NO DOUBT

NO DOUBT is a 1980 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1982, most recently in May 2026, along with 150 deficiencies, 1 operational control and 1 casualty investigation in 2017.

Records from 1982 to 2026. Most recent: inspection, 14 May 2026.

Built
1980
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE3912
Flag
UNITED STATES
367345910, 368099180
Maury page id
psix-54250

Inspections, by type

…with no type recorded14
Years with a record 41 calendar years (1982–2026)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)52.4 ft × 18.3 ft × 7.0 ft
Registered tonnagegross 46 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROSE CREFT, INC. · HARKERS ISLAND, NC, UNITED STATES · built 1980
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 5 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
36 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN2340MMSI 367345910 · active · compulsorily equipped · granted 8 June 2022, expires 8 June 2032
WDK8969MMSI 368099180 · active · compulsorily equipped · granted 11 June 2019, expires 11 June 2029
WDE3912MMSI 367345910 · expired · compulsorily equipped · granted 29 March 2008, cancelled 2 June 2018
WDC9727MMSI 367105960 · expired · compulsorily equipped · granted 12 April 2006, cancelled 18 June 2016 · licensed under a name not among this hull’s recorded names (not shown)
WYR4435MMSI not assigned · expired · compulsorily equipped · granted 16 August 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 87

14 May 2026 Vessel Attendance · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8370836
3 September 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8205514
23 May 2024 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7917837
3 May 2024 Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7905999
9 August 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7782389
3 August 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7523904
26 May 2022 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7459760
24 February 2022 Hull Examination · Administrative Inspection · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7396855
3 August 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7029838
18 February 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6911502
13 May 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6686459
9 May 2018 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6404874
21 July 2017 Administrative Inspection · Internal Structural Exam · Damage Survey · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6216133
21 July 2017 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6220089
12 April 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6117701
8 February 2017 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6083310
28 March 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5840804
7 March 2016 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5828153
21 June 2012 Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 4357004
9 May 2012 Damage Survey · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4305530
8 September 2011 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4137328
14 July 2011 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 4082125
18 March 2010 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3696880
26 February 2010 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3686683
13 July 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3530184
1 November 2008 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 3363111
20 March 2008 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3163323
19 February 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3148213
14 February 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3147357
6 March 2007 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2882538
24 January 2007 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2861211
8 June 2006 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2813738
8 May 2006 Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2643556
14 February 2006 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2564080
4 April 2005 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2326034
29 April 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2058088
31 March 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2034521
3 March 2004 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2017389
29 April 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1804861
7 April 2003 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1770312
16 December 2002 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1719917
18 March 2002 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1752900
12 March 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1494479
6 November 2001 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1379626
23 May 2001 Type not recorded
No type recorded · CGC POINT LOBOS · USCG Heartland District (CGD-H) · Activity 1521149
12 September 2000 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1376318
16 October 1999 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1510055
16 September 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465513
22 February 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1351955
20 October 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1450206
19 May 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446658
4 May 1998 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1127727
19 November 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 642925
19 November 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1108051
18 September 1997 COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1433258
19 September 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1355955
7 May 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392455
19 September 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1377520
10 October 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1141483
22 September 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1407378
12 April 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1174053
29 March 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 864137
22 March 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 864135
12 April 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1142939
15 September 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1270547
1 September 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1263234
11 December 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 946390
26 September 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 946569
17 July 1991 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 941784
13 February 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1231230
7 November 1990 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1214900
12 September 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 922955
21 February 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1231105
6 September 1989 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1044868
16 November 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 894995
14 September 1988 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1044910
