RIVER QUEEN

RIVER QUEEN is a 1982 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1985, most recently in September 2020, along with 90 deficiencies — 2 with no resolution recorded —.

Records from 1985 to 2020. Most recent: inspection, 22 September 2020.

Built
1982
Last inspected
22 September 2020
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-54222

Inspections, by type

…with no type recorded4
Years with a record 30 calendar years (1985–2020)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.5 ft × 11.0 ft × 4.4 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDUCKWORTH BOATS, INC. · CLARKSTON, WA, UNITED STATES · built 1982
Hull materialAluminum
PropulsionGasoline Engine
Hull shapeShip
Hull configurationMonohull
Hailing portYUMA, AZ
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 43

22 September 2020 Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7071754
16 November 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6850202
10 September 2019 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6814148
26 December 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6602799
25 January 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6343737
16 December 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6045486
6 September 2016 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5989868
29 September 2015 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5731678
12 September 2011 DAPI Audit · Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4138397
21 October 2010 Simplified Stability Test · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3863214
3 December 2009 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3643432
26 November 2008 Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3370011
19 November 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3097630
1 November 2005 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2512143
18 January 2005 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2273830
20 December 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1951463
19 December 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1718293
26 December 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1473938
4 December 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1448384
12 January 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1445560
25 January 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1125008
17 November 1998 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1446706
4 September 1998 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1132008
11 May 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1427519
3 April 1997 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1368151
26 March 1996 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1367721
16 May 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1409307
16 August 1994 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 867294
1 April 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1170190
30 March 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1154843
1 April 1992 Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1259824
10 April 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1242770
3 April 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 908412
4 April 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 915366
5 April 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1206030
3 August 1988 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1035654
16 May 1988 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1197283
15 May 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1327219
8 April 1987 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1002656
12 May 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1296333
10 April 1986 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 999908
18 July 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 982500
19 April 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 983612

