SPARTAN RIG 202

SPARTAN RIG 202 is a 1969 mobile offshore drilling unit. The Coast Guard has recorded 83 inspections since 1982, most recently in December 2020, along with 116 deficiencies and 2 casualty investigations between 2012 and 2013.

Records from 1982 to 2020. Most recent: inspection, 9 December 2020.

Built
1969
Last inspected
9 December 2020
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8751813 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WSG4638
Flag
UNITED STATES
—
Maury page id
psix-54167

Inspections, by type

…with no type recorded24
Years with a record 27 calendar years (1982–2020)
The 83 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)210.1 ft × 170.1 ft × 27.5 ft
Registered tonnagegross 4,889 / net 4,889
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBETHLEHEM STEEL · BEAUMONT, TX, UNITED STATES · built 1969
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itMobile Offshore Drilling Unit
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4889 - Regulatory (Subpart C or D), Gross Ton
4889 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBT3948MMSI not assigned · expired · voluntarily equipped · granted 18 July 1994, cancelled 26 September 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 83

9 December 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7109280
28 November 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7103806
26 March 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4823238
10 March 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4823303
19 February 2012 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4249958
19 February 2012 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4250008
22 February 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3686027
8 February 2010 Underwater Inspection in lieu of Drydock · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3673848
13 February 2009 Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3417569
10 December 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3377821
25 April 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3192104
21 March 2008 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3158770
12 February 2007 Hull Examination · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2794926
8 January 2002 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1484846
27 September 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772936
26 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073180
21 February 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1058079
8 October 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 823548
31 January 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1048098
23 November 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810104
4 October 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1369385
1 July 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082569
30 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781263
24 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777559
17 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808025
28 October 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449115
23 September 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470184
21 May 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1126638
12 May 1998 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390791
15 April 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1123399
30 March 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 788664
26 March 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1122632
22 February 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129564
11 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114035
31 October 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781131
14 October 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364398
22 September 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112539
19 August 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119267
18 August 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783247
10 December 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443769
1 March 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 759430
18 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 193970
19 January 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1184974
5 December 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187750
22 November 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880395
19 October 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360295
27 April 1995 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 862995
29 November 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1179204
28 October 1994 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1432907
8 November 1993 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 714845
28 October 1993 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 40181
21 October 1993 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1429812
3 March 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 839873
17 February 1993 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1142327
23 April 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1237736
14 February 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1225315
15 October 1990 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1231906
11 September 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1230209
23 August 1989 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1349713
31 August 1988 Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1349890
14 August 1988 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1037101
3 June 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1198751
10 March 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1029850
28 September 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1317344
18 September 1987 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1314136
24 September 1986 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1312327
3 June 1986 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1015241
17 October 1985 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 994780
20 September 1985 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1302340
27 June 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291631
1 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287877
10 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1290243
17 February 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 976167
28 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976153
16 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286231
15 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286229
14 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978423
5 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978588
9 July 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1285109
27 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281186
12 October 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1272043
18 October 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 964164
14 October 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1272165

Deficiency record · 116

Lifesaving › Lifeboat › Markings
Issued 10 March 2014 Resolved
Lifeboat #1 missing interior light, missing exterior light, retroflective tape faded, missing letters on lifeboat name. Repair/replace to original condition.
Due 10 April 2014
Resolved 22 May 2014
Lifesaving › Lifeboat › Hull
Issued 10 March 2014 Resolved
Lifeboat #1 no longer orange in color. Recondition to original condition.
Due 10 June 2014
Resolved 8 April 2014
Resolution: Reconditioned lifeboat #1
Lifesaving › Lifeboat › Propulsion Engine
Issued 10 March 2014 Resolved
Lifeboat #2 forward limit switch inop. Repair/replace to original condition.
Due 10 April 2014
Resolved 8 April 2014
Resolution: Repaired limit switch
Lifesaving › Lifeboat › Carriage Requirement
Issued 10 March 2014 Resolved
Lifeboat #2 head rest falling off of bulkhead and gyrocompass light inop. Repair/replace to original condition.
