Records from 1984 to 2024. Most recent: inspection, 29 May 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 69
29 May 2024
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7922096
31 October 2022
Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 7587879
15 April 2005
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2328109
15 January 2004
Annual Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1986006
2 December 2003
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1954305
30 January 2003
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1737598
15 January 2003
COI Inspection · Administrative Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1727167
28 June 2002
Excursion Permit
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1638544
2 May 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1611660
1 May 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1611716
17 April 2002
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1601637
28 November 2001
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1076861
14 March 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1060501
7 March 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1440451
23 February 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 816183
15 February 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1046615
21 January 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048073
21 January 2000
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369498
6 December 1999
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1433546
7 May 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369114
16 April 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 790262
4 February 1999
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1404686
30 June 1998
Excursion Permit
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1128032
19 December 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1116292
20 November 1997
Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378208
2 July 1997
Excursion Permit
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1115967
12 February 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359354
14 January 1997
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1385875
23 August 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1087296
29 June 1996
Excursion Permit
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1248135
10 June 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1409506
5 June 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359151
30 May 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380518
10 May 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363614
1 May 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355784
25 April 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1394531
12 March 1996
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357514
6 February 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1187334
21 March 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374225
6 January 1995
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358647
16 November 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1392110
15 April 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1431360
4 March 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1425419
17 February 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1444804
21 January 1994
MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391949
20 May 1993
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 830065
11 May 1993
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1138153
2 March 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 953591
20 February 1992
Re-Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1420638
21 November 1991
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 941217
1 March 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 929778
5 February 1991
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 921890
1 August 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1219446
25 May 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1224351
11 May 1990
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235137
8 February 1989
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1034568
7 February 1989
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1032873
13 April 1988
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1041245
10 March 1988
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1336982
19 February 1988
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1026384
26 March 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1327438
6 March 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1010977
10 February 1987
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1002895
27 March 1986
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1306139
27 February 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1292575
7 January 1986
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 996592
26 April 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1290435
27 February 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 978860
10 December 1984
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1285212
Construction/Loadline › Structures › Deck Plating
Issued 15 April 2005
Resolved
Provide rigging report
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2005
Construction/Loadline › Hull › Hull Plating
Issued 15 April 2005
Resolved
Replace stressed wood in stbd ama (aft section)
Condition: Unknown
Due 30 December 2005
Resolved 1 October 2007
Resolution: Vessel deactivated
Construction/Loadline › Penetrations › Gasket
Issued 15 April 2005
Resolved
Replace all broken windows.
Condition: Unknown
Due 2 May 2005
Resolved 3 May 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 April 2005
Resolved
Replace exhaust hose for engine.
Condition: Unknown
Due 2 May 2005
Resolved 3 May 2005
Engineering › Fuel Oil Service System › Filter
Issued 15 April 2005
Resolved
Install flame impingement bowl for fuel filter.
Condition: Improper Installation
Due 2 May 2005
Resolved 3 May 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 15 April 2005
Resolved
Move fire extinguisher in middle ama to an easy to reach location.
Due 2 May 2005
Resolved 3 May 2005
Lifesaving › Lifefloat › Paddle
Issued 15 April 2005
Resolved
Replace 2 paddles for lifefloats.
Condition: Unknown
Due 2 May 2005
Resolved 3 May 2005
Construction/Loadline › Structures › Scuttle
Issued 15 April 2005
Resolved
Replace dog on middle escape hatch.
Condition: Unknown
Due 2 May 2005
Resolved 1 October 2007
Resolution: Vessel deactivated
Engineering › Bilge Water Management System › Strainer
Issued 15 April 2005
Resolved
Install foot strainers for all bilge suction hoses.
Condition: Unknown
Due 2 May 2005
Resolved 3 May 2005
Communications › Alarms/Indicators › High Water Alarm
Issued 15 April 2005
Resolved
Prove proper operation of high water alarm in engine room.
Due 2 May 2005
Resolved 3 May 2005
Fire Fighting › Means of Escape › Escape Route Signs
Issued 15 April 2005
Resolved
Properly mark all emergency exits.
Condition: Unknown
Due 2 May 2005
Resolved 3 May 2005
Documentation › Certificates/Documents › Stability Letter
Issued 15 April 2005
No resolution recorded
Redo stability letter to state number of pax vsl can carry.
