MAURY USCG vessel records
← All vessels

RTC 503

Built
1982
Last inspected
13 April 2010
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 13 April 2010
…with no type recorded73
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1982–2010)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCX8067
Flag
UNITED STATES
Maury page id
psix-54240

Documentation record

Tonnage as PSIX records it19049 - Dead Weight, Ton
9185 - Regulatory (Subpart C or D), Gross Ton
8243 - Convention (Subpart B), Gross Ton
9185 - Regulatory (Subpart C or D), Net Ton
6770 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 131 inspections, each with its date, unit and type; 81 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

Inspection history · 131

13 April 2010 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3715711
10 July 2007 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2990211
7 March 2007 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2884764
25 January 2007 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex II Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2861635
22 November 2006 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2827151
21 November 2006 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2827072
7 December 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex II Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2547394
4 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2349103
24 April 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2342212
21 January 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2278487
7 January 2005 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2270474
6 January 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2270331
18 November 2004 MARPOL Annex I Examination · COI Inspection · MARPOL Annex II Examination · MARPOL Annex V Examination · MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2243861
15 September 2004 Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2196174
2 August 2004 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2153268
10 September 2003 MARPOL Annex I Examination · MARPOL Annex II Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1901422
31 January 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1737850
15 October 2002 Hull Examination · MARPOL Annex I Examination · Internal Structural Exam · Cargo Tank Internal · MARPOL Annex V Examination · Periodic Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1689927
5 July 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1641545
4 April 2002 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1601272
3 April 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1600624
27 March 2002 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1608638
15 September 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1073522
30 August 2001 MARPOL Annex V Examination · COI Inspection · MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1393764
21 May 2001 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 479014
14 May 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 189918
14 May 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 765574
12 March 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1065239
13 September 2000 Re-Inspection · MARPOL Annex II Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415449
3 September 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 461123
11 April 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 716376
22 March 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 488399
13 March 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 88361
15 October 1999 Deficiency Check · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1426295
2 September 1999 MARPOL Annex V Examination · COI Inspection · MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1463513
3 March 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 486991
21 December 1998 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 809357
1 December 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 490698
29 October 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 206030
29 October 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 760305
6 October 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 421175
6 October 1998 MARPOL Annex II Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 801467
26 September 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 63317
11 May 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 493959
4 April 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 438066
20 March 1998 Damage Survey · Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1390744
17 February 1998 Permit to Proceed
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1113470
16 February 1998 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1462623
10 February 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 716436
9 February 1998 Examination of Repairs · Damage Survey · Permit to Proceed
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1470136
4 February 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 170613
23 December 1997 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 134214
20 December 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 496787
17 December 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 716438
27 October 1997 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 781663
24 October 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 496492
14 October 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 468054
2 September 1997 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396779
27 July 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 437292
8 March 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 528781
19 December 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 447318
10 November 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 866520
9 November 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 41246
31 October 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1167115
22 September 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1159134
10 September 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1367909
22 July 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1088880
21 July 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 534555
29 February 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 475170
20 November 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1427143
7 November 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441006
17 October 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 531560
11 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 512477
25 June 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 532792
20 March 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 376380
26 January 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 501009
8 January 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 514931
14 September 1994 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380099
15 June 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328105
11 February 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399979
26 July 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426815
17 May 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1382571
5 August 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 518330
7 July 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 468748
9 April 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1260581
2 April 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257651
22 March 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 32712
22 September 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 496600
24 June 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1308608
10 May 1991 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899731
26 March 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 903709
26 February 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 921934
22 January 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900876
21 November 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 520436
25 October 1990 Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900711
16 August 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 489497
8 August 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1230852
10 May 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1235136
4 May 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214672
23 April 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 915762
3 April 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223301
21 February 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 511285
30 January 1990 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 921675
11 November 1989 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1219596
19 July 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 492054
22 June 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1196760
21 April 1989 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1340302
20 January 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 511729
26 September 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1352515
25 July 1988 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1041077
5 July 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 540764
25 April 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341699
15 April 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1031875
20 January 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 499316
1 July 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 535883
13 May 1987 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1026340
13 May 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1026343
4 December 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 503797
30 September 1986 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1005288
6 May 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 494091
18 April 1986 COI Inspection · Credit Drydock
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303630
18 March 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 497581
11 October 1985 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1299131
23 September 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 458936
10 April 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 443910
7 January 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 977138
7 November 1984 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 446626
23 October 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1282355
19 August 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 524507
16 July 1984 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 522751
25 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967732