Due 10 April 2014
Resolved 22 May 2014
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 10 March 2014 Resolved
Embarkation ladders are >20' above waterline, extend ladders to waterline.
Due 10 April 2014
Resolved 12 June 2014
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 March 2014 Resolved
Missing exhaust shielding on standby generator. Replace/repair to original condition.
Due 10 April 2014
Resolved 8 April 2014
Resolution: Replaced
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 March 2014 Resolved
Standby generator leaks
Due 10 April 2014
Resolved 8 April 2014
Resolution: Old pipe was replaced.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 10 March 2014 Resolved
Move satellite dish located on liferaft #2 winch to a different location. It is obstructing proper operation of winch brake.
Due 10 May 2014
Resolved 22 May 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 10 March 2014 Resolved
Paint locker CO2 instructions no longer readable, replace/repair to original condition.
Due 10 April 2014
Resolved 8 April 2014
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Cable
Issued 27 February 2012 Resolved
Identified isolated dead ended cables IVO of the cable tray above the main switchboard. Correct all dead ended and remove all abandoned cables.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 March 2012
Resolved 29 March 2012
Resolution: Verified that all isolated dead ended cables in IVO of the cable tray above main switchboard were removed and all others in the vicinity of the generator spaces were removed also.
Electrical › Electrical Distribution System (service) › Cable
Issued 19 February 2012 Resolved
Electrical fire located in cable tray above the main switchboard resulted in significant damage to all conductors leading to and from the switchboard. Make repairs to the satisfaction of the attending Coast Guard marine inspector prior to recommencing drilling operations.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 27 February 2012
Resolution: Verified repairs of systems and components damaged as a result of an earlier fire event. All repairs were acceptable and within standards.
Electrical › Electric Supply System (service) › Cable
Issued 19 February 2012 Resolved
Rig personnel exhausted supply of proper cable retaining devices. Replace all nylon/plastic and small cable retaining devices with banding of correct size on all conductors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 March 2012
Resolved 29 March 2012
Resolution: Verified that proper cable retaining devices were used on all conductors.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 February 2012 Resolved
Identified two battery operated emergency lights that were inoperative. Make repairs or renew emergency lights.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 March 2012
Resolved 29 March 2012
Resolution: Verified that all emergency lights in machinery spaces were operable.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 February 2012 Resolved
Inspection of junction box connections for the generator prime mover shutdowns revealed that twist on type connectors were not properly secured. Secure all twist on connectors to prevent loosening due to vibrations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 March 2012
Resolved 29 March 2012
Resolution: Verified that all twist on connectors inside of junction box were properly secured.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 21 March 2008 Resolved
No record of Fuel Transfer Fuel Hose Test. Purchase order for Fuel Hose was 2 years old.
Action required: 705 - Other - as specified
Due 21 April 2008
Resolved 25 February 2009
Resolution: Satisfactory fuel hose onboard.
Construction/Loadline › Hull › Hull Plating
Issued 24 May 2002 Resolved
CONDUCT PHASE II OF THE HULL EXAM.
Due 31 December 2002
Resolved 12 February 2007
Resolution: COMPLETED CREDIT DRYDOCK
Operations/Management › Drills/Instruction › Abandon Ship
Issued 24 May 2002 Resolved
ONCE PROPERLY MANNED CONDUCT A FIRE AND BOAT DRILL. LEGACY COMPONENT DESC: Launching/Recovery of Survival Craft
Due 31 December 2002
Resolved 12 February 2007
Resolution: CONDUCTED SATISFACTORY MAN OVERBOARD, FIRE AND ABANDON SHIP DRILLS
Fire Fighting
Issued 4 October 1999 Resolved
PROVIDE BETTER METHOD TO DETECT LOSS-OF-VENTILATION (LOSS OF RELATIVE NEGATIVE PRESSURE) BETWEEN MUD PIT ROOM AND ADJACENT ENCLOSED SPACES (MUD PUMP ROOM, PORT & STBD SACK STORAGE ROOMS).