Deficiency record · 90

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 December 2018 No resolution recorded
Annual inspection lapsed.
Action required: 17 - Rectify deficiencies prior to departure
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 January 2018 No resolution recorded
Lapse in annual exam
Action required: 701 - Prior to carriage of passengers/cargo
Communications › Alarms/Indicators › High Water Alarm
Issued 13 October 2015 Resolved
Provide visual indicator for high water alarm
Condition: Improper Installation
Due 13 November 2015
Resolved 13 November 2015
Resolution: Installed visual indicator
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 October 2015 Resolved
Provide lifering with proper line and light
Condition: Improper Installation
Due 13 November 2015
Resolved 13 November 2015
Fire Fighting › Fire Bucket › Lanyard
Issued 13 October 2015 Resolved
Provide lanyards for fire buckets
Condition: Improper Installation
Due 13 November 2015
Resolved 13 November 2015
Resolution: attached lanyards
Electrical › Lighting (service) › Conductor
Issued 12 September 2011 Resolved
Remove all wiring to the port and starboard deck lighting around the vessel.
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 2 November 2011
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 12 September 2011 Resolved
Renew fuel tank fill hose
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 2 November 2011
Engineering › Fuel Oil Service System › Hose
Issued 12 September 2011 Resolved
Renew starboard engine fuel line at the tank outlet.
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 2 November 2011
Engineering › Fuel Oil Service System › Hose
Issued 21 October 2010 Resolved
Renew cracked fuel hose on the port engine between the engine and fuel tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2010
Resolution: Received comfirmation via fax and phone call.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 October 2010 Resolved
Renew or hydrostatic test all portable fire extinguishers. (1- B1 and 1- BII)
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 27 October 2010
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 October 2010 Resolved
Renew Type I retro reflective tape on life preservers that’s old or peeling off.
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 October 2010 Resolved
Renew type II retro reflective tape on ring life buoy to rap around the body in four evenly spaced areas.
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Engineering › Gasoline Engine (propulsion) › Battery (4 cycle)
Issued 21 October 2010 Resolved
Provide battery boxes with lids. (Plastic battery box)
Action required: 705 - Other - as specified
Due 21 November 2010
Resolved 1 November 2010
Operations/Management › Drills/Instruction › Safety Orientation
Issued 3 December 2009 Resolved
Provide life jacket donning placard for each type life jacket carried onboard IAW 46CFR185.516.
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 2 April 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 December 2009 Resolved
Provide floating line for ring buoy IAW 46CFR180.70.
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 6 January 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 December 2009 Resolved
Renew expired items in first aid kit.
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 6 January 2010
Documentation › Logs/Records › Logbook (official)
Issued 3 December 2009 Resolved
Log drills quarterly IAW 46CFR185.520 and 524.
Action required: 705 - Other - as specified
Due 3 January 2010
Resolved 3 December 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 19 November 2007 Resolved
Replace expired Fire boy bottle/agent
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2007
Resolution: Fire boy system is operational
Electrical › Electric Generation Source (service) › Switch
Issued 19 November 2007 Resolved
Install interlock switch
Action required: 705 - Other - as specified
Due 24 December 2007
Resolved 19 December 2007
Resolution: Interlock was installed
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 1 November 2005 Resolved
Prove proper operation of flammable vapor detection system in accordance with all of 46CFR182.480 to include: - Procedures for checking proper operation posted at operating station. - FVDX must be operational for 30 seconds prior to engine start up. - Visual and audible alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 November 2005
Resolved 9 November 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 1 November 2005 Resolved
Prove proper operation of pre-engineered fixed gas fire extinguishing system auto shutdown IAW 46CFR181.420(a)(3) and override.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 November 2005
Resolved 9 November 2005
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 1 November 2005 Resolved
Provide red warning sign at operating station stating blowers shall be operated for sufficient time (at least 2 minutes) prior to starting engines (46CFR182.15-45(d) (Old T).
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 November 2005
Resolved 9 November 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 January 2005 Resolved
Provide 2 additional adult life jackets to meet number required by COI (47 toital) [46CFR180.71].
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2005
Resolved 30 August 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 January 2005 Resolved
Repair beckets on ring life buoy and provide proper lines on ring buoy and light. [46CFR180.70(b), (c) and (d).