28 September 1987 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1321898
10 March 1987 Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1020901
18 November 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1330836
5 November 1985 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 994020
24 September 1985 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1299749
5 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1286530
13 April 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973594
15 December 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973560
15 December 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 981910
22 September 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279724
30 August 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 965943

Deficiency record · 150

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 September 2025 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. MI observed the life floats, to include its paddles, not in a serviceable condition. 01 lifefloat had sun faded net cordage attachment points that were breaking off and lines were not serviceable; breaking under tension from excessive wear. Other life float had cracked fiberglass in multiple locations, compromising its watertight integrity. 46 CFR 185.700(a)
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 September 2025
Resolution: Attending MI observed operator procured new life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 September 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed the life ring on board to have holes in it exposing the interior foam compromising its watertight integrity and associated light not have a battery present preventing it from being in an operational and ready condition. 46 CFR 176.808 (b)
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 12 September 2025
Resolution: Attending MI observed operator procured new life ring and life ring light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI observed an incorrect number of life jackets stored on board the vessel. Operator had spares available on shore to restore amount to amount specified on the COI. 46 CFR 180.71 (a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 3 September 2025
Resolution: Vessel operator procured spare lifejackets from shore storage.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 September 2025 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. MI observed multiple leads secured with alligator clips not permanently secured to battery terminals. 46 CFR 183.350 (d)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 12 September 2025
Resolution: Attending MI observed no alligator clips and less battery terminal connections than what was observed prior.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 September 2025 Resolved
The intent of this part is to ensure the main propulsion machinery and the auxiliary machinery is suitable for for the purpose intended. MI observed the port rudder post to be leaking a steady stream of water. 46 CFR 182.1-5 (Old-T)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 12 September 2025
Resolution: Rudder post was repacked and sea trial conducted, no leak observed.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 3 September 2025 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: 2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. MI observed the visual alarm indicator for the aft steering compartment high water level alarm to be inoperable. 46 CFR 182.530(a)
Action required: 30 - Ship detained
Resolved 12 September 2025
Resolution: Visual light for alarm was operable.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 3 September 2025 Resolved
For fixed-gas fire extinguishing systems, the inspection and tests required by table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. MI observed the engine interlock to be inoperable. 46 CFR 176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2025
Resolution: Operator had 3rd party servicing diagnose and fixed issue, attending MI conducted SAT op test of interlock.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 September 2025 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. MI observed vessel operators unable to provide drills logbook and maintenance records. 46 CFR 185.420(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 September 2025
Resolution: MI observed SAT logs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2024 Resolved
A passenger accommodation space must be maintained to minimize fire and safety hazards At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine Inspector noted loose gear about the decks, presenting an unsafe condition. Remove or stow the gear.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2024
Resolution: Loose gear was removed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 May 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate high water levels. Marine inspector noted bilge high level alarms inoperable. Repair the alarms.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2024
Resolution: High bilge level alarms were repaired.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 May 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Marine Inspector noted the bilge pump indicators were mislabeled and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2024
Resolution: Bilge pump indicator lights were repaired.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 May 2024 Resolved
A passenger accommodation space must be maintained to minimize fire and safety hazards. Marine Inspector noted bunk support broken, leading to the inability to access the emergency escape hatch.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2024
Resolution: Wooden support structures repaired.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 28 May 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Marine Inspector noted the vessel not fitted with required smoke detectors. Install the detectors
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2024
Resolution: Required detectors were installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 May 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Marine Inspector noted starboard navigation light inoperable, and with a loose lens. Repair the light.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2024
Resolution: Bulb replaced and lens tightened.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 28 May 2024 Resolved
All electrical installations shall be to the satisfaction of the OCMI. Marine inspector noted 2 missing or loose breaker covers in the salon, loose wires on the bridge, and bare wires in the accommodation space in each bunk. Replace the covers and remove or cover bare wires.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2024
Resolution: braker covers secured, loose wires on bridge removed, bare wires in accommodation placed into appropriate terminations.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 May 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Marine Inspector was informed by vessel rep that a repair was made to decking over the port engine with no USCG oversight.
