Records from 1985 to 1992. Most recent: inspection, 26 October 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
26 October 1992
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1252828
25 October 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 354011
21 May 1992
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1260934
7 October 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 346497
1 May 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1218650
14 February 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 341856
25 January 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 905022
5 December 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1231437
4 December 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 340939
13 June 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1238548
2 December 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916756
29 September 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 441577
2 February 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198055
16 January 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1200631
11 October 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 439309
9 April 1988
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1207700
8 September 1987
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 318293
5 June 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1028011
7 March 1987
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 499503
16 December 1986
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1023957
21 November 1986
Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1020252
29 October 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 312344
13 September 1986
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1000660
12 September 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 459086
19 June 1986
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 309683
8 October 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 305068
3 September 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 304035
16 July 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1289800
15 July 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 303533
20 March 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 472743
Deck/Cargo
Issued 21 May 1992
Resolved
properly mount main deck cargo heating lnes.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Lifesaving
Issued 21 May 1992
Resolved
PROVIDE SMOKE MARKER FOR PORT BRIDGE WING LIFEBOUY.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Electrical
Issued 5 December 1990
Resolved
ELECT. BOXES MAIN DECK WASTED STEEL AND OPEN TO WEATHER. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990
Resolved
GENERAL - MANY GOOSENECK VENTS ARE WASTED AND HOLED. TO BE COMPLETED PRIORTO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 5 December 1990
Resolved
STBD LIFEBOAT CRADLE WASTED. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Engineering
Issued 5 December 1990
Resolved
55 GAL. FUEL TANK FOR TEMP GENERATOR - NO VENT, NO SHUTOFF, NO CONTAINMENT.TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990
Resolved
MANY VENT CLOSURES FROZEN OPEN - CAN'T CLOSE. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 5 December 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Accommodation/Occupational Safety
Issued 5 December 1990
Resolved
PUMPROOM - GRATES, LADDERS AND HANDRAILS WASTED STEEL. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990
Resolved
TALLOW AND OTHER OILY SUBSTANCE IN PUMPROOM BILGES. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.PORT
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Construction/Loadline
Issued 5 December 1990
Resolved
AFT P/RM BHD - PORT - OPEN TO E/R AROUND A PIPE. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Documentation
Issued 5 December 1990
Resolved
OIL TRANSFER PROCEDURES DO NOT MEET 33 CFR 155.750A, SUBSECTIONS (1)(2)(3) (5)(6)(10). TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Engineering
Issued 5 December 1990
Resolved
GASOLINE ENGINE PUMP AND GASOLINE STOWED ON CARGO DECK. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Electrical
Issued 5 December 1990
Resolved
PUMPROOM LIGHTING IS NO LONGER EXPLOSION PROOF ( NO GLOBES, SCREWS MISSING)ALSO SWITCH AT TOP OF LADDER IS NOT PROPERLY CLOSED. TO BE COMPLETED PRIORTO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Engineering
Issued 5 December 1990
Resolved
THERE ARE NO REMOTE FUEL PUMP SHUTDOWNS.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Electrical
Issued 5 December 1990
Resolved
THERE ARE NO EMERGENCY LIGHTS AT LIFEBOATS OR LAUNCH AREA.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Navigation
Issued 5 December 1990
Resolved
THERE ARE NOT 2 MEANS TO COMMUNICATE WH TO ER. TO BE COMPLETED PRIOR TO ENTERING US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990
Resolved
THERE ARE NO REMOTE VENTILATION SHUTDOWNS.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Accommodation/Occupational Safety
Issued 5 December 1990
Resolved
SEVERAL AREA OF HANDRAILS AND STANCIONS ON MAIN AND BOAT DECK ARE DAMAGED. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 5 December 1990
