MAURY USCG vessel records
← All vessels

OU 751

OU 751 is a 1982 freight barge. The Coast Guard has recorded 23 inspections since 1982, most recently in January 2000, along with 9 deficiencies.

Records from 1982 to 2000. Most recent: inspection, 26 January 2000.

Built
1982
Last inspected
26 January 2000
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 26 January 2000
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 16 calendar years (1982–2000)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-54252

Documentation record

Tonnage as PSIX records it867 - Convention (Subpart B), Gross Ton
260 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

26 January 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1045674
21 December 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 808769
10 August 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 782124
24 January 1995 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1135606
6 December 1994 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 830364
6 December 1993 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1159032
20 April 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 642058
9 March 1993 Re-Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1146045
4 December 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1253879
24 June 1991 Deficiency Check · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1250188
22 December 1990 Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1225273
12 January 1990 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 980321
20 April 1989 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1199024
20 April 1989 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1200582
31 March 1988 COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1195814
30 September 1987 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1317326
23 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329529
29 January 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997627
12 November 1985 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301692
28 June 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986254
9 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280637
31 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271110
3 November 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272722

Deficiency record · 9

Construction/Loadline
Issued 22 December 1990 Resolved
CROP AND RENEW AS ORIGINAL 3 GUSSETS AT AFT BULKHEAD IN #3 STBD WING TANK VOID, CROP AND RENEW AS ORIGINAL BAD METAL AS MARKED.
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Construction/Loadline
Issued 22 December 1990 Resolved
CROP AND RENEW AS ORIGINAL 2 GUSSETS AS MARKED IN #4 STBD WING TANK VOID._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Construction/Loadline
Issued 22 December 1990 Resolved
CROP AND RENEW AS ORIGINAL 2 GUSSETS AT THE TOP OF THE AFT BULKHEAD IN #1 STBD WING TANK VOID.
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Construction/Loadline
Issued 22 December 1990 Resolved
REMOVE ALL CEMENT AND MAKE ALL CENTER VOIDS AVAILABLE FOR U.S. COAST GUARD_x001C_INSPECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Construction/Loadline
Issued 22 December 1990 Resolved
REMOVE DOUBLERS IN #1 - 5 PORT AND STBD WING TANK VOIDS IN WAY OF LONGITUDINAL BULKHEADS AND INSERT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Construction/Loadline
Issued 22 December 1990 Resolved
CROP AND RENEW AS ORIGINAL BAD METAL AT FORWARD BULKHEAD AS MARKED IN #4 PORT WING TANK VOID_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Construction/Loadline
Issued 22 December 1990 Resolved
CROP AND RENEW AS ORIGINAL 1 GUSSET AS MARKED IN #3 PORT WING TANK VOID_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Construction/Loadline
Issued 22 December 1990 Resolved
CROP AND RENEW AS ORIGINAL 5 GUSSETS AS MARKED IN #2 PORT WING TANK VOID._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990
Construction/Loadline
Issued 22 December 1990 Resolved
CROP AND RENEW AS ORIGINAL 2 GUSSETS AS MARKED IN #1 PORT WING TANK VOID_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 December 1990
Resolved 22 December 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.