CAPT JOEL

CAPT JOEL is a 1982 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1982, most recently in July 2022, along with 49 deficiencies.

Records from 1982 to 2022. Most recent: inspection, 15 July 2022.

Built
1982
Last inspected
15 July 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF2514
Flag
UNITED STATES
367428940
Maury page id
psix-54228

Inspections, by type

…with no type recorded20
Years with a record 33 calendar years (1982–2022)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDL4368MMSI 367428940 · active · compulsorily equipped · granted 4 February 2020, expires 4 February 2030
WDF2514MMSI 367428940 · expired · compulsorily equipped · granted 22 October 2009, cancelled 28 December 2019
WDD9553MMSI 367313030 · expired · compulsorily equipped · granted 12 September 2007, cancelled 18 November 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDC2591MMSI 366995350 · expired · compulsorily equipped · granted 2 December 2004, cancelled 7 February 2015 · licensed under a name not among this hull’s recorded names (not shown)
WRB4874MMSI not assigned · expired · compulsorily equipped · granted 13 June 1997, cancelled 3 November 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 58

15 July 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7507676
9 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7108977
19 July 2018 Annual Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6447827
17 May 2018 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6417154
19 April 2017 In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6128477
3 November 2016 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6034460
26 May 2016 Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 5902123
8 February 2016 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5814184
16 November 2015 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5764214
22 October 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3349288
5 September 2007 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3050113
21 January 2007 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2859466
21 September 2006 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2783656
28 July 2005 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2434511
2 December 2004 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2254209
27 August 2003 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1894600
5 January 2003 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1732924
6 September 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1670293
31 August 2001 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1462987
26 September 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389194
15 October 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 7899
2 August 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441544
30 October 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803336
14 September 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463405
9 July 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364236
2 July 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442595
12 September 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 955863
16 July 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398489
8 November 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753845
7 November 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 193142
27 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192475
19 July 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371114
7 July 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1374091
17 January 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 223335
9 July 1993 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 846798
28 July 1992 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 943476
2 August 1991 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1244493
9 August 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 912023
6 March 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1238628
23 February 1990 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 920816
6 September 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1200515
9 August 1989 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1349351
21 January 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1200832
19 January 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1200745
12 August 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344916
22 October 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1017384
22 October 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1017790
10 September 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1005174
13 April 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322561
11 September 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313811
7 October 1985 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987984
31 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975829
4 October 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283496
3 May 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280289
5 March 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971351
9 November 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973824
3 October 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1277708
15 October 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272578