Action required: 705 - Other - as specified
Resolved 28 May 2024
Resolution: Credit dry-dock was given,during the inspection the deck repair was inspected. Decking appears to be in-kind to what was originally there.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 June 2022 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation. Shaft seals and rudder posts leaking excessively. Provide evidence of corrected water ingress. (cleared 08JUN22)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: Provided video of corrected water ingress.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 June 2022 Resolved
A vessel must comply with the applicable requirements for any radio installations. FCC radio telephony and station license not onboard. Both need to be located or newly issued to include the correct MMSI number to correlate with the documentation. (cleared 08JUN22)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: Vessel located FCC certificates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 June 2022 Resolved
The shutoff valve at the tank must be manually operable from outside the compartment which the valve is located. Shutoff valve T-handle was kept in engine compartment, preventing use in an engine room fire. Relocate handle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Photo evidence received, see documents tab.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2022 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies. Run drills including relocated T-handle and improved provisions for man overboard. Show log entry.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Drills run, log entry shown. See docs.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 June 2022 Resolved
Each distribution panel must be protected from falling debris and dripping or splashing water. A/C breaker panel missing front cover. Replace front cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Photo of replaced cover received, see docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 June 2022 Resolved
On a nonmetallic vessel, equipment must be bonded together to a common ground. Bonding system painted over at connections. Remove paint.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Photos of bonding without paint received, see docs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2022 Resolved
Each vessel must be equipped with a portable light accessible at the access to the propulsion machinery space. No portable light present. Provide proof of portable light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Portable light provided, see docs.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 June 2022 Resolved
Provisions must be made for for closing all supply ducts cowls or scoops for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vent on engine room door has no closure mechanism. Provide proof of closure mechanism.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2022
Resolved 22 June 2022
Resolution: cover to cut off airflow created. See photo in docs tab.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 June 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Wiring behind pilothouse console found burned. Provide proof of replaced burned wiring.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2022
Resolved 21 June 2022
Resolution: Wires repaired, see docs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 June 2022 Resolved
Vessel shall not operate as a small passenger vessel for hire until inspected by the cognizant OCMI and issued an valid Certificate of Inspection. Vessel is not in complacence with sub-chapter T or C requirements.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: Vessel was issued temp COI.
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 26 May 2022 Resolved
All electrical equipment and circuits must be clearly marked and identified. Breaker panels unlabeled. Label all breaker panels.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 21 June 2022
Resolution: Breaker panel labeled, see docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2020 Resolved
Secure engine room starboard racor filters.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2020
Resolved 2 October 2020
Resolution: Owner provided Engine room air intake covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2020 Resolved
Secure stbd engine stop solenoid.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2020
Resolved 2 October 2020
Resolution: Stbd Engine racor filter properly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020 Resolved
Remove deck receptacles that are not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2020
Resolved 2 October 2020
Resolution: Deck receptacles removed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 August 2020 Resolved
Correct Navigation light configuration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2020
Resolved 2 October 2020
Resolution: Nav lights properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 August 2020 Resolved
Renew life float line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2020
Resolved 2 October 2020
Resolution: Life float line renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 May 2019 Resolved
Provide proof of valid COD.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 29 May 2019
Resolution: Received proof of valid COD.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2019 Resolved
Provide proof of valid FCC Station License.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 11 June 2019
Resolution: Received proof of valid FCC license.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 May 2019 Resolved
Provide up to date Light List, Coast Pilot and local notice to mariners.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 29 May 2019
Resolution: Received proof of updated Light list and local notice to mariners.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 8 November 2017 Resolved
Vessel needs to have the stbd engine wet exhaust repaired of a leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 17 November 2017
Resolution: Repaired.