Resolved
PORT LIFEBOAT WINCH FOUNDATION WASTED STEEL. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990
Resolved
NO GASKETS ON ER VENT COVERS. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 5 December 1990
Resolved
STBD LIFEBOAT RUDDER BROKEN.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 5 December 1990
Resolved
PORT LIFEBOAT - 2 OF 6 SHEAVES BROKEN. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 5 December 1990
Resolved
PORT LIFEBOAT - RATIONS 7 YRS OLD, NO BATTERIES IN FLASHLIGHTS, WATER TANK LOW. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 5 December 1990
Resolved
STBD LIFEBOAT - RATIONS 7 YRS OLD, NO WRENCH TO OPEN LOCKERS. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Construction/Loadline
Issued 5 December 1990
Resolved
MAIN DK EXT. LONGITUDINALS WASTED STEEL. TO BE COMPLETED PRIOR TO ENTERINGANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Construction/Loadline
Issued 5 December 1990
Resolved
FOREPEAK BREAST HOOK PLATES WASTED. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
3 FIRE HYDRANTS CARGO DECK MISSING HANDWHEELS.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
FIREMAIN SOFTPATCH OVER PORT CARGO MANIFOLD. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
3 FIREHOSE NOZZLES MISSING CARGO DECK.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
FIRE DAMPER MISSING, MOTOR MISSING, AND COVER MISSING STBD ER VENT. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
PORT E.R VENT FIREDAMPER FROZEN. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990
Resolved
E/R AND P/R CO2 SYSTEM DISCONNECTED AND BOTTLES MISSING, LAST SERVICE TAG 12-88.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Accommodation/Occupational Safety
Issued 5 December 1990
Resolved
INSIDE HANDRAIL MISSING FWD HOUSE MAIN TO LOWER DECK. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Engineering
Issued 5 December 1990
Resolved
ALL REMOTE FUEL VALVE TRIPS ARE WIRED OPEN.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Engineering
Issued 5 December 1990
Resolved
FUEL TANK SIGHT GLASS AUTO CLOSING VALVES OBSTRUCTED BY PIPING. TO BE COMPLETED PRIOR TO SAILING.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Construction/Loadline
Issued 5 December 1990
Resolved
W.T. DOORS - GALLEY AFT, P/R, ACCOMMODATIONS FWD TO CARGO DECK, - GASKETS MISSING OR DEFECTIVE AND DOGS MISSING. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990
Resolved
ALL WINGTANK ULLAGES HAVE HOLED FLAME SCREENS AND #45 WING (AFT) HAS PLASTIC PATCH ON ULLAGE COVER. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990
Resolved
CARGO MANIFOLD MISSING BLANK FLANGES AND MIN. 4 BOLTS PER FLANGE. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990
Resolved
ANCHOR WINDLASS FOUNDATION WASTED. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990
Resolved
CARGO PUMPS NOT WORKING EXCEPT NO 1 (AFT SWITCH) NO OTHER SHUTDOWNS TESTED.TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Navigation
Issued 5 December 1990
Resolved
STEERING DOES NOT WORK. DEMONSTRATE NORMAL AND EMERGENCY STEERING. REMOVE OIL BUCKET AND HOSE FROM STEERING STAND.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Navigation
Issued 5 December 1990
Resolved
THE COMMS BETWEEN W/H AND STEERING DOES NOT WORK.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Documentation
Issued 5 December 1990
Resolved
PROVIDE A LETTER FROM THE FLAG STATE THAT THE IOPP "FORM A" IS CORRECT FOR THE CARGOES CARRIED. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Construction/Loadline
Issued 5 December 1990
Resolved
MAKE 1 BALLAST TANK (AMIDSHIPS) GAS FREE AND OPEN FOR INSPECTION AT THE NEXT US PORT. PROVIDE A CERTIFIED CHEMIST CERTIFICATE.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Lifesaving
Issued 5 December 1990
Resolved
MOST BOAT OARS CRACKED. TO BE COMPLETED PRIOR TO ENTERING ANY US PORT.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Documentation
Issued 4 December 1990
Resolved
Oil record book entries not recorded as required in 33 CFR 151.25.
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Documentation
Issued 4 December 1990
Resolved
Oil transfer proceedures required by 33 CFR 155.750 were incomplete.
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Documentation
Issued 4 December 1990
Resolved
IOPP certificate required by 33 CFR 151.19 invalid due to missing supplement.
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Navigation
Issued 16 January 1989
Resolved
REPAIR OIL LEAK FROM STEERING WHEEL PEDISTAL ON BRIDGE PRIOR TO NEXT ENTRY U.S. WATERS.
Condition: Unknown
Due 16 January 1989
Resolved 16 January 1989
Unknown
Issued 16 January 1989
Resolved
REPAIR AND PROVE PROPER OPERATION OF OILY WATER SEPARATER PRIOR TO NEXT U.S. PORT ENTRY.
Condition: Unknown
Due 16 January 1989
Resolved 16 January 1989
Lifesaving
Issued 16 January 1989
Resolved
PROVIDE PROPER RING BOUY MOUNT FOR O-1 DECK PORT SIDE RING BOUY PRIOR TO NEXT ENTRY U.S WATERS
Condition: Unknown
Due 16 January 1989
Resolved 16 January 1989
Electrical
Issued 16 January 1989
Resolved
REPAIR OVERHEAD LIGHTING FIXTURE IN AFTER STEERING COMPARTMENT PRIO TO NEXTENTRY OF U.S. WATERS.