Condition: Unknown
Due 4 November 1999
Resolved 7 February 2002
Fire Fighting
Issued 28 October 1998 Resolved
PROVIDE TWO OPERATIONAL O2/LEL METERS THAT HAVE BEEN CALIBRATED WITHIN THE PAST TWELVE MONTHS.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Lifesaving
Issued 28 October 1998 Resolved
PROVIDE APPROVED HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Lifesaving
Issued 28 October 1998 Resolved
REPLACE CRACKED SIDE WINDOW TO STARBOARD CRANE.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Unknown
Issued 28 October 1998 Resolved
REPLACE STARBOARD BOW OBSTRUCTION LIGHT.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Lifesaving
Issued 28 October 1998 Resolved
CONDUCT 1.1 RELEASE GEAR OPERATIONAL TEST ON BOTH BOATS. ALTERNATE TEST MUST BE APPROVED BY COGNIZANT OCMI.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Construction/Loadline
Issued 23 September 1998 Resolved
CONDUCT MAT UNDERSIDE SWIM-BY. PROVIDE COPY OF VIDEO & DIVE REPORT TO [name withheld].
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Construction/Loadline
Issued 12 May 1998 Resolved
Submit repair proposal to [name withheld] on 5'x7' indent on outboard sideof No.3 leg at 37'-11" level. Repairs to be commenced I.A.W. construction portfolio and to the satisfaction of the attending marine inspector. Stiffeners inserted are temporary means for repair only.
Condition: Unknown
Due 24 May 1998
Resolved 2 July 1998
Electrical
Issued 14 October 1997 Resolved
PROPERLY TERMINATE DEAD WIRE CABLE IN #2 LEG AREA.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Navigation
Issued 14 October 1997 Resolved
INSTALL PROPER LIGHT BULBS IN NAVIGATION LIGHTS.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Engineering
Issued 14 October 1997 Resolved
CROP/RENEW KEEL COOLER PIPING IN #2 GENERATOR ROOM.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 14 October 1997 Resolved
PROVIDE 12 HAND HELD PARACHUTE FLARES FOR RIG.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Electrical
Issued 14 October 1997 Resolved
RENEW WIRE CABLE CLAMPS ON WIRE RUNS IN SHAKER AREA.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 10 December 1996 Resolved
REPLACE ALL LIFE RING BUOYS ON RIG.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Documentation
Issued 10 December 1996 Resolved
MAKE CORRECTIONS TO FIRE & SAFETY PLAN TO REFLECT ACTUAL CONFIGURATION OF GENERAL ALARM SYSTEM AND SUBMIT TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 14 April 1997
Resolved 14 April 1997
Construction/Loadline
Issued 10 December 1996 Resolved
RENEW WATEST LONGITUDINAL BOTTOM FRAMES (9EA) IN BOTTOM BAY AND RENEW LADDER.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Lifesaving
Issued 10 December 1996 Resolved
EFFECT PERMANENT REPAIRS TO GENERAL ALARM BELL PORT SIDE MAIN DECK.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Construction/Loadline
Issued 10 December 1996 Resolved
CONDUCT SWIMBY OF MAT SIDES AND BOTTOM, VIDEO SAME IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Construction/Loadline
Issued 10 December 1996 Resolved
REINSTALL NETTING ON HELO DECK WITH METAL TIES IN STEAD OF PLASTIC WIRE WRAPS.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Lifesaving
Issued 10 December 1996 Resolved
INTALL GENERAL ALARM BELLS IN THE FOLLOWING LOCATIONS: STORE ROOM ADJACENT TO STARBOARD SACK ROOM, STORE ROOM ADJACENT TO PORT SACK ROOM, & STORE ROOMADJACENT TO COMPRESSOR ROOM.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Lifesaving
Issued 10 December 1996 Resolved
INSTALL FLASHING RED LIGHT FOR GENERAL ALARM IN THE COMPRESSOR ROOM.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Construction/Loadline
Issued 10 December 1996 Resolved
HAVE FOUR (4) SIX INCH GATE DUMP VALVES OPEN FOR INTERNAL INSPECTION.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Unknown
