MAURY USCG vessel records
← All vessels

USL 477

Built
1971
Last inspected
22 August 2001
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 22 August 2001
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 19 calendar years (1981–2001)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-54244

Documentation record

Tonnage as PSIX records it1335 - Regulatory (Subpart C or D), Gross Ton
1335 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 39 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 8 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 39

22 August 2001 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1071967
7 August 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1068829
17 July 2000 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 820002
26 July 1999 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1106002
18 March 1999 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 810378
18 March 1999 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1131786
9 March 1999 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 807584
8 March 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 118564
7 August 1998 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1131672
22 August 1997 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1120516
19 August 1996 Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1086878
29 January 1996 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 86868
3 April 1995 Hull Examination · Examination of Repairs · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 848243
25 May 1994 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1457174
1 February 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 8361
1 December 1993 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 458811
6 July 1993 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 837439
16 April 1993 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1150878
30 November 1992 Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1149522
21 May 1992 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 948499
2 May 1991 Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1224245
15 January 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 919569
18 May 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1224255
22 February 1990 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 445961
10 March 1989 Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 894120
9 January 1989 Damage Survey · Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1041940
6 November 1988 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1202962
10 May 1988 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1197446
30 December 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 485080
1 October 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 510184
3 March 1987 Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1327679
15 December 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1333763
26 August 1986 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 438259
20 May 1986 Credit Drydock · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1304898
3 May 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1291284
25 March 1985 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1287466
6 March 1985 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 456551
27 April 1983 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 969563
5 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971427

Deficiency record · 6

Construction/Loadline
Issued 9 March 1999 Resolved
MAKE REPAIRS TO PORT BOW PUSH KNEE AND HULL. VESSEL NOT TO LOAD CARGO_x001C_ UNTIL REPAIRS HAVE BEEN INSPECTED TO THE SATISFACTION OF AN ATTENDING COASTGUARD MARINE INSPECTOR.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Construction/Loadline
Issued 9 January 1989 Resolved
DAMAGE IN WAY OF THE BOW RAKE AND I P/S WING VOID BOTTOM PLATE. DAMAGE WASREPAIRED WITH INSERTS 20'0"X14'6"X1/2" AND 3'0"X1'8"X1/2" IN THE BOW RAKE BOTTOM AND 17'0"X9'6"X3/8" IN THE WING VOID BOTTOM. ALL REPAIRS WERE AIR TESTED AND VISUALLY EXAMINED AND FOUND SATISFACTORY.
Condition: Unknown
Due 9 January 1989
Resolved 9 January 1989
Construction/Loadline
Issued 25 March 1985 Resolved
REMOVE LIQUID FROM #3 PORT WING VOID AND CHECK ADJACENT TANK FOR LEAKS.
Condition: Unknown
Due 25 March 1985
Resolved 25 March 1985
Construction/Loadline
Issued 25 March 1985 Resolved
WELD THE FOLLOWING: (1) 5" FRACTURE IN THE TOP WELD OF THE LOWER RUB PAD ON THE STARBOARD SIDESHELL AT THE STERN, AND (2) 3" FRACTURE IN THE TOP WELD OF THE LOWER RUB PAD ON THE PORT SIDESHELL AMIDSHIPS.
Condition: Unknown
Due 25 March 1985
Resolved 25 March 1985
Construction/Loadline
Issued 25 March 1985 Resolved
MAKE & MAINTAIN TEMPORARY REPAIRS TO THE FOLLOWING ITEMS WITH PERMANENT REPAIRS TO BE DONE BY COMPLIANCE DATE: (1) 2" HOLE IN STARBOARD BOW RAKE, (2) 18" "SPIDER WEB" FRACTURE JUST BELOW DECK KNUCKLE OF #2S WING VOID, & (3) 12" VERTICAL FRACTURE BELOW DECK KNUCKLE AT FWD BLKHD OF #1P WING VOID.
Condition: Unknown
Due 25 March 1985
Resolved 25 March 1985
Construction/Loadline
Issued 25 March 1985 Resolved
REPAINT ALL DRAFT MARKS.
Condition: Unknown
Due 25 March 1985
Resolved 25 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.