Deficiency record · 49

Communications › Radio Communications › VHF Radiotelephone
Issued 3 November 2016 Resolved
Vessel was not equipped with Digital Select Calling capability
Due 17 November 2016
Resolved 8 November 2016
Lifesaving › Lifefloat › Painter
Issued 3 November 2016 Resolved
Lifelfoat painter lines were not tied around body of floats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 November 2016 Resolved
Exhaust pipe hanger was broken on port main engine.
Condition: Damaged By Earlier Event
Due 13 November 2016
Resolved 8 November 2016
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 3 November 2016 Resolved
During test of fuel transfer pump noted a leak from suction side nipple when engerized. Crew to replace or tighten.
Action required: 703 - Prior to bunkering operations
Resolved 8 November 2016
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (air motor)
Issued 3 November 2016 Resolved
Air start hose on port generator was worn excessively. Needs replaced.
Due 10 November 2016
Resolved 8 November 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 February 2016 Resolved
Welds on both inboard MDEs S/W cooled exhaust piping were leaking. Welder called to repair.
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 8 February 2016
Resolution: Welds repaired.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 8 February 2016 Resolved
Fire pump and F/O transfer pump motor controller reset buttons were missing.
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 12 February 2016
Resolution: Reset buttons were installed.
Stability › Watertight Integrity › General
Issued 8 February 2016 Resolved
Rudder room flush deck hatch cover was missing its captive chain.
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 8 February 2016
Resolution: Chain installed.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 22 October 2008 Resolved
Vessel need an additional emergency light in engine room and passenger compartment.
Due 24 November 2008
Resolved 27 October 2008
Resolution: Two emergency lights installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 October 2008 Resolved
Repair wiring on starter valves, fuel transfer pump and water pressure pump.
Due 24 November 2008
Resolved 27 October 2008
Resolution: Wiring repaired
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 22 October 2008 Resolved
Portable fire extinguisher stored in closet in galley. Location not marked as fire extinguisher storage.
Due 24 November 2008
Resolved 27 October 2008
Resolution: Location of fire extinguisher marked.
Construction/Loadline › Structures › Deck Plating
Issued 22 October 2008 Resolved
Cracks were present in aft deck and lazerette above the waterline.
Due 24 November 2008
Resolved 27 October 2008
Resolution: Cracks were welded.
Lifesaving › Lifefloat › Float-free Link
Issued 18 September 2007 Resolved
Lifefloats had many issues. Light lanyards not spliced around body. New weak link required. New lanyard container required. The paddles were not lashed in each lifefloat. Lanyard was not spliced around bady of life float.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Resolution: All the above problems were addressed and fixed.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 September 2007 Resolved
11 Life preservers were in unservicable condition. They were the Kapok type and were leaking using the squeeze test. 23 addtional Life preservers needed there retro tape repaired or new retro applied.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Resolution: The above items were repaired and new life preservers were brought onboard to replace bad ones.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 September 2006 Resolved
Life line was not attached around the body of the life ring buoy.
Action required: 705 - Other - as specified
Resolved 21 September 2006
Resolution: Corrected on the spot
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 21 September 2006 Resolved
Aramatures on both generators were dirty.
Action required: 705 - Other - as specified
Resolved 21 September 2006
Documentation › Markings/Placards › Warning Signs
Issued 21 September 2006 Resolved
Emergency Stove disconnect instruction placard was missing.
Action required: 705 - Other - as specified
Resolved 21 September 2006
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 28 July 2005 Resolved
18 lifejackets failed inspection and destroyed in presence of CG Inspector. Maximum passenger count minimized to 42 until 18 additional lifejackets can be provided.
Due 5 August 2005
Resolved 3 August 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 28 July 2005 Resolved
4" pipe leaking from gray water tank into bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 July 2005 Resolved
Wheel house panel has one missing breaker without a blank cover.
Due 28 August 2005
Resolved 3 August 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 28 July 2005 Resolved
Restencil all lifesaving as required.
Due 5 August 2005
Resolved 3 August 2005
Fire Fighting › Means of Escape › Doorways
Issued 28 July 2005 Resolved