Construction/Loadline › Hull › Stringer
Issued 28 September 2017 Resolved
Clean the wooded stringers of angle hair, in the 4 locations discussed durring exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 8 November 2017
Resolution: Cleaned
Operations/Management › Vessel Activity › Underway
Issued 28 September 2017 Resolved
Have vessel underway to verify repairs prior to Hull credit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 8 November 2017
Resolution: Witnessed
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 28 September 2017 Resolved
Remove old grounding wires from steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 8 November 2017
Construction/Loadline › Structures › Superstructure
Issued 21 July 2017 Resolved
Repair Bow and Deck hand rail on the Bow.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 17 November 2017
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 21 July 2017 Resolved
Provide an Anchor and Anchor line for vessel.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 8 November 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 21 July 2017 Resolved
Conduct a DAPI Audit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 8 November 2017
Operations/Management › Vessel Activity › Underway
Issued 21 July 2017 Resolved
Conduct anchor drill while underway.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 8 November 2017
Operations/Management › Vessel Activity › Underway
Issued 21 July 2017 Resolved
Vessel will need to get underway with marine inspector to check engines and for vibration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 8 November 2017
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 April 2017 Resolved
Provide a valid COD for the vessel.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2017
Resolved 21 April 2017
Engineering › Fuel Oil Service System › Filter
Issued 12 April 2017 Resolved
Provide proper fuel oil filters for the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 21 April 2017
Electrical › Electric Supply System (service) › Cable
Issued 12 April 2017 Resolved
Remove non-approved AC power cord from the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 21 April 2017
Communications › Radio Communications › EPIRB
Issued 28 March 2016 Resolved
Provide EPIRB for vessel.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 28 March 2016
Resolution: onboard
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 March 2016 Resolved
provide First aid kit for vessel.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 28 March 2016
Resolution: provided
Engineering › Bilge Water Management System › Interface Detector
Issued 28 March 2016 Resolved
high water visual alarm for FWD space on vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 3 August 2016
Resolution: The visual alarm was fixed.
Fire Fighting › Fire Bucket › Availability
Issued 28 March 2016 Resolved
provide 3 fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2016
Resolved 28 March 2016
Resolution: provided
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 28 March 2016 Resolved
provide HERTZ gauage for Generator on vessel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 3 August 2016
Resolution: HERTZ gauge on generator was fixed.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 28 March 2016 Resolved
[name withheld] jackets with name of vessel, along with life ring,life float oars.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 30 March 2016
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2012 Resolved
Planking on Strb side engine room 6-8 planks above the garboard and under the floor beam were wasted and leaking sea water.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2012
Resolution: Planking had been replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 May 2012 Resolved
Electrical wiring not supported every 24 inches with support clips
Condition: Improper/Lack of Maintenance
Due 23 May 2012
Resolved 24 May 2012
Resolution: Electrical clip in place
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 9 May 2012 Resolved
Heat exchanger was leaking raw water
Condition: Improper/Lack of Maintenance
Due 23 May 2012
Resolved 24 May 2012
Resolution: Heat exchanger/muffler repair and installed
Construction/Loadline › Penetrations › Valve Flange
Issued 18 March 2010 Resolved
Renew/fix broken handle for valve located port side of centerline in engine compartment (capped off valve) in accordance with 46 CFR 176.25-5 to the satisfaction of the attending marine inspector.
Due 23 April 2010
Resolved 30 March 2010
Construction/Loadline › Structures › Superstructure
Issued 18 March 2010 Resolved
Renew knee, port side, 6th frame in engine compartment in accordance with 46 CFR 176.25-5 to the satisfaction of the attending marine inspector.
Due 23 April 2010
Resolved 30 March 2010
Accommodation/Occupational Safety › Ventilation › General
Issued 18 March 2010 Resolved
Renew vent to engine room, port side of accommodation space in accordance with 46 CFR 182.20-45 to the satisfaction of the attending marine inspector.
Due 23 April 2010
Resolved 30 March 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 March 2010 Resolved
Renew top of side rail, port side, of ladder leading to pilot house in accordance with 177.35 to the satisfaction of the attending marine inspector.
