MAURY USCG vessel records Sign in
← All vessels

NOBLE JOE ALFORD

NOBLE JOE ALFORD is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 61 inspections since 1982, most recently in May 2024, along with 119 deficiencies and 1 casualty investigation in 2008.

Records from 1982 to 2024. Most recent: inspection, 7 May 2024.

Built
1982
Last inspected
7 May 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8754267 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WRW 2663
Flag
UNITED STATES
—
Maury page id
psix-54268

Inspections, by type

…with no type recorded15
Years with a record 21 calendar years (1982–2024)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it6338 - Convention (Subpart B), Gross Ton
1901 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BOTRUC Offshore Supply Vessel · MISLE 1940 · 10 July 2008 · activity 3264631

Inspection history · 61

7 May 2024 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7912852
18 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7851089
30 March 2009 Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3443132
30 October 2008 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3354234
10 July 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3264631
3 October 2007 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3072331
11 May 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2991673
18 August 2005 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2472315
16 August 2005 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2426647
10 August 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2458519
18 May 2005 Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2361638
21 March 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2315512
21 March 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2315853
21 October 2004 Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2213235
15 September 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1905653
1 November 2002 Deficiency Check · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1699708
20 June 2002 Underwater Inspection in lieu of Drydock
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1638693
1 April 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1599753
7 December 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1626095
20 September 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073994
14 August 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373588
5 March 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059499
2 February 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1058748
3 January 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 770242
22 August 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403211
10 July 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1051559
7 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815237
16 August 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470223
7 May 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1128767
7 October 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468889
4 June 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1128541
15 April 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 788992
1 March 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 782641
30 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784925
22 December 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1116917
17 December 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 780587
1 September 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785107
19 August 1997 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1453368
26 April 1997 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1378027
25 April 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 102954
25 March 1997 Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1335361
20 December 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922390
26 July 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1352258
1 May 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041269
25 April 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1340474
21 December 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345034
26 October 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893872
11 March 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337055
5 November 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331671
31 July 1987 Deficiency Check · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003596
15 July 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017939
20 February 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321963
13 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319781
30 October 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337458
28 February 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304821
5 December 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294076
24 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284082
26 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285440
23 February 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279138
1 December 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969620
10 November 1982 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 970541