Condition: Unknown
Due 2 May 2005 — due date passed with no resolution recorded
Construction/Loadline › Hull
Issued 15 January 2004
Resolved
Repair damaged area on the port hull IWO stem. LEGACY COMPONENT DESC: Hull Plating
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2004
Operations/Management › Drills/Instruction
Issued 15 January 2004
Resolved
Complete U/W drills.
Due 15 February 2004
Resolved 23 January 2004
Communications › Radio Communications › EPIRB
Issued 15 January 2004
Resolved
Renew hydro release for EPIRB launcher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2004
Lifesaving › Buoyant Apparatus
Issued 15 January 2004
Resolved
Rig float lights for life floats in a float free configuration. LEGACY COMPONENT DESC: Float Light
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 January 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 15 January 2004
Resolved
Provide 8 additional adult PFD's. Vessel restricted to 33 passengers until this requirement is satisfied.
Action required: 705 - Other - as specified
Due 15 February 2004
Resolved 23 January 2004
Engineering › Fuel Oil Service System
Issued 15 January 2003
Resolved
Install flame guard on the primary fuel filter bowl for the main propulsion engine IAW 46CFR182.455 (b) (6). LEGACY COMPONENT DESC: Filter
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 30 January 2003
Engineering › Fuel Oil Service System
Issued 15 January 2003
Resolved
Install fuel filter sediment drain valve on main propulsion engine IAW 46CFR182.455 (a) (3) & (b) (9). LEGACY COMPONENT DESC: Filter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2003
Resolved 30 January 2003
Documentation › Certificates/Documents
Issued 17 April 2002
Resolved
Provide Proof of current NOAA registration in accordance with 46 CFR 180.64. LEGACY COMPONENT DESC: EPIRB Registration
Due 26 April 2002
Resolved 2 May 2002
Resolution: Vessel operator provided proof of current NOAA registration.
Construction/Loadline › Structures
Issued 17 April 2002
Resolved
Repair cracked port hole, port side, forward in accordance with 46 CFR 171.117. LEGACY COMPONENT DESC: Crack Port Hole
Due 26 April 2002
Resolved 2 May 2002
Resolution: Vessel operator repaired the cracked port hole, port side, forward.
Lifesaving
Issued 17 April 2002
Resolved
Replace sea painter on starboard lifefloat in accordance with 46 CFR 180.200. LEGACY COMPONENT DESC: Lifefloat Seapainter
Due 26 April 2002
Resolved 2 May 2002
Resolution: Vessel operator replaced sea painter on starbord lifefloat.
Lifesaving
Issued 17 April 2002
Resolved
Replace grab line on the ring buoy in accordance with 46 CFR 180.70. LEGACY COMPONENT DESC: Ring Buoy Grab Line
Due 26 April 2002
Resolved 2 May 2002
Resolution: Vessel operator replaced ring buoy grab line.
Construction/Loadline › Hull
Issued 19 December 2001
Resolved
The portlight installed below the main deck in the port ama did not have a deadlight cover. Install deadlight cover onto port ama portlight located below the main deck in accordance with 46 CFR 171.117. LEGACY COMPONENT DESC: Deadlight Cover
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 10 January 2002
Construction/Loadline › Hull › Keel
Issued 19 December 2001
Resolved
Planking above keel damaged when vessel drydocked exposing more delaminated and wet planking. Complete planking repairs to center hull per approved proposal, NVIC 7-95, and 46 CFR 176.610.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2001
Resolved 10 January 2002
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 December 2001
Resolved
Found deteriorated longitudinal stringer located starboard aft of the main hull in the engine compartment. Repair in accordance with NVIC 7-95 and 46 CFR 176.610.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 17 January 2002
Construction/Loadline › Structures
Issued 19 December 2001
Resolved
Found deteriorated support framing for the fuel tank. Make repairs to fuel tank support framing in accordance with NVIC 7-95 and 46 CFR 176.610. LEGACY COMPONENT DESC: Fuel Tank Support Framing
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 10 January 2002
Construction/Loadline › Hull
Issued 19 December 2001
Resolved
Found small fracture in hull skin in the port hull forward. Repair hull planking in accordance with NVIC 7-95 and 46 CFR 176.610. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 10 January 2002
