Records from 2016 to 2026. Most recent: inspection, 26 January 2026.
Inspection history · 14
26 January 2026
COI Inspection · Administrative Inspection · Vessel Attendance · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8296943
21 March 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8097632
10 February 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8077469
23 January 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8066760
24 August 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7775875
17 January 2023
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7622631
25 January 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7385856
26 November 2020
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7120329
17 November 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7096985
10 December 2019
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6870308
14 March 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6642478
28 December 2018
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6604921
10 January 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6332145
6 December 2016
Annual Inspection · Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6053616
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 February 2025
Resolved
The vessel must have a Cat I EPIRB properly installed to float free. The EPIRB hydro release is expired. The vessel is restricted to not more than 3NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 March 2025
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 January 2023
Resolved
Inspect sea valves in accordance with 46 CFR 176.802. Stbd engine sea valve did not close fully.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2023
Resolution: New sea valve installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 January 2023
Resolved
Inspect machinery in accordance with 46 CFR 176.804. Stbd engine operation was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2023
Resolution: Engine rebuilt.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 January 2023
Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 January 2025
Resolution: Equipment installed and tested. No more restrictions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2023
Resolved
Provide means of escape in accordance with 46 CFR 177.500. Fwd port and stbd escape hatches cannot be opened from the exterior.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 24 August 2023
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 January 2023
Resolved
Inspect hull in accordance with 46 CFR 176.802. Port and stbd aft gunwales were cracked at the outside shell.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 29 March 2023
Resolution: Gunwales repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 January 2023
Resolved
Generator must be designed for 50C in accordance with 46 CFR 183.320. New generator installation rated for 40C.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 24 August 2023
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2023
Resolved
Comply with Stability letter in accordance with 46 CFR 178.230. New generator was installed. Provide weight change.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 7 September 2023
Resolution: Received. Refer to Act# 7775875 for more details.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 November 2020
Resolved
Provide proof of nautical charts for operating area.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 January 2022
Resolution: Owner provided up to date chart
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 November 2020
Resolved
Provide a watertight container for distress signals. Label and provide proof.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 January 2022
Resolution: Owner provided water tight container for distress signals and labeled as such.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 November 2020
Resolved
Finish deck box provide proof of completion.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 January 2022
Resolution: Completed deck box.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 November 2020
Resolved
Obtain new weak link and 02 paddles for life float. provide proof when obtained.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 January 2022
Resolution: Owner provided new weal link and 02 paddles for life float.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 November 2020
Resolved
Properly seal engine vents to secure air intakes.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 January 2022
Resolution: Owner properly sealed engine room vents for air inakes.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 26 November 2020
Resolved
Double up hose clamp on generator raw water system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 January 2022
Resolution: Owner added double hose clamps to SSDG raw water system.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 December 2019
Resolved
Masthead light extinguished. Prove proper operation of light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 22 January 2020
Resolution: Lamp replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 December 2019
Resolved
Port main engine is missing a hose clamp on saltwater intake hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 22 January 2020
Resolution: Engine winterized.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2019
Resolved
Remove dead end wire going between main cabin and engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 22 January 2020
Resolution: Dead end wire removed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 December 2019
Resolved
EPIRB is missing registration sticker. Provide and affix registration sticker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 22 January 2020
Resolution: Epirb sticker replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 December 2018
Resolved
Provide vessel with 6 red hand flares and 6 orange that are not expired. 46 CFR 180.68(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2019
Resolved 26 April 2019
Resolution: Flares purchased for vessel, No Sail Lifted.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 28 December 2018
Resolved
Reconnect deck drain hoses to prevent water ingress into vessel. 46 CFR "Old S" 171.124.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 20 March 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 December 2018
Resolved
Make shut off valve for forward Fuel Tank operable from outside the engine room. 46 CFR "Old T" 182.20-40
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 3 May 2019
Resolution: Remote pull for E/R Fuel tank shut off valve installed. Pull is located in same location as other fuel tank shutoff valves below aft cabin door.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 December 2018
Resolved
Provide a visual indicator at the operating station that indicates when any automatic bilge pump is operating. 46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 20 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 December 2018
Resolved
Wire splices shall be made in Junction boxes. 46 CFR "Old T" 183.05-50(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 20 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 December 2018
Resolved
Dead end wiring shall be renewed. 46 CFR "Old T" 183.01-15(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 20 March 2019
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 10 January 2018
Resolved
Place hull penetration for all electric submersible pumps onboard. 46 CFR 182.530(e)(7)
Action required: 705 - Other - as specified
Due 10 May 2018
Resolved 20 March 2019
Lifesaving › Hand Flares › Storage
Issued 10 January 2018
Resolved
Place flares in a brightly colored, watertight container marked "Distress Signals". 46 CFR 185.614.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 25 January 2018
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 January 2018
Resolved
Have FCC Licensed technician inspect Single Side Band Radio. 47 CFR 80.903
Action required: 705 - Other - as specified
Due 10 March 2018
Resolved 25 January 2018
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 6 December 2016
Resolved
46CFR16.401: Provide Certificate of Enrollment, Company Policy, and crew training for Drug and Alcohol Program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 15 December 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 December 2016
Resolved
46CFR182.530: Provide high bilge alarm light at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 15 December 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 December 2016
Resolved
46CFR185.510: Update emergency procedures to reflect onboard operations during man overboard drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 15 December 2016