MASTER AND CHIEFENGINEER, TO BE ACCOMPLISHED PRIOR TO VESSEL LEAVING WALVIS BAY, R.S.A.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Electrical
Issued 14 February 1992 Resolved
HAVE PORT AND STARBOARD SHIPS SERVICE GENERATORS TESTED FOR OVERSPEED TRIPS, LOW LUBE OIL TRIPS, AND HIGH TEMPERATURE WATER JACKET ALARM, ALSO TEST REVERSE POWER RELAYS BY ABS, MASTER AND CHIEF ENGINEER, TO BE ACCOMPLISHED PRIOR TO VESSEL LEAVING WALVIS BAY, R.S.A.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Navigation
Issued 14 February 1992 Resolved
PROVE PROPER OPERATION OF LOSS OF POWER ALARMS FOR PORT AND STARBOARD STEERING PUMPS, TO BE ACCOMPLISHED NOT LATER THAN MARCH 31, 1992.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Construction/Loadline
Issued 14 February 1992 Resolved
PROVE PROPER OPERATION OF OILY BILGE DISCHARGE MONITOR AS PER IOPP CERTIFICATE. TO BE ACCOMPLISHED NOT LATER THAN 31 MARCH 1992.
Condition: Unknown
Due 14 February 1992
Resolved 14 February 1992
Navigation
Issued 9 February 1991 Resolved
PROVE PROPER OPERATION OF RUDDER ANGLE INDICATOR USING NUMBER TWO PUMP FOLLOW-MODE.
Condition: Unknown
Due 9 February 1991
Resolved 9 February 1991
Documentation
Issued 9 February 1991 Resolved
PROVIDE CURRENT COPY OF RULES OF THE ROAD.
Condition: Unknown
Due 9 February 1991
Resolved 9 February 1991
Unknown
Issued 9 February 1991 Resolved
CONDUCT MAIN OVERBOARD/RESUCE BOAT DRIVE.
Condition: Unknown
Due 9 February 1991
Resolved 9 February 1991
Construction/Loadline
Issued 17 December 1990 Resolved
VESSEL RESTRICTED FROM OPERATION UNTIL APPROVED PROOF REPAIRS TO BOW PORT_x001C_ SIDE (AS PER DAMAGE SURVEY THIS DATE) THIS REQUIREMENT TO BE COMPLETED TO _x001C_SATISFACTION OF COGNIZANT [name withheld].
Condition: Unknown
Due 17 December 1990
Resolved 17 December 1990
Fire Fighting
Issued 29 August 1989 Resolved
REPLACE MODIFIED DISCHARGE HEAD ASSEMBLY ON FIXED CO2 SYSTEM FOR BOW THRUSTER COMPARTMENT WITH THE PART RECOMMENDED BY THE MANUFACTURER AS SHOWNON THE ORIGINAL INSTALLATION DRAWINGS.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Lifesaving
Issued 29 August 1989 Resolved
REPLACE DAMAGED RAFTS PORT AND STARBOARD AND INSTALL WITH PROPERLY TESTED HYDROSTATIC RELEASES PRIOR TO VESSELS GETTING UNDERWAY.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Engineering
Issued 15 February 1989 Resolved
REPAIR THE EMERGENCY SHUTDOWN FROM THE BRIDGE FOR THE PORT ENGINE.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Documentation
Issued 15 February 1989 Resolved
THE MASTER SHALL IMMEDIATELY CARRY OUT ALL ACTIONS AND OBSERVATIONS LISTED IN 46 CFR 97. AND THEN AGAIN AS OFTEN AS REQUIRED. THESE ACTIONS AND OBSERVATIONS SHALL THEN BE LOGGED. SEE THE DETAILED DESCRIPTION OF EACH ACTION AND OBSERVATION FOR WHAT MUST BE INCLUDED IN THE LOG BOOK ENTRY.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Deck/Cargo
Issued 15 February 1989 Resolved
RENEW THE WASTED STRUCTURAL SCREEN AND METAL BALL TO THE BELL PAINTED BLACKON THE AIR PIPE AT THE AFTER PORT CORNER OF THE STERN. 46 CFR 42.15-50
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Construction/Loadline
Issued 15 February 1989 Resolved
REPLACE CRACKED AND DENTED FLOAT BALL IN THE STARBOARD AFT WATER VENT AIR PIPE BELL. 46 CFR 42.15-50
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Fire Fighting
Issued 15 February 1989 Resolved
REPAIR THE PULL CABLE FROM ON DECK TO THE BOW THRUSTER CO2 46CFR 97.15-60 (B).