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2005
Resolved 30 August 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 January 2005 Resolved
Provide battery boxes or covers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2005
Resolved 10 February 2005
Resolution: Battery boxes installed
Lifesaving › Hand Flares › Expired
Issued 18 January 2005 Resolved
Replace expired distress signals (3 flare and 3 smoke) [46CFR180.68 (b)
Due 18 February 2005
Resolved 30 August 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 January 2005 Resolved
Repair stern light [46CFR183.420 and 33 CFR 84 - inland rules.
Due 18 February 2005
Resolved 10 February 2005
Resolution: Stern light repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 January 2005 Resolved
Replace lens on combination masthead/anchor light and arrange switch as required. [46CFR183.420 and 33CFR84 -inland rules.
Due 18 February 2005
Resolved 10 February 2005
Resolution: Navigation lights repaired.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 January 2005 Resolved
Replace missing/expired items in first aid kit [46CFR184.710.
Due 18 February 2005
Resolved 30 August 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 January 2005 Resolved
Repair/replace portable fire extinguisher bracket in wheelhouse. [46CFR181.30 - 10 (b)]
Due 18 February 2005
Resolved 30 August 2005
Lifesaving › Hand Flares
Issued 12 December 2002 Resolved
Provide 03 red and 03 orange flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 12 December 2002 Resolved
Provide servicing for fixed system and fire extiquishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2002
Lifesaving
Issued 4 December 2001 Resolved
Replace waterlight lanyard.
Condition: Unknown
Due 1 February 2002
Resolved 26 March 2002
Lifesaving
Issued 4 December 2001 Resolved
Replace damaged ring buoy.
Condition: Unknown
Due 1 February 2002
Resolved 26 March 2002
Documentation
Issued 4 December 2001 Resolved
FAX drug program information to MSO San Diego Inspections department.
Condition: Unknown
Due 1 February 2002
Resolved 26 March 2002
Documentation
Issued 17 November 1998 Resolved
Add deck hand to drug testing program.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Engineering
Issued 17 November 1998 Resolved
Install vent closures for engine room.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Lifesaving
Issued 17 November 1998 Resolved
Renew eye wash in first aid kit._x001C_
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Fire Fighting
Issued 17 November 1998 Resolved
Install shut downs for engines to secure on discharge of halon.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Lifesaving
Issued 17 November 1998 Resolved
Renew 11 life jackets (adult). Passengers are reduced to 34 until new jackets are on board.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Documentation
Issued 11 May 1998 Resolved
PROVIDE COPY OF STABILITY LETTER._x001C_
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Navigation
Issued 11 May 1998 Resolved
PROVIDE PROPER ANCHOR LIGHT._x001C_
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Engineering
Issued 11 May 1998 Resolved
PROPERLY RE-ROUTE EXHAUST VENTILATION HOSES._x001C_
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Documentation
Issued 11 May 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Fire Fighting
Issued 11 May 1998 Resolved
REPAIR SHUTDOWN FOR FIXED HALON SYSTEM IN ENGINE ROOM._x001C_
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Lifesaving
Issued 3 April 1997 Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Fire Fighting
Issued 3 April 1997 Resolved
HAVE ON BOARD 3 2.5 GALLON BUCKETS
Condition: Unknown
Due 12 April 1997
Resolved 12 April 1997
Engineering
Issued 3 April 1997 Resolved
INSTALL TWO HOSE CLAMPS ON EACH F/O LINE CONNECTION
Condition: Unknown
Due 12 April 1997
Resolved 12 April 1997
Documentation
Issued 3 April 1997 Resolved
POST STABILITY LETTER
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Lifesaving
Issued 3 April 1997 Resolved
INSTALL RETROREFLECTIVE TAPE ON LIFERING BUOY
Condition: Unknown
Due 12 April 1997
Resolved 12 April 1997
Electrical
Issued 3 April 1997 Resolved
REPLACE WIRING TO STARTING BATTERY
Condition: Unknown
Due 12 April 1997
Resolved 12 April 1997
Construction/Loadline
Issued 3 April 1997 Resolved
REPAIR CRACKS IN LONDTIDUNAL FRAMES
Condition: Unknown
Due 12 April 1997
Resolved 12 April 1997
Lifesaving
Issued 3 April 1997 Resolved
POST LIFEJACKET PLACARD
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Lifesaving
Issued 3 April 1997 Resolved
HAVE ON BOARD APPROVED FIRST AID KIT
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Documentation
Issued 3 April 1997 Resolved
PROVIDE LOG FOR CREW TRAINING AND DRILLS
Condition: Unknown
Due 12 April 1997
Resolved 12 April 1997
Construction/Loadline
Issued 3 April 1997 Resolved
RENEW BILGE PUMP OVBD THRU HULL CONNECTION
Condition: Unknown
Due 12 April 1997
Resolved 12 April 1997
Engineering
Issued 26 March 1996 Resolved
Replace cracked fuel fill hose.
Condition: Unknown
Due 26 April 1996
Resolved 7 May 1996
Navigation
Issued 26 March 1996 Resolved
Replace missing stern light lens.
Condition: Unknown
Due 26 April 1996
Resolved 7 May 1996
Engineering
Issued 1 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROPER IGNITION PROTECTED DISTRIBUTORFOR THE MAIN GASOLINE ENGINES.
Condition: Unknown
Due 1 April 1994
Resolved 1 April 1994
Engineering
Issued 1 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, DOUBLE CLAMP ALL NON-METALLIC FLEXIBLE FUEL HOSES.
Condition: Unknown