Deficiency record · 119

Construction/Loadline › Hull › Bottom Plating
Issued 21 April 2009 Resolved
Port Column not ready for inspection, make ready for internal inspection.
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 20 May 2009
Resolution: Column ready for Phase I of SEILOD. //s// J Laflamme
Construction/Loadline › Hull › Hull Plating
Issued 21 April 2009 Resolved
Complete Phase II of SEILOD at next rig move.
Action required: 705 - Other - as specified
Due 19 April 2024
Resolved 19 April 2024
Resolution: Owner/operater requested to place the vsl in laid up status so it is exempt from inspection.
Fire Fighting › Fire Hoses › Connections
Issued 16 August 2005 Resolved
Replace all indoor spanner wrenches at all hose stations.
Due 16 September 2005
Resolved 7 April 2006
Resolution: All indoor spanner wrenches have been replaced.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 16 August 2005 Resolved
Provide proof of an approved FCP or submit to the Coast Guard for approval.
Due 16 September 2005
Resolved 18 August 2005
Resolution: Provided approval letter from MORMS dated 10 AUG 2005.
Construction/Loadline › Hull › Hull Plating
Issued 18 May 2005 Resolved
Complete Phase II (underwater exam) by 12 August 2005 to the satisfaction of the CG inspector or ABS surveyor.
Due 12 August 2005
Resolved 20 June 2005
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 1 November 2002 Resolved
Provide two charges for line throwing rockets
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 December 2002
Resolved 17 December 2002
Electrical › Electric Generation Source (emergency)
Issued 1 November 2002 Resolved
Prove proper operation of stand by generator overspeed shutdown at proper RPMs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 December 2002
Resolved 17 December 2002
Communications › Alarms/Indicators › Fire Alarm
Issued 1 November 2002 Resolved
Prove proper operation of general alarm bells at the keyway and shaker flat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2002
Resolved 17 December 2002
Deck/Cargo › Holds/Tanks
Issued 20 June 2002 Resolved
PROVIDE ABS/DIVE REPORTS RESULTS OF COMPLETION OF SEILOD BASED ON NOBLE DRILLING SEILOD
Action required: 705 - Other - as specified
Resolved 17 January 2003
Lifesaving
Issued 14 August 2001 Resolved
Renew frayed cable on fall protective device (drum) in overhead of KEY Area._x001C_ SALA FALL ARREST BLOCK._x001C_
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Unknown
Issued 14 August 2001 Resolved
Renew forward and aft pit room door gaskets and renew forward pit room door.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Deck/Cargo
Issued 14 August 2001 Resolved
Crop and renew split section of drill water supply line in Pressure Room.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Construction/Loadline
Issued 22 August 2000 Resolved
CLEAN AND DEWATER TANKS #3 PORT #3 STARBOARD,#11 PORT AND #11 STARBOARD ANDMAKE AVAILABLE FOR REINSPECTION BY ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Construction/Loadline
Issued 22 August 2000 Resolved
MAKE ALL MAT TANKS AVAILABLE FOR COAST GUARD INSPECTION. ENSURE TANKS ARE CLEAN AND DEWATERED. CONDUCT UNDERWATER SURVEY AND NDE OF COLUMN TO MAT CONNECTIONS.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Engineering
Issued 16 August 1999 Resolved
HARD PIPE FUEL SYSTEM ON CEMENTING UNIT IN MUD PUMP ROOM. NO FLEX FUEL HOSEMAY EXCEED 30 INCHES.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 7 October 1998 Resolved
CONDUCT 1.1 OPERATIONAL TEST OF LIFEBOAT RELEASE GEARS OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE LOCAL OCMI.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Electrical
Issued 7 October 1998 Resolved
REPAIR EMERGENCY LIGHTING FOR LIFEBOAT STATION #2.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Unknown
Issued 7 October 1998 Resolved
INSTALL A SAFETY RELIEF VALVE ON THE COLD START AIR COMPRESSOR.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Accommodation/Occupational Safety
Issued 19 August 1997 Resolved
PROVIDE DOOR FOR LAUNDRY ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Electrical
Issued 19 August 1997 Resolved
MARK BREAKER IN PASSAGEWAY NEAR OFFICE.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Electrical
Issued 19 August 1997 Resolved
REPAIR ELECTRICAL PLUG DOOR STBD SIDE DRILL FLOOR.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Accommodation/Occupational Safety
