MAURY USCG vessel records
← All vessels

DISCIPLESHIP

DISCIPLESHIP is a 1982 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in January 2026, along with 30 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 26 January 2026.

Built
1982
Last inspected
26 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 January 2026
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL9437
Flag
UNITED STATES
Maury page id
psix-54211

Documentation record

Registered dimensions (L × B × D)46.4 ft × 15.7 ft × 7.0 ft
Registered tonnagegross 35 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVIKING YACHT COMPANY · NEW GRETNA, NJ, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 10 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Simplified, Gross Ton
28 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

26 January 2026 COI Inspection · Administrative Inspection · Vessel Attendance · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8296943
21 March 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8097632
10 February 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8077469
23 January 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8066760
24 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7775875
17 January 2023 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7622631
25 January 2022 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7385856
26 November 2020 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7120329
17 November 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7096985
10 December 2019 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6870308
14 March 2019 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6642478
28 December 2018 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6604921
10 January 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6332145
6 December 2016 Annual Inspection · Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6053616

Deficiency record · 30

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 February 2025 Resolved
The vessel must have a Cat I EPIRB properly installed to float free. The EPIRB hydro release is expired. The vessel is restricted to not more than 3NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 March 2025
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 January 2023 Resolved
Inspect sea valves in accordance with 46 CFR 176.802. Stbd engine sea valve did not close fully.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2023
Resolution: New sea valve installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 January 2023 Resolved
Inspect machinery in accordance with 46 CFR 176.804. Stbd engine operation was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2023
Resolution: Engine rebuilt.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 January 2023 Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 January 2025
Resolution: Equipment installed and tested. No more restrictions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2023 Resolved
Provide means of escape in accordance with 46 CFR 177.500. Fwd port and stbd escape hatches cannot be opened from the exterior.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 24 August 2023
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 January 2023 Resolved
Inspect hull in accordance with 46 CFR 176.802. Port and stbd aft gunwales were cracked at the outside shell.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 29 March 2023
Resolution: Gunwales repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 January 2023 Resolved
Generator must be designed for 50C in accordance with 46 CFR 183.320. New generator installation rated for 40C.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 24 August 2023
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2023 Resolved
Comply with Stability letter in accordance with 46 CFR 178.230. New generator was installed. Provide weight change.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 7 September 2023
Resolution: Received. Refer to Act# 7775875 for more details.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 November 2020 Resolved
Provide proof of nautical charts for operating area.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 January 2022
Resolution: Owner provided up to date chart
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 November 2020 Resolved
Provide a watertight container for distress signals. Label and provide proof.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 January 2022
Resolution: Owner provided water tight container for distress signals and labeled as such.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 November 2020 Resolved
Finish deck box provide proof of completion.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 January 2022
Resolution: Completed deck box.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 November 2020 Resolved
Obtain new weak link and 02 paddles for life float. provide proof when obtained.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 January 2022
Resolution: Owner provided new weal link and 02 paddles for life float.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 November 2020 Resolved
Properly seal engine vents to secure air intakes.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 January 2022
Resolution: Owner properly sealed engine room vents for air inakes.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 26 November 2020 Resolved
Double up hose clamp on generator raw water system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 January 2022
Resolution: Owner added double hose clamps to SSDG raw water system.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 December 2019 Resolved
Masthead light extinguished. Prove proper operation of light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 22 January 2020
Resolution: Lamp replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 December 2019 Resolved
Port main engine is missing a hose clamp on saltwater intake hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 22 January 2020
Resolution: Engine winterized.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2019 Resolved
Remove dead end wire going between main cabin and engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 22 January 2020
Resolution: Dead end wire removed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 December 2019 Resolved
EPIRB is missing registration sticker. Provide and affix registration sticker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 22 January 2020
Resolution: Epirb sticker replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 December 2018 Resolved
Provide vessel with 6 red hand flares and 6 orange that are not expired. 46 CFR 180.68(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2019
Resolved 26 April 2019
Resolution: Flares purchased for vessel, No Sail Lifted.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 28 December 2018 Resolved
Reconnect deck drain hoses to prevent water ingress into vessel. 46 CFR "Old S" 171.124.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 20 March 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 December 2018 Resolved
Make shut off valve for forward Fuel Tank operable from outside the engine room. 46 CFR "Old T" 182.20-40
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 3 May 2019
Resolution: Remote pull for E/R Fuel tank shut off valve installed. Pull is located in same location as other fuel tank shutoff valves below aft cabin door.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 December 2018 Resolved
Provide a visual indicator at the operating station that indicates when any automatic bilge pump is operating. 46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 20 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 December 2018 Resolved
Wire splices shall be made in Junction boxes. 46 CFR "Old T" 183.05-50(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 20 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 December 2018 Resolved
Dead end wiring shall be renewed. 46 CFR "Old T" 183.01-15(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 20 March 2019
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 10 January 2018 Resolved
Place hull penetration for all electric submersible pumps onboard. 46 CFR 182.530(e)(7)
Action required: 705 - Other - as specified
Due 10 May 2018
Resolved 20 March 2019
Lifesaving › Hand Flares › Storage
Issued 10 January 2018 Resolved
Place flares in a brightly colored, watertight container marked "Distress Signals". 46 CFR 185.614.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 25 January 2018
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 January 2018 Resolved
Have FCC Licensed technician inspect Single Side Band Radio. 47 CFR 80.903
Action required: 705 - Other - as specified
Due 10 March 2018
Resolved 25 January 2018
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 6 December 2016 Resolved
46CFR16.401: Provide Certificate of Enrollment, Company Policy, and crew training for Drug and Alcohol Program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 15 December 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 December 2016 Resolved
46CFR182.530: Provide high bilge alarm light at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 15 December 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 December 2016 Resolved
46CFR185.510: Update emergency procedures to reflect onboard operations during man overboard drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 15 December 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.