Construction/Loadline › Hull
Issued 19 December 2001
Resolved
Found minor wood delamination under FRP sheath in main deck forward of the deck house. Repair wood deck forward of the house in accordance with NVIC 7-95 and 46 CFR 176.610. LEGACY COMPONENT DESC: Main Deck
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 10 January 2002
Fire Fighting › Structural Fire Protection - General
Issued 28 November 2001
Resolved
Found hole in bulkhead between engine compartment and accomodation space. Make engine compartment vapor tight in accordance with 46 CFR 182.465. LEGACY COMPONENT DESC: Hull Construction
Action required: 705 - Other - as specified
Due 28 December 2001
Resolved 10 January 2002
Construction/Loadline › Structures
Issued 28 November 2001
Resolved
Found deterorated shelf supporting the rudder stem and quadrant. Repair shelf in lazarette upon which rests the rudder stem and quadrant in accordance with NVIC 7-95 and 46 CFR 176.610. LEGACY COMPONENT DESC: Rudder/Quadrant Shelf
Action required: 705 - Other - as specified
Due 20 December 2001
Resolved 10 January 2002
Lifesaving
Issued 7 March 2001
Resolved
Provide (1) child life jacket in accordance with 46 CFR 180.71(b).
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Lifesaving
Issued 7 March 2001
Resolved
Provide label for life jacket storage areas in accordance with 46 CFR 185.604(f).
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Lifesaving
Issued 7 March 2001
Resolved
Provide adequate first aid kit in accordance with 46 CFR 184.710.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Navigation
Issued 21 January 2000
Resolved
Provide current charts for each island indicated in operating details of COI iaw 46CFR 184.420.
Condition: Unknown
Due 21 February 2000
Resolved 15 February 2000
Fire Fighting
Issued 21 January 2000
Resolved
Seal bulkhead penetrations in engine compartment protected by fixed gas firefighting system iaw 46CFR 182.465.
Condition: Unknown
Due 11 February 2000
Resolved 15 February 2000
Navigation
Issued 21 January 2000
Resolved
Prove proper operation of magnetic compass illumination iaw 46CFR 184.402(c).
Condition: Unknown
Due 23 February 2000
Resolved 15 February 2000
Engineering
Issued 21 January 2000
Resolved
Provide rigid ducting for engine compartment ventilation iaw 46CFR 182.465(d).
Condition: Unknown
Due 23 February 2000
Resolved 23 February 2000
Construction/Loadline
Issued 6 December 1999
Resolved
Replace (2) bolt fasteners on forward end of box beam in port ama. 46CFR 176.610.
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Electrical
Issued 6 December 1999
Resolved
Attach wire runs with metal supports vice wire ties iaw 46CFR 183.340(b)(4).
Condition: Unknown
Due 21 January 2000
Resolved 21 January 2000
Engineering
Issued 4 February 1999
Resolved
Oil pressure and water temperature gauges are inoperative due to incompleteinstallation of wiring. Complete wiring for Jacobs gauges to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Engineering
Issued 4 February 1999
Resolved
Ventilation system for the engineroom is incomplete. There is no provisioninstalled for exhaust. Install exhaust ducting in engineroom to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Construction/Loadline
Issued 20 November 1997
Resolved
Effect permanent repairs to damaged areas of center keel at bottom of stem and approx 18" aft of stem.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Fire Fighting
Issued 20 November 1997
Resolved
Provide proof of servicing for B-I portable fire extinguisher at operators station.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Construction/Loadline
Issued 20 November 1997
Resolved
Effect permenant repairs to loose longitudial floor frame (second up from keelson inboard side) in starboard hull midships.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Lifesaving
Issued 20 November 1997
Resolved
Provide six new orange smoke devices.
Condition: Unknown
Due 20 November 1997
Resolved 24 November 1997
Construction/Loadline
Issued 20 November 1997
Resolved
Effect permanent repairs to rotted wood at keelson, port hull just forward of 3rd transverse frame.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Lifesaving
Issued 20 November 1997
Resolved
Provide a life line for life ring buoy.