Issued 10 December 1996 Resolved
SUBMIT ALL REPORTS AND COPIES OF VIDEOS TO [name withheld], LA.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Unknown
Issued 10 December 1996 Resolved
HAVE ALL AIR RECEIVERS AND BULK TANKS READY FOR INSPECTION.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Lifesaving
Issued 10 December 1996 Resolved
PLACE RETROREFLECTIVE TAPE ON ALL RING BUOYS AND BOTH ESCAPE CAPSULES.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Construction/Loadline
Issued 10 December 1996 Resolved
PROPERLY REPAIR/RENEW #111 PORT VOID HATCH COVER AND BOLT RING.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Documentation
Issued 22 November 1995 Resolved
SUBMIT REVISED FIRE AND SAFETY PLAN TO [name withheld] COMPLETION OF INSTALLATION OF NEW FIRE HYDRANT STATIONS IN MACHINERY SPACES.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Fire Fighting
Issued 22 November 1995 Resolved
HAVE INSTALLATION OF NEW FIRE HYDRANTS IN MACHINERY SPACES INSPECTED AND TESTED BY AN ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Engineering
Issued 19 October 1995 Resolved
INSTALL FLAME IMPINGEMENT BOWLS ON PUMP PRIME MOVER FUEL FILTERS ON MUD PUMPS.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Lifesaving
Issued 19 October 1995 Resolved
PROVE PROPER OPERATION OF GENERAL ALARM CONTACT MAKER ON DRILL FLOOR.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Lifesaving
Issued 19 October 1995 Resolved
INSTALL GENERAL ALARM BELL THAT CAN BE HEARD IN SHAKER HOUSE.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Electrical
Issued 19 October 1995 Resolved
PROPERLY SECURE ALL ELECTRICAL CABLES ON DERRICK, RIG FLOOR, AND IN VICINITY OF LOGGING TRAILER.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Electrical
Issued 19 October 1995 Resolved
LABEL UNMARKED MOTOR CONTROLLER OUTSIDE MUD PIT ROOM.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Navigation
Issued 19 October 1995 Resolved
PROVIDE PROPER BULBS FOR NAVIGATION LIGHTS.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Lifesaving
Issued 19 October 1995 Resolved
PERFORM QUARTERLY LAUNCH AND OPERATIONAL TESTS ON BOTH LIFEBOATS.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Fire Fighting
Issued 19 October 1995 Resolved
SUBMIT PLANS FOR APPROVAL TO INDICATE ADDITIONAL FIRE STATIONS IN MACHINERYSPACES SO THAT ALL POINTS CAN BE REACHED BY TWO EFFECTIVE STREAMS OF WATER.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Lifesaving
Issued 19 October 1995 Resolved
PROPER STENCIL ALL GENERAL ALARM CONTACT MAKERS.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Construction/Loadline
Issued 19 October 1995 Resolved
PLUG ALL OPENINGS IN WATERTIGHT BULKHEADS WHERE VENT FANS HAVE BEEN REMOVED.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Lifesaving
Issued 19 October 1995 Resolved
REPOSITION OBSTRUCTION LIGHT5S SO THAT ALL FOUR ARE ON SAME HORIZONTAL PLANE.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Lifesaving
Issued 19 October 1995 Resolved
REPAIR/RENEW COMPASS IN LIFEBOAT #2.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Lifesaving
Issued 19 October 1995 Resolved
PROVIDE WEIGHTS (MONKEY'S FISTS) FOR HEAVING LINES IN BOTH LIFEBOATS.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Documentation
Issued 19 October 1995 Resolved
PROVIDE RENEWAL DECAL AND OWNER ADDRESS CHANGE LABEL FOR VESSEL CERTIFICATEOF DOCUMENTATION.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Construction/Loadline
Issued 19 October 1995 Resolved
REPAIR LADDER SUPPORT BRACKETS FOR LADDERS FROM LIFEBOAT EMBARKATION DECKS TO MAIN DECK.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Lifesaving
Issued 19 October 1995 Resolved
PROVIDE BOARDING LADDERS FOR BOTH LIFEBOATS.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Lifesaving