Deficiency record · 81

Engineering › Fuel Oil Service System › Hose
Issued 7 December 2005 Resolved
Various hose installed on pump and generator engines is not of approved type. Vessel to replace non-approved hose in oil, fuel and hydraulic service with materials meeting ASE J1942.
Condition: Improper/Lack of Maintenance
Due 7 January 2006
Resolved 12 December 2005
Resolution: Hoses replaced with appropriate materials.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Pressure
Issued 7 December 2005 Resolved
One B-V extinguisher provided to cover the cargo deck was found completely discharged. Provide B-V extinguisher in servicable condition.
Condition: Improper/Lack of Maintenance
Due 7 January 2006
Resolved 12 December 2005
Resolution: Unit recharged.
Operations/Management › Equipment Service/Testing
Issued 10 September 2003 Resolved
Explosimeter not operational LEGACY COMPONENT DESC: Explosimeter
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 10 October 2003
Resolution: Replaced with a new Multigas meter
Electrical › Lighting (service) › Lighting Fixture
Issued 10 September 2003 Resolved
Intrinsically safe lights in Bow thruster room are inoperable.
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 10 October 2003
Resolution: Light bulbs and fixtures replaced
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 September 2003 Resolved
Junction box cover missing
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 10 October 2003
Resolution: Junction box cover installed on box
Electrical › Lighting (emergency)
Issued 10 September 2003 Resolved
Emergency lights in generator inoperable.
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 10 October 2003
Resolution: Emergency lights repaired.
Electrical › Electric Supply System (service) › Cable
Issued 10 September 2003 Resolved
Exposed dead end wire on an accomodation house.
Condition: Unknown
Due 10 October 2003
Resolved 10 October 2003
Resolution: Wire removed
Lifesaving › Rocket Parachute Flares
Issued 10 September 2003 Resolved
12 Handheld flares onboard in lieu of rocket parachutes flares.
Condition: Unknown
Due 10 October 2003
Resolved 10 October 2003
Resolution: Rocket flares brought in to replace handhelds
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 September 2003 Resolved
Attenna atop accomodation spaced poorly rigged in an unsafe manner. LEGACY COMPONENT DESC: Recreation Space
Condition: Placed in Improper Service
Due 10 October 2003
Resolved 10 September 2003
Resolution: Antenna removed
Electrical › Electrical Distribution System (service)
Issued 30 October 2002 Resolved
Properly mount the electrical juntion box that is wrapped in plastic on aft bulkhead inboard side of bow thruster room. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 30 November 2002
Resolved 31 October 2002
Electrical › Electrical Distribution System (service)
Issued 30 October 2002 Resolved
Secure open wires on inboard bulkhead, in bow thruster room. The wires are sticking out of the pnuematic control panel. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 30 November 2002
Resolved 31 October 2002
Electrical › Electrical Distribution System (service)
Issued 30 October 2002 Resolved
Secure open wires on c-charge 9000 series, on inboard bulkhead (in bow thruster room). LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 30 November 2002
Resolved 31 October 2002
Electrical › Electrical Distribution System (service)
Issued 30 October 2002 Resolved
Secure open wire hanging off stbd side of bow thruster engine. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 30 November 2002
Resolved 31 October 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 30 October 2002 Resolved
Replace the missing lagging on exhaust piping on bow thruster engine. note=* 3 different places* LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Placed in Improper Service
Due 1 February 2003
Resolved 10 September 2003
Resolution: Lagging replaced
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 30 October 2002 Resolved
General house cleaning in cargo pump "B". Remove old/inop/unused pnuematic starter that is sitting in oil. (Tripping/Projectile hazard) LEGACY COMPONENT DESC: Cargo Pump
Condition: Improper/Lack of Maintenance
Due 30 November 2002
Resolved 31 October 2002