Label emergency exit as required.
Due 5 August 2005
Resolved 3 August 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 July 2005 Resolved
Secure port and starboard generator exhaust hangers.
Due 5 August 2005
Resolved 3 August 2005
Stability › Weathertight Integrity › General
Issued 28 July 2005 Resolved
Renew or repair lower dog on aft main deck door.
Due 5 August 2005
Resolved 3 August 2005
Stability › Watertight Integrity › General
Issued 28 July 2005 Resolved
Renew aft port side main deck window prior to vessel departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2005
Communications › Radio Communications › EPIRB
Issued 28 July 2005 Resolved
Test and log monthly EPIRB results.
Action required: 705 - Other - as specified
Resolved 3 August 2005
Electrical › Electric Generation Source (service) › Generator
Issued 28 July 2005 Resolved
Professionally clean port and starboard generator windings.
Due 5 August 2005
Resolved 3 August 2005
Stability › Watertight Integrity › General
Issued 28 July 2005 Resolved
Readjust both engine room watertight doors and forward escape hatch.
Due 5 August 2005
Resolved 3 August 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 July 2005 Resolved
Provide adequate exhaust insulation on all four propulsion engines and both generators.
Due 5 August 2005
Resolved 3 August 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 28 July 2005 Resolved
Properly label stove disconnect and repair or renew range hood light guard.
Due 5 August 2005
Resolved 3 August 2005
Engineering › Fuel Oil Service System › Hose
Issued 28 July 2005 Resolved
Inspect all fuel hoses and provide proper chaffing prevention material as necessary on all four propulsion engines and both generators.
Due 5 August 2005
Resolved 3 August 2005
Documentation › Certificates/Documents › FCC SSL
Issued 2 December 2004 Resolved
Missing updated FCC licenses. Also need Bill of sale.
Condition: Placed in Improper Service
Due 2 January 2005
Resolved 28 July 2005
Construction/Loadline
Issued 14 September 1998 Resolved
ADJUST THE QUICK ACTING WATER TIGHT DOORS LOCATED IN THE MACHINERY SPACES.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Accommodation/Occupational Safety
Issued 14 September 1998 Resolved
ILLUMINATE EMERGENCY ESCAPE HATCHES LOCATED IN THE ENGINE ROOM AND GENERATOR ROOM.
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Accommodation/Occupational Safety
Issued 14 September 1998 Resolved
MARK ALL LIFE JACKET STOWAGE COMPARTMENTS WITH NUMBER CONTAINED WITHIN AS PER 46 CFR 185.604(f).
Condition: Unknown
Due 14 September 1998
Resolved 14 September 1998
Navigation
Issued 16 July 1996 Resolved
PROVIDE PROOF OF MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Electrical
Issued 16 July 1996 Resolved
PROVIDE BLANK FOR FUSE BOX IN GALLEY.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Lifesaving
Issued 16 July 1996 Resolved
REPLACE/REPAIR (1)ONE LIFEFLOAT. NUMBER OF PASSENGERS REDUCED TO 48 MAX UNTIL LIFEFLOAT REPLACED.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Documentation
Issued 16 July 1996 Resolved
PROVIDE PROOF OF WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Documentation
Issued 19 July 1995 Resolved
PROVIDE COPY OF VALID FCC COMMUNICATIONS ACT SAFETY RADIOTELEPHONY CERTIFICATE TO COGNIZANT OCMI.
Condition: Unknown
Due 19 July 1995
Resolved 19 July 1995
Unknown
Issued 9 August 1990 Resolved
OBTAIN A COAST GUARD APPROVED FIRE NOZZLE FOR A TOTAL OF TWO ABOARD VESSEL.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Construction/Loadline
Issued 23 February 1990 Resolved
CROP TO GOOD METAL AND RENEW.
Condition: Unknown
Due 23 February 1990
Resolved 23 February 1990
Fire Fighting
Issued 9 August 1989 Resolved
OPEN AND INSPECT FIRE PUMP TO DETERMINE CAUSE OF LOW PRESSURE AND OUTPUT. MAKE PERMANENT REPAIRS TO SUBJECT PUMP.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Construction/Loadline
Issued 19 January 1989 Resolved
MAKE TEMPORARY REPAIR TO FORWARD ACCOMMODATION SPACE SUCH THAT IT IS WATERTIGHT.
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Construction/Loadline
Issued 19 January 1989 Resolved
MAKE PERMANENT REPAIR TO FORWARD EMERGENCY ESCAPE HATCH TO FORWARD ACCOMMODATION SPACE SUCH THAT IT FUNCTIONS PROPERLY AND IS WATERTIGHT WHEN CLOSED.
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Unknown
Issued 10 September 1987 Resolved
PROVIDE A COPY OF THE CURRENT CERTIFICATE OF DOCUMENTATION TO MARINE SAFETYOFFICE PORT ARTHUR, TEXAS.
Condition: Unknown
Due 10 September 1987
Resolved 10 September 1987
Unknown
Issued 10 September 1987 Resolved
RENEW THE THREE (3) INCH GATE VALVE ON THE STARBOARD SIDE AFT MAIN DECK.
Condition: Unknown
Due 10 September 1987
Resolved 10 September 1987
Unknown
Issued 4 October 1984 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR ALL FIVE LIFEFLOATS.
Condition: Unknown
Due 4 October 1984
Resolved 4 October 1984
Lifesaving
Issued 3 October 1983 Resolved
INTALL SEA PAINTERS AND FLOAT FREE LINKS ON LIFELOATS AS REQUIRED BY 46 CFR 180.15-5 AND 180.20-1.
Condition: Unknown
Due 3 October 1983
Resolved 3 October 1983