Due 23 April 2010
Resolved 30 March 2010
Construction/Loadline › Hull › Hull Plating
Issued 18 March 2010 Resolved
Renew/seal strip planking, starboard side imbetween bays 12 and 13 just below the chine in accordance with 46 CFR 176.25-5 to the satisfaction of the attending marine inspector.
Due 23 April 2010
Resolved 30 March 2010
Construction/Loadline › Hull › Hull Plating
Issued 18 March 2010 Resolved
Renew strip planking imbetween bay 2 and 3 starboard side above the chine in accordance with 46 CFR 176.25-5 to the satisfaction of the attending marine inspector.
Due 23 April 2010
Resolved 30 March 2010
Construction/Loadline › Hull › Strut/Cross Tie
Issued 18 March 2010 Resolved
Renew/Replace bolts on starboard side, bays 2 and 3 for the knees in the engine compartment in accordance with 46 CFR 176.25-5 to the satisfaction of the attending marine inspector.
Due 23 April 2010
Resolved 30 March 2010
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 March 2010 Resolved
Check and renew any defective floor frame to side frame connection bolts throughout the vessel in accordance with 46 CFR 176.25-5 to the satisfaction of the attending marine inspector.
Due 23 April 2010
Resolved 30 March 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 March 2010 Resolved
Repair top rail, main deck in way of deck rail connection and prove tightness of main deck in accordance with 46 CFR 176.25-5 to the satisfaction of the attending marine inspector.
Due 23 April 2010
Resolved 30 March 2010
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 18 March 2010 Resolved
Conduct sea trial in presence of the attending marine inspector.
Due 23 April 2010
Resolved 30 March 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 February 2010 Resolved
Vessel exceeded drydock date listed on the vessel's Certificate of Inspection. A drydock, and internal structural examination shall be completed prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2010
Resolution: Credit drydock and internal structural examination completed under activity # 3696880
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 July 2009 Resolved
Remove conductors from fuel lines.
Due 13 August 2009
Resolved 19 August 2009
Construction/Loadline › Penetrations › Valve Flange
Issued 13 July 2009 Resolved
Provide positive closure for portside thru-hull.
Due 13 August 2009
Resolved 19 August 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 July 2009 Resolved
Properly splice battery cables to switchover (well pump-portside).
Due 13 August 2009
Resolved 19 August 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 July 2009 Resolved
Provide insulation for starboard and port outboard exhausts.
Due 13 August 2009
Resolved 19 August 2009
Construction/Loadline › Penetrations › Valve Flange
Issued 13 July 2009 Resolved
Free raw water valves for main diesel engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2009
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 13 July 2009 Resolved
Replace wasted rubber hose on sewage overboard.
Due 13 August 2009
Resolved 19 August 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 13 July 2009 Resolved
Reservice portables IAW NFPA 10/46CFR176.810.
Due 13 August 2009
Resolved 19 August 2009
Construction/Loadline › Structures › Manhole
Issued 13 July 2009 Resolved
Make forward escape hatch operable from both sides.