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Fire Fighting
Issued 15 February 1989 Resolved
POST INSTRUCTIONS IN THE TUNNEL, NEAR THE CO2 BOTTLES FOR THE PROPER OPERATION OF THE FIXED CO2 SYSTEM TO BOTH THE BOW THRUSTER COMPARTMENT AND THE ENGINE ROOM. 46 CFR 95.15-10(H).
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Deck/Cargo
Issued 15 February 1989 Resolved
REPLACE CRACKED BALL AND WASTED FLAME AND STRUCTURAL SCREENS ON AFTERMOST PORT LIQUID MUD TANK VENT. 46CFR 42.15-50
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Electrical
Issued 15 February 1989 Resolved
REPLACE ALL BURNED-OUT BULBS TO THE ALARM INDICATING PANELS ON THE BRIDGE AND IN THE ENGINE ROOM.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Unknown
Issued 15 February 1989 Resolved
FOR THE NO.1 & 2 GENERATORS MAKE OPERABLE THE AUDIBLE AND VISUAL ALARM TO INDICATE ABNORMAL OPERATION OF THE LUBE OIL LOW PRESSURE, AND HIGH TEMPERATURE AND JACKET WATER-HIGH TEMPERATURE.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Engineering
Issued 15 February 1989 Resolved
FOR THE STARBOARD MAIN ENGINE MAKE OPERABLE INSTRUMENTS TO MONITOR(VISUAL DISPLAY)& ALARMS(AUDIBLE & VISUAL)TO INDICATE ABNORMAL OPERATION WITHIN THEFOLLOWING SYSTEMS:JACKET WATER TEMP:CONT DISPLAY ALARM-HIGH LUBE OIL PRESS:CONT DISPLAY ALARM-LOW LUBE OIL TEMP CONT DISPLAY ALARM-HIGH.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Lifesaving
Issued 15 February 1989 Resolved
PROVIDE A NEW PORTABLE GASOLINE FUEL TANK FOR THE RESCUE BOAT.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Lifesaving
Issued 15 February 1989 Resolved
REPLACE THE MISSING STARBOARD ROW LOCK ON THE RESCUE BOAT (ZODIAC). UNTIL THIS ITEM IS CORRECTED THE BOAT MUST ALWAYS BE LAUNCHED WITH THE OUTBOARD MOTOR INSTALLED. 46 CFR 97.15-45(A)(G).
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Electrical
Issued 15 February 1989 Resolved
OBTAIN U.L. APPROVED MARINE-TYPE LIGHT FIXTURE TO REPLACE THE BROKEN FIXTURE IN UPPER FORWARD BUNK IN 2ND ENGINEER STATEROOM.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Electrical
Issued 15 February 1989 Resolved
OBTAIN U.L. APPROVED MARINE-TYPE LIGHT FIXTURES AND INSTALL WHERE MISSING IN 2 AFT BUNKS IN 2ND ENGINEER STATEROOM.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Lifesaving
Issued 15 February 1989 Resolved
OBTAIN AUX LINE FOR LINE THROWING GUN THAT IS EITHER;1)MANILA & IS AT LEAST500FT LONG & 3 INCHES IN CIRCUMFERENCE(OR MORE)OR 2)A SYNTHETIC MATERIAL & IS AT LEAST 500FT LONG WITH A CERTIFIED BREAKING STRENGTH OF AT LEAST 9000 LBS & IS RESISTANT TO EFFECTS OF ULTRAVIOLET LIGHT.46CFR 94.45-15(H)(B)(I)
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Lifesaving
Issued 15 February 1989 Resolved
PROVIDE NEW OR PROPERLY SERVICED HYDROSTATIC RELEASES FOR THE TWO INFLATABLE LIFE RAFTS AND INSTALL PROPERLY PER MANUFACTURES INSTRUCTIONS. 46 CFR 160.062-4(F)(2)
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Lifesaving
Issued 15 February 1989 Resolved
PROVIDE A CLASS "A" EPIRB. VESSEL RESTRICTED TO 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL EPIRB IS ABOARD
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Navigation
Issued 15 February 1989 Resolved
AT THE BRIDGE STEERING GEAR PANEL, REPLACE THE BURNED OUT BULBS FOR THE "POWER" LIGHT FOR NO. 1 PUMP AND THE "RUN" LIGHT FOR THE NO.2 PUMP. 46 CFR 111.93-13(D)
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Electrical
Issued 15 February 1989 Resolved
REPAIR THE BELL TO THE SOUND POWERED PHONE IN THE [name withheld].