Condition: Unknown
Due 16 January 1989
Resolved 16 January 1989
Deck/Cargo
Issued 16 January 1989
Resolved
REPAIR PORT AN STBD CARGO CONTAINMENTS PRIOR TO LOADING CARGO. 46 CFR 153.232
Condition: Unknown
Due 16 January 1989
Resolved 16 January 1989
Documentation
Issued 9 April 1988
Resolved
SUBMIT IMO CERTIFICATE OF FITNESS TO CG HEADQUARTERS AND OBTAIN NEW SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 9 April 1988
Resolved 9 April 1988
Deck/Cargo
Issued 5 June 1987
Resolved
PRIOR TO CARRYING ANY NLS CARGO, DEMONSTRATE COMPLIANCE WITH MARPOL ANNEX II
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Accommodation/Occupational Safety
Issued 29 October 1986
Resolved
VESSEL HAS 2 (TWO) INSTALLED TOILETS WITH PIPING THAT LEADS DIRECTLY OVERBOARD AND NO MSD ON BOARD AS REQUIRED BY 33CFR159.7. VESSEL CITED FOR THIS DISCREP SEVERAL TIMES AND STILL NOT IN COMPLIANCE; REF:VI86021222; PS85050321. VESSEL ALSO NOT IN COMPLIANCE WITH COTP MIAMS DEVIATION (ENCL)
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Deck/Cargo
Issued 13 September 1986
Resolved
REPLACE FLAME SCREENS ON VACUUM SIDE OF P/V VALVES WITH SIZE 30 MESH SCREEN
Condition: Unknown
Due 13 September 1986
Resolved 13 September 1986
Accommodation/Occupational Safety
Issued 13 September 1986
Resolved
INSTALL A MARINE SANITATION DEVICE WHICH IS CERTIFIED ACCORDING TO THE REQUIREMENTS OF 33CFR159. UNTIL THIS IS ACCOMPLISHED, MAIN TAIN PORTABLE TOILET FACILITIES ON STERN AND LOCK PERMANENT TOILETS CLOESED IN U.S. WATERS.
Condition: Unknown
Due 13 September 1986
Resolved 13 September 1986
Deck/Cargo
Issued 19 June 1986
Resolved
MANIFOLD FOR CARGO PIPES NOT BLANKED OFF WITH FLANGE. VESSEL HAD NO FLANGE FOR MANIFOLD.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Electrical
Issued 19 June 1986
Resolved
MASTHEAD NAVIGATION RUNNING LIGHT WIRING IMPROPER. ELECTRICAL WIRING FOR LIGHT WAS NOT WORKING. CREW HAD RIGGED TEMP WIRING WITH EXTENSION CORDS ON DECK OF VSL.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Documentation
Issued 19 June 1986
Resolved
THE VESSELS OIL RECORD BOOK WAS NOT BEING USED AS REQUIRED. LAST ENTRY WAS 30NOV85.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Documentation
Issued 19 June 1986
Resolved
THE OIL TRANSFER PROCEDURES WERE INCOMPLETE. THE PROCEDURES DID NOT INCLUDEA LINE DIAGRAM.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Unknown
Issued 16 July 1985
Resolved
OBTAIN A SAFE FOR WORKERS CERTIFICATE FOR THE STEERING GEAR ROOM AND DEMONSTRATE THE OPERATION OF THE STEERING GEAR TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE A VALID CARGO SHIP SAFETY EQUIPMENT CERTIFICATE.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE A DECOMTAMINATION SHOWER AND EYEWASH IN THE CARGO AREA.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE THE WARNING SIGNS AS REQUIRED BY 46 CFR 35.30-1.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE A MARPOL 73/78 OIL RECORD BOOK FOR MACHINERY SPACE OPERATIONS (PART 1).
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE AN APPROVED MARINE SANITATION DEVICE.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE A LINE DIAGRAM OF BUNKER OIL TRANSFER PIPING.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE UPDATED OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE VALID LICENSES FOR THE REQUIRED COMPLEMENT OF OFFICERS AND CREW.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
MAKE PERMANENT REPAIRS TO FRAYED AND LOOSE WIRING IN THE ENGINE ROOM.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE UPDATED COMPASS DEVIATION TABLES.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE UPDATED RADIO AIDS TO NAVIGATION.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE NEW LINE THROWING ROCKETS.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE A VALID CARGO SHIP SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE A CORRECTED COPY OF THE IOPP CERTIFICATE.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE CURRENT TIDE TABLES.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE UPDATED LIGHT LIST.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
MAKE PERMANENT REPAIRS TO ALL FIXED WIRING ON DECK.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
REMOVE ALL PROTABLE ELECTRICAL EQUIPMENT FROM CARGO AREA.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
MAKE THE PUMP ROOM ACCESSIBLE TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
MAKE PERMANENT REPAIRS TO THE PUMPROOM VENTILATION.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
FREE UP ALL CARGO TANK P/V VALVES.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
MOVE THE TWO AFT TANK VENT OUTLETS TO AT LEAST 10 METERS FROM THE SHIP'S HOUSE.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Unknown
Issued 16 July 1985
Resolved
PROVIDE TWO ADDITIONAL FIREMAN'S OUTFITS FOR A TOTAL OF FOUR.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Accommodation/Occupational Safety
Issued 15 July 1985
Resolved
33CFR159.7(C) EXISTING VESSEL, BUILT IN 1964, HAS INSTALLED TOILET FACILITIES AND NO TYPE I, II, OR III MSD ONBOARD.
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985
Documentation
Issued 15 July 1985
Resolved
33CFR155.750(A)(2)(I) NO LINE DIAGRAM OF BUNKER OIL TRANSFER PIPING SYSTEM ONBOARD.
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985
Documentation
Issued 15 July 1985
Resolved
33CFR151.25(A) NO MARPOL 73/78 OIL RECORD BOOK FOR MACHINERY SPACE OPERATIONS (PART I) ONBOARD.
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985