Due 13 August 2009
Resolved 19 August 2009
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 13 July 2009 Resolved
Repair bilge alarms and make audible and visual alarms available at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2009
Communications › Radio Communications › EPIRB
Issued 13 July 2009 Resolved
Renew hydro-static release on EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2009
Communications › Radio Communications › EPIRB
Issued 13 July 2009 Resolved
Renew EPIRB registration and battery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2009
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 13 July 2009 Resolved
Re-align starboard shaft and provide measurements from shaft coupling to shaft log.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2009
Documentation › Certificates/Documents › FCC SSL
Issued 20 March 2008 Resolved
Provide FCC safety certificate, and FCC marine radio operator permit.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 March 2008 Resolved
Replace/Repair starboard navigation light, and lens.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Documentation › Logs/Records › Logbook (official)
Issued 20 March 2008 Resolved
Provide current training log book.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 20 March 2008 Resolved
Provide emergency brodcast placard.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 20 March 2008 Resolved
Provide annual certification for fire fighting systems.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Communications › Radio Communications › EPIRB
Issued 20 March 2008 Resolved
Provide hydrostatic expiration date for EPIRB.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Engineering › Electric Propulsion System › Battery
Issued 20 March 2008 Resolved
Provide protective covering for batteries.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Lifesaving › Lifefloat › Paddle
Issued 20 March 2008 Resolved
Label paddles with vessel's name on life float.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 March 2008 Resolved
Replace float light for life float.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Lifesaving › Lifefloat › Lifeline
Issued 20 March 2008 Resolved
Reattach life line, and mount for life float.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Lifesaving › Lifefloat › Serviceable
Issued 20 March 2008 Resolved
Replace life float.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Construction/Loadline › Structures › Scuttle
Issued 20 March 2008 Resolved
Repair emergency escape hatch.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 March 2008 Resolved
Repair retroreflective tape on 7 life jackets.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 20 March 2008 Resolved
Replace 1 type I life preserver.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Construction/Loadline › Structures › Scuttle
Issued 20 March 2008 Resolved
Remove obstructions from forward escape hatch.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 20 March 2008 Resolved
Replace smoke alarm for accomodation space.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Construction/Loadline › Penetrations › Bottom Plug
Issued 20 March 2008 Resolved
Cap thru hull on starboard side in engine room.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 20 March 2008 Resolved
Provide drug testing program paperwork.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 May 2006 Resolved
Provide 04 Adult Type I PFD's in serviceable condition approved under 46 CFR 160.055 in accordance with 46 CFR 180.71 and marked in accordance with 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 8 May 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 May 2006 Resolved
Provide current copies or excerpts from navigation safety publications and a currently corrected navigational chart for area of intended operations as required by 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 8 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2006 Resolved
Make wiring joints and splices in power and lighting circuits (less than 50 volts) mechanically secure (taped) and stowed in suitable junction boxes as required by 46 CFR 183.05-50.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 8 June 2006
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2006 Resolved
Remove marine bore damage in way of starboard strut and area in way of starboard shaft hull penetratation to the satisfaction of the attending marine inspector in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 14 March 2006
Resolved 15 February 2006
Resolution: Burned out borers and used marine grade epoxy to fill effected area
Construction/Loadline › Penetrations › Valve Flange
Issued 14 February 2006 Resolved
Renew live well through hull valve to the satisfaction of the attending marine inspector in accodance with 46 CFR 179.350.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 15 February 2006
Resolution: Through hull replaced and found satisfactory.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 4 April 2005 Resolved
Obtain 2005 tide and current tables for area of operation.
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 29 April 2005
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 4 April 2005 Resolved
Repair and prove vessels whistle.
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 29 April 2005
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 4 April 2005 Resolved
Provide Emergency Lighting.
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 29 April 2005
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 April 2005 Resolved
Properly label bilge alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 29 April 2005
Navigation › Piloting/Steering
Issued 31 March 2004 Resolved
Provide navigation publications as required by 46 CFR 184.420 LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 29 April 2004
Resolution: Owner provided up to date nav pubs.
Communications › Radio Communications
Issued 31 March 2004 Resolved
Replace EPIRB battery IAW 46 CFR 185.726(d) LEGACY COMPONENT DESC: EPIRB
Due 30 April 2004
Resolved 31 March 2004
Resolution: Owner replaced EPIRB battery.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 7 April 2003 Resolved
Provide servicing of Fixed Fire System and portable extinguishers as required by 46 CFR 176.810. LEGACY COMPONENT DESC: Quantity of CO2
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2003
Resolved 9 April 2003
Resolution: Examined, found sat.
Navigation › Piloting/Steering
Issued 7 April 2003 Resolved
Provide Charts and Publications as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 7 May 2003
Resolved 29 April 2003
Resolution: Owner provided charts and pubs.