Condition: Unknown
Due 20 November 1997
Resolved 24 November 1997
Lifesaving
Issued 14 January 1997
Resolved
Replace two adult Type I life jackets. Vessel is restricted to 36 passengers until completed.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Lifesaving
Issued 14 January 1997
Resolved
Have expired battery in ACR Electronics EPIRB renewed by manufacturer or replace with Category I 406 MHZ EPIRB.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Fire Fighting
Issued 14 January 1997
Resolved
Have one B-II portable fire extinguisher serviced for inoperable gauge.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Construction/Loadline
Issued 1 May 1996
Resolved
CROP OUT AND RENEW ALL ROT AREAS IN STRINGERS LOCATED IN MAIN HULL, FWD CABIN.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Construction/Loadline
Issued 1 May 1996
Resolved
CROP AND RENEW DECK AREA SURROUNDING RUDDER SHAFT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Deck/Cargo
Issued 1 May 1996
Resolved
REPAIR FITTINGS ON FORWARD STARBOARD BOW PULPIT RAIL.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE LOG FOR MONTHLY EPIRB TESTING.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Accommodation/Occupational Safety
Issued 1 May 1996
Resolved
PROPERLY LABEL BOTH SIDES OF FWD EMERGENCY EXIT HATCH.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Engineering
Issued 1 May 1996
Resolved
REPLACE MAIN DIESEL ENGINE SECONDARY FUEL FILTER PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Engineering
Issued 1 May 1996
Resolved
RELABEL REMOTE EMERGENCY FUEL SHUTOFF STATION WITH DIRECTION OF SHUTOFF.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD IAW 46CFR184.506.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE PROOF OF EMPLOYEE ACKNOWLEDGEMENT OF DRUG AND ALCOHOL POLICY.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE GARBAGE LOG._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 1 May 1996
Resolved
REPLACE BUOYANCY APPARATUS WATERLIGHT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Documentation
Issued 1 May 1996
Resolved
PROPERLY LOG CREW TRAINING IAW 46CFR185.420.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Construction/Loadline
Issued 1 May 1996
Resolved
RENEW ROTTEN WOOD ON STARBOARD FANTAIL DECK STORAGE BOX.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE LOG FOR PASSENGER COUNT IAW 46CFR185.504.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE AND POST LIFE JACKET PLACARDS IAW 46CFR185.516.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE LOG FOR ABANDON SHIP AND MAN OVERBOARD DRILLS AND TRAINING IAW 46CFR185.520.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE LOG FOR FIRE FIGHTING DRILLS AND TRAINING IAW 46CFR185.524.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 1 May 1996
Resolved
PROVIDE AND PROPERLY LABEL WATERTIGHT CONTAINER FOR DISTRESS SIGNALS IAW 46CFR185.614.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Accommodation/Occupational Safety
Issued 1 May 1996
Resolved
REPAIR STARBOARD ACCOMODATION LADDER FITTING, AFT.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Construction/Loadline
Issued 1 May 1996
Resolved
CROP OUT AND RENEW WOOD AROUND ALL SIX FORWARD PORTLIGHTS.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Deck/Cargo
Issued 1 May 1996
Resolved
RENEW DECK WOOD BENEATH STARBOARD SHEET TURNING BLOCK.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Construction/Loadline
Issued 1 May 1996
Resolved
SCARF OUT, RENEW AS ORIGINAL, FORWARD AND STARBOARD AREA OF AFT CABIN DECK PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE LOG FOR WEEKLY AND MONTHLY INSPECTIONS FOR SURVIVAL CRAFT IAW 46CFR185.720 AND 46CFR185.722.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE PROOF OF 60 MINUTE SUPERVISOR TRAINING.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE PROOF OF CHEMICAL TESTING IAW 46CFR16 PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE PROOF OF SUBMISSION OF MIS FORM TO COAST GUARD HEADQUARTERS.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Documentation
Issued 1 May 1996
Resolved
PROVIDE PROOF OF DRUG AND ALCOHOL POLICY.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Fire Fighting
Issued 12 March 1996
Resolved
Provide one B-1 fire extinguisher at operating console.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Construction/Loadline
Issued 12 March 1996
Resolved
Prior to drydock schedule underway exam with Honolulu Marine Safety Office.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Construction/Loadline
Issued 12 March 1996
Resolved
Install suitable backing plates for deck railing prior to completion of pending drydock.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Construction/Loadline
Issued 12 March 1996
Resolved
Install visual and audible hi-level alarms for submersible bilge pumps at operating station and visual indicator at operating station to indicate when any automatic bilge pump is operating. To be completed prior to completion of pending drydock.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Lifesaving
Issued 12 March 1996
Resolved
Replace defective retro-reflective tape on 21 adult life preservers and twochild life preservers.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Documentation
Issued 12 March 1996
Resolved
Provide pre-employment drug testing results for deckhands. Vessel prohibited from sailing with passengers until compliance.