Pollution Prevention/Response › Prevention Equipment
Issued 30 October 2002 Resolved
Replace missing vapor recovery stud on all vapor recovery lines, with the exception of stbd aft . Correct prior to use!
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 30 October 2002 Resolved
Reinstall missing guages on cargo pumps as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 30 October 2002 Resolved
Install all cargo pump guages to be visable at the controlling station. Ensure all guages are calibrated and working properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 30 October 2002 Resolved
The #2 generator is missing lagging on its exhaust system. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Due 1 February 2003
Resolved 10 September 2003
Resolution: Lagging replaced
Pollution Prevention/Response › Prevention Equipment
Issued 30 October 2002 Resolved
Ensure the high pressure bullet valve for the vapor recovery system is operating properly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2002
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 30 October 2002 Resolved
Prior to cargo ops using cargo pumps located in pumphouse "A" and "B" (wasted and holed), flame arresters must replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2002
Lifesaving › Buoyant Apparatus
Issued 30 October 2002 Resolved
Replace inop marker light on port life buoy. Note*- Vessel in required to have only one light, two are onboard vessel. LEGACY COMPONENT DESC: Life buoy
Condition: Improper/Lack of Maintenance
Due 30 November 2002
Resolved 31 October 2002
Engineering › Compressed Air System (start air) › Valve
Issued 15 October 2002 Resolved
Replace inop relief valve on air reciever, prior to cargo ops.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2002
Deck/Cargo
Issued 13 September 2000 Resolved
Install mechanical valve indicators for non-rising stem cargo valves IAW 46CFR 56.20-9 at next scheduled dry docking.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Electrical
Issued 13 September 2000 Resolved
Prove proper parallel operation of #1 & 2 generators and reverse power relay (RPR).
Condition: Unknown
Due 15 September 2000
Resolved 14 September 2000
Construction/Loadline
Issued 13 September 2000 Resolved
Gas free vsl safe for hotwork and V/W 12" crack stbd side of anchor sled into fwd rake. Headlog likely damaged by anchor. No sail/ops outside of NY harbor.
Condition: Unknown
Due 15 September 2000
Resolved 14 September 2000
Deck/Cargo
Issued 13 September 2000 Resolved
Provide a shower/eyewash fountain IAW 46 CFR 153.216 on the weather deck.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Deck/Cargo
Issued 13 September 2000 Resolved
Repair/renew overfill alarm signs on deck alarm trees so they are readable.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Documentation
Issued 13 September 2000 Resolved
Provide MSDS/cargo info for NLS and hazardous cargo.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Accommodation/Occupational Safety
Issued 13 September 2000 Resolved
Prove proper operation of air receiver relief valve and relocate from bottom to top of tank. Condensation caused valve to deteriorate and not seat.
Condition: Unknown
Due 15 September 2000
Resolved 14 September 2000
Lifesaving
Issued 13 September 2000 Resolved
Repair oil leaks & clean on/around generators/pump engines.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Engineering
Issued 13 September 2000 Resolved
Install proper air start piping to aft pump engine in generator house. Use approved hose for flexibility only in lengths not exceeding 30". Approx. 30ft of unapproved hose connected from air rcvr and suspended by wire ties across generator house overhead to cargo pump air starting motor.
Condition: Unknown
Due 15 October 2000
Resolved 15 September 2000
Lifesaving
Issued 13 September 2000 Resolved
Renew expired Hammar liferaft hydrostatic release & properly attach prior to sailing outside of NY Port.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Engineering
Issued 13 September 2000 Resolved
Renew oil soaked lagging on #2 port aft generator.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Electrical
Issued 13 September 2000 Resolved
Remove spill gear from in front of stbd pump house electrical panels & properly stow.
Condition: Unknown
Due 13 September 2000