Issued 19 August 1997 Resolved
Arrange bunk in hospital space for access on both sides
Condition: Unknown
Due 21 August 1997
Resolved 26 August 1997
Lifesaving
Issued 19 August 1997 Resolved
REPAIR/REPLACE BRACKET FOR HYDRAULIC OIL TANK ON #1 LIFEBOAT.
Condition: Unknown
Due 21 August 1997
Resolved 26 August 1997
Lifesaving
Issued 19 August 1997 Resolved
REPAIR EXHAUST LEAK ON EXHAUST TUDING IN ENGINE SPACE ON NO 1 LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 August 1997
Resolved 26 August 1997
Lifesaving
Issued 19 August 1997 Resolved
MISSING TWO PFDS FOR LIFEBOAT.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Lifesaving
Issued 19 August 1997 Resolved
Mark access route from aiming circle to heliport ladders.
Condition: Unknown
Due 21 August 1997
Resolved 26 August 1997
Navigation
Issued 19 August 1997 Resolved
Repair/replace inoperable fog signal.
Condition: Unknown
Due 20 August 1997
Resolved 26 August 1997
Lifesaving
Issued 19 August 1997 Resolved
REPAIR FUEL LEAK ON NO 2 LIFEBOAT TUBING ON ENGINE.
Condition: Unknown
Due 21 August 1997
Resolved 26 August 1997
Lifesaving
Issued 19 August 1997 Resolved
REPAIR AFT WINDOW BRACKETS ON NO 1 LIFEBOAT.
Condition: Unknown
Due 21 August 1997
Resolved 26 August 1997
Lifesaving
Issued 19 August 1997 Resolved
REPLACE/REPAIR LAGGING ON NO 1 LIFEBOAT EXHAUST SYSTEM.
Condition: Unknown
Due 21 August 1997
Resolved 26 August 1997
Lifesaving
Issued 19 August 1997 Resolved
REPLACE TUBING LFROM LUBECELL TO INTAKE ON NO 1 LIFEBOAT.
Condition: Unknown
Due 21 August 1997
Resolved 26 August 1997
Electrical
Issued 19 August 1997 Resolved
REPAIR/REPLACE ALL DEADEND WIRES IN SHOWER AND HEAD AREA.
Condition: Unknown
Due 21 August 1997
Resolved 26 August 1997
Construction/Loadline
Issued 19 August 1997 Resolved
BOLT DOWN MANHOLE COVERS ON BALLAST TANKS IN COLUMNS AND CATCH TANK AT PORTCOLUMN.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Deck/Cargo
Issued 19 August 1997 Resolved
PROVIDE PROPER SIZED FLAME SCREENS (30/30) ON L/O TANK VENTS.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Documentation
Issued 19 August 1997 Resolved
PROVIDE CURRENT LOADLINE CERTIFICATE.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Fire Fighting
Issued 19 August 1997 Resolved
LABEL OPEN/CLOSE ON ALL FIRE DAMPNERS.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Fire Fighting
Issued 19 August 1997 Resolved
PROVIDE HALON ACTIVATION INSTRUCTIONS ON SCR ROOM ENTRANCE STBD SIDE.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Fire Fighting
Issued 19 August 1997 Resolved
MOVE HALON RELEASE PLACARDS TO THE ALARMS THEMSELVES.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Lifesaving
Issued 19 August 1997 Resolved
PROVIDE FIRST AID KIT FOR FOR DRILL FLOOR PER FCP.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Fire Fighting
Issued 19 August 1997 Resolved
MAKE CORRECTIONS TO FIRE CONTROL PLAN AS NOTED ON CG835.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Electrical
Issued 19 August 1997 Resolved
MAKE STUFFING TUBE WATERTIGHT IN STBD AFT COLUMN, BEHIND WT DOOR.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Lifesaving
Issued 19 August 1997 Resolved
PROVIDE ALL EQUIPMENT FOR NO 1 AND 2 LIFEBOATS.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Electrical
Issued 19 August 1997 Resolved
REPAIR SOUND POWERED PHONE IN STBD AFT COLUMN.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Lifesaving
Issued 19 August 1997 Resolved
PROVIDE SMOKE ALARM FOR BALLAST CONTROL COMPARTMENT.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Electrical
Issued 19 August 1997 Resolved
SECURE DEAD END WIRING AND PROVIDE COVER FOR JUNCTION BOX IN RADIO ROOM.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Lifesaving
Issued 19 August 1997 Resolved
LABEL GENERAL ALARM LIGHT IN ENGINE ROOM AFTER BULKHEAD AND LABEL ALARMS THROUGHOUT RIG.
Condition: Unknown
Due 21 August 1997
Resolved 10 September 1997
Electrical
Issued 26 October 1988 Resolved
CORRECT GENERAL ALARM DISTRIBUTION PANEL TO NEED A TOOL TO BE OPENED TO COMPLY WITH 46 CFR 113.25-15.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Deck/Cargo
Issued 26 October 1988 Resolved
PROVIDE A STANDARD DISCHARGE CONNECTION (33 CFR 155.430).
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Deck/Cargo
Issued 26 October 1988 Resolved
