Records from 1982 to 1990. Most recent: inspection, 8 February 1990.
Documentation record
Registered dimensions (L × B × D)169.8 ft × 40.0 ft × 13.6 ft
Registered tonnagegross 296 / net 201
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderQUALITY SHIPYARDS, INC. · HOUMA, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 27 October 1982
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it296 - Regulatory (Subpart C or D), Gross Ton
201 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
8 February 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1216388
26 September 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891930
13 August 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000778
13 August 1987
Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000934
28 January 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015510
11 November 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327169
27 July 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1290011
20 July 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1290010
25 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301985
1 November 1984
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 976442
27 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273903
Fire Fighting
Issued 26 September 1988
Resolved
PROVIDE A FIXED FIRE EXTINGUISHING SYSTEM OR EQUIVALENT FOR GRADE "E" MUD TANK TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 26 September 1988
Resolved 26 September 1988
Unknown
Issued 26 September 1988
Resolved
PROVE ALL HIGH PRESSURE CYLINDERS ON BOARD MEET THE REQUIREMENTS OF 46 CFR 147.60(A) (1) AND (2) OR THE WAIVER GRANTED BY G-MTH-1 IN LETTER 16703/46 CFR 147 DATED 28 JULY 1988.
Condition: Unknown
Due 31 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 26 September 1988
Resolved
SERVICE LIFERAFTS AND HYDROSTATIC RELEASES TO THE SATISFACTIONOF THE COGNIZANT OCMI.
Condition: Unknown
Due 30 November 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 11 November 1986
Resolved
REPAIR SYNCHRO SPEED MOTOR ON PORT GENERATOR.
Condition: Unknown
Due 11 November 1986
Resolved 11 November 1986
Engineering
Issued 11 November 1986
Resolved
PROVE PROPER OPERATION OF BILGE ALARM SYSTEM.
Condition: Unknown
Due 11 November 1986
Resolved 11 November 1986
Electrical
Issued 11 November 1986
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP AND REVERSE POWER RELAY FOR STAR- BOARD GENERATOR.
Condition: Unknown
Due 11 November 1986
Resolved 11 November 1986
Engineering
Issued 11 November 1986
Resolved
MAKE REPAIRS TO FUEL OIL DAY TANK SIGHT GLASS.
Condition: Unknown
Due 11 November 1986
Resolved 11 November 1986
Navigation
Issued 27 July 1985
Resolved
PROVIDE 1 LICENSED MATE, 1 LICENSED CHIEF ENGINEER, 2 ABLE SEAMEN AND 1 ORDINARY SEAMAN PRIOR TO DEPARTURE PORT OF DUBAI.
Condition: Unknown
Due 27 July 1985
Resolved 27 July 1985
Lifesaving
Issued 27 July 1985
Resolved
SERVICE SWITLIK INFLATABLE LIFERAFT AT AN AUTHORIZED FACILITY NO LATER THAN180 DAYS FROM 27 JULY 1985.
Condition: Unknown
Due 27 July 1985
Resolved 27 July 1985
Unknown
Issued 1 November 1984
Resolved
REPLACE THE MISSING SANITARY PUMP.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
REPAIR SPEED CONTROLS AND TEST THE REVERSE POWER RELAYS FOR BOTH SHIP SERVICE GENERATORS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
TEST OVERSPEED TRIPS ON BOTH SHIP SERVICE GENERATORS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
REPLACE PRESSURE GUAGES TO BOTH MAIN STARTING AIR RECEIVERS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
MAKE AVAILABLE ALL BULK CEMENT TANKS FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
PROVIDE THIS OFFICE WITH A LETTER OR TELEX REQUESTING THE DRYDOCK EXTENSIONINCLUDING THE LENGTH OF EXTENSION REQUESTED. THIS MUST BE COMPLETED PRIOR TO ISSUANCE OF THE EXTENSION.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
REPLACE THE 15 POUND CO2 BOTTLE FOR THE PAINT LOCKER FIXED CO2 SYSTEM.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
REFILL THE SPARE CYLINDER TO THE SELF-CONTAINED BREATHING APPARATUS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
REPAIR THE SECOND RADAR.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
REPLACE LIGHTS FOR ALL PERSONAL FLOTATION DEVICES (PFD).
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
HAVE BOTH INFLATIBLE LIFERAFTS SERVICED AT A COAST GUARD APPROVED FACILITY.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
PROVIDE ONE ADDITIONAL 50 FOOT LENGTH OF FIRE HOSE.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
HAVE BOTH LIFERAFT HYDROSTATIC RELEASES SERVICED AT A COAST GUARD APPROVED FACILITY.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984