Due 1 April 1994
Resolved 1 April 1994
Construction/Loadline
Issued 1 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, REMOVE ALL OILY WASTE FROM THE ENGINEROOM BILGE.
Condition: Unknown
Due 1 April 1994
Resolved 1 April 1994
Engineering
Issued 1 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, DOUBLE CLAMP ALL NON-METALLIC FLEXIBLE HOSES FOR THE MAIN ENGINE COOLING SYSTEMS.
Condition: Unknown
Due 1 April 1994
Resolved 1 April 1994
Construction/Loadline
Issued 1 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, PROPERLY SECURE OIL DRAIN LINES IN THE ENGINESPACE.
Condition: Unknown
Due 1 April 1994
Resolved 1 April 1994
Documentation
Issued 30 March 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Fire Fighting
Issued 30 March 1993 Resolved
PROVIDE ONE (1) B-II HAND PORTABLE FIRE EXTINGUISHER IN THE PASSENGER _x001C_ ACCOMMODATION AREA PRIOR TO PLACING VESSEL IN OPERATION. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Accommodation/Occupational Safety
Issued 30 March 1993 Resolved
REPLACE BROKEN GLASS WINDOW LOCATED AT PORTSIDE FORWARD ACCOMMODATION AREA._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Lifesaving
Issued 30 March 1993 Resolved
PROVIDE 12 HAND COMBINATION FLARES AND SMOKE SIGNALS OR 6 HAND RED FLARES_x001C_ AND 6 HAND ORANGE SMOKE DISTRESS SIGNALS. VESSEL OPERATION RESTRICTED TO _x001C_ 30 MINUTES OR LESS UNTIL REQUIREMENT IS COMPLETED. _x001C_ _x001C_
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Lifesaving
Issued 1 April 1992 Resolved
PROVIDE 6 (SIX) CG APPROVED FLARES AND 6 (SIX) CG APPROVED ORANGE SMOKES, OR 12 (TWELVE) CG APPROVED COMBINATION FLARES.
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Lifesaving
Issued 3 April 1991 Resolved
PROVIDE THREE ADULT LIFE PRESERVERS. RENEW REFLECTIVE MATERIAL ON LIFE PRESERVERS AS NEEDED.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Engineering
Issued 3 April 1991 Resolved
REPLACE CRACKED FLEX HOSE FUEL SUPPLY LINES WITH FLEX HOSE APPROVED FOR FUEL SERVICE.
Condition: Unknown
Due 3 April 1991
Resolved 3 April 1991
Fire Fighting
Issued 4 April 1990 Resolved
PROVIDE PROOF OF SERVICING OF PORTABLE FIRE EXTINGUISHERS AND FIXED BOTTLE IN ENGINE ROOM.
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Navigation
Issued 4 April 1990 Resolved
REPAIR STERN LIGHT.
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Documentation
Issued 4 April 1990 Resolved
PROVIDE AND POST EMERGENCY CHECKOFF LIST.
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Engineering
Issued 4 April 1990 Resolved
REPLACE CRACKED FLEXIBLE FUEL HOSE BETWEEN FUEL TANK AND FILTERS AND BETWEEN FUEL FILTERS AND ENGINE.
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Lifesaving
Issued 4 April 1990 Resolved
PROVIDE OPERABLE WATERLIGHT TO RING BUOY.
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Construction/Loadline
Issued 5 April 1989 Resolved
PROPERLY MARK VESSEL'S HULL ON PORT AND STBD BOW, AND TRANSOM IAW 46 CFR 67.15-3.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Engineering
Issued 5 April 1989 Resolved
PROVIDE FUEL TANK FILL PIPE WITH A SUITABLE CONDUCTOR BETWEEN THE FILL PIPEAND THE TANK TO MAINTAIN ELECTRICAL CONTINUITY IAW 46 CFR 182.20-30.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Electrical
Issued 5 April 1989 Resolved
PROVE PROPER OPERATION OF STBD E/R POWER EXHAUST FAN WHERE INOPERATIVE, AND RECONNECT SUCTION DUCTING IAW 46 CFR 182.15-45(A).
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Electrical
Issued 5 April 1989 Resolved
INTERLOCK ENGINEROOM EXHAUST BLOWERS WITH ENGINE IGNITION SWITCHES, AND PROVIDE A WARNING SIGN AT THE SWITCH IAW 46 CFR 185.15-45.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Engineering
Issued 5 April 1989 Resolved
REPLACE FLEXIBLE FUEL TANK FILL HOSE WHERE DETERIORATED.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Documentation
Issued 5 April 1989 Resolved
PROVIDE ON BOARD AN EMERGENCY CHECK-OFF LIST IAW 46 CFR 185.25-5.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Documentation
Issued 5 April 1989 Resolved
PROVIDE ON BOARD VESSEL'S CURRENT MARINE DOCUMENT IAW 46 CFR 67.45-5.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Fire Fighting
Issued 5 April 1989 Resolved
PROVIDE PROOF OF ANNUAL SERVICING/WEIGHING OF VESSEL'S FIXED HALON SYSTEM IAW 46 CFR 176.25-25.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Engineering
Issued 5 April 1989 Resolved
PROVIDE DOUBLE HOSE CLAMPING FOR VESSEL'S WET EXHAUST.
Condition: Unknown
Due 5 April 1989
Resolved 5 April 1989
Lifesaving
Issued 15 May 1987 Resolved
LIFE PRESEERVER STORAGE BINS REQUIRED TO BE RE-LABELED (TO REFLECT NEW NUMBER OF LIFE PRESERVERS BEING STOWED IN EACH).
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Lifesaving
Issued 15 May 1987 Resolved
VESSEL RESTRICTED TO CARRYING NO MORE THAN 44 TOTAL PERSONS UNTIL 3 MORE ADULT LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Lifesaving
Issued 8 April 1987 Resolved
REPLACE EXISTING LIFE RING AND LINE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Documentation
Issued 12 May 1986 Resolved
SHOW PROOF OF DOCUMENTION OF THE SUBJECT VESSEL AS REQUIRED BY 46 CFR 67.01-5.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Fire Fighting
Issued 10 April 1986 Resolved
SHOW PROOF OF WEIGHTING OF CO2 BOTTLE FOR ENGINE SPACE AS PER 46 CFR 176.25-25 PRIOR TO 10 MAY 1986.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Lifesaving
Issued 10 April 1986 Resolved
PROVIDE ONE SERVICABLE USCG APPROVED LIFE PRESERVER AS PER 46 CFR 180.25(A)PRIOR TO 10 MAY 1986.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.