PROVIDE INFO ON THE ELECTRIC HAND AND FORK LIFT IN THE SACK ROOM TO SHOW UL OR FM APPROVAL.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988 Resolved
CORRECT INTERLOCK SWITCH ON THE STARBOARD PUMP ROOM ELEVATOR LOCATED IN THE OVERHEAD TRAP DOOR.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988 Resolved
REMOVE THROW LEVER AND LOCK WITH A PAD LOCK THE POWER SUPPLY DISCONNET IN THE EMERGENCY GENERATOR ROOM FOR THE GENERAL ALARM POWER SUPPLY.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Unknown
Issued 26 October 1988 Resolved
PROVIDE A HAND RELIEVING DEVICE FOR THE RELIEF VALVE ON THE DRILL FLOOR AIRRECEIVER.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Unknown
Issued 26 October 1988 Resolved
REPLACE FIVE BULK TANK RELIEF VALVES SET NOT TO EXCEEED 45 PSI.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988 Resolved
MAKE GENERAL ALARM BELL OPERABLE IN THE PORT PUMP ROOM.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988 Resolved
INSTALL BLANK IN THE LD POWER PANEL IN THE SCR ROOM.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988 Resolved
PROVIDE 250 VOLT FUSES FOR THE GENERAL ALARM DISTRIBUTION PANEL. 600 VOLT FUSES ARE INSTALLED (46 CFR 113.25-16).
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Fire Fighting
Issued 26 October 1988 Resolved
RENEW PACKING FOR PORT PUMP ROOM FIRE PUMP.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Construction/Loadline
Issued 26 October 1988 Resolved
PROVIDE GAUGES FOR POTABLE WATER AND BALLAST PUMPS IN THE PORT PUMP ROOM.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Deck/Cargo
Issued 26 October 1988 Resolved
PROVIDE DIRECTORY FOR BREAKER PANEL IN PORT CRANE.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988 Resolved
RENEW LIGHT COVERS FOR LAUNDRY, LEVEL 2 AC ROOM, AND STAIRWELL (2 COVERS).
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Fire Fighting
Issued 26 October 1988 Resolved
HYDROSTATICALLY TEST ALL PORTABLE CO2 WITH HYDRO DATE EARLIER THAN OCT 83.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Construction/Loadline
Issued 26 October 1988 Resolved
MARK ALL PUMP MOTOR CONTROLLERS IN PUMP ROOMS.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988 Resolved
INSTALL MAT IN FRONT OF THE GENERATOR CONTROL AND POWER PANELS IN THE SCR ROOM (46 CFR 111.30-11).
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Accommodation/Occupational Safety
Issued 26 October 1988 Resolved
REOPEN ALL WELDED EXITS AND REMOVE ALL LOCKING DEVICES FROM EXITS PRIOR TO PLACING RIG BACK IN SERVICE.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988 Resolved
REMOVE ALL UNARMORED CABLE AND DEADEND CABLES FROM SHALE SHAKER AREA.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Fire Fighting
Issued 26 October 1988 Resolved
REPAIR FIRE DAMPER CABLE FOR UPPER QUARTERS.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Lifesaving
Issued 26 October 1988 Resolved
REFILL THE TOP PORT CABIN AIR CYLINDER IN THE PORT LIFEBOAT.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Lifesaving
Issued 26 October 1988 Resolved
REPAIR GEL COAT ON STBD LIFEBOAT PORT SIDE AFT WHERE SCRAPED OFF (1"X3" AREA).
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988 Resolved
STENCIL OR TAG FOR VISUAL ID THE LOCATION OF THE REMOTE FUEL SHUT DOWN FOR THE EMERGENCY GENERATOR AND MAIN GENERATORS. THIS PERTAINS TO THE REACH RODS.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988 Resolved
SHOW THE PROPER OPERATION OF THE EMERGENCY GENERATOR AUTO BUS TRANSFER SYSTEM.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Lifesaving
Issued 5 November 1987 Resolved
PROVIDE ONE LIFE RING WITH LINE OF SUFFICIENT LENGHT ATTACHED FOR PORT AMIDSHIPS STATION. UNIT PRESENTLY MISSING PER 46 CFR 108.425
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Fire Fighting
Issued 5 November 1987 Resolved
REPLACE ALL EX 607 HOSES ABOARD AS FOUND ON FIRE BOTTLES. THESE HOSES WEREFOUND TO BE DEFECTIVE AND NOT FIT FOR SERVICE INTENDED.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Fire Fighting
Issued 5 November 1987 Resolved
PROVIDE FOUR 1 1/2" BY 50' LENGTHS AND TWO 2 1/2" BY 50' LENGTHS OF FIRE HOSE TO REPLACE THOSE PRESENTLY MISSING. THIS IS TO BE ACCOMPLISHED PRIOR TO RIG MOVEMENT BUT NOT LATER THAN NOTED DATE. 46 CFR 108.425
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Lifesaving
Issued 5 November 1987 Resolved