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Engineering
Issued 21 March 1995
Resolved
PROVIDE PROPER GROUNDING OF THE FUEL TANK.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Engineering
Issued 21 March 1995
Resolved
PROVIDE PROPER BONDING BETWEEN THE FUEL FILL AND THE FUEL TANK.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Documentation
Issued 6 January 1995
Resolved
Update and revise stability calculations to include modifications made to the vessel's keel during drydock of 06JAN95. After revision, submit calculations to the OCMI in Honolulu for review. (46 CFR 171.035)
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 6 January 1995
Resolved
REMOVE SOFT WOOD FROM DECK AREA AROUND FUEL TANK VENT AND MAKE PROPER REPAIRS AS NEEDED.
Condition: Unknown
Due 6 February 1995
Resolved 6 February 1995
Construction/Loadline
Issued 6 January 1995
Resolved
MAKE REPAIRS AS NEEDED TO STOP DRY ROT LOCATED IN THE FOLLOWING AREAS: PORTAMA: FWD WHERE DRY ROTTED ALONG KEEL - NOTABLY 2ND, 3RD, & 4TH COMPARTMENTSFM FWD END OF VSL. STBD AMA: FWD ALONG KEEL. P&S AMA'S UNDER DECK NEAR VENTCOWLS.
Condition: Unknown
Due 6 February 1995
Resolved 6 February 1995
Lifesaving
Issued 6 January 1995
Resolved
RENEW PERIPHERY LINE ON THE RING BUOY LOCATED ON THE STERN.
Condition: Unknown
Due 6 February 1995
Resolved 6 February 1995
Construction/Loadline
Issued 6 January 1995
Resolved
REMOVE SOFT WOOD FROM STBD OUTBOARD SIDE OF HELM UNDER LAMINATED DECK AND MAKE PROPER REPAIRS AS NEEDED.
Condition: Unknown
Due 6 February 1995
Resolved 6 February 1995
Construction/Loadline
Issued 6 January 1995
Resolved
DEMONSTRATE PROPER OPERATION OF OF THE BILGE SUCTION SYSTEM.
Condition: Unknown
Due 6 February 1995
Resolved 2 February 1995
Engineering
Issued 6 January 1995
Resolved
REPLACE MISSING CHAIN PLATE BOLTS LOCATED ON AFT END OF PORT AND STBD AMA'S
Condition: Unknown
Due 6 February 1995
Resolved 2 February 1995
Navigation
Issued 6 January 1995
Resolved
REPLACE MISSING COTTER KEYS, AND MOUSE ALL TURNBUCKLES ASSOCIATED WITH STEERING LINKAGES.
Condition: Unknown
Due 6 February 1995
Resolved 2 February 1995
Documentation
Issued 17 February 1994
Resolved
PROVIDE STABILITY CALCULATIONS FOR EXPOSED WATERS TO [name withheld] WITH 46 CFR 171.020 NO LATER THAN 17 MARCH 1994.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Lifesaving
Issued 21 January 1994
Resolved
RENEW THE REFLECTIVE TAPE ON THE LIFE FLOAT.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Lifesaving
Issued 21 January 1994
Resolved
PROVIDE MOUNTING BRACKET FOR THE RING LIFE BUOY.