Resolved 14 September 2000
Electrical
Issued 13 September 2000 Resolved
Make permanent repairs, as original, to broken explosion-proof conduit at stbd hose boom switch.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Documentation
Issued 2 September 1999 Resolved
PROVIDE COPY OF APPROVED P & A MANUAL.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 2 September 1999 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF #1 AND #2 SHIP SERVICE GENERATOR OVERSPEEDS.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 2 September 1999 Resolved
INSTALL ELECTRICAL PANEL SWITCH ON FRONT COVER OF PANEL IN GENERATOR ROOM.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Accommodation/Occupational Safety
Issued 2 September 1999 Resolved
REMOVE WASHING MACHINE FROM GALLEY AREA.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Engineering
Issued 2 September 1999 Resolved
INSTALL A SIGHT GLASS GUARD FOR FUEL OIL DAY TANK IN GENERATOR ROOM.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 2 September 1999 Resolved
REMOVE WIRE NUTS FROM WIRE SPLICE ON AFT BATTERY CHARGER IN GENERATOR ROOM.
Condition: Unknown
Due 5 September 1999
Resolved 5 September 1999
Accommodation/Occupational Safety
Issued 2 September 1999 Resolved
PERMANENTLY MOUNT OR REMOVE LOCKER IN AFT BERTHING AREA.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Accommodation/Occupational Safety
Issued 2 September 1999 Resolved
MAKE WATERTIGHT BOTH EMERGENCY ESCAPES FROM BERTHING AREA'S.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 2 September 1999 Resolved
REPAIR EMERGENCY LIGHTING IN ACCOM PASSGEWAY.
Condition: Unknown
Due 5 September 1999
Resolved 5 September 1999
Electrical
Issued 2 September 1999 Resolved
INSTALL BLANK COVER ON OPEN BREAKER IN MAIN A.C. SWITCHBOARDS.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 2 September 1999 Resolved
PROVIDE AND INSTALL A LUBE OIL SHUTDOWN SWITCH ON #1 & #2 STARBOARD SIDE GENERATORS.
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Electrical
Issued 10 September 1996 Resolved
PROVE PROPER OPERATION OF S/S GENERATOR PARALLELING SWITCHGEAR AND REVERSE CURRENT PROTECTION AS PER 46 CFR 111.12-11(f).
Condition: Unknown
Due 5 November 1996
Resolved 5 November 1996
Lifesaving
Issued 10 September 1996 Resolved
PROPERLY INSTALL HAMMER BRAND HYDRAULIC RELEASE IN ACCORDANCE WITH MANUFACTURES INSTRUCTIONS AS PER 46 CFR 33.20-15(d).
Condition: Unknown
Due 5 November 1996
Resolved 5 November 1996
Lifesaving
Issued 10 September 1996 Resolved
REMOVE FLAMMABLES FROM MACHINERY SPACE AND STORE IN APPROVED FLAMMABLE LOCKER AS PER 46 CFR 147.45(b).
Condition: Unknown
Due 5 November 1996
Resolved 5 November 1996
Lifesaving
Issued 7 November 1995 Resolved
CLEAN OR REPLACE STARBOARD WARNING SIGN ON STARBOARD SIDE OF VESSEL.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Deck/Cargo
Issued 7 November 1995 Resolved
INSTALL ALIGNMENT PINS ON VAPOR RECOVERY SYSTEM FLANGE CONNECTIONS ON STARBOARD AND PORT SIDE MANIFOLDS.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Lifesaving
Issued 7 November 1995 Resolved
PROVIDE EMERGENCY OUTFIT AS PER 46 CFR 35.30-20(B). BARGE TO BE OPERATED ASAN UNMANNED TANK BARGE UNTIL SUCH TIME AS EMERGENCY OUTFIT IS ABOARD.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Lifesaving
Issued 7 November 1995 Resolved
BRING VESSEL INTO COMPLIANCE WITH MARINE OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR BENZENE CONTAINED IN 46 CFR 197 SUBPART C.
Condition: Unknown
Due 7 November 1995
Resolved 7 November 1995
Documentation
Issued 11 February 1994 Resolved
PRIOR TO PLACING VESSEL BACK IN SERVICE, ALL REQUIRED INSPECTIONS MUST BE COMPLETED, IAW MSM VOL II 8.A.4.D. TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Documentation
Issued 26 July 1993 Resolved
Vessel is to conduct all required inspections to satisfaction of attending CG Inspector_x001C_ _x001C_ Vessel is not to be loaded or moved until requirement complete.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Electrical
Issued 2 April 1992 Resolved
REPAIR PORT FORWARD VENT MOTOR HARDWIRE TO CONTROLLER. DEMONSTRATE WEATHERDECK SHUTDOWN.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Construction/Loadline
Issued 2 April 1992 Resolved
REPAIR AND MAKE WATER-TIGHT THE FORWARD PORT MACHY SPACE VENT COVER.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Lifesaving