REPLACE GLAZED WINDOWS IN PORT BOAT, PROVIDE TWO (2) ORANGE SMOKES FOR STARBOARD BOAT AND REPLACE ASPIRIN IN BOTH FIRST AID KITS.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Fire Fighting
Issued 5 November 1987 Resolved
INSTALL PRESSURE RELIEF VALVE OR THE DISCHARGE SIDE OF EACH FIRE PUMP IN THE PORT AND STBD PUMP ROOMS, IN ACCORDANCE WITH 46 CFR 108.417.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Electrical
Issued 5 November 1987 Resolved
REPLACE PLASTIC TIE WRAPS SECURING ELECTRICAL CABLES IN SHALE SHAKER AREA WITH NON-CORROSIVE METAL WRAPS 5/8" WIDE, OR OTHER APPROVED SECURING METHODALSO REPLACE THOSE PLASTIC TIE WRAPS NOTED UNDER DRILL FLOOR WITH 5/8" OR BETTER NON-CORROSIVE METALLIC TYPE.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Accommodation/Occupational Safety
Issued 30 October 1986 Resolved
RENEW AS ORIGINAL ALL DAMAGED ESCAPE LADDER PLATFORM.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Fire Fighting
Issued 30 October 1986 Resolved
MAKE OPERABLE THE HAND OPERATED FIRE DAMPNERS LOCATED ON PORT BOW AND STBD SIDE FORWARD.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Construction/Loadline
Issued 30 October 1986 Resolved
PROVIDE OPERATION OF ALL AIR OPERATED VALVES (BOTH LOCAL-REMOTE) IN PORT AND STBD PUMP ROOMS.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Lifesaving
Issued 30 October 1986 Resolved
REPLACE THE FALLS ON BOTH DAVIT ASSEMBLIES DUE TO DETERIOTATION AT MECHANI-CAL CONNECTOR AND THIMBLE.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Lifesaving
Issued 30 October 1986 Resolved
PROVIDE/REPAIR THE FOLLOWING EQUIPMENT FOR #1 LIFEBOAT; A. LIGHT STICK FOR COMPASS,B. CLEAN CABIN GLASS, C. D. PROVIDE REQUIRED AMOUNT OF WATER, E. PROVIDE 36 RATIONS, AND F. REPLACE OR THICKNSS GUAGE AND PINT FUEL TANK.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Lifesaving
Issued 30 October 1986 Resolved
PROVID/REPAIR THE FOLLOWING ITEMS FOR #2 LIFEBOAT; A. REPAIR INOPERATIVE ENGINE EXHAUST CHECK VALVE, B. REFILL EMPTY/LOW AIR BOTTLES, C. PROVIDE THEREQUIRED AMOUNT OF WATER AND D. PROVIDE BOAT HOOK.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Construction/Loadline
Issued 30 October 1986 Resolved
RELAMP BALLAST CONTROL BOARD.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Navigation
Issued 30 October 1986 Resolved
PAINT LOADLINE AND DRAFT MARKS.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Navigation
Issued 30 October 1986 Resolved
PROVIDE APPROVAL LEHER FOR JACOBS LADDER STORED BOW AREA UNDER HELO DECK ORSUBMIT FOR APPROVAL THE USE OF A JACOBS LADDER MEETING 46CFR 160.017.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Electrical
Issued 30 October 1986 Resolved
MAKE OPERABLE THE PORT ELEVATOR INTERLOCK.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Accommodation/Occupational Safety
Issued 30 October 1986 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE FIRST AID KIT: NINE (09) TRIANGULARBANDAGES; FIVE (05) 2 1/4 BANDAGE COMPRESS.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Fire Fighting
Issued 30 October 1986 Resolved
HYDROSTATIC TEST SCBA BOTTLE LOCATED IN TOOLPUSHER'S OFFICE.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Lifesaving
Issued 30 October 1986 Resolved
PROVIDE MISSING SERVICE LINE FOR THE LINE THROWING APPLICNACE.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Electrical
Issued 30 October 1986 Resolved
MAKE OPERABLE ALL EMERGENCY LIGHTS.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Fire Fighting
Issued 30 October 1986 Resolved
PROVIDE THE SCBA BOTTLES (FIBERGLASS) WITH REQUIRED PRESSURE.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Electrical
Issued 30 October 1986 Resolved
PROVE OPERATION OF HIGH ENGINE TEMPERATURE ALARM AND LOW LUBE OIL PRESSURE ALARM ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Fire Fighting
Issued 30 October 1986 Resolved
REPLACE MISSING TRIP BOTTLE FOR THE SCR ROOM HALON SYSTEM.
Condition: Unknown
Due 30 October 1986
Resolved 30 October 1986
Documentation
Issued 5 December 1985 Resolved
PROVIDE ONBOARD, CG MMT LETTER DTD 28APRIL FOR THE OPERATING MANUAL AS PER 46 CFR 109.121.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Electrical
Issued 5 December 1985 Resolved
MAKE OPERABLE THE ELEVATOR INTERLOCK AND DOOR SAFETY DEVICES FOR PORT AND STARBOARD ELEVATORS. 46 CFR 111.91.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Electrical