Condition: Unknown
Due 28 January 1994
Resolved 28 January 1994
Engineering
Issued 21 January 1994
Resolved
REPLACE THE FLAME SCREEN ON THE FUEL TANK VENT WITH A 30X30 METALLIC SCREEN.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Construction/Loadline
Issued 21 January 1994
Resolved
RENEW THE HATCH COVER LEADING FROM THE CABIN TO THE MAIN DECK.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Fire Fighting
Issued 20 February 1992
Resolved
PROVIDE SUITABLE LENGTHS OF HOSE FOR THE HAND PORTABLE FIRE/BILGE PUMP AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Lifesaving
Issued 20 February 1992
Resolved
PROVIDE 10 ADULT AND 1 CHILD PFD'S TO MEET THE MINIMUM REQUIRED BY THE COI.PASSENGER TOTAL IS RESTRICTED TO 28 ADULTS AND UP TO 4 CHILDREN UNTIL THE REQUIRED NUMBER OF JACKETS ARE ON BOARD.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Lifesaving
Issued 20 February 1992
Resolved
PROVIDE A FLOAT-FREE LINK FOR THE 25 MAN BUOYANT APARATUS.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Unknown
Issued 20 February 1992
Resolved
PERFORM THE REQUIRED UNDERWAY EMERGENCY DRILLS IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Electrical
Issued 21 November 1991
Resolved
REMOVE OR PROPERLY TERMINATE ALL UNUSED OR DEAD ENDED WIRING IN MAST AND FORWARD ACCOMODATION SPACE.
Condition: Unknown
Due 21 November 1991
Resolved 21 November 1991
Construction/Loadline
Issued 21 November 1991
Resolved
CROP AND RENEW TO GOOD WOOD THE ROTTED SECTIONS OF THE LOWER FORWARD WING DECK AREA
Condition: Unknown
Due 21 November 1991
Resolved 21 November 1991
Construction/Loadline
Issued 21 November 1991
Resolved
RENEW THE TWO CRACKED PORT LIGHTS IN THE STARBOARD AMA (HULL).
Condition: Unknown
Due 21 November 1991
Resolved 21 November 1991
Construction/Loadline
Issued 21 November 1991
Resolved
PROVE THE WATER TIGHT INTEGRITY OF ALL PORT LIGHTS.
Condition: Unknown
Due 21 November 1991
Resolved 21 November 1991
Fire Fighting
Issued 5 February 1991
Resolved
PROVIDE ONBOARD PORTABLE FIRE/BILGE PUMP OF AT LEAST 5 GPM PROIR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Documentation
Issued 5 February 1991
Resolved
POST OIL POLLUTION PREVENTION OIL PLACARD IN MACHINERY SPACE AND PLASTICS/ WASTE DISPOSAL PLACARD ONBOARD TO COMPLY WITH MARPOL ANNEX 5.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Engineering
Issued 5 February 1991
Resolved
PLACE 30X30 MESH SCREEN OVER FUEL TANK VENT.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Lifesaving
Issued 5 February 1991
Resolved
PROVIDE 6 ADDITIONAL TYPE 1 APPROVED ADULT LIFEJACKETS ONBOARD TO BRING TOTAL 42 ADULT AND 5 CHILD.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991
Resolved
REPAIR STRUCTURE SUPPORTING BATTERY BOXES OR RELOCATE BATTERIES TO SECURE LOCATION.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Fire Fighting
Issued 5 February 1991
Resolved
PROVIDE PROOF OF SERVICING OF PROTABLE FIRE EXTINGUISHERS AND PLACE THREE ADDITIONAL TYPE II EXTINGUISHERS ONBOARD(TOTAL REQ'D 5-BII, 1-BI).
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Electrical
Issued 5 February 1991
Resolved
PROPERLY TERMINATE UNUSED WIRING OR REMOVE FROM VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Construction/Loadline
Issued 5 February 1991
Resolved
MAKE REPAIRS TO DECK FASTENING FOR SECOND STATION AFT STARBOARD SIDE LIFE RAIL. ALSO EXAMINE OTHER FASTENINGS OF STARBOARD LIFE RAIL AND REPAIR AS NECESSARY.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Construction/Loadline
Issued 5 February 1991
Resolved
REPAIR PORTHOLE GLASS STBDSIDE WITH GLASS OR MATERIAL OF EQUAL OR GREATER STRENGTH TO MAKE WATERTIGHT.
