MAURY USCG vessel records
← All vessels

HAMMERHEAD

Built
1972
Last inspected
7 March 2016
Documentation
Expired · NVDC file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 March 2016
…with no type recorded1
…past their stated due date2
Operational controls 1 with no removal date recorded
Years with a record 1 calendar year (2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7228443
WDG8062
Flag
UNITED STATES
Maury page id
psix-54182

Documentation record

Registered dimensions (L × B × D)163.3 ft × 38.0 ft × 14.0 ft
Registered tonnagegross 336 / net 228
ITC dimensions (L × B × D)163.3 ft × 38.0 ft × 14.0 ft
ITC tonnagegross 631 / net 189
BuilderBURTON SHIPYARD INC · PORT ARTHUR, TX, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationExpired · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it631 - Convention (Subpart B), Gross Ton
336 - Regulatory (Subpart C or D), Gross Ton
189 - Convention (Subpart B), Net Ton
228 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 2 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each, 2 without one; 1 operational control with no removal date recorded; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SAVANNAH RIVER Industrial Vessel · MISLE 49354 · 7 March 2016 · activity 5828800

Inspection history · 2

7 March 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5828800
7 March 2016 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5830256

Deficiency record · 3

Construction/Loadline › Hull › Bottom Plating
Issued 9 March 2016 Resolved
Vessel developed hole in hull plating resulting in ingress of water.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2016
Resolved 9 May 2016
Resolution: Conducted visual weld inspection of all inserts and witnessed dye pen testing. All welding tested satisfactory.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 9 March 2016 No resolution recorded
Electrical installations damaged by water.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2016 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 9 March 2016 No resolution recorded
Machinery installations damaged by water.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2016 — due date passed with no resolution recorded

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.