Communications › Radio Communications
Issued 7 April 2003 Resolved
Provide Emergency Broadcast Placard as required by 46 CFR 184.506. LEGACY COMPONENT DESC: VFH Radiotelephone
Action required: 705 - Other - as specified
Due 7 May 2003
Resolved 29 April 2003
Resolution: Owner provided Emergency broadcast placard.
Communications › Alarms/Indicators
Issued 7 April 2003 Resolved
Repair High level bilge alarm(forepeak) as required by 46 CFR 182.530. LEGACY COMPONENT DESC: High Water Alarm
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2003
Resolved 7 April 2003
Resolution: Examined, found satisfactory.
Electrical › Electric Generation Source (service)
Issued 7 April 2003 Resolved
Provide voltmeter, ampmeter and frequency meter operational tests as required by 46 CFR 183.10-5(g). LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 7 May 2003
Resolved 29 April 2003
Resolution: Owner provided voltmeter, ampmeter and frequency meter operational tests.
Lifesaving › Buoyant Apparatus
Issued 7 April 2003 Resolved
Provide proper stowage of Lifefloat as required by 46 CFR 186.266.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2003
Resolved 9 April 2003
Resolution: Examined, found satisfactory.
Lifesaving › Buoyant Apparatus
Issued 7 April 2003 Resolved
Replace line on lifefloat as required by 46 CFR 180.175. LEGACY COMPONENT DESC: Line
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2003
Resolved 9 April 2003
Resolution: Examined, found satisfactory.
Construction/Loadline › Penetrations
Issued 12 March 2002 Resolved
Renew washdown pump valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 18 March 2002
Resolution: Owner renewed washdown pump valve.
Construction/Loadline › Hull
Issued 12 March 2002 Resolved
Sister fractured frames portside bow #3,4,5, 12 inches below the sheerstrake. Sister 12 inches above and below the fracture. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 18 March 2002
Resolution: Owner sistered three frames port and one fram stbd. numbers 3, 4, 5 port and number 2 stbd from the stem.
Construction/Loadline › Hull
Issued 12 March 2002 Resolved
Schedule sea trial prior to credit hull.
Action required: 705 - Other - as specified
Due 12 April 2002
Resolved 3 April 2002
Resolution: 03 Apr 02- Revisited vessel for Def check and sea trial. Completed underway operational seatrial for wood vessel. Observed no leaking or unusual working of planks or structual members. Issued Hull credit.
Construction/Loadline
Issued 19 May 1998 Resolved
REPAIR AS NEEDED ROTTED FUTTOCK TWO FROM OUTSIDE ON STARBOARD SIDE OF STERN.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Documentation
Issued 19 November 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Electrical
Issued 19 September 1996 Resolved
RENEW ELECTRICAL BREAKER PANEL INDEX FOR PANEL LOCATED IN MAIN CABIN.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Lifesaving
Issued 19 September 1996 Resolved
PROVIDE PROOF OF REQUIRED CREW EMERGENCY DRILL TRAING AND REQUIRED TRAININGLOG AS PER 46 CFR 185.520 & 185.524
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Lifesaving
Issued 22 September 1994 Resolved
PROVIDE 60 FT LINE FOR RING BUOY AND PROPERLY INSTALL WATERLIGHT LINE.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Engineering
Issued 22 September 1994 Resolved
RENEW HOSE CLAMP AND BONDING STRAP ON PORT FUEL TANK FILL.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Navigation
Issued 22 September 1994 Resolved
RAISE ANCHOR LIGHT SO THAT VISABILITY IS 360 DEGREES.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Navigation
Issued 22 September 1994 Resolved
UPGRADE MASTHEAD LIGHT IAW 72 COLREGS.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Engineering
Issued 22 September 1994 Resolved
INSTALL 30X30 MESH SCREEN ON PORT FUEL TANK VENT.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Engineering