Issued 19 October 1995 Resolved
PROVIDE 5 ADDITIONAL CARTRIDGES AND 1 LINE CANISTER FOR LINE THROWING GUN.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Accommodation/Occupational Safety
Issued 21 October 1993 Resolved
REPARE WASTED STEEL IN "I" BEAM TO STBD LADDER TO HELO DECK.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Electrical
Issued 21 October 1993 Resolved
REPARE GENERAL ALARM BELL OVER STAIRWAY TO MUD PIT ON THE MAIN DECK & IN THE MUD PUMP ROOM.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Fire Fighting
Issued 21 October 1993 Resolved
PROVIDE SMOKE DETECTORS FOR ALL ACCOMODATION SPACES.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Lifesaving
Issued 21 October 1993 Resolved
PROVE PROPER OF ALL LIFEBOAT AND LIFERAFT EMBARKATION LIGHTS.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Electrical
Issued 21 October 1993 Resolved
POUR E-Y-S FITTINGS IN MUD PIT & DRILL FLOOR.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Electrical
Issued 21 October 1993 Resolved
PROVIDE ADDITIONAL GENERAL ALARM BELLS ALNG PORT SIDE OF MODU ON MAIN DECK.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Fire Fighting
Issued 21 October 1993 Resolved
REPARE VALVE IN FIRE HYDRANTS AT THE STATION IN THE MAIN DECK ACCOMIDATION PASSAGEWAY.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Construction/Loadline
Issued 21 October 1993 Resolved
CLOSE BULDHEAD PENETRATIONS IN MUD PITS.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Electrical
Issued 21 October 1993 Resolved
LABEL ALL GENERAL ALARM BELLS.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Electrical
Issued 21 October 1993 Resolved
LABEL ALL GENERAL ALARM CONTACT MAKERS.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Navigation
Issued 21 October 1993 Resolved
LIGHTS INOPERABLE.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Construction/Loadline
Issued 21 October 1993 Resolved
PROVIDE STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Electrical
Issued 21 October 1993 Resolved
REPLACE MAIN DECK VENT MOTOR CONTROLLERS WITH WEATHER-PROOF TYPE.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Lifesaving
Issued 21 October 1993 Resolved
PROVE PROPER OPERATION OF #2 CAPSULE SPRINKLER SYSTEM.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Electrical
Issued 21 October 1993 Resolved
PROVIDE BERTH LIGHTS FOR ALL BUNKS
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Electrical
Issued 21 October 1993 Resolved
REPLACE EMERGENCY LIGHT BATTERIES.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Engineering
Issued 21 October 1993 Resolved
POST POLLUTION PREVENTION PLACARDS.
Condition: Unknown
Due 4 November 1993
Resolved 4 November 1993
Electrical
Issued 21 October 1993 Resolved
RENEW SELF CLOSING EXPLOSION PROOF RECEPTACLES ON DRILL FLOOR.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Unknown
Issued 23 April 1991 Resolved
SUBMIT REPAIR PROPOSAL FOR AND, MAKE PERMANENT REPAIRS TO 10 INCH CRACK IN PORT LEG WRAPPER PLATE PRIOR TO OPERATION, PER MSO PORT ARTHUR LETTER OF 20MAY 1991.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Unknown
Issued 15 October 1990 Resolved
OFFICE ISSUE CG-835: EXAMINE AND DETERMINE EXTENT OF 10 INCH CRACK IN PORT LEG WRAPER PLATE AND SUBMIT PROPOSAL FOR REPAIR OF SAID CRACK.
Condition: Unknown
Due 15 October 1990
Resolved 15 October 1990
Unknown
Issued 15 October 1990 Resolved
REPLACE WASTED LONGITUDINAL BULKHEAD STIFFENERS LOCATED IN #11 STARB. VOID
Condition: Unknown
Due 15 October 1990
Resolved 15 October 1990
Unknown
Issued 15 October 1990 Resolved
REPLACE DECK STIFFENERS LOCATED IN BOTH THE FORWARD AND STBD LOWER LEG ROOM
Condition: Unknown
Due 15 October 1990
Resolved 15 October 1990
Unknown
Issued 11 September 1990 Resolved
RENEW HULL MARKINGS WITH NEW VESSEL NAMES.