Condition: Unknown
Due 5 February 1991
Resolved 5 February 1991
Construction/Loadline
Issued 11 May 1990
Resolved
PROVIDE ONE FIXED POWER BILGE PUMP OR ONE FIXED HAND BILGE PUMP IN EACH AMAIN COMPLIANCE WITH 46 CFR 182.25-10.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Deck/Cargo
Issued 11 May 1990
Resolved
NDT (DYE PENETRANT), GRIND, REMOVE CORROSION ON MAIN MAST, TO BE INSPECTED BY USCG INSPECTOR. MAIN MAST IS NOT TO BE USED UNTIL SATISFACTORY INSPECTION.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Electrical
Issued 11 May 1990
Resolved
SECURE BATTERIES IN THEIR TRAYS.
Condition: Unknown
Due 11 May 1990
Resolved 11 May 1990
Lifesaving
Issued 8 February 1989
Resolved
PROVIDE 6 HAND RED DISTRESS SIGNALS AND 6 HAND ORANGE SMOKE DISTRESS SIGNALS OR 12 HAND COMBINATION FLARE AND SMOKE DISTRESS SIGNALS THAT ARE NO OLDER THAN 3 YEARS FROM THE DATE OF MANUFACTURE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Accommodation/Occupational Safety
Issued 8 February 1989
Resolved
REMOVE THE BUTANE STOVE FROM THE VESSEL PRIOR TO CARRYING PASSENGERS. THE USE OF LIQUIFIED PETROLEUM GAS FOR ANY PURPOSE IS PROHIBITED ON ALL PASS- ENGER VESSELS.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Accommodation/Occupational Safety
Issued 8 February 1989
Resolved
REMOVE THE KEROSINE STOVE OR MAKE IT PERMANENTLY NOT OPERATIONAL. THE STOVEINSTALLATION DOES NOT COMPLY WITH 46 CFR 147.50(E).
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Fire Fighting
Issued 8 February 1989
Resolved
PROVIDE A USCG APPROVED TYPE B-II PORTABLE FIRE EXTINGUISHER FOR THE STBD ALMA PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 8 February 1989
Resolved 8 February 1989
Engineering
Issued 19 February 1988
Resolved
INSTALL FLAME DEFLECTOR SHIELD ON RACOR FUEL FILTER.
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Engineering
Issued 19 February 1988
Resolved
REPLACE FLEXIBLE FUEL HOSE WITH APPROVED TYPE COMPLYING WITH 46 CFR 182. 20-40 (A)(2)(II).
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Accommodation/Occupational Safety
Issued 19 February 1988
Resolved
RENEW OR MAKE PERMANENT REPAIRS TO THE ENGINEROOM VENTILATION FAN AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Unknown
Issued 6 March 1987
Resolved
PROVIDE AND POST AN EMERGENCY CHECKOFF LIST.
Condition: Unknown
Due 6 March 1987
Resolved 6 March 1987
Unknown
Issued 6 March 1987
Resolved
PROVIDE AND INSTALL PROPER DEAD COVERS FOR ALL PORT LIGHTS BELOW THE MAIN DECK AS DEFINED IN 46 CFRR 171.119.
Condition: Unknown
Due 6 March 1987
Resolved 6 March 1987
Unknown
Issued 6 March 1987
Resolved
PORT VESSEL'S CERTIFICATE OF INSPECTION ON BOARD THE VESSEL.
Condition: Unknown
Due 6 March 1987
Resolved 6 March 1987
Unknown
Issued 10 February 1987
Resolved
REPAIR HULL PLANKING ON STARBOARD AFT OUTBOARD HULL WHERE DAMAGED.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Lifesaving
Issued 27 February 1986
Resolved
REPLACE ONE LIFEJACKET. VESSEL IS RESTRICTED TO 41 PERSONS UNTIL THIS ITEMIS CLEARED.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Navigation
Issued 27 February 1986
Resolved
REMOVE EXCESSIVE FREE PLAY IN STEERING LINKAGE.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Navigation
Issued 27 February 1986
Resolved
PROVIDE VALID FCC CERTIFICATE.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Electrical
Issued 7 January 1986
Resolved
SUBMIT A DRAWING (SCHEMATIC) OF VESSEL'S EXISTING ELECTRICAL SYSTEM FOR APPROVAL. ONCE DRAWING HAS BEEN APPROVED MAKE VESSEL AVAILABLE FOR AN INSPECTION OF THE ELECTRICAL SYSTEM.
Condition: Unknown
Due 7 January 1986
Resolved 7 January 1986