This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it3823 - Convention (Subpart B), Gross Ton 3028 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 29
8 March 1999Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 801132
10 May 1996Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085343
19 April 1995Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 854700
28 April 1994Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 856979
25 April 1994Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438156
6 April 1993COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1382551
16 September 1992Initial Construction-Excluding Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245310
25 May 1992Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 156392
24 March 1992Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254565
19 March 1992Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316578
5 June 1991Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1202400
1 May 1991Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904025
24 April 1991Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 928700
20 March 1991COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927658
10 October 1990Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 913880
26 October 1989Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1206246
8 July 1989Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1038145
2 March 1989Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199965
2 March 1989MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344150
4 April 1988Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993831
2 February 1988Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019362
29 June 1987Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016813
21 February 1987COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003323
30 September 1986Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006984
24 July 1986COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989444
24 January 1985Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 528863
17 August 1984Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282261
12 July 1984Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280371
24 June 1982Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279193
PRIOR TO OPERATING HYD SYSTEM REPLACE HOSES AND FITTINGS ON _x001C_ #1 HATCH FWD STBD SIDE, #1 HATCH FWD PORT SIDE, HOSES ON STBD WILDCAT FWD. HOSES AND FITTING WASTED AND OR WORN THROUGH.
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Engineering
Issued 19 March 1992Resolved
REMOTE STOP WILL NOT SHUT DOWN ENGINE WHEN ACTIVATED, ENGINE KEEPS RUNNING.REPAIR SYSTEM SO ENGINE WILL SHUT DOWN WHEN REMOTE STOP ACTIVATED. (REPAIR PRIOR TO THE RUNNING OF THE ENGINE)
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Engineering
Issued 19 March 1992Resolved
REPLACE F/O LINES ON HYD. SYSTEM ENGINE. REPLACE WITH APPROVED FITTINGS AND HOSES. (PRIOR TO RUNNING ENGINE) RENEW ALL F/O LINES WITH THE "PUSH LOCK FITTINGS"
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Engineering
Issued 19 March 1992Resolved
REPLACE HYD. HOSES AND FITTINGS WITH APPROVED HOSES AND FITTINGS, ON THE ENGINES HYD. SYSTEM. REPLACE ALL THE "PUSH LOCK" FITTINGS. (COMPLETE PRIOR TO RUNNING ENGINE).
Condition: Unknown
Due 24 March 1992
Resolved 24 March 1992
Electrical
Issued 20 March 1991Resolved
REPLACE FLEXIBLE FUEL HOSE ON DIESEL RETURN LINE ON THE VESSEL'S GENERATOR DRIVE MOTOR PER 46 CFR 56.60-25(C).
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Construction/Loadline
Issued 20 March 1991Resolved
REPAINT VESSEL'S NAME ON P/S BOW.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Electrical
Issued 20 March 1991Resolved
REMOVE UNUSED ELECTRICAL LINES ON PORT DECK. (LINES ARE NO LONGER USED. THEY RUN FORE AND AFT, THE ENTIRE LENGTH OF VESSEL.)
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Deck/Cargo
Issued 20 March 1991Resolved
REPLACE MISSING HAND OPERATION LEVERS ON HYDRAULIC ACTUATION CONTROL UNIT ON CARGO HATCH COVERS #1, #2 AND #3.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Construction/Loadline
Issued 20 March 1991Resolved
REPAIR PERSONNEL LADDER ON PORT SIDE OF VESSEL. (NUMEROUS LADDER RUNGS ARE BROKEN/DAMAGED)
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Deck/Cargo
Issued 20 March 1991Resolved
REPAIR LEAKS ON HYDRAULIC MOTORS/COG ASSEMBLIES LOCATED FORWARD ON #1 CARGOHATCH COVER, STARBOARD (BOTH THE FORE AND AFT UNITS) AND REPAIR LEAK ON HYDRAULIC MOTOR FOR AFT MOORING WINCH. (ALL THREE UNITS LEAK EXCESSIVELY.)
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Deck/Cargo
Issued 20 March 1991Resolved
REMOVE UNUSED HYDRAULIC LINES THAT USE TO SERVICE THE FORWARD MOORING WINCH. (WINCH IS NO LONGER INSTALLED.)
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Electrical
Issued 10 October 1990Resolved
PROVIDE MISSING BULB AND GLASS GLOBE TO LIGHTING FIXTURE IN HYDRAULIC ROOM.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Electrical
Issued 10 October 1990Resolved
MAKE PERMANENT INSTALLATION OF CABLE TO SOLAR CHARGING PANEL FROM BATTERY BOX IN HYDRAULIC ROOM, PER 46 CFR 111.60.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Deck/Cargo
Issued 10 October 1990Resolved
PROPERLY STUFF CABLE PENETRATION BETWEEN HYDRAULIC ROOM AND GENERATOR ROOM.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Construction/Loadline
Issued 12 July 1984Resolved
DEMONSTRATE BY ULTRASONIC TESTING THAT WELD JOINTS OF INSERT IWO PORT SIDE SHELL IS SAT.
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Construction/Loadline
Issued 12 July 1984Resolved
CROP OUT AND INSERT IMPROPERLY INSTALLED INSERT IWO STBD SHELL AFT.
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Documentation
Issued 12 July 1984Resolved
OBTAIN AND PLACE ON BOARD A NEW STABILITY LETTER.
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Construction/Loadline
Issued 12 July 1984Resolved
PROVIDE COPIES OF APPROVED PLANS FOR ALL MODIFICATIONS TO DECKHOUSE AND MACHINERY.
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National