Records from 1982 to 2007. Most recent: inspection, 5 October 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
5 October 2007
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3073872
24 October 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1076253
10 October 2000
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433725
11 December 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 812609
27 October 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1365424
28 October 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453526
13 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 800371
3 December 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1111683
4 November 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436002
7 August 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1430437
4 September 1996
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1439773
29 September 1995
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461665
14 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 643629
31 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 27611
8 September 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429939
15 June 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1017417
16 March 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 643630
23 February 1994
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 854134
17 February 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 112437
15 April 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458077
8 July 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467354
16 June 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1259797
17 April 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221665
3 October 1990
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221902
30 July 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 989738
22 July 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1213581
28 June 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 506258
6 April 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914721
5 May 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1352370
10 March 1989
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 900471
23 January 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1203427
14 July 1988
Re-Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1032858
22 July 1987
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1033346
27 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301643
16 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977967
25 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978980
11 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281842
22 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277923
Documentation
Issued 27 October 1999
Resolved
PROVIDE CORRECTED FIRE AND SAFETY PLAN FOR USCG VERIFICATION AND APPROVAL. SCHEDULE COAST GUARD VISIT TO VESSEL.
Condition: Unknown
Due 27 October 1999
Resolved 27 October 1999
Engineering
Issued 4 November 1997
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIPS WITH HAND TACH OR MOUNTED TACH FOR PORT/STBD GENERATORS AND BOW THRUSTER.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Construction/Loadline
Issued 4 November 1997
Resolved
REMOVE GASKET MATERIAL AND SILICON FROM TONNAGE OPENINGS.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Engineering
Issued 4 November 1997
Resolved
REPAIR OR RENEW RPM GAUGES MOUNTED ON PORT AND STBD GENERATORS.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Deck/Cargo
Issued 4 November 1997
Resolved
MAKE REPAIR TO ANCHOR WINDLASS BRAKES. ALLOW FOR PROPER OPERATION.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Accommodation/Occupational Safety
Issued 15 April 1993
Resolved
D1. MAKE PRESSURE VESSEL BULK TANKS AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Engineering
Issued 16 June 1992
Resolved
PROVIDE AN APPROVED AUTOMATION TEST PROCEDURE ON BOARD THE VESSEL
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Documentation
Issued 22 July 1990
Resolved
PROVIDE FOR EXAMINATION BY A USCG MARINE INSPECTOR A SCANTLING PLAN IAW 46 CFR 91.40-5(B).
Condition: Unknown
Due 22 July 1990
Resolved 22 July 1990