Issued 5 December 1985 Resolved
MAKE OPERABLE, GENERAL ALARMS IN MUD PIT ROOM AND KEYWAY AS PER 46 CFR 113.25.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Fire Fighting
Issued 5 December 1985 Resolved
PROVIDE NON-CONDUCTIVE GLOVES FOR FIREMAN'S OUTFITS PER 46 CFR 108.497.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Lifesaving
Issued 5 December 1985 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Lifesaving
Issued 5 December 1985 Resolved
REPLACE THE FOLLOWING ITEMS IN #2 LIFEBOAT: ORANGE SMOKE DISTESS, HAND HELD FLARES. 46 CFR 108.503.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Lifesaving
Issued 5 December 1985 Resolved
REPLACE TWELVE (12) PARACHUTE FLARES. 46 CFR 108.521.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Documentation
Issued 5 December 1985 Resolved
PROVIDE ONBOARD THE REQUIRED NUMBER OF LIFEBOATMEN PER MANNING REQUIREMENTSSTATED ON CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Electrical
Issued 5 December 1985 Resolved
RESET, AND TEST IN PRESENCE OF A COAST GUARD INSPECTOR, THE OVERSPEED TRIP FOR THE EMERGENCY GENERATOR. 46 CFR 112.05.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Lifesaving
Issued 5 December 1985 Resolved
THE SECONDARY LIFESAVING EQUIPMENT MUST BE REPLACED BY 12 DECEMBER 1985. MANNING IS REDUCED TO TWENTY-FIVE (25) PERSONS.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Deck/Cargo
Issued 5 December 1985 Resolved
INSTALL A HAND RELIEVING DEVICE ON THE RELIEF VALVE FOR #4 P-BULK TANK. 46 CFR 54.15.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Deck/Cargo
Issued 5 December 1985 Resolved
REPAIR OR REPLACE THE RELIEF VALVE FOR #3 STARBOARD BULK TANK. 46 CFR 54.15.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Deck/Cargo
Issued 5 December 1985 Resolved
CONDUCT TEST AND INSPECTION OF CRANES PER 46 CFR 107.259.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Deck/Cargo
Issued 5 December 1985 Resolved
PROVIDE EVIDENCE OF TEST FUEL OIL LOADING HOSE. 33 CFR 155.800.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Documentation
Issued 5 December 1985 Resolved
PROVIDE ONBOARD, CONSTRUCTION PORTFOLIO PER 46 CFR 107.305(H)(H).
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Unknown
Issued 26 October 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PORTAL 202 DN652439
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Deck/Cargo
Issued 26 October 1984 Resolved
PROVIDE HEAT RESISTANT SIGHT GLASSES IN THE FUEL OIL DAY TANKS 46CFR58.50
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Unknown
Issued 26 October 1984 Resolved
RESUBMIT THE FIRE CONTROL PLAN TO THE [name withheld], SHOWING THE PROPER NUMBER OF 21/2 INCH AND 1 1/2 INCH FIRE HOSE STATIONS AND DEPICITING GENERAL ALARM CONTACTORS. 46CFR107.305
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Electrical
Issued 26 October 1984 Resolved
REPAIR THE REMOTE VENTILATION SHUTDOWNS. 46CFR108.181
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Lifesaving
Issued 26 October 1984 Resolved
WEIGHT TEST THE LIFEBOATS (TWO) IN THE PRESENCE OF A COAST GUARD INSPECTOR 46CFR108.507
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Electrical
Issued 26 October 1984 Resolved
REPAIR THE EMERGENCY GENERATOR LIGHTING SWITCH GEAR. 46CFR112.05.
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Electrical
Issued 26 October 1984 Resolved
REPAIR THE LOSS OF EXHAUST VENTILATION ALARM IN THE MUD PIT 46CFR108.175.
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Electrical
Issued 26 October 1984 Resolved
PROVIDE A REMOTE SHUTDOWN FOR THE FUEL OIL PURIFIER 46CFR111.13.
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Unknown
Issued 1 December 1983 Resolved
PROVIDE ONBOARD A MINIMUM OF THREE (3) CARTRIDGES FOR LINE THOWING SHOULDERGUN.
Condition: Unknown
Due 1 December 1983
Resolved 1 December 1983
Documentation
Issued 1 December 1983 Resolved
PROVIDE ONBOARD THE UPDATED OPERATIONS MANUAL. REVISION 2, BEARING USCG APPROVAL STAMP DATED 28 APRIL 1983.
Condition: Unknown
Due 1 December 1983
Resolved 1 December 1983
Documentation
Issued 1 December 1983 Resolved
RENEW THE UNIT'S USCG MARINE DOCUMENT WHICH WAS ISSUED ON 05 DECEMBER 1982.
Condition: Unknown
Due 1 December 1983
Resolved 1 December 1983

Casualty record · 1

10 July 2008Routine · role: Involved in a Marine Casualty · activity 3264631
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.