Issued 2 April 1992 Resolved
REPAINT VAPOR RECOVERY INDICATOR SIGNS AT LIGHT TREES.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Electrical
Issued 2 April 1992 Resolved
REPAIR LIGHT FIXTURE HANGING BY WIRES, OUTBOARD SIDE GENERATOR ROOM.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Engineering
Issued 2 April 1992 Resolved
REMOVE VALVE FROM F/O TANK BOTTOM DRAIN.
Condition: Unknown
Due 2 April 1992
Resolved 2 April 1992
Deck/Cargo
Issued 10 May 1991 Resolved
PROVIDE SEAL FITTINGS FOR ALL CABLE ENTRANCES TO CRANE CONTROLLER & MOTOR.
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Electrical
Issued 10 May 1991 Resolved
SERVICE CO2 FOR GEN. ENG. SHUTDOWN.
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Documentation
Issued 26 March 1991 Resolved
REVISE ALL TRANSFER PROCEDURES TO INCLUDE VAPOR RECOVERY SYSTEM.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Documentation
Issued 25 October 1990 Resolved
PROVIDE OIL TRANSFER PROCEDURES CONTAINING DESRIPTION OF THE CAPOR COLLECTION SYSTEM, ETC. AS PER 46 CFR 155.750(D). THE VAPOR CONTROL SYSTEMSHALL NOT BE PUT INTO SERVICE UNTIL COMPLETED.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Deck/Cargo
Issued 3 April 1990 Resolved
REPLACE MISSING FLAME SCREEN TO BOWTHRUSTER AND MAIN DECK FUEL TANK VENTS.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Electrical
Issued 3 April 1990 Resolved
DEMONSTRATE OPERATION OF REVERSE POWER TRIPS TO #1 AND #2 GENERATORS.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Lifesaving
Issued 3 April 1990 Resolved
PERFORM ANNUAL INFLATABLE LIFERAFT SERVICING AT LIFERAFT SERVICING FACILITY(SERVICED TO SATISFACTION OF MARINE INSPECTOR). THIS VESSEL SHALL BE OPERATED UNMANNED UNTIL THIS SERVICING HAS BEEN PERFORMED.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Navigation
Issued 3 April 1990 Resolved
REMOVE OR REPAIR FORWARD 115V NAVIGATION LIGHTS.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Engineering
Issued 3 April 1990 Resolved
PROVIDE REMOTE CONTROL FOR BOW THRUSTER FUEL TANK VALVE. CONTROLS ARE TO BEOUTSIDE OF SPACE AND LABELED.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Electrical
Issued 3 April 1990 Resolved
REPLACE BATTERY CABLE CONNECTORS, WITH CRIMP OR SOLDER TYPE CONNECTORS.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Fire Fighting
Issued 3 April 1990 Resolved
REPAIR FIRE ALARM SYSTEM.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Deck/Cargo
Issued 3 April 1990 Resolved
PROVIDE NEW GASKET FOR OPEN GAUGING CLOSURE PLATE FOR TANKS 6P, 5P, 3P, AND3S.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Engineering
Issued 3 April 1990 Resolved
REPLACE MISSING INSULATION ON ALL DIESEL ENGINE EXHAUST IN WAY OF ELBOW FROM WATER JACKET.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Electrical
Issued 3 April 1990 Resolved
REPAIR SERVO MOTOR TO GOVERNOR ON #1 GENERATOR.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Electrical
Issued 21 April 1989 Resolved
INSTALL EXPLSION PROOF USCG APPROVED (EYS OR BICC) FITTINGS ON ALL ELECTRICAL CABLE ENTRANCES ON PORT & STARBOARD CARGO HOSE CRANES.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Documentation
Issued 25 July 1988 Resolved
AMEND THE VESSEL'S CERTIFICATE OF DOCUMENTATION TO REFLECT THE VESSEL'S NAME CHANGE.
Condition: Unknown
Due 25 July 1988
Resolved 25 July 1988
Construction/Loadline
Issued 13 May 1987 Resolved
MAKE PERMANENT REPAIRS TO INSET IN WAY OF TANK #5 PORT AT THE MAIN DECK AT NEXT DRYDOCK BUT NOT LATER THAN 30 APRIL 1988.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Electrical
Issued 18 April 1986 Resolved
PROVE PROPER OPERATION OF NUMBER THREE SHIP'S SERVICE GENERATOR TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 18 April 1986
Resolved 18 April 1986
Fire Fighting
Issued 11 October 1985 Resolved
PROVIDE 4 ADDITIONAL BII FIRE EXTINGUISHERS TO BRING TOTAL NUMBER ON BOARD TO 14 OR HAVE CERTIFICATE OF INSPECTION AMENDED.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Construction/Loadline
Issued 23 October 1984 Resolved
PROVIDE U.S. COAST GUARD APPROVED DRAWINGS ON THE BALLAST SYSTEM MODIFICATION. CONTACT MSO HAMPTON ROADS (804) 441- 3288 AS TO PROGRESS OF APPROVAL PRIOR TO 23 NOV 84.
Condition: Unknown
Due 23 October 1984
Resolved 23 October 1984

Ownership record