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Fire Fighting
Issued 15 February 1989 Resolved
REPAIR THE INOPERATIVE PRESSURE GUAGE ON THE DISCHARGE SIDE OF THE FIRE PUMP.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Electrical
Issued 15 February 1989 Resolved
OBTAIN PROPER COVER FOR LOWER OUTBOARD BUNK LIGHT IN AFT MAIN-DECK CREWS QUARTERS.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Lifesaving
Issued 15 February 1989 Resolved
REPLACE OR REPAIR LIFE PRESERVER WITH STAINED/DEGRADED RETRO-REFLECTIVE PATCHES.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Electrical
Issued 15 February 1989 Resolved
OBTAIN AND INSTALL GLOBE AND GUARD FOR LIGHT FIXTURE ON FORWARD BULKHEAD INOFFICER'S LOUNGE.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Electrical
Issued 15 February 1989 Resolved
REPLACE OR REPAIR AS NECESSARY: BOTH AFT BOTH FORWARD, AND UPPER OUTBOARD BUNK LIGHTS IN AFT MAIN-DECK CREW QUARTERS.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Fire Fighting
Issued 15 February 1989 Resolved
REPAIR THE INOPERATIVE FIRE MAIN PRESSURE GAUGE ON THE BRIDGE.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Documentation
Issued 15 February 1989 Resolved
OBTAIN A VALID CARGO SHIP SAFETY RADIOTELEPHONY CERTIFICATE (CH 1 SOLAS REGULATION 12(A) (V) AND 14(C) OF THE INTERNATIONAL CONVENTION FOR THE SAFETY OF LIFE AT SEA).THIS CERTIFICATE MUST BE OBTAINED IMMEDIATELY.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Lifesaving
Issued 15 February 1989 Resolved
REPLACE OR REPAIR LIFE PRESERVER WITH SEVERED WAIST DRAWSTRING.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Engineering
Issued 15 February 1989 Resolved
MAKE PERMANENT REPAIRS TO THE HOLED PIPE IN THE DISCHARGE SIDE OF THE BILGEPUMP. JUST ABOVE THE FIRST JOINT.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Electrical
Issued 15 February 1989 Resolved
REPAIR THE GENERAL ALARM BELL IN THE BOW THRUSTER ROOM.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Engineering
Issued 15 February 1989 Resolved
FOR THE ATHWARTSHIPS AIR RECEIVER IN THE ENGINE ROOM, PROVIDE A PRESSURE GUAGE WITH AN UPPER RANGE OF 240 PSI TO 400PSI . 46 CFR 54.15-5(F)
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Engineering
Issued 15 February 1989 Resolved
MAKE A TEMPORARY REPAIR TO STOP THE LEAK DESCRIBED IN E12.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Fire Fighting
Issued 15 February 1989 Resolved
OBTAIN AND INSTALL MANUFACTURERS RECOMMENDED BRACKET TO REPLACE THE BROKEN FIRE EXTINGUISHER BRACKET ON THE STARBOARD SIDE OF THE ENGINE ROOM.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Fire Fighting
Issued 15 February 1989 Resolved
SAND AND PAINT AS NECESSARY TO HALT CORROSION OF THE 5 PORTABLE DRY CHEMICAL FIRE EXTINGUISHERS IN THE ENGINE ROOM AND BOW THRUSTER COMPARTMENT
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Engineering
Issued 15 February 1989 Resolved
REPAIR THE PORT SHAFT TACHOMETER INDICATOR ON THE BRIDGE AT THE FORWARD CONSOLE.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Navigation
Issued 15 February 1989 Resolved
REPAIR THE RUDDER INDICATING DEVICE WHEN IN FOLLOW-UP ON THE NO. 2 PUMP.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Deck/Cargo
Issued 15 February 1989 Resolved
REPLACE WASTED FLAME AND STRUCTURAL SCREENS IN THE FORWARD-MOST LIQUID MUD-TANK VENT OF THE GROUP OF FOUR LOCATED AFT OF THE PORT DRY-CEMENT PUMPING STATION. 46 CFR 56.50-85(A)