Condition: Unknown
Due 11 September 1990
Resolved 11 September 1990
Unknown
Issued 11 September 1990 Resolved
MAKE HELIPORT SURFACE NON-SKID AND MARK WITH AIMING CIRCLE.
Condition: Unknown
Due 11 September 1990
Resolved 11 September 1990
Unknown
Issued 11 September 1990 Resolved
REPLACE FUEL TANK AND OIL TANK SIGHT GLASSES WITH FIRE RESISTANT MATERIAL.
Condition: Unknown
Due 11 September 1990
Resolved 11 September 1990
Unknown
Issued 11 September 1990 Resolved
REPAIR RESTRAINING TIES FOR WIRING WITH STEEL WRAPS WHERE NEEDED IN MUD PITAND MUD PUMP ROOMS.
Condition: Unknown
Due 11 September 1990
Resolved 11 September 1990
Unknown
Issued 11 September 1990 Resolved
CONDUCT EMERGENCY DRILLS IN PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 11 September 1990
Resolved 11 September 1990
Engineering
Issued 31 August 1988 Resolved
PREPARE AIR RECEIVER AT DRILL FLOOR FOR INSPECTION.
Condition: Unknown
Due 31 August 1988
Resolved 31 August 1988
Engineering
Issued 18 September 1987 Resolved
REPLACE BROKEN SIGHT GLASS IN LUBE OIL TANK ON DRILL FLOOR
Condition: Unknown
Due 18 September 1987
Resolved 18 September 1987
Unknown
Issued 18 September 1987 Resolved
REPAIR DOOR CLOSER IN STBD SIDE OF MUD PIT ROOM
Condition: Unknown
Due 18 September 1987
Resolved 18 September 1987
Electrical
Issued 18 September 1987 Resolved
FLEX FUEL HOSE ON EMERGENCY GENERATOR ABOVE DRILL FLOOR TO BE HARD PIPED WITH THE EXCEPTION OF 12" FOR VIBRATION
Condition: Unknown
Due 18 September 1987
Resolved 18 September 1987
Accommodation/Occupational Safety
Issued 17 October 1985 Resolved
REPAIR AND PROVE OPERATIONAL, THE REMOTE VENTILATION SHUTDOWN.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 20 September 1985 Resolved
CONDUCT A WEIGHT TEST OF THE STARBOARD LIFE CAPSULE AT THE NEXT SCHEDULED MID-PERIOD REINSPECTION IN THE PRESENCE OF A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 September 1985
Resolved 20 September 1985
Unknown
Issued 1 April 1985 Resolved
PROVIDE [name withheld], TEXAS, WITH A COPY FO THE ULTRASONIC TESTING REPORT COMPLETED BY BETHLEHEM SHIPYARD ON REPAIRS TO THE #3 LEG.
Condition: Unknown
Due 1 April 1985
Resolved 1 April 1985
Construction/Loadline
Issued 17 February 1985 Resolved
COMPLETE THE UNDERWATER EXAMINATION OF THE SIDE AND THE BOTTOM OF THE MAT.
Condition: Unknown
Due 17 February 1985
Resolved 17 February 1985
Engineering
Issued 17 February 1985 Resolved
WITH THE HULL IN THE WATER, MAKE THE TAILSHAFTS AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 17 February 1985
Resolved 17 February 1985
Construction/Loadline
Issued 17 February 1985 Resolved
SUBMIT CALCULATIONS SHOWING THAT THE SET IN OF ABOUT 2 & 1/2 INCHES ON THE OUTSIDE OF THE #3 LEG, PORT SIDE, AT THE 128' MARK HAS NOT COMPROMISED THE STRUCTURAL INTEGRITY OF THE LEG, OR MAKE PERMANENT REPAIRS TO THE LEG AND RESTRICT YOKE PIN PLACEMENT TO BELOW THE 128' MARK PRIOR TO REPAIRS.