Issued 22 September 1994 Resolved
REMOVE PETCOCK VALVE FROM FUEL STRAINER BOWL.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Electrical
Issued 22 September 1994 Resolved
PROVIDE TERMINMAL COVER FOR GENERATOR BATTERY.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Accommodation/Occupational Safety
Issued 22 September 1994 Resolved
PROVIDE LOCKING DEVICE FOR MSD OVERBOARD VALVE.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Engineering
Issued 29 March 1994 Resolved
CONDUCT U/W OPERATIONAL SEA TRIAL INCLUDING GENERATOR OPERATION UNDER LOAD TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 April 1994
Resolved 8 July 1994
Accommodation/Occupational Safety
Issued 17 July 1991 Resolved
REMOVE TINT FROM WINDOWS IN PILOT HOUSE.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Navigation
Issued 12 September 1990 Resolved
PROVIDE PERMANENT REPAIRS TO PORT EXHAUST MUFFLER
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990 Resolved
SECURE FUEL SUMPS TO VESSELS HULL
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990 Resolved
INSTALL HEAT SHIELD TO TACOR FUEL FILTER
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990 Resolved
RENEW AND RESTRAP PORT MDE RAW WATER SUCTION HOSE
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990 Resolved
REPAIR OIL LEAK TO PORT MDE
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990 Resolved
TIGHTEN GENERATOR THROUGH HULL FITTING
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Electrical
Issued 12 September 1990 Resolved
REPAIR OR REPLACE VESSELS HORN
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990 Resolved
DOUBLE HOSE CLAMP TO MSE DISCHARGE LINE
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Accommodation/Occupational Safety
Issued 12 September 1990 Resolved
PROPERLY SECURE BATTERY BOXES AND REPAIR BATTERY BOX COVERS
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Unknown
Issued 6 September 1989 Resolved
PROVIDE ADDITIONAL RETRO-REFLECTIVE TAPE FOR 4(FOUR) CHILD PFD'S.
Condition: Unknown
Due 6 September 1989
Resolved 6 September 1989
Unknown
Issued 6 September 1989 Resolved
PROVIDE ADEQUATE LENGTH OF DISCHARGE HOSE FOR HAND BILGE PUMP.
Condition: Unknown
Due 6 September 1989
Resolved 6 September 1989
Construction/Loadline
Issued 18 November 1986 Resolved
REPLACE FLEXIBLE PIPING TO AFT ELECTRIC BILGE PUMP WITH RIGID TYPE PIPING.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Electrical
Issued 18 November 1986 Resolved
DE-RATE 12 KW ONAN GENERATOR BY REPLACING 60 AMP BREAKER WITH 50 AMP BREAKER @ MAIN BREAKER ABOVE GENERATOR IAW 46CFR183.10-50. ALSO PROVIDE ADDITIONAL NAMEPLATE SHOWING DATE DERATED AND NEW CIRCUIT BREAKER SIZE. PROVIDE LOAD TEST OF GENERATOR AFTER DERATING.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Accommodation/Occupational Safety
Issued 18 November 1986 Resolved
PROVIDE FLAME SCREEN FOR MSD VENT.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Lifesaving
Issued 18 November 1986 Resolved
RENEW LIFEFLOAT WATERLIGHT LINE(18').
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Fire Fighting
Issued 18 November 1986 Resolved
RE-CHARGE TWO(02) PORTABLE DC FIRE EXTINGUISHERS.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Fire Fighting
Issued 18 November 1986 Resolved
MOUNT PORTABLE FIRE EXTINGUISHER IN BERTHING AREA.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Construction/Loadline
Issued 18 November 1986 Resolved
PROPERLY LABEL:(1) LIFEFLOAT PADDLES - VESSEL NAME(2) FORWARD EMERGENCY ESCAPE-EMERGENCY EXIT-KEEP CLEAR, 1" LETTER(3) REMOTE FUEL SHUTOFF VALVES, 1" LETTERS.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986

Casualty record · 1

21 July 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6220089
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.