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Engineering
Issued 15 February 1989 Resolved
REPLACE WASTED STRUCTURAL SCREEN ON STARBOARD FUEL-TANK VENT LOCATED IMMEDIATELY AFT OF STARBOARD DRY-CEMENT PUMPING STATION.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Deck/Cargo
Issued 15 February 1989 Resolved
INSTALL FLAME SCREEN ON AFTERMOST STARBOARD MUD TANK VENT. 46 CFR 56.50-85 (A)
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Deck/Cargo
Issued 15 February 1989 Resolved
REPLACE WASTED STRUCTURAL SCREENS IN STARBOARD LIQUID MUD TANK VENTS IN THEGROUP OF FOUR, LOCATED AFT OF THE DRY-CEMENT PUMPING STATION NUMBERS 1 & 3 AS COUNTED FROM THE STERN.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Construction/Loadline
Issued 15 February 1989 Resolved
REPLACE WASTED STRUCTURAL SCREEN IN STARBOARD AFT FUEL VENT BELL.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Deck/Cargo
Issued 15 February 1989 Resolved
RENEW WASTED FLAME SCREEN TO THE FUEL OIL DAY TANK VENT ON THE STARBOARD SIDE OF THE 0-1 DECK, AFT OF THE HOUSE. 46 CFR 56.50-85(A)
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Construction/Loadline
Issued 15 February 1989 Resolved
REPLACE WASTED STRUCTURAL SCREEN IN FORWARD MOST STARBOARD HYDRAULIC VENT.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Electrical
Issued 15 February 1989 Resolved
REPLACE BURNED OUT LIGHT IN UPPER FORWARD BUNK IN COOK'S STATEROOM.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Lifesaving
Issued 15 February 1989 Resolved
MARK WITH SHIP'S NAME AND OBTAIN USCG APPROVED LIGHTS FOR THE THREE REJECTED LIFE PRESERVERS.
Condition: Unknown
Due 15 February 1989
Resolved 15 February 1989
Navigation
Issued 18 February 1988 Resolved
PROVE PROPER OPERATION OF STEERING IN AUTO PILOT MODE.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Lifesaving
Issued 18 February 1988 Resolved
HYDRO STATICALLY TEST THE TWO (2) HYDRO RELEASE FOR LIFERAFTS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Navigation
Issued 18 February 1988 Resolved
REPAIR RUDDER ANGLE INDICATOR LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Engineering
Issued 18 February 1988 Resolved
PROVIDE NEW RELIEF VALVES FOR #1 AND #2 STARTING AIR RECIEVERS AND COMPRESSORS INCLUDING VALVES OF PROPER SETTING AND HAND RELIEVING GEAR.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Electrical
Issued 18 February 1988 Resolved
REPAIR AND PROVE PROPER OPERATION OF #1 AND #2 SHIP SERVICE GENERATORS OVERSPEED TRIPS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Lifesaving
Issued 18 February 1988 Resolved
PROVIDE PROPER LIGHTS AND WHISTLES FOR LIFE JACKETS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Fire Fighting
Issued 18 February 1988 Resolved
SERVICE VESSEL'S FIXED CO2 SYSTEM FOR ENGINE ROOM. UPON COMPLETION OF SERVICING NOTIFY THIS OFFICE BY TELEX.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Lifesaving
Issued 14 February 1987 Resolved
PERFORM ANNUAL SERVICING ON LIFERAFT (15 MAN LOT #50 SN #SPCMM5) AT APPROVED SERVICING FACILITY IN PRESCENCE OF USCG INSPECTOR OR REPLACE WITH USCG APPROVED 15 MAN LIFERAFT WITH UP TO DATE SERVICING.
Condition: Unknown
Due 14 February 1987
Resolved 14 February 1987
Fire Fighting
Issued 14 February 1987 Resolved
NOTIFY MIO NY (TELEX 6720572) UPON COMPLETION OF RESCUE BOAT REPAIRS AND INSTALLATION OF FIRE DAMPERS ON PORT AND STARBOARD STACKS.
Condition: Unknown
Due 14 February 1987
Resolved 14 February 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.