Condition: Unknown
Due 17 February 1985
Resolved 17 February 1985
Construction/Loadline
Issued 17 February 1985 Resolved
MAKE THE DRILL WATER TANKS #1 PORT, #1 STARBOARD, #10 PORT, #10 STARBOARD, AND THE #1 CENTER SALTWATER TANK AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 17 February 1985
Resolved 17 February 1985
Construction/Loadline
Issued 17 February 1985 Resolved
MAKE THE MUD PIT DUMP SEA VALVE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 17 February 1985
Resolved 17 February 1985
Unknown
Issued 28 November 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO TNE MODU J.STORM I DN523782.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Lifesaving
Issued 28 November 1984 Resolved
REPLACE THE TWO WASTED LOWER DAVIT SUPPORTS IN WAY OF THE STBD CAPSULE DAVITASSEMBLY. THE PRESENT SUPPORTS CREATE A SAFETY HAZARD UPON COMPLETIONOF WORK. A WEIGHT TEST WILL BE REQUIRED TO BE PERFORMED IN THE PRESENCE OF A CG INSPECTOR.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Lifesaving
Issued 28 November 1984 Resolved
PROVIDE EMERGENCY LIGHTING AT BOTH CAPSULES AT EMBARKATION AND IN WATER POSITIONS. (46 FR 111.75-16)
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Deck/Cargo
Issued 28 November 1984 Resolved
MAKE AVAILABLE FOR HYDROSTATIC TEST AND RELIEF VALVE TEST THE AIR RECIEVER ON THE DRILL (146 CFR 6. 10-5),
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984 Resolved
PROVIDE APPROVED CONTRUCTION PORTFOLIO ABOARD THE RIG (NVC 4-78D(2)B.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984 Resolved
PROVIDE DOCUMENTATION ABOARD RIG SHOWING CRANES INSPECTED IN ACCORDANCE WITH API SPEC. (46 CFR 109.43).
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Lifesaving
Issued 28 November 1984 Resolved
REMOVE PORTSIDE PILOT LADDER.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Deck/Cargo
Issued 28 November 1984 Resolved
PROVIDE THREE (03) UL APPROVED MARINE TYPE FILTERS FOR DRAWWORKS ENGINES. 46 CFR 58.01.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Navigation
Issued 28 November 1984 Resolved
PROVIDE UL OR FM APPROVED COMMUNICATION PHONE SUITABLE FOR CLASSIFIED LOCATION IN MUD PIT ROOM. 46 CFR 111.105(7).
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Electrical
Issued 28 November 1984 Resolved
PROVIDE APPROVED SWITCHES (START/STOP) FOR MUD PIT AGITATOR IN MUD PIT ROOM
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Lifesaving
Issued 28 November 1984 Resolved
REMOVE 11 MAN LIFEBOAT STARBOARD SIDE AFT OR REPLACE WITH DAVIT LAUNCHED LIFERAFT. (NAVIC 3-78)
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Fire Fighting
Issued 28 November 1984 Resolved
PROVIDE TWO (2) APPROVED OXYGEN METERS ABOARD RIG. 46 CFR (108.497).
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Navigation
Issued 28 November 1984 Resolved
PROVIDE ONE BLACK DIAMOND AND TWO (2) BLACK BALL DAY SHAPES (33 CFR PT 67).
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Lifesaving
Issued 28 November 1984 Resolved
WEIGHT TEST STARBOARD CAPSULE IN THE PRESENCVE OF A USCG INSPECTOR.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Lifesaving
Issued 28 November 1984 Resolved
MARK RIG'S TWO CAPSULES WITH REQUIRED MARKINGS ( NAME, HOMEPORT, CAPACITY, BOAT NUMBER) IN ACCORDANCE WITH 46 CFR 108.648.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984

Casualty record · 2

19 February 2012Routine · role: Involved in a Marine Casualty · activity 4249958